Double-blind comparison of butorphanol and meperidine in the treatment of post-surgical pain.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to L C Stehling.
Explore the source record for details and available documents.
Butorphanol tartrate, a synthetic morphinan which has analgesic agonist and antagonist properties, was compared with meperidine for balanced anaesthesia. The two agents were found to be comparable in efficacy, maintenance of cardiovascular stability, and incidence of side-effects. Butorphanol has the advantage of being non-narcotic and having a lower propensity for addiction. Because of its antagonist properties, there appears to be a limit to its depressant effects on respiration.
Over a 7-yr period from January 1967 to January 1974, 141 patients underwent thyroid surgery for various pathology at the Bexar County Hospital - University of Texas Medical School at San Antonio. Of these, 113 patients underwent subtotal thyroidectomy for benign diseases, including 28 of thyrotoxic patients who underwent subtotal thyroidectomy as definitive treatment. In this group of patients special interest and emphasis was placed in the preoperative and intraoperative management of the difficult and complicated hyperthyroid patient. Preoperative treatment was accomplished by the utilization of multiple drug combinations - including antithyroid drugs, adrenergic blocking agents, and iodine - which resulted in significant decrease in preparation time for surgery. Furthermore, this short intensive preoperative management of complicated hyperthyroid patients allowed satisfactory correction of their problems with little or no morbidity which otherwise would have been extremely difficult if not impossible to resolve. At operation, 28 patients were diagnosed to have malignant disease; 23 underwent total thyroidectomy and the other 5 had subtotal thyroidectomy. In addition to total or subtotal thyroidectomy, 23 patients had either classical or modified radical neck dissection including 9 patients who had bilateral neck dissection. The various surgical techniques utilized, the rationale for rapid preoperative preparation of complicated hyperthyroid patients, morbidity, and long-term follow-up are discussed.
Explore the source record for details and available documents.
Studies of risk factors associated with reactions among autologous blood donors have been limited. Therefore, 2091 autologous and 4737 homologous donations were examined. Donors at greatest risk for reaction were autologous donors who had reactions at first donation; among 45 who made repeat donations for the same surgery, 17 (38%) had repeat reactions. The group least likely to experience reactions were the autologous donors greater than or equal to 66 years old; they experienced a 1.9 greater than or equal to percent (6/310) incidence of reactions. More reactions were seen in both autologous and homologous donors in the categories of first-time donor, female gender, decreasing age, and lower weight. Multiple logistic regression analysis showed that all of these variables were independent predictors of donor reaction, with first-time donation (odds ratio, 2.4) and female gender (odds ratio, 1.9) being the strongest predictors of reaction. Donor room personnel should be alerted that autologous donors who react at first donation are very likely to react at subsequent donations. Contrary to common concern, elderly autologous donors are least likely to have reactions.
Patients with serious illnesses who donate their blood for autologous use create anxiety for many phlebotomists. Donor room staff were surveyed at three donor centers, using confidential questionnaires, to identify their concerns and to evaluate factors associated with reduced anxiety toward autologous donors. Among respondents (n = 93), 58 percent had patient care experience within the last 5 years, which correlated with diminished concern about phlebotomizing cardiac patients (r = .21; p = 0.04). Fifty-seven percent of respondents had drawn blood from greater than 50 autologous donors. Surprisingly, the experience of drawing blood from relatively large numbers of autologous donors did not correlate with increased confidence in phlebotomizing pediatric, cardiac, and elderly patients (r = -.04; p = 0.75). Those respondents who felt that they had adequate medical support agreed with more liberal donor criteria and were more confident about phlebotomizing pediatric, cardiac, and elderly patients (r = -.32; p = 0.001). Those respondents who believed most strongly in the benefits of autologous transfusion had the least anxiety toward donors who were medically more complex (r = .39; p = 0.0001). It is concluded that, contrary to what might be expected, phlebotomizing large numbers of autologous donors does not reduce the anxiety of staff members when they encounter donors with complex medical problems. Factors that do reduce anxiety include dependable physician and other medical support services, previous experience in direct patient care, and knowledge of the benefits of autologous transfusion.
Preoperative autologous blood donation is used by only a small percentage of surgery patients for whom crossmatched blood is ordered. To document the reasons the patients failed to donate, the medical records of surgical patients at three university and three community hospitals were studied. All procedures for which crossmatched blood was ordered, but for which autologous blood was not available, were included (n = 8121). Probable reasons for nondonation were found in 72 percent of university hospital patients and 65 percent of community hospital patients (n = 6064 and n = 2057, respectively). The most frequent reasons for nondonation among university hospital patients were emergency surgery (27%) and age less than 12 years (17%), and those among community hospital patients were emergency surgery (42%) and American Society of Anesthesiologists physical status greater than or equal to 4 (20%). Surprisingly, anemia (hemoglobin less than 11 g/dL [less than 110 g/L]) as the only limitation to donation was rarely found: this was the sole reason in only 3.3 percent of university hospital and 4.5 percent of community hospital patients. Overall, of 8121 patients who failed to donate autologous blood, 5731 (71%) had legitimate medical reasons. The remaining 2390 (29%) had no identifiable reason for nondonation, and recruitment efforts should be focused on them and their surgeons.
Preoperative autologous blood donation for elective surgery patients at university hospitals was underused in the past. More recently, national educational efforts have been made. To test the impact of local surgeon interviews and education, in 1988 the same local educational program was instituted at three university hospitals; three community hospitals were used as controls. Donation by appropriate patients of interviewed surgeons (elective surgery, crossmatch recommended, no contraindications to donation) increased from 24 percent (44/180) to 40 percent (88/222) (p = 0.002) and 15 percent (21/143) to 32 percent (41/127) (p = 0.001) at two university hospitals where the investigator-educators were on site, but not at the three community hospitals. Between 1987 and 1989, donation rates at all six hospitals remained low among patients for whom autologous donation was (probably) less appropriate. Donation rates for type and screen procedures were 3.0 percent (131/4587) in 1987 and 3.0 percent (199/6606) in 1989 (p = 0.67). Donation rates for "no blood order" procedures were 0.2 percent (15/9429) in 1987 and 0.1 percent (9/11,239) in 1989 (p = 0.14). It can be concluded that appropriate autologous blood donations increased at university hospitals where surgeons were individually interviewed and educated by an investigator on site. However, despite this increase, apparently eligible elective surgery patients in 1989 still failed to donate. This situation deserves additional investigation.
The effect of enflurane on uterine contractility was studied in sexually mature rabbits in which intrauterine balloon catheters had been implanted. Three animal groups were studied: untreated; treated with estrogen-progesterone; and 27 to 28 days pregnant. The effects of 1.5 percent or 3.0 percent enflurane were quantitated by measuring contraction frequency and amplitude during an anesthetically steady state. The effects of prior anesthesia with 1.5 percent enflurane on uterine responses to 1.5 IU oxytocin IV were also evaluated. Neither 1.5 percent of 3.0 percent enflurane altered contraction amplitude or frequency in the 3 groups of rabbits. However, the amplitude of the contractile response to oxytocin 30 minutes following enfluane was significantly depressed. The results indicate that, while the intact rabbit uterus under different hormonal influences is not depressed by 1.5 or 3.0 percent enflurane, its response to oxytocin following enflurane is decreased.