Monte Carlo generated conversion factors for the estimation of average glandular dose in contact and magnification mammography.

Magnification mammography is a special technique used in the cases where breast complaints are noted by a woman or when an abnormality is found in a screening mammogram. The carcinogenic risk in mammography is related to the dose deposited in the glandular tissue of the breast rather than the adipose, and average glandular dose (AGD) is the quantity taken into consideration during a mammographic examination. Direct measurement of the AGD is not feasible during clinical practice and thus, the incident air KERMA on the breast surface is used to estimate the glandular dose, with the help of proper conversion factors. Additional conversion factors adapted for magnification and tube voltage are calculated, using Monte Carlo simulation. The effect of magnification degree, tube voltage, various anode/filter material combinations and glandularity on AGD is also studied, considering partial breast irradiation. Results demonstrate that the estimation of AGD utilizing conversion factors depends on these parameters, while the omission of correction factors for magnification and tube voltage can lead to significant underestimation or overestimation of AGD. AGD was found to increase with filter material's k-absorption edge, anode material's k-emission edge, tube voltage and magnification. Decrease of the glandularity of the breast leads to higher AGD due to the increased penetrating ability of the photon beam in thick breasts with low glandularity.

Air↗

Osteoarthritis severity of the hip by computer-aided grading of radiographic images.

A computer-aided classification system was developed for the assessment of the severity of hip osteoarthritis (OA). Sixty-four radiographic images of normal and osteoarthritic hips were digitized and enhanced. Employing the Kellgren and Lawrence scale, the hips were grouped by three experienced orthopaedists into three OA-severity categories: Normal, Mild/Moderate and Severe. Utilizing custom-developed software, 64 ROIs corresponding to the radiographic Hip Joint Spaces were manually segmented and novel textural features were generated. These features were used in the design of a two-level classification scheme for characterizing hips as normal or osteoarthritic (1st level) and as of Mild/Moderate or Severe OA (2nd level). At each classification level, an ensemble of three classifiers was implemented. The proposed classification scheme discriminated correctly all normal hips from osteoarthritic hips (100% accuracy), while the discrimination accuracy between Mild/Moderate and Severe osteoarthritic hips was 95.7%. The proposed system could be used as a diagnosis decision-supporting tool.

Aged↗

Assessing hip osteoarthritis severity utilizing a probabilistic neural network based classification scheme.

A computer-based classification system is proposed for the characterization of hips from pelvic radiographs as normal or osteoarthritic and for the discrimination among various grades of osteoarthritis (OA) severity. Pelvic radiographs of 18 patients with verified unilateral hip OA were evaluated by three experienced physicians, who assessed OA severity employing the Kellgren and Lawrence scale as: normal, mild/moderate and severe. Five run-length, 75 Laws' and 5 novel textural features were extracted from the digitized radiographic images of each patient's osteoarthritic and contralateral normal hip joint spaces (HJSs). Each one of the three sets of textural features (run-lengths, Laws' and novel features) was separately utilized for assigning hips into the three OA severity categories, by means of a probabilistic neural network (PNN) classifier based hierarchical tree structure. The highest classification accuracy (100%) for characterizing hips as normal, of mild/moderate or of severe OA was obtained for the novel textural features set. Additionally, the novel textural features were used to design a mathematical regression model for providing a quantitative estimation of OA severity. Measured OA severity values, as expressed by HJS-narrowing, correlated highly (r=0.85, p<0.001) with the predicted values by the mathematical regression model. The proposed system may be valuable in OA-patient management.

Aged↗

Suitability of new anode materials in mammography: dose and subject contrast considerations using Monte Carlo simulation.

