PubMed Health⌕ Search

Biomedical subjects

L D Platt

Publications and source records attributed to L D Platt.

At least 19 recordsLinked to original sources

Use of three-dimensional ultrasound imaging in the diagnosis of prenatal-onset skeletal dysplasias.

OBJECTIVE: Recognition of prenatal-onset skeletal dysplasias has improved with advances in ultrasound imaging. Skeletal abnormalities can be recognized by two-dimensional (2D) ultrasound, but generating a precise diagnosis can be challenging. We aimed to determine whether three-dimensional (3D) imaging conferred any advantages over 2D imaging in these cases. METHODS: We studied five women with fetuses of 16-28 gestational weeks referred for abnormal ultrasound skeletal findings. First 2D and then 3D sonography was performed and the results compared. RESULTS: The pregnancies resulted in the following skeletal dysplasias: thanatophoric dysplasia, achondrogenesis II/hypochondrogenesis, achondroplasia, chondrodysplasia punctata (rhizomelic form) and Apert's syndrome. For all five fetuses, the correct diagnosis was made in the prenatal period by analysis of the 2D images. In each case the 3D images confirmed the preliminary diagnosis and for many findings it improved the visualization of the abnormalities. CONCLUSION: The 3D imaging had advantages over the 2D imaging when it came to evaluation of facial dysmorphism, relative proportion of the appendicular skeletal elements and the hands and feet. Most importantly, the patient and referring physician appreciated the 3D images of the abnormal findings more readily which aided in counseling and management of the pregnancy.

Bone Diseases, Developmental↗

Spatio-temporal image correlation (STIC): new technology for evaluation of the fetal heart.

Spatio-temporal image correlation (STIC) is a new approach for clinical assessment of the fetal heart. It offers an easy to use technique to acquire data from the fetal heart and to aid in visualization with both two-dimensional and three-dimensional (3D) cine sequences. The acquisition is performed in two steps: first, images are acquired by a single, automatic volume sweep. Second, the system analyzes the image data according to their spatial and temporal domain and processes an online dynamic 3D image sequence that is displayed in a multiplanar reformatted cross-sectional display and/or a surface rendered display. The examiner can navigate within the heart, re-slice, and produce all of the standard image planes necessary for a comprehensive diagnosis. The advantages of STIC for use in evaluation of the fetal heart are as follows: the technique delivers a temporal resolution which corresponds to a B-mode frame rate of approximately 80 frames/s; it provides the examiner with an unlimited number of images for review; it allows for correlation between image planes that are perpendicular to the main image acquisition plane; it may shorten the evaluation time when complex heart defects are suspected; it enables the reconstruction of a 3D rendered image that contains depth and volume which may provide additional information that is not available from the thin multiplanar image slices (e.g. for pulmonary veins, septal thickness); it lends itself to storage and review of volume data by the examiner or by experts at a remote site; it provides the examiner with the ability to review all images in a looped cine sequence.

Artifacts↗

First-trimester trisomy screening: nuchal translucency measurement training and quality assurance to correct and unify technique.

OBJECTIVE: To describe the process of training for measuring nuchal translucency at five clinical centers in North America and to evaluate methods of quality assurance and feedback. DESIGN: Throughout a period of 18 months, the performance of sonographers in measuring fetal nuchal translucency was monitored using qualitative and quantitative methods of review. After 12 months, different approaches (written and personal feedback) were used to inform sonographers of technical aspects that needed to or could be improved. RESULTS: On initial qualitative review, discrepancies in judgment from different reviewers coincided with suboptimal magnification, failure to visualize the amniotic membrane and/or use of cross-shaped calipers. At subsequent global review, 13 (29%) images of nuchal translucency measurements were considered unacceptable. Quantitative assessment revealed that, during the first part of the study, the means from four sonographers were significantly smaller and the mean from the fifth sonographer was significantly larger than expected on the basis of findings from The Fetal Medicine Foundation (P < 0.0001). Following feedback, sonographers who underestimated nuchal translucency and who received a written report only did not change measurements overall (P = 0.9759). In contrast, those who received additional intervention showed a marked difference (P < 0.0001). CONCLUSIONS: Global qualitative review of images from one sonographer may be preferable to assessment of individual aspects of images. Results from global qualitative review correspond well with findings from quantitative analysis, indicating that the latter can be applied for ongoing audit. Observation of divergent results should prompt extensive personal feedback, rather than a written report, to prevent sonographers from settling in their own, inappropriate technique.

