Column selectivity in reversed-phase liquid chromatography III. The physico-chemical basis of selectivity.

Reversed-phase liquid chromatography (RP-LC) retention data for 23 additional solutes have been acquired to further test and evaluate a general relationship from part I: log alpha = log (k/kref) = eta'H(i) + sigma'S(ii) beta'S(iii) + alpha'B(iv) +kappa'C(v) The physico-chemical origin of terms i-v above is examined here by comparing values of (a) the solute parameters of Eq. (1) (eta', sigma', etc.) vs. solute molecular structure, and (b) the column parameters (H, S, etc.) vs. column properties (ligand length and concentration, pore diameter, end-capping). We conclude that terms i-v correspond, respectively, to hydrophobic (i), steric (ii), hydrogen bonding (iii, iv) and ionic (v) interactions between solute and stationary phase. While steric interaction (term ii) is superficially similar to what previously has been defined as "shape selectivity", the role of the solute and column in determining steric selectivity (term ii) appears more complex than previously proposed for "shape selectivity". Similarly, what has previously been called hydrogen bonding between donor solutes and an acceptor group in the stationary phase (term iv) is very likely an oversimplification.

Chromatography, Liquid↗

Preliminary evaluation of a standard reference material for chiral stationary phases used in liquid and supercritical fluid chromatography.

The applicability of a new Standard Reference Material (SRM) for the evaluation of chiral stationary phase (CSP) performance was demonstrated by utilizing the SRM to characterize the chromatographic behavior of eight commercially available CSPs in liquid and supercritical fluid chromatography. The SRM consists of five ethanolic solutions, each containing one chiral compound. These test mixtures can be used to assess changes in column performance over time and to evaluate lot-to-lot variability in column manufacturing. The SRM was also used to probe the effect of various parameters on column performance.

Journal Article↗

Analysis of lycopene geometrical isomers in biological microsamples by liquid chromatography with coulometric array detection.

Methods of analysis for determining low quantities of lycopene cis-trans isomers in biological tissues are needed. Development of two liquid chromatography (LC) methods based on the polymeric C30 stationary phase equipped with coulometric electrochemical array detection (ED) is described. Separation of 13 lycopene isomers including prolycopene, (a novel tetra-cis-lycopene found in Tangerine tomatoes) was accomplished with both isocratic and gradient methods using different proportions of methanol, methyl tert.-butyl ether, water and 1 M ammonium acetate buffer. Carotenoids were detected at potential settings between 200 and 620 mV. Differences in generated current-voltage curves aided in tentative identification of trans carotenoid species and select cis isomers of lycopene. These methods were successfully applied in the analysis of small quantities of plasma, buccal mucosal cells, prostate and cervical tissues. Limits of detection for trans-lycopene by ED were found to be 50 fmol representing a 10- to 100-fold increase over conventional UV-Vis absorbance methods.

Carotenoids↗

Poly(ethylene-co-acrylic acid) stationary phases for the separation of shape-constrained isomers.

A new approach for the synthesis of long alkyl chain length stationary phases for use in reversed-phase liquid chromatography is described. Poly(ethylene-co-acrylic acid) copolymers (i.e., (-CH2CH2-)x[CH2CH(CO2H)-]y) with different levels of acrylic acid were covalently bonded to silica via glycidoxypropyl or aminopropyl linkages. 13C cross polarization magic angle spinning (CP/MAS) nuclear magnetic resonance (NMR) spectroscopy was used to characterize the new reversed-phase materials. Aspects of shape selectivity were evaluated for six different columns with Standard Reference Material (SRM) 869a, Column Selectivity Test Mixture for Liquid Chromatography. Selectivity for isomer separations was enhanced for stationary phases prepared with poly(ethylene-co-acrylic acid) containing a mass fraction of 5% acrylic acid. The relationship between alkyl conformation and chromatographic properties was studied by 13C magic angle spinning (MAS) NMR measurements, and correlations were made with the composition of the polymer. Finally, the effectiveness of this phase is demonstrated by the separation of several beta-carotene isomers.