Mammography is the technique with the highest sensitivity and specificity, for the early detection of nonpalpable lesions associated with breast cancer. As screening mammography refers to asymptomatic women, the task of optimization between the image quality and the radiation dose is critical. A way toward optimization could be the introduction of new anode materials. A method for producing the x-ray spectra of different anode/filter combinations is proposed. The performance of several mammographic spectra, produced by both existing and theoretical anode materials, is evaluated, with respect to their dose and subject contrast characteristics, using a Monte Carlo simulation. The mammographic performance is evaluated utilizing a properly designed mathematical phantom with embedded inhomogeneities, irradiated with different spectra, based on combinations of conventional and new (Ru, Ag) anode materials, with several filters (Mo, Rh, Ru, Ag, Nb, Al). An earlier developed and validated Monte Carlo model, for deriving both image and dose characteristics in mammography, was utilized and overall performance results were derived in terms of subject contrast to dose ratio and squared subject contrast to dose ratio. Results demonstrate that soft spectra, mainly produced from Mo, Rh, and Ru anodes and filtered with k-edge filters, provide increased subject contrast for inhomogeneities of both small size, simulating microcalcifications and low density, simulating masses. The harder spectra (W and Ag anode) come short in the discrimination task but demonstrate improved performance when considering the dose delivered to the breast tissue. As far as the overall performance is concerned, new theoretical spectra demonstrate a noticeable good performance that is similar, and in some cases better compared to commonly used systems, stressing the possibility of introducing new materials in mammographic practice as a possible contribution to its optimization task. In the overall optimization task in terms of subject contrast to dose ratio, tube voltage was found to have a minor effect, while with respect to the filter material, a lesion specific performance was noticed, with Al filtered spectra showing improved characteristics in case of the inhomogeneities simulating microcalcifications, while softer k-edge filtered spectra are more suitable for the discrimination of inhomogeneities simulating masses.

Computer Simulation↗

Evaluating the effect of a wavelet enhancement method in characterization of simulated lesions embedded in dense breast parenchyma.

Presence of dense parenchyma in mammographic images masks lesions resulting in either missed detections or mischaracterizations, thus decreasing mammographic sensitivity and specificity. The aim of this study is evaluating the effect of a wavelet enhancement method on dense parenchyma for a lesion contour characterization task, using simulated lesions. The method is recently introduced, based on a two-stage process, locally adaptive denoising by soft-thresholding and enhancement by linear stretching. Sixty simulated low-contrast lesions of known image characteristics were generated and embedded in dense breast areas of normal mammographic images selected from the DDSM database. Evaluation was carried out by an observer performance comparative study between the processed and initial images. The task for four radiologists was to classify each simulated lesion with respect to contour sharpness/unsharpness. ROC analysis was performed. Combining radiologists' responses, values of the area under ROC curve (Az) were 0.93 (95% CI 0.89, 0.96) and 0.81 (CI 0.75, 0.86) for processed and initial images, respectively. This difference in Az values was statistically significant (Student's t-test, P<0.05), indicating the effectiveness of the enhancement method. The specific wavelet enhancement method should be tested for lesion contour characterization tasks in softcopy-based mammographic display environment using naturally occurring pathological lesions and normal cases.

Breast↗

A wavelet-based spatially adaptive method for mammographic contrast enhancement.

A method aimed at minimizing image noise while optimizing contrast of image features is presented. The method is generic and it is based on local modification of multiscale gradient magnitude values provided by the redundant dyadic wavelet transform. Denoising is accomplished by a spatially adaptive thresholding strategy, taking into account local signal and noise standard deviation. Noise standard deviation is estimated from the background of the mammogram. Contrast enhancement is accomplished by applying a local linear mapping operator on denoised wavelet magnitude values. The operator normalizes local gradient magnitude maxima to the global maximum of the first scale magnitude subimage. Coefficient mapping is controlled by a local gain limit parameter. The processed image is derived by reconstruction from the modified wavelet coefficients. The method is demonstrated with a simulated image with added Gaussian noise, while an initial quantitative performance evaluation using 22 images from the DDSM database was performed. Enhancement was applied globally to each mammogram, using the same local gain limit value. Quantitative contrast and noise metrics were used to evaluate the quality of processed image regions containing verified lesions. Results suggest that the method offers significantly improved performance over conventional and previously reported global wavelet contrast enhancement methods. The average contrast improvement, noise amplification and contrast-to-noise ratio improvement indices were measured as 9.04, 4.86 and 3.04, respectively. In addition, in a pilot preference study, the proposed method demonstrated the highest ranking, among the methods compared. The method was implemented in C++ and integrated into a medical image visualization tool.

