Human postural response to lower leg muscle vibration of different duration.

Body lean response to bilateral vibrations of soleus muscles were investigated in order to understand the influence of proprioceptive input from lower leg in human stance control. Proprioceptive stimulation was applied to 17 healthy subjects by two vibrators placed on the soleus muscles. Frequency and amplitude of vibration were 60 Hz and 1 mm, respectively. Vibration was applied after a 30 s of baseline. The vibration duration of 10, 20, 30 s respectively was used with following 30 s rest. Subjects stood on the force platform with eyes closed. Postural responses were characterized by center of pressure (CoP) displacements in the anterior-posterior (AP) direction. The CoP-AP shifts as well as their amplitudes and velocities were analyzed before, during and after vibration. Vibration of soleus muscles gradually increased backward body tilts. There was a clear dependence of the magnitude of final CoP shift on the duration of vibration. The amplitude and velocity of body sway increased during vibration and amplitude was significantly modulated by duration of vibration as well. Comparison of amplitude and velocity of body sway before and after vibration showed significant post-effects. Presented findings showed that somatosensory stimulation has a long-term, direction-specific influence on the control of postural orientation during stance. Further, the proprioceptive input altered by soleus muscles vibration showed significant changes in postural equilibrium during period of vibration with interesting post-effects also.

Adult↗

Periodical in-situ re-calibration of force platforms: a new method for the robust estimation of the calibration matrix.

The paper provides a new technique based on a least-squares approach for the accurate estimation of a force platform calibration matrix using simple manual procedures, when the direction of the applied loads cannot be perfectly aligned with the axes of the platform. This new procedure can be applied to all force platforms and allows the combined application of vertical and horizontal forces, both static and time-varying. The robust calibration method includes the angular errors in the least-squares parameter vector, thus reducing the bias in the estimated calibration matrix parameters. The performance of the robust method was compared with the conventional one, using a numerical simulation approach starting from a known calibration matrix. With the conventional approach, in noiseless conditions, the maximum error due to load misalignment (SD = 3 degrees) was 6% for the direct terms and over 10% for the cross-talk terms. With the robust method, these errors reduced to zero and were always below 0.4%, even when realistic noise was superimposed on the measures. With perfectly aligned loads and realistic output noise, the confidence intervals of the calibration matrix parameters were very similar for the two methods, demonstrating that the increased number of parameters did not affect the reliability of the estimate.

Biomechanical Phenomena↗

Feature selection of stabilometric parameters based on principal component analysis.

This study addresses the challenge of identifying the features of the Centre of pressure (COP) trajectory that are most sensitive to postural performance, with the aim of avoiding redundancy and allowing a straightforward interpretation of the results. Postural sway in 50 young, healthy subjects was measured by a force platform. Thirty-seven stabilometric parameters were computed from the one-dimensional and two-dimensional COP time series. After normalisation to the relevant biomechanical factors, by means of multiple regression models, a feature selection process was performed based on principal component analysis. Results suggest that COP two-dimensional time series can be primarily characterised by four parameters, describing the size of the COP path over the support surface; the principal sway direction; and the shape and bandwidth of the power spectral density plot. COP one-dimensional time series (antero-posterior (AP) and medio-lateral (ML)) can be characterised by six parameters describing COP dispersion along the AP direction; mean velocity along the ML and AP directions; the contrast between ML and AP regulatory activity; and two parameters describing the spectral characteristics of the COP along the AP direction. On the basis of the results obtained, some guidelines are suggested for the choice of stabilometric parameters to use, with the aim of promoting standardisation in quantitative posturography.

Adult↗

Effects of deep brain stimulation and levodopa on postural sway in Parkinson's disease.