Allied Health Personnel↗

Variation in vaginal breech delivery rates by hospital type.

OBJECTIVE: To relate vaginal breech delivery rates to the following hospital types: public, health maintenance organization, private teaching, or private nonteaching. METHODS: In a retrospective study using administrative discharge data from Los Angeles County, California, we calculated the vaginal breech delivery rates of singleton breech deliveries during calendar years 1988 and 1991. RESULTS: Ten thousand four hundred breech deliveries were identified, 8988 (86.4%) term and 1412 (13.6%) preterm. Twelve percent (1252 of 10,400) were vaginal deliveries (10.1% term and 24.5% preterm). Term vaginal breech deliveries varied by hospital type and were more frequent in public hospitals (28.4%, 95% confidence interval [CI] 26.1%, 30.7%) and less frequent in private nonteaching hospitals (5.4%, 95% CI 4.8%, 5.9%). Term vaginal deliveries were 2.4 to 11.3 times more likely among black women and 1.3 to 6.3 times more likely for Hispanic women across all hospital types, compared with white women in private nonteaching hospitals. There was no difference in the proportion of preterm vaginal breech deliveries by hospital type (mean 24.5%). However, with the exception of public hospitals, the proportion of vaginal breech deliveries for both term and preterm deliveries varied significantly by ethnicity. CONCLUSION: The use of vaginal breech delivery varied by hospital type and patient ethnicity. Within private teaching and nonteaching hospitals, vaginal breech delivery was more likely for black women than for women of other ethnic groups. Further study is needed to understand the hospital policies or organizational factors, as well as the patient-related sociocultural and clinical factors, that contribute to those differences.

Adult↗

Maternity leave: existing policies in obstetrics and gynecology residency programs.

OBJECTIVE: To survey program directors in obstetrics and gynecology regarding maternity leave and to determine how programs are dealing with maternity leave coverage. METHODS: Questionnaires regarding impact and policy on maternity leave were mailed to accredited obstetrics and gynecology residency programs. RESULTS: A total of 188 of 274 (69%) questionnaires were returned completed. Respectively, 80% and 69% of respondents indicated that they have a formal maternity (maximum mean 8.7 weeks) and paternity (mean 5.27 days) leave policy. Approximately 75% of programs require residents to make up time if their leave exceeds 8 weeks during the first 3 years. Eighty-five percent of programs require residents to make up time if their leave exceeds 6 weeks during the fourth year. Ninety-three percent of programs require residents to make up time if their leave exceeds 20 weeks over the 4 years. Seventy-seven percent of respondents have other residents in their program cover for the absent resident. Thirty-seven percent of programs have schedules flexible enough to allow rearrangement so that some rotations go uncovered. Eighty-three percent of programs surveyed stated that maternity leave has a somewhat to very significant impact on the residents' schedules. CONCLUSION: Most residency programs have written maternity/paternity leave policies. A more flexible curriculum may help to accommodate the residents on leave without overburdening the residents who are left to cover.

Canada↗

Variation in elective primary cesarean delivery by patient and hospital factors.