Algorithms↗

Visually lossless threshold determination for microcalcification detection in wavelet compressed mammograms.

The aim of this study was to determine the visually lossless threshold of a wavelet-based compression algorithm in case of microcalcification cluster detection in mammography. The threshold was determined by means of observer performance using a set of digitized mammograms. In addition, the transfer characteristics of the compression algorithm were assessed by means of image-quality parameters using computer-generated test images. The observer performance study was based on rating performed by four independent radiologists, who reviewed 68 mammograms, from the Digital Database for Screening Mammography (DDSM), at six different compression ratios. Receiver operating characteristics (ROC) analysis was performed on observers' responses and the area under ROC curve (A(z)) was calculated at each compression ratio for each observer. The parameters used for assessment of transfer characteristics of the compression algorithm were input/output response, noise, high-contrast response, and low-contrast-detail response. The computer-generated test image, used for this assessment, mimicked mammographic image characteristics (pixel size, pixel depth, and noise) as well as microcalcification characteristics (size and contrast). The ROC analysis for microcalcification cluster detection indicated a threshold at compression ratio 40:1, as Student's t-test shows statistically significant differences in A(z) values (p<0.05) for compression ratios 70:1 and 100:1. Observers' grading of mammogram quality lowers this threshold at 25:1. Low-contrast-detail detectability in the transfer characteristics study indicate a threshold of 35:1, whereas non-perceptibility of image-quality-parameters degradation lowers this threshold to 30:1. The ROC and transfer characteristics analysis provided comparable thresholds, indicating the potential use of the latter in limiting the target range of compression ratios for subsequent observer studies.

Aged↗

Compression assessment based on medical image quality concepts using computer-generated test images.

Compression algorithms are widely used in medical imaging systems for efficient image storage, transmission, and display. In the acceptance of lossy compression algorithms in the clinical environment, important factors are the assessment of 'visually lossless' compression thresholds, as well as the development of assessment methods requiring fewer data and time than observer performance based studies. In this study a set of quantitative measurements related to medical image quality parameters is proposed for compression assessment. Measurements were carried out using region of interest (ROI) operations on computer-generated test images, with characteristics similar to radiographic images. As a paradigm, the assessment of the lossy Joint Photographic Expert Group (JPEG) algorithm, available in a telematics application for healthcare, is presented. A compression ratio of 15 was found as the visually lossless threshold for the JPEG lossy algorithm, in agreement with previous observer performance studies. Up to this ratio low contrast discrimination is not affected, image noise level is decreased, high contrast line-pair amplitude is decreased by less than 3%, and input/output gray level differences are minor (less than 1%). This type of assessment provides information regarding the type of loss, offering cost and time benefits, in parallel with the advantages of test image adaptation to the requirements of a certain imaging modality and clinical study.

Algorithms↗

Simulating the mammographic appearance of circumscribed lesions.

Optimization performance of digital image post-processing techniques in mammography requires controlled conditions of data sets permitting quantitative representation of image characteristics of pathological findings. Digital test objects, although objective and quantitative, do not mimic mammographic appearance and clinical data sets do not provide adequate sets of values of the various pathological finding characteristics. This can be overcome by digital simulation of pathological findings and superimposition on mammographic images. A simple method for simulation of mammographic appearance of radiopaque and/or radiolucent circumscribed lesions is presented. Circumscribed lesions are simulated using grey-level transformation functions which shift and compress the range of the initial pixel grey-level values in a region of interest (ROI) of a digitized mammographic image, according to grey-level analysis in 200 ROIs of real circumscribed lesions from digitized mammographic images. Simulation addresses lesion image characteristics, such as elliptical shape, orientation, halo sign for radiopaque lesions and capsule for radiolucent lesions, and is implemented in a user-driven PC-based interactive application. The appearance of the lesions is evaluated by six radiologists on a sample of 60 real and 60 simulated radiopaque lesions with the use of receiver operating characteristic (ROC) analysis. The area under the ROC curve, pooling the responses of the observers, was 0.55+/-0.03 indicating no statistically significant difference between real and simulated lesions (p>0.05). The method adequately simulates the mammographic appearance of circumscribed lesions and could be used to generate circumscribed lesion data sets for performance evaluation of image processing techniques, as well as education purposes.