OBJECTIVE: To quantify postural sway in subjects with Parkinson's disease and elderly controls, and determine the effects of Parkinson's disease, deep brain stimulation, levodopa, and their interactions on postural control during quiet stance. METHODS: Centre of foot pressure (CoP) displacement under each foot was measured during three 60 s trials of quiet stance with eyes open in 11 controls and six patients with Parkinson's disease. Subjects with Parkinson's disease were tested in four treatment conditions: off both deep brain stimulation and levodopa (off condition); on deep brain stimulation; on levodopa; and on both deep brain stimulation and levodopa. The variables extracted from CoP included: root mean square distance (rms), mean velocity, 95% power frequency (f(95%)), area of the 95% confidence ellipse (ellipse area), direction of its major axis (mdir), and postural asymmetry between the feet. RESULTS: rms and area of postural sway were larger than normal in subjects with Parkinson's disease in the off condition, increased further with levodopa, and significantly decreased with deep brain stimulation. Mean velocity and f(95%) were also larger than normal but were restored to normal by all treatments, especially by deep brain stimulation. The combined effect of deep brain stimulation and levodopa resulted in a postural sway that was an average of the effect of each treatment individually. Levodopa increased sway more in the mediolateral than in the anterior-posterior direction. Subjects with Parkinson's disease had asymmetrical mean velocity and f(95%) between the feet, and this asymmetry increased with levodopa but decreased with deep brain stimulation. The f(95%) of the CoP correlated with tremor, posture, and gait subcomponents of the unified Parkinson's disease rating scale. CONCLUSIONS: Subjects with Parkinson's disease have abnormal postural sway in stance. Treatment with levodopa increases postural sway abnormalities, whereas treatment with deep brain stimulation improves postural sway. Quantitative evaluation of static posturography may be a useful adjunct to clinical measures in patients with Parkinson's disease.

Aged↗

Comparison of logistic and Bayesian classifiers for evaluating the risk of femoral neck fracture in osteoporotic patients.

Femoral neck fracture prediction is an important social and economic issue. The research compares two statistical methods for the classification of patients at risk for femoral neck fracture: multiple logistic regression and Bayes linear classifier. The two approaches are evaluated for their ability to separate femoral neck fractured patients from osteoporotic controls. In total, 272 Italian women are studied. Densitometric and geometric measurements are obtained from the proximal femur by dual energy X-ray absorptiometry. The performances of the two methods are evaluated by accuracy in the classification and receiver operating characteristic curves. The Bayes classifier achieves an accuracy approximately 1% higher than that of the multiple logistic regression. However, the performances of the two methods, evaluated by the area under the curves, are not statistically different. The study demonstrates that the Bayes linear classifier can be a valid alternative to multiple logistic regression in the classification of osteoporotic patients.

Aged↗

An improved technique for the extraction of stochastic parameters from stabilograms.

An improved characterization of the dynamics of postural sway can provide a better understanding about the functional organization of the postural control system as well as a more robust tool for postural pattern recognition. To this aim, a novel parameterization was applied to the stabilogram diffusion analysis formerly proposed by Collins and De Luca [Collins JJ, De Luca CJ. Open-loop and closed-loop control of posture: a random-walk analysis of center-of-pressure trajectories. Exp Brain Res 1993;95:308-18] that considered the act of maintaining posture as a stochastic process. The main purpose of the present technique was to overcome some drawbacks of the model presented by Collins and De Luca that may restrain its potential application in clinical practice. The approach uses a unique non-linear model to describe the center of pressure (COP) dynamics that reduces the number of parameters and decreases their intra-subject variability; consequently, fewer trials are required to perform reliable estimates of stochastic parameters and this is of particular importance for subjects that cannot afford many repeated measurements because of age or pathology. Four new statistical mechanics parameters (NSMP) were computed on the log-log stabilogram diffusion plots and their estimates were compared in terms of reliability and sensitivity to the visual conditions with: (1) a minimal set of four summary statistic scores (SSS); and (2) the six statistical mechanics parameters (SMP) proposed by Collins and De Luca. All four NSMP showed at least a fair-to-good reliability (intraclass correlation coefficient, ICC>0.49) while SMP (ICC>0.20) showed some poor reliability. A better overall reliability was also observed with respect to SSS. Moreover, only NSMP had a similar score for eyes open and eyes closed conditions. Three out of four NSMP were also significantly sensitive to eyes open or closed conditions (P<0.001) while only three out of six SMP were sensitive to operating conditions (P<0.01).

Humans↗

Prediction of solute kinetics, acid-base status, and blood volume changes during profiled hemodialysis.