OBJECTIVE: Our purpose was to describe variation in elective primary cesarean rates by nonclinical factors. STUDY DESIGN: With use of California discharge data and American Hospital Association data for 1995, patients were classified into 13 mutually exclusive categories for elective primary cesarean delivery. With use of recursive partitioning algorithms, women in each category were then studied to determine whether nonclinical factors were associated with elective primary cesarean delivery. RESULTS: A total of 463,196 women were delivered at 288 hospitals, and the elective primary cesarean delivery rate was 4.25% (19,664/463,196). Risk for elective primary cesarean delivery varied by clinical condition. The most discriminant risk factors were hospital type (malpresentation, multiple gestation, macrosomia, other hypertension), maternal age (antepartum bleeding, uterine scar, soft tissue disorder, preterm, unspecified), and teaching status (herpes, severe hypertension, unengaged head). CONCLUSION: This article presents methods that use administrative data to isolate and monitor the impact of nonclinical factors on the use of elective primary cesarean.

Adolescent↗

The international study of pregnancy outcome in women with maternal phenylketonuria: report of a 12-year study.

OBJECTIVE: The purpose of this report was to update the results of the Maternal Phenylketonuria Collaborative Study, which was established to assess the efficacy of a phenylalanine-restricted diet in preventing morbidity among the offspring of women with hyperphenylalaninemia. STUDY DESIGN: During a 12-year period 576 women with hyperphenylalaninemia were enrolled in this study. Outcome measures were stratified according to classification of maternal hyperphenylalaninemia and the time at which dietary control of phenylalanine level was achieved. RESULTS: Optimal physical and cognitive fetal outcomes occurred when maternal blood phenylalanine level <600 micromol/L was achieved by 8 to 10 weeks' gestation and maintained throughout pregnancy (trimester average, </=600 micromol/L). CONCLUSIONS: The achievement of blood phenylalanine level control through a phenylalanine-restricted diet significantly diminished the occurrence of congenital abnormalities among offspring of women with hyperphenylalaninemia and improved early intellectual progress of these offspring.

Adult↗

The use of chorionic villus biopsy catheters for saline infusion sonohysterography.

BACKGROUND: Saline infusion sonohysterography is one of the recent refinements of ultrasonography that has the ability to enhance imaging of the uterine cavity in a safe, inexpensive and expedient manner. The technique can be difficult in women with a stenotic cervical os. This report describes a single-pass technique using chorionic villus sampling (CVS) catheters for saline infusion sonohysterography. METHOD: Saline infusion sonohysterography requires the transcervical passage of a catheter, through which saline is infused. The subsequent distension of the uterine cavity enhances the ability to detect intrauterine pathology with ultrasonography. In women with cervical stenosis, a catheter can be used in place of the more conventional two-pass technique, which requires the use of a uterine sound or probe followed by a conventional catheter. EXPERIENCE: We have used CVS catheters in women with cervical stenosis on 12 occasions. All have been successful and without significant discomfort to the patient. CONCLUSION: The use of CVS catheters for saline infusion sonohysterography in women with cervical stenosis can alleviate the need to remove the cervical probe prior to introduction of the catheter.

Catheterization↗

Femur length and trisomy 21: impact of gestational age on screening efficiency.

OBJECTIVE: This study assesses two methods used to define relatively short femur in screening for trisomy 21 and examines changes in performance of screening with gestational age. DESIGN: Retrospective analysis of data on menstrual age, femur length (FL) and biparietal diameter (BPD) in 49 trisomy 21 pregnancies and 6069 normal controls. Reference ranges were derived for BPD/FL versus menstrual age and for FL versus BPD. Two methods of defining short femur (BPD/FL and observed-to-expected FL ratio) were examined for false-positive rates and detection rates for trisomy 21 at different gestational ages. RESULTS: In the control group the BPD/FL ratio and its standard deviation decreased with menstrual age. Trisomy 21 was associated with a significantly higher BPD/FL ratio (P < 0.001) and the deviation increased significantly with menstrual age (P < 0.05). Eleven percent of 28 fetuses examined at 15-17 weeks had a BPD/FL above the 95th centile compared with 24% of 21 fetuses examined at 18-20 weeks (P = 0.40). The median observed-to-expected FL ratio in the control group was 1.0 throughout the gestational age range but the standard deviation decreased significantly with menstrual age (P < 0.01). Trisomy 21 was associated with a significantly reduced observed-to-expected FL ratio (P < 0.001) and the deviation increased significantly with menstrual age (P < 0.05). A fixed cut-off of 0.91 for observed-to-expected FL ratio provided a false-positive rate of 12% at 15-17 weeks compared with 6% at 18-20 weeks of gestation (P < 0.001) with detection rates of 29 and 38%, respectively (P = 0.73). CONCLUSION: Irrespective of the definition used to define the condition, relatively short femur is a poor marker for trisomy 21 particularly when the assessment takes place before 18 weeks of gestation.