Adipose Tissue↗

A protocol-based evaluation of medical image digitizers.

Medical film digitizers play an important transitory role as digital-to-analogue bridges in radiology. Their use requires performance evaluation to assure medical image quality. A complete quality control protocol is presented, based on a set of test objects adaptable to the specification of various digitizers. The protocol includes parameters such as uniformity, input-output response, noise, geometric distortion, spatial resolution, low contrast discrimination, film slippage and light leakage, as well as associated measurement methods. The applicability of the protocol is demonstrated with two types of medical film digitizers; a charge-coupled device (CCD) digitizer and a laser digitizer. The potential value of the protocol is also discussed.

Analog-Digital Conversion↗

Quantifying image quality at breast periphery vs mammary gland in mammography using wavelet analysis.

Use of high contrast film-screen systems in mammography, in combination with the fact that exposure parameters are selected to ensure good visualization of the mammary gland, results in overexposure of the film area corresponding to the breast periphery, therefore decreasing image quality. The aim of this work was to provide a quantitative evaluation of image quality at the breast periphery compared with the mammary gland. To deal with the difficulties in quantification of image quality introduced by low contrast encountered at the breast periphery, wavelet analysis has been used for derivation of a contrast indicator (CI) and a noise indicator (NI), taking into account local grey level variations. Gradient magnitude coefficients corresponding to region of interest (ROI) grey level values are the basis of CI definition. Mammary gland and breast periphery were sampled by equally spaced ROIs, the quantity of which was determined by a heuristic method. For NI definition, the power values of gradient magnitude coefficients corresponding to the ROI were utilized. Image quality at the breast periphery compared with the mammary gland was evaluated using 150 craniocaudal images from the Digital Database for Screening Mammography. Measurements were carried out using a tool developed in our department. A 50% contrast decrease at the breast periphery was observed, while noise decreased by approximately 2%.

Breast Diseases↗

A digital density equalization technique to improve visualization of breast periphery in mammography.

In mammographic imaging, the film area corresponding to the breast periphery is overexposed, resulting in high optical density and degraded contrast in this region. A digital, model-driven density equalization technique was designed and developed to overcome this overexposure problem, taking into account the non-linear characteristic curve of the film-digitizer system. The method is based on several image processing and analysis techniques, such as thresholding, which is used to segment the pixels of the mammogram belonging to the breast region from the background, and wavelet-based fusion, which is used to equalize the pixels of breast periphery selectively while leaving the remaining breast region unaffected. Initial application of the method resulted in density-equalized mammographic images, characterized by improved contrast at the breast periphery.

Breast Neoplasms↗

A phantom-based evaluation of an exposure equalization technique in mammography.

An anatomical filter based exposure equalization technique in mammography is evaluated quantitatively using a phantom. The evaluation is carried out by a comparative observer performance study, comparing the equalization technique with a conventional one based on visualization of low contrast, 6 mm circular details and high contrast, 0.5 mm and 0.25 mm small size details. These details are situated at the phantom edge, simulating the breast periphery. Visualization of these details is studied with respect to the parameters of tube voltage, optical density, detail location and phantom thickness. Phantom images are interpreted independently by three observers using a four-point grading scale. Use of the Wilcoxon signed ranks test for paired data shows statistically highly significant improvement (p < 0.0001) in the visualization of details for the equalization technique for all values of the parameters studied. The improvement is independent of tube voltage but dependent on optical density, detail location and phantom thickness. Optimal performance is obtained for detail location closer to the outer border of the simulated breast periphery and/or further away from the film, as well as for a greater phantom thickness simulating both thick and dense breast.