Acrylic Resins↗

Stationary phases for capillary electrochromatography.

This review summarizes the variety of stationary phases that have been employed for capillary electrochromatography (CEC) separations. Currently, about 70% of reported CEC research utilizes C18 stationary phases designed for liquid chromatography, but an increasing number of new materials (e.g., ion-exchange phases, sol-gel approaches, organic polymer continuous beds) are under development for use in CEC. Novel aspects of these different materials are discussed including the ability to promote electroosmotic flow, phase selectivity and activity for basic solutes. In addition, new column designs (polymer continuous beds and silica-sol-gel monoliths) are described.

Anion Exchange Resins↗

C30 stationary phases for the analysis of food by liquid chromatography.

The introduction of a polymeric C30 liquid chromatographic column by Sander et al. [Anal. Chem., 66 (1994) 1667] designed for the separation of carotenoid isomers, has led to the development of improved analytical methods for these compounds. Subsequent commercial availability of polymerically bonded C30 columns has facilitated these advances, and applications to a wide variety of separation problems with biological samples have been described. This report provides a comprehensive review of applications of polymeric C30 columns, utilized in the determination of carotenoids, retinoids, and other nutrients and related compounds in complex, natural-matrix samples.

Carbon↗

Reversed-phase liquid chromatographic separation of complex samples by optimizing temperature and gradient time III. Improving the accuracy of computer simulation.

Previous studies have shown that four experimental runs, where both temperature T and gradient time tG are varied, can be used for the reliable prediction of separation as a function of these two variables (two-dimensional optimization). Computer simulation (e.g., DryLab) can then be used to predict "optimized" conditions for maximum sample resolution using either isocratic or gradient elution. Samples that contain a large number of components (e.g., n>15-20) present a greater challenge. Resolution for these more complex samples is often quite sensitive to small changes in T or tG in turn requiring greater accuracy in predictions that result from computer simulation. In the present study of several samples, we have examined computer simulation errors that can arise from inexact expressions for retention time as a function of T, tG or isocratic %B. Resulting conclusions are applicable to both complex and simpler samples, in either one- or two-dimensional optimization. Means to anticipate and minimize the impact of these predictive errors are examined.

Chromatography, Liquid↗

Chiral selectors from fruit: application of citrus pectins to enantiomer separations in capillary electrophoresis.

Pectins were investigated as chiral selective agents in capillary electrophoresis. Successful enantioresolution of antihistaminic and antimalarial compounds, as well as others, was achieved by utilizing potassium polypectate as the chiral selector. Changes in pH, chiral additive concentration and capillary type were studied in relation to chiral resolution. The effect of degree of esterification of pectin materials on chiral recognition was also evaluated.

Electrophoresis, Capillary↗

Precolumn affinity capillary electrophoresis for the identification of clinically relevant proteins in human serum: application to human cardiac troponin I.

An approach has been developed to the on-line extraction and identification of clinical disease-state marker proteins in human serum. Fabrication of capillaries with integral packed beds for the online determination of human cardiac troponin I (cTnI), a diagnostic marker for myocardial infarction, at clinically relevant levels (2 nmol/L) in serum is demonstrated. The technique, termed precolumn affinity capillary electrophoresis (PA-CE), utilizes a short (approximately 5 mm) packed bed of porous silica containing covalently immobilized monoclonal anti-cTnI antibodies directly integrated within a separation capillary for the selective retention of cTnI from a complex matrix. Following a rinsing step to eliminate nonspecifically bound serum proteins and other impurities from the column, desorption of the antigen into the separation region of the PA-CE capillary for subsequent measurement of femto-molar amounts of cTnI by CE is effected by the injection of an appropriate elution buffer. Advantages of this approach over previously reported affinity preconcentration techniques, related applications for PA-CE technology, and its potential for use in the development of a certified reference material for cTnI in serum are discussed.

Blood Proteins↗

Coupled achiral/chiral column techniques in subcritical fluid chromatography for the separation of chiral and nonchiral compounds.