Adult↗

Fetal echogenic bowel: parameters to be considered in differential diagnosis.

OBJECTIVES: To evaluate the extent that associated findings aid in the differential diagnosis and/or prognosis of fetal echogenic bowel. METHODS: Medical history, obstetric records and outcome details were examined for 131 consecutive pregnancies with fetal hyperechogenic bowel. RESULTS: In 62 (47%) cases, there were no visible anomalies other than hyperechogenic bowel and no evidence of growth restriction. This group included four (7%) pregnancies with Down syndrome, 15 (24%) with infection or a recent episode of influenza and eight (13%) with blood staining of amniotic fluid. In the remaining 69 (53%) cases, hyperechogenic bowel was accompanied by hydrops or nuchal edema (n = 16, 12.2%), growth restriction (n = 9, 6.9%), other markers for chromosome anomalies (n = 33, 25.2%) or multiple structural anomalies (n = 11, 8.4%). In this group, the prevalence of Down syndrome was 12%, infection or influenza was reported in 14 (20%) cases and there was blood staining of amniotic fluid in seven (10%). Cystic fibrosis screening was performed in 65 (50%) pregnancies; the results were negative in all cases and clinical assessment did not indicate cystic fibrosis in any of the 91 infants who were born alive. Maternal serum screening was performed in 41 (31%) pregnancies. High alpha-fetoprotein levels were associated with multiple abnormalities or severe growth restriction. CONCLUSIONS: In many pregnancies with fetal hyperechogenic bowel, there are multiple factors that may explain these findings. Thus identification of one potential underlying cause should not preclude further testing. Once chromosome defects, cystic fibrosis, structural abnormalities, infection and growth restriction have been excluded, parents can be counseled that the prognosis is good, irrespective of the presence or absence of blood stained amniotic fluid.

Adolescent↗

Peritoneal serous papillary carcinoma, a phenotypic variant of familial ovarian cancer: implications for ovarian cancer screening.

OBJECTIVE: Our purpose was to report the cancers arising during a familial ovarian cancer screening program and investigate the tumor's clonality and association with BRCA1 and BRCA2 mutations. STUDY DESIGN: Program participants with a diagnosis of ovarian cancer or peritoneal serous papillary carcinoma were identified and their demographic characteristics, ultrasonographic findings, CA 125 results, operative reports, and pathology slides reviewed. Immunohistochemical analysis of p53, bcl-2, HER-2/neu, and nm23 H1 expression was performed on tumor tissues from multiple metastatic sites, and germline BRCA1 and BRCA2 mutations were identified. RESULTS: Three stage I ovarian cancers and 7 cases of peritoneal serous papillary carcinoma were diagnosed from among 1261 program participants. Ultrasonographic abnormalities triggered surgical exploration in all 3 cases of stage I disease. Elevated levels of CA 125 were the harbinger in 2 of 7 cases of peritoneal serous papillary carcinoma, abnormal ultrasonographic findings prompted diagnosis in 2 of 7 cases, and 3 of 7 women had abdominal symptoms 5, 6, and 16 months after screening. Results of immunohistochemical studies suggested multifocal disease in 5 of 7 patients with peritoneal serous papillary carcinoma. At least 3 of the patients with peritoneal serous papillary carcinoma carry BRCA1 185delAG mutations. CONCLUSION: Multifocal peritoneal serous papillary carcinoma may be a phenotypic variant of familial ovarian cancer, and screening strategies for these women cannot rely on ultrasonography and CA 125 testing to detect early disease.

Adult↗