Architecture and design of a computerised stereogram generator for vision test.

A new microcomputer-based stereogram generator was designed and implemented to generate various visual stimuli that are used for testing the binocular vision system. The system is capable of generating static and dynamic stereoscopic stereograms that can be varied in size, shape, speed and disparity. It can also be used to generate a luminous stimulus on a dark background which, except for the depth parameters, can be varied in a similar way to the stereoscopic stimulus. A 16/32-bit microprocessor has been employed for the overall control of the stereogram parameters, which provides flexibility, versatility, compactness and speed at reduced cost. We have applied this system to the measurement of eye movement and computer vision.

Diagnosis, Computer-Assisted↗

Phase channels and the square-wave illusion.

We have utilized a phase-sensitive effect, the square-wave illusion, to investigate the presence and tuning of phase-sensitive mechanisms. Subjects viewed a 1 c/deg triangular-wave grating and reported the presence or absence of the illusion, before and after adaptation to square-wave gratings of various spatial frequencies. Illusion strength declined with adaptation and was a function of spatial frequency. This function may reflect the spatial frequency tuning of a 'phase channel'. We have also measured by adaptation a contrast sensitivity function, maximally sensitive to a frequency of 1 c/deg. When normalized to the same maximal depression from baseline sensitivity, the phase channel and spatial-frequency channel shared the same low frequency tuning, but the phase channel was broader, with extended sensitivity to higher frequencies. These results can be understood if the phase channel is constructed from combinations of phase sensitive spatial-frequency channels.

Adaptation, Ocular↗

The predictability of infant visual-evoked response testing on future visual acuity.

We reviewed the records of 27 infants with abnormal eye examinations and visual-evoked response (VER) testing (mean age, 10.5 months) who subsequently underwent a long-term follow-up ophthalmology examination (mean duration, 41 months). The infants were initially diagnosed with various ocular disorders including cortical blindness (eight), optic nerve hypoplasia (six), congenital cataract (two), and retinopathy of prematurity (one). Standard optotype visual-acuity determinations were available in the follow-up records of 11 children (21 eyes), and fixation behavior was obtained in the remaining 16 children (32 eyes). Results revealed that pattern-reversal VER P1 latency was predictive (87%) of whether visual acuity was equal to (or better than) or worse than 20/100 and whether a patient would have good fixation behavior (fix and follow, FF) or poor fixation (no FF) (86%) (P less than .001). Although flash VER P1 latency was also predictive of later visual acuity or good fixation (73%), it was not statistically significant. Pattern VER P1 amplitude and flash VER P1 amplitude were not predictive of later visual function. The predictive power of pattern VER P1 latency for later visual function probably relates to its reflection of macular function and low variability. An analysis of the variability of each of the four VER factors in normal infants (n = 50) indicated that pattern VER P1 latency was the least variable, and consequently most sensitive, VER factor for detecting and quantifying pathology. Overall, the results of this retrospective study suggest that pattern VER P1 latency may have important predictive power for later visual function in infants with an initially abnormal ophthalmologic examination.

Evoked Potentials, Visual↗

Serum fatty acid proportions in retinitis pigmentosa may be affected by a number of factors.

Variations in serum fatty acid (FA) proportions of 67 Retinitis pigmentosa patients suggested a consideration of other factors which might affect these values. Serum FA, particularly arachidonic acid, may be altered during immunoregulatory substance formation in addition to genetic and dietary controls. Parallel immune system studies of these patients showed FA patterns consistent with increased prostaglandin-mediated (PG) lymphocyte suppression in 27% and possible block of PG immunoregulation in another 37%. While differences found between total serum FA of RP patients and age-matched normals included lower 18:2 omega 6 and higher 22:6 omega 3, the dominant and recessive RP patients showed similar proportion. However, lower than normal 22:6 omega 3 was found in 7 Usher RP.

Adolescent↗

Immune alterations associated with T lymphocyte activation and regulation in retinitis pigmentosa patients.

Altered immunoregulation, suggested previously in the heredo-familial retinal degeneration, retinitis pigmentosa (RP), led us to examine cell-mediated immune responses in 58 RP patients who expressed either recessive or dominant inheritance. Increased absolute numbers of activated T-cells, quantitated by flow cytometry using the Ta1 epitope, were found in the peripheral blood of 60% of these RP patients. The unusual finding was equally distributed between dominant (16 of 25) and recessive (19 of 33) types of RP, suggesting an immune process present in both patterns of heredity. Additional altered lymphocyte immunoregulation was suggested in all RP by lymphocyte responses to stimulants modified by indomethacin or histamine in vitro. Although no clear association could be found between Tal expression and demographic factors including age, sex, years with RP symptoms, or percentage of life with RP disease, the significantly altered immunoregulatory responses in RP may be related to the pathogenesis of RP.

Adolescent↗

The contrast sensitivity function and childhood amblyopia.