A multicolumn approach was developed to address the limited achiral selectivity of chiral stationary phases. Groups of structurally related compounds, including beta-blockers and 1,4-benzodiazepines, were separated using coupled achiral/chiral stationary phases under subcritical fluid conditions. The achiral selectivity of amino and cyano stationary phases was used to modify the resolution of compounds on a Chiralcel OD chiral stationary phase by combining the achiral and chiral columns in series. In the case of the benzodiazepines, separation of achiral compounds was performed concurrently with the enantioseparation of chiral molecules. The separation of components of a multidrug cough and cold medication was also demonstrated on a cyano column coupled with a Chiralpak AD chiral stationary phase. The use of modified carbon dioxide eluents eliminated the mobile phase incompatibility problems associated with column coupling in liquid chromatography and incorporated the high efficiency of sub- and supercritical fluid chromatography.

Adrenergic beta-Antagonists↗

Carotenoid determination in biological microsamples using liquid chromatography with a coulometric electrochemical array detector.

Numerous epidemiological studies have linked carotenoids to cancer preventive processes, thereby increasing interest in levels of these micronutrients in human tissue and serum. Conventional analyses of these biological tissues employ liquid chromatography (LC) with ultraviolet and visible absorbance (UV-VIS) detection. However, this type of carotenoid analysis does not provide adequate sensitivity for very small sample sizes, such as microscale biopsies, when only small quantities of tissue are available. Electrochemical detection (ECD) is a useful alternative to conventional UV-VIS detection methods for LC analysis of carotenoids in cases where high sensitivity is necessary. Both hydrocarbon (beta-carotene and alpha-carotene) and oxygenated carotenoids (lutein, zeaxanthin, and beta-cryptoxanthin) were detected at electrical potential settings between 220 and 520 mV. The generated electrochemical array data (hydrodynamic voltammograms) can be used to identify carotenoids as well as to differentiate between trans and cis configurations. Detection limits for beta-carotene by ECD were measured at 10 fmol representing approximately a 100- to 1000-fold increase over conventional LC-UV-VIS techniques. The developed methodology was applied successfully to microscale analysis of biological tissues.

Carotenoids↗

Selection of column and gradient elution system for the separation of catechins in green tea using high-performance liquid chromatography.

A study of a variety of stationary phases and elution conditions for the liquid chromatographic (LC) determination of six biologically active green tea catechins has resulted in the development of two well-defined, reproducible systems for such analyses which overcome limitations of previously described methods. Comparison of six reversed-phase columns indicates that deactivated stationary phases, which utilize ultrapure silica and maximize coverage of the silica support, provide significantly improved separation and chromatographic efficiencies for catechin analyses using LC, compared to conventional monomeric or polymeric C18 columns. Evaluation of elution conditions used for the separations reveals that the presence of acid in the mobile phase (0.05% trifluoroacetic acid) is essential for both the complete resolution of the catechins present in tea and the efficient chromatography of these compounds. The efficacy of one of the developed systems was demonstrated by the quantitative measurement of the six biologically active catechins in aqueous infusions of green tea (Camellia sinensis). Overall precision values for the analyses were within the range 0.3-1% (relative standard deviation).

Catechin↗

Capillary liquid chromatography/electrospray mass spectrometry for the separation and detection of catechins in green tea and human plasma.

The separation and detection of biologically active green tea catechins has been accomplished using capillary liquid chromatography/electrospray mass spectrometry (cLC/ESI-MS). Microscale determination (approximately 20 ng) of all six catechins in a green tea infusion, and the most extensively studied catechin, (-)epigallocatechin gallate (EGCG), in human plasma is demonstrated by cLC/ESI-MS with selected ion monitoring of protonated molecular ions. The overall quality of the analysis is shown to be dependent on the use of a capillary column with a deactivated, monomeric C18 stationary phase. The high chromatographic separation efficiency of this packed-capillary column, combined with the high sensitivity and selectivity afforded by the mass spectrometer as detector, provide a reliable approach to the analysis of picomolar quantities of these interesting compounds in complex matrices.

Catechin↗

Comparison of liquid and supercritical fluid chromatography for the separation of enantiomers on chiral stationary phases.

