PubMed Health⌕ Search

Biomedical subjects

L C Hartman

Publications and source records attributed to L C Hartman.

5 recordsLinked to original sources

The application of panoramic zonography to the diagnosis of maxillofacial fractures.

Traditionally, multiple radiographic views and techniques were required to elucidate the nature and extent of fractures of the maxillofacial complex. As a result, patient cost in terms of time, expense, manipulation, and radiation exposure scaled upward. Synthesis and interpretation of the fragmented bits of information from multiple films also constituted a labor-intensive process. A new imaging modality, panoramic zonography, provides precise anatomic imaging of preselected areas of interest with minimal radiation exposure. The usefulness of this technique in the diagnosis, treatment, and follow-up of traumatic events in the mandibular and maxillofacial regions is illustrated by a series of cases.

Adult↗

Effects of pretreatment sterilization and cleaning methods on materials properties and osseoinductivity of a threaded implant.

A new endosseous titanium implant has been designed to replace skin adhesives as a method of retention of maxillofacial prostheses. The effects of various methods of preimplantation preparation on surface characteristics of the implant were analyzed with electron spectroscopy for chemical analysis. Having undergone one of several pretreatment protocols, fixtures were implanted in the crania of Yucatan miniature hairless swine. Both argon radiofrequency glow discharge and ultraviolet chamber treated implants were associated with the rapid ingrowth and maturation of new bone around the fixture. Conventional steam sterilization was associated with a paucity of neo-osteogenesis accompanied by the production of thick collagen slings at the interface. Apparently, the bulk material, fixture design, and method of surface preparation all contribute to the ultimate clinical fate of an implant.

Animals↗

Silicone rubber temporomandibular joint (TMJ) meniscal replacements: postimplant histopathologic and material evaluation.

Medical grade silicone rubber has long been considered a suitable meniscal replacement, but there has been increasing concern about migration of this material into adjacent tissues. The objectives of this study were to determine the definitive composition of tissue-incorporated material which is presumed by light microscopy to be silicone and to identify long term histopathologic sequelae of meniscal replacements. Adult female patients underwent meniscectomy and replacement with silicone rubber (Silastic) implants. After 12 to 18 months, recurrence of symptoms in 8% of these cases led to implant removal with excision of peri-implant fibrous pseudocapsules. Excised tissues, including one preauricular lymph node and implants were submitted for light microscopy, SEM, and energy dispersive x-ray microanalysis (EDX) for the identification of elemental composition, critical surface tension measurement, and internal reflection infrared spectroscopy. EDX revealed prominent peaks for silicon in both pseudocapsular and nodal tissues. Morphologic findings surrounding the long-term implants included foreign body reaction, synovitis, dystrophic calcification, fibrocartilaginous metaplasia, hyalinization, and scarring. Particulate silicone debris induced a pathologic response in the tissues and migrated to nodes. These findings suggest that periodic evaluation be performed over the life of such implants to rule out breakdown under function. These findings should intensify the search for improvements or replacements for silicone rubber as an interpositional material in the temporomandibular joint.

Calcinosis↗

The use of elemental microanalysis in verification of the composition of presumptive amalgam tattoo.

Routine histochemistry, special stains, and energy dispersive x-ray microanalysis (EDX) were used to analyze 15 cases of presumptive amalgam tattoo. Histologically, the fine, spherical, golden brown granules of amalgam were remarkably similar to hemosiderin and melanin granules, and routine and special stains were not always reliable in differentiating one from the others. EDX provided a simple, fast, inexpensive, and reliable method for identifying the precise elemental composition of the pigmented material.

Connective Tissue↗