A mathematical model of solute kinetics oriented to the simulation of hemodialysis is presented. It includes a three-compartment model of body fluids (plasma, interstitial and intracellular), a two-compartment description of the main solutes (K+, Na+, Cl-, urea, HCO3-, H+), and acid-base equilibrium through two buffer systems (bicarbonate and noncarbonic buffers). Tentative values for the main model parameters can be given a priori, on the basis of body weight and plasma concentration values measured before beginning the session. The model allows computation of the amount of sodium removed during hemodialysis, and may enable the prediction of plasma volume and osmolarity changes induced by a given sodium concentration profile in the dialysate and by a given ultrafiltration profile. Model predictions are compared with clinical data obtained during 11 different profiled hemodialysis sessions, both with all parameters assigned a priori, and after individual estimation of dialysances and mass-transfer coefficients. In most cases, the agreement between the time pattern of model solute concentrations in plasma and clinical data was satisfactory. In two sessions, blood volume changes were directly measured in the patient, and in both cases the agreement with model predictions was acceptable. The present model can be used to improve the dialysis session taking some characteristics of individual patients into account, in order to minimize intradialytic unbalances (such as hypotension or disequilibrium syndrome).

Acid-Base Equilibrium↗

Mathematical modeling of solute kinetics and body fluid changes during profiled hemodialysis.

A mathematical model of solute kinetics oriented to improve hemodialysis treatment is presented. It includes a two-compartment description of the main solutes (K+, Na+, Cl-, urea, HCO3-, H+, CO2), acid-base equilibrium through two buffer systems (bicarbonate and non-carbonic buffers) and a three-compartment model of body fluids (plasma, interstitial and intracellular). The main model parameters can be individually assigned a priori, on the basis of body weight and plasma concentration values measured before beginning the session. Model predictions are compared with clinical data obtained during 11 different hemodialysis sessions performed on six patients with profiled sodium concentration in the dialysate and profiled ultrafiltration rate. In all cases, the agreement between the time pattern of model solute concentrations in plasma and clinical data turns out fairly good as to urea, sodium, chloride and potassium kinetics. Finally, the time patterns of plasma bicarbonate concentration and pH can be reproduced fairly well with the model, provided CO2 concentration remains constant. Only in two sessions, blood volume was directly measured in the patient, and in both cases the agreement with model predictions was good. In conclusion, the model allows a priori computation of the amount of sodium removed during hemodialysis, and may enable the prediction of plasma volume changes and plasma osmolarity changes induced by a given sodium concentration profile in the dialysate and by a given ultrafiltration profile. Hence, it can be used to improve the dialysis session taking the characteristics of individual patients into account, in order to minimize intradialytic imbalances (such as hypotension or disequilibrium syndrome).

Acid-Base Equilibrium↗

Model-based dialysis adequacy prediction by continuous dialysate urea monitoring.

A modeling approach for on-line estimation of urea kinetics from continuous measurement of urea concentration in the effluent dialysate stream (DUN) is presented. On-line identification of urea kinetics response parameters is used to predict and update dialysis adequacy during the treatment. Dialysis adequacy can be quantified in several ways, but its strict dependence on final urea concentration is a major fact. For this reason, a good predictive skill on the time course of DUN may enable better performances in the control of dialysis outcome by treatment parameters adjustment. A post-filter enzymatic sensor performs continuous measurement of DUN on patients undergoing standard haemodialysis. To get an early prediction of the end dialysis urea level, the solution of a variable volume double-pool (VVDP) model is used, whose parameters are identified at each time on the basis of the past DUN history Unlike the variable volume single-pool (VVSP) model, this enables a prompt and accurate estimation of the final DUN. In fact, after 75 min the estimates always differ by less than 10% from the values measured by the sensor at the end of the treatment. Moreover, values predicted by the model in the last hour always lie within 1% of measured final values. Real-time knowledge of an analytic expression for whole DUN time course also enables the accurate prediction of total removed urea, with no need of cumbersome dialysate collection techniques.

Aged↗

Autonomic nervous function during haemodialysis assessed by spectral analysis of heart-rate variability.

1. Short-term autonomic response to haemodialysis-induced hypovolaemia was studied in 30 patients undergoing chronic haemodialysis by analysing power spectra of heart-period variability. Patients were classified as haemodynamically stable (15 patients) and unstable (15 patients) according to their past history of cardiovascular collapse during the treatment. Blood volume, systolic arterial pressure and heart period were measured during sessions that ended without the occurrence of collapse. 2. No significant differences were observed when comparing blood volume, heart rate and arterial pressure of stable and unstable patients during the dialysis, and the two groups could not be distinguished merely on the basis of these haemodynamic parameters. Conversely, spectral analysis of beat-to-beat heart-period variability showed markedly different power patterns: in stable patients power was mainly in the low-frequency (LF) band (0.06-0.15 Hz), whereas in unstable patients it was mainly in the high-frequency (HF) band (0.15-0.4 Hz). 3. The efficiency of the autonomic response to hypovolaemia was evaluated by the ratio between the powers in the LF and HF bands. Stable patients exhibited an LF/HF power ratio systematically greater than unstable patients during the entire dialysis, and on the basis of this index the two groups were clearly separated. 4. Results obtained with spectral analysis lead us to conclude that reduced efficiency in the autonomic control of cardiovascular functions could be the main cause of the haemodynamic instability of patients prone to collapse.