Comparisons of liquid (LC) and supercritical fluid chromatography (SFC) were conducted using commercially available chiral stationary phases (CSPs) bearing three different types of chiral selectors. Chiral compounds of pharmaceutical and agricultural interest were used to probe advantages of limitations of SFC relative to LC for enantiomeric separations. Column equilibrium and parameter optimization were generally accomplished more rapidly in SFC than in LC. Although improved resolution was often observed in SFC, analysis times were not always lower in SFC than in LC. In some instances, SFC provided separation capabilities not readily accessible in LC.

Chromatography, Liquid↗

Stationary interphases with extended alkyl chains: a comparative study on chain order by solid-state NMR spectroscopy.

Stationary interphases with long n-alkyl chains (n = 18, 22, 30, 34) have been examined by solid-state NMR spectroscopy. The determination of the silane functionality and the degree of cross-linking of silane ligands on the silica surface was performed by 29Si CP/MAS NMR spectroscopy. High-speed 1H MAS and 13C CP/MAS NMR spectroscopy were utilized to assess alkyl chain order and mobility of the different bonded phases. For this purpose, 1H NMR line widths and 13C chemical shifts have been evaluated. It is shown that stationary phase order and rigidity increase with alkyl chain length. In addition, the temperature-dependent trans/gauche conformational change occurs at higher temperatures for a polymeric C34 phase compared with a C30 sorbent. This behaviour is discussed in the context of previously reported chromatographic (HPLC) shape selectivity differences.

Carbon Isotopes↗

Combined use of temperature and solvent strength in reversed-phase gradient elution. I. Predicting separation as a function of temperature and gradient conditions.

It has been shown previously that computer simulation based on two initial experiments can predict separation in reversed-phase gradient elution as a function of gradient conditions (gradient steepness, gradient range and gradient shape) and column conditions (column length, flow-rate and particle size). The present study extends this capability for changes in temperature. Four initial experiments (two different gradient times, two different temperatures) provide input data that allow predictions of separation as a function of temperature as well as gradient and column conditions. A semi-empirical relationship, tR = a + bT, is able to relate gradient retention time tR to column temperature T (other conditions constant). The accuracy of this approach has been evaluated for 102 solutes and a variety of experimental conditions, including the use of five different HPLC instruments (four different models).

Chromatography, High Pressure Liquid↗

Liquid chromatographic determination of carotenoids in human serum using an engineered C30 and a C18 stationary phase.

A C30 stationary phase was specifically engineered for carotenoid separations, and carotenoid measurements using this column are compared with those obtained using a somewhat more conventional C18 column. Both methods were used to contribute measurements for the certification of carotenoids in Standard Reference Material 968b, Fat-Soluble Vitamins and Cholesterol in Human Serum. Analytes were extracted from the serum into hexane. Measurements on the C18 column were made using a gradient of acetonitrile, methanol, and ethyl acetate, which is described in detail elsewhere. Measurements on the C30 column were made using a gradient of water, methanol, and methyl tert.-butyl ether.

Carotenoids↗

Isolation and structural elucidation of the predominant geometrical isomers of alpha-carotene.

The recent development and application of a polymeric C30 stationary phase have given unique separations of cis-trans carotenoid isomers in reversed-phase (RP) liquid chromatography (LC) owing to the exceptional shape selectivity of this stationary phase. In the present research, several geometrical isomers of alpha-carotene were at least partially resolved from a photo-isomerized mixture when chromatographed on a 3-microns polymeric C30 column. Double bond configurations of the five predominant alpha-carotene peaks, as isolated on a semi-preparative C30 column, were unambiguously assigned using 1H nuclear magnetic resonance (NMR) spectroscopy, giving the following order of elution: 13-cis, 13'-cis, all-trans, 9-cis, and 9'-cis geometrical forms. Electronic absorption spectra for these isomers were in agreement with the identification of peaks. The alpha-carotene isomers separated and identified herein had not been previously resolved in RPLC. Confirmation of the structures of geometrical alpha-carotene isomers will aid further studies on the possible physiological roles of these compounds in biological tissues.

Carotenoids↗