PubMed Health⌕ Search

Biomedical subjects

L C Meis

Publications and source records attributed to L C Meis.

2 recordsLinked to original sources

Correlative imaging with monoclonal antibodies in colorectal, ovarian, and prostate cancer.

Monoclonal antibody (MoAb) imaging has contributed greatly to the diagnosis and staging of both colorectal and ovarian cancers, and recently has been tested in patients with prostate cancer. Anatomic imaging modalities such as computed tomography, ultrasound, and magnetic resonance imaging have deficiencies in imaging each of these cancers that can be complemented or overcome by using radioimmunoscintigraphy. The management of patients with colorectal cancer, in particular, has been aided by developments in immunoscintigraphy. The new, safe, and easy-to-prepare MoAbs make possible an effective form of colon and rectal cancer imaging that has been used for (1) staging primary colorectal tumors in presurgical patients, (2) determining extent of disease, (3) continuing surveillance of patients at risk for recurrence of disease, (4) managing patients with elevated carcinoembryonic antigen levels (even those with otherwise negative workup results), and (5) imaging for occult, disease in patients both before and after surgery. In ovarian cancer patients, MoAbs are promising as safe, sensitive imaging tools. The U.S. Food and Drug Administration has approved 111In satumomab pendetide (OncoScint CR/OV; Cytogen Corporation, Princeton, NJ) for use in imaging colorectal and ovarian cancer. Immunoscintigraphy is being refined and tested to locate bony and soft-tissue metastases in patients with prostate cancer. As both a complementary tool and, in some cases, the imaging modality of choice, MoAbs have proven to be safe, accurate imaging tools for many patients with cancer.

Antibodies, Monoclonal↗

Quantitative contrast media dose evaluation for cranial computed tomography.

The goal of this study was to quantitatively evaluate the CT enhancement characteristics of selected intracranial blood vessels using four different volumes of a contrast medium under otherwise identical conditions in order to help determine a cost-effective dose. In a double blind, prospective manner, 100 patients referred for contrast-enhanced cranial CT were randomly assigned to receive one of four different volumes (50, 75, 100 or 120 ml) of ioversol 320 mg I/ml which was subsequently administered intravenously at a rate of 1 ml/s via a power injector. Unenhanced images were also obtained. Scanning times, slice thickness and other parameters were identical in all patients. Scanning was initiated immediately following delivery of the full volume of contrast. Region of interest Hounsfield unit measurements were acquired in a standardized manner using a 1 mm diameter circle on the pre- and post-contrast scans of the supraclinoid left internal carotid artery (LICA), supraclinoid right internal carotid artery (RICA), basilar artery (BA), and torcular region (TR). The mean enhancement value (in Hounsfield units) for the 50 ml, 75 ml, 100 ml and 120 ml dose groups respectively were as follows for each vessel: LICA 29.9, 41.5, 63.9, 64.6; RICA 30.1, 39.4, 62.6, 65.1; BA 30.0, 41.7, 66.0, 71.9; TR 31.7, 46.8, 68.9, 74.3. There was no statistically significant (p > 0.05) difference in enhancement in any of the four vessels when the 120 ml volume was delivered compared to the 100 ml volume. However, there was a statistically significant (p < 0.05) improvement in enhancement in all four vessels when 100 ml of contrast was administered compared to 75 ml.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