Aged↗

Parametric analysis of heart rate variability during hemodialysis.

The problem of evaluating short-term autonomic response to hypovolemia in patients under chronic hemodialysis treatment is considered. Power spectra of the beat-to-beat heart rate variability were evaluated during the dialysis treatment in twenty hemodynamically stable and unstable patients, using a parametric technique. The autoregressive model coefficients were calculated by the modified covariance method, while model order was selected according to the minimum description length criterion. Reported results demonstrate that stable and unstable patients present markedly different spectral patterns. The efficiency of the compensatory response to hemodialysis-induced hypovolemia was evaluated through the ratio between the powers in LF and HF bands. Stable patients exhibit a LF/HF ratio greater than one with large fluctuations over the whole dialysis session. In contrast, all the unstable patients are characterized by a value of LF/HF lower than one and with a reduced time variability. This result suggests that the hemodynamic instability of the hypotension-prone patients may be due to a deficiency in the short-term compensatory response to the hemodialysis-induced hypovolemia.

Algorithms↗

Pilot trials on the treatment of Dermatobia hominis infections in cattle with closantel.

The therapeutic and prophylactic activities of closantel given to calves inoculated with larvae of Dermatobia hominis were studied. Calves (n = 9 principals, plus 3 nontreated controls) were given closantel at different dosages (8 to 12.5 mg/kg) and schedules of treatment. The largest dosage of closantel (12.5 mg/kg) had the most efficacious therapeutic activity (97.3%). Prophylactic activity was also seen in calves given the drug before they were experimentally inoculated.

Animals↗

Experimental muscular amebiasis in hamsters as a biological model.

Trophozoites of Entamoeba histolytica maintained in vitro in Pavlova's medium were inoculated by deep intramuscular injection into the proximal left hindleg of hamsters. Thioglycollate medium was utilized as a successful vehicle to induce the infection. The invasion of the muscular tissue by the vegetative forms caused the formation of abscesses with great destruction of muscular fibers. The lesions were limited to the muscular tissue of the femoral area. The number of trophozoites, the medium of thioglycollate as a vehicle, the volume of the inoculum and the trauma caused by the needle were important elements in the evolution of the muscular amebic abscesses. A limited trial of the amebicidal activity of metronidazole utilizing the amebic intramuscular infection was also performed.

Abscess↗

A new approach for tracking respiratory mechanical parameters in real-time.

A new recursive least-squares procedure for on-line tracking of changes in viscoelastic properties of respiratory mechanics is proposed and applied to artificially ventilated patients. Classical least-squares methods based on simple first-order linear models with time-constant parameters generally provide systematic residuals that hardly satisfy standard statistical tests for model validation in terms of residuals. On the other hand, high order and/or nonlinear models introduce parameters whose estimates are of difficult interpretation in a clinical context. The present procedure overcomes these limitations by using the well-known first-order model of respiratory mechanics, wherein variability of resistance and elastance during the breathing cycle is allowed to take into account nonlinear and high-order behavior. Mean and standard deviation of resistance and elastance estimates, relative to a respiratory cycle, are then determined recursively. Feasibility of the method is evaluated by applying it both to experimental and simulated pressure-airflow signals measured in an intensive care unit during mechanical ventilation of patients recovering from heart surgery. Results demonstrate that the proposed procedure provides data description satisfying statistical tests, such as residual whiteness, and reliable estimates of viscoelastic lung parameters even during substantial and fast variations in the respiratory status. In addition, unlike classical methods, the new technique provides the means for on-line evaluation of parameter variability during each respiratory cycle, by the estimate of their standard deviations. This is important in clinical practice, because only the knowledge of reliable parameter values and standard deviations enables significant changes in the respiratory viscoelastic characteristics, and thus in patient status, to be assessed.

Airway Resistance↗