Breast Neoplasms↗

Distance learning in mammographic digital image processing.

The potential of interactive multimedia and Internet technologies is investigated with respect to the implementation of a distance learning system in medical imaging. The system is built according to a client-server architecture, based on the Internet infrastructure, composed of server nodes conceptually modelled as World Wide Web (WWW) sites. Sites are implemented by integration and customization of available components. The system evolves around network-delivered interactive multimedia courses and network-based tutoring, which constitute its main learning features. This potential has been demonstrated by means of an implemented system, validated with digital image processing content, specifically image enhancement. Image enhancement methods are theoretically described and applied on mammograms. Emphasis is given in the interactive presentation of the effects of algorithm parameters on images. The system end-user access depends on available bandwidth, so high speed access can be achieved via LAN or local ISDN connections.

Biomedical Engineering↗

Evaluation of an anatomical filter-based exposure equalization technique in mammography.

An anatomical filter-based exposure equalization technique in mammography is clinically evaluated. An observer performance comparative study, between this technique and the conventional one, is carried out on the basis of the visualization of six anatomical features situated at the breast periphery. The effect of parenchymal breast patterns and compressed breast thickness in the visualization of these features is studied. 533 craniocaudal mammograms were interpreted by two radiologists independently, using a five-point rating scale. Use of the Wilcoxon ranking test for unpaired data shows statistically highly significant improvement (p < 0.0001) in the visualization of the nipple, areola, skin and subcutaneous fat in all cases, for the equalization technique. The improvement is dependent on parenchymal breast patterns and compressed breast thickness for peripheral Cooper's ligaments and peripheral surface veins. In the case of total fatty replacement and/or thin breasts neither technique seems to be superior (p > 0.05) with respect to these two features. Clinical results indicate the value of this technique in clinical routine.

Adult↗

PRONET services for distance learning in mammographic image processing.

The potential of telematics services is investigated with respect to learning needs of medical physicists and biomedical engineers. Telematics services are integrated into a system, the PRONET, which evolves around multimedia computer based courses and distance tutoring support. In addition, information database access and special interest group support are offered. System architecture is based on a component integration approach. The services are delivered in three modes: LAN, ISDN and Internet. Mammographic image processing is selected as an example content area.

Biomedical Engineering↗

Use of wavelet analysis for contrast enhancement in mammography.

A wavelet analysis approach to contrast enhancement in mammography is presented. The approach consists of application of non-linear enhancement of multiscale gradient magnitudes utilising edge location information. The performance of wavelet analysis is evaluated by means of a breast phantom. Preliminary results indicate the value of the approach in contrast enhancement and edge preservation for both simulated tumours and microcalcifications.

Breast Neoplasms↗

Radiographic skills learning: procedure simulation using adaptive hypermedia.

The design and development of a simulation tool supporting learning of radiographic skills is reported. This tool has by textual, graphical and iconic resources, organized according to a building-block, adaptive hypermedia approach, which is described and supported by an image base of radiographs. It offers interactive user-controlled simulation of radiographic imaging procedures. The development is based on a commercially available environment (Toolbook 3.0, Asymetrix Corporation). The core of the system is an attributed precedence (priority) graph, which represents a task outline (concept and resources structure), which is dynamically adjusted to selected procedures. The user interface imitates a conventional radiography system, i.e. operating console, tube, table, patient and cassette. System parameters, such as patient positioning, focus-to-patient distance, magnification, field dimensions, tube voltage and mAs are under user control. Their effects on image quality are presented, by means of an image base acquired under controlled exposure conditions. Innovative use of hypermedia, computer based learning and simulation principles and technology in the development of this tool resulted in an enhanced interactive environment providing radiographic parameter control and visualization of parameter effects on image quality.

Computer Simulation↗