We measured contrast sensitivity function and visual acuity in both eyes of strabismic and anisometropic amblyopic patients. There was a linear relationship between contrast sensitivity function and visual acuity in the amblyopic eye. As visual acuity decreased, the contrast sensitivity function decreased along the contrast sensitivity axis, and peak sensitivity shifted to lower spatial frequencies. After patching therapy, when visual acuity reached 20/20 in each eye, suggesting that the amblyopia was cured, there continued to be statistically significant difference in the contrast sensitivity functions between the eyes. The contrast sensitivity function from the previously amblyopic eye was depressed compared to the nonamblyopic eye. A comparison between patients with strabismic and anisometropic amblyopia showed that, when matched for visual acuity, the contrast sensitivity functions were similar for both the nonamblyopic and amblyopic eyes. However, a large difference was found between the amblyopic and nonamblyopic eyes of each group.

Amblyopia↗

Pattern electroretinogram: use of noncorneal skin electrodes.

Pattern electroretinograms (ERGs) were recorded in three adults by a noncorneal electrode technique: silver-silver chloride skin electrodes attached to the inferior orbit of the left eye while the subject monocularly viewed a high contrast checker-board that reversed in contrast at a rate of 10 Hz. Recordings revealed pattern ERGs with an average amplitude of 1.5 microV. In addition, pattern ERGs were recorded as a function of spatial frequency and contrast of a square-wave grating. The results showed that an increase in spatial frequency or contrast yielded an increase in the amplitude of the pattern ERG. The results demonstrate that the pattern ERG can be recorded with a noncorneal electrode technique and that the noncorneal electrode technique is sensitive to changes in retinal function. Finally, it is demonstrated that the pattern ERG can transfer between the eyes such that the pattern ERG from a viewing eye can be recorded from an electrode placed below an occluded eye.

Adult↗

The square-wave illusion and phase anisotropy of the human visual system.

A triangular-wave grating is perceived to fluctuate over time: at one moment it may appear veridical (ie triangular), at another it may more closely resemble a square-wave grating with rounded edges. In addition, the square-wave illusion itself is bistable, in that it sometimes appears to shift in phase by 180 deg. Experiments in which the phase and amplitude of the first three frequency components of the triangular-wave grating were independently varied showed that the square-wave illusion results from the relative phase of the frequency components. Adaptation to two frequency components in square-wave (sine) phase was found to reduce the illusion strength, and adaptation to triangular-wave (cosine) phase was found to increase the illusion strength. In addition, the square-wave adaptation effect spreads to nonadapted retinal areas. It is concluded that the square-wave illusion reflects a phase anisotropy in the human visual system that favors square-wave phase over other phase relations.

Eye Movements↗

Role of threshold in afterimage visibility.

The negative afterimage from grating can be considered equivalent to a renal grating, the contrast of which decreases over time. The interval between the onset of the afterimage and the time at which the effective contrast of the afterimage falls below threshold defines afterimage duration. In a series of experiments with several predictions based on this formulation were confirmed. Square-wave gratings yielded longer afterimage durations than sinusoidal gratings, a difference that is attributable to the difference in threshold between these two types of grating. Also, grating adaptation before afterimage induction was found to abbreviate afterimage duration because of threshold elevation. Finally, it was found that, even after fading to invisibility, an afterimage could interact with a real grafting to influence threshold performance on a forced-choice detection task.

Afterimage↗

Pursuit eye movements and the depth-movement phenomenon in dynamic visual noise.

The ability to generate voluntary pursuit eye movements in the absence of retinal-contour motion cues was assessed on the basis of observers' perceptions of depth and motion when they viewed dynamic visual noise with a filter over one eye. The results indicated that the depth-movement phenomenon yielded robust pursuit with the velocity an inverse function of filter density. These data suggest that retinal-contour motion cues are not necessary and that perceived motion is sufficient to drive pursuit.

Cues↗

Clinical assessment of visual function in the young child: a prospective study of binocular vision.

Binocular vision was evaluated in 12 children with infantile esotropia before and after corrective surgery. Stereopsis was measured by the eye movement/global stereopsis method. Also in a subgroup of four infants, binocular and monocular pattern VERs were recorded to evaluate binocular summation. Results revealed 50% of the infantile esotropia children who had corrective surgery before one year of life developed gross stereopsis two weeks following surgery. In addition, of four infants who showed no evidence of stereopsis, 50% showed some degree of binocular summation following surgery. The importance of prospective studies of binocular vision in infantile esotropia is discussed within the context of new tests that can be used to objectively assess binocularity in the preverbal child.

Esotropia↗

Contrast sensitivity functions in normal children with the Vistech method.

The Vistech Contrast Sensitivity Function tester (VCTS 6500-1) for distance was evaluated to determine the minimum age of children who could complete the test and to determine changes in the CSF as a function of age. A total of 72 normal children between the ages of 24 and 84 months were tested twice with each eye. The results revealed that no child below 36 months of age could complete the test and by 48 months of age 50% could complete the test. By 60 months all children could complete the test. It was also found that age increased the CSF increased equally at all spatial frequencies. A comparison between the eyes of the CSFs revealed a highly statistically significant correlation of 0.78, which showed that the eyes were very similar. Test-retest correlations (0.78) also were highly statistically significant, which demonstrated that the test was very reliable. The results are discussed within the context of screening young children for visual disorders and the evaluation of patching therapy for amblyopia.

Child Development↗