PubMed HealthSearch

Biomedical subjects

L E Myers

Publications and source records attributed to L E Myers.

5 recordsLinked to original sources

Standardization of sensitive human immunodeficiency virus coculture procedures and establishment of a multicenter quality assurance program for the AIDS Clinical Trials Group. The NIH/NIAID/DAIDS/ACTG Virology Laboratories.

An independent quality assurance program has been established by the Division of AIDS, National Institute of Allergy and Infectious Diseases, for monitoring virologic assays performed by nearly 40 laboratories participating in multicenter clinical trials in the United States. Since virologic endpoints are important in evaluating the timing and efficacy of therapeutic interventions, it is imperative that virologic measurements be accurate and uniform. When the quality assurance program was initially created, fewer than 40% of the laboratories could consistently recover human immunodeficiency virus (HIV) from peripheral blood mononuclear cells (PBMCs) of HIV-infected patients. By comparing coculture procedures in the more competent laboratories with those in laboratories who were struggling to isolate virus, optimal conditions were established and nonessential reagents and practices were eliminated. Changes were rapidly introduced into a laboratory when experience dictated that such modifications would result in a favorable outcome. Isolation of HIV was enhanced by optimizing the numbers and ratios of patient and donor cells used in cultures, by standardizing PBMC separation procedures, by using fresh rather than frozen donor PBMCs, by processing whole blood within 24 h, and by using natural delectinated interleukin 2 instead of recombinant interleukin 2 products in existence at that time. Delays of more than 8 h in the addition of phytohemagglutinin-stimulated donor cells to freshly separated patient PBMCs reduced recovery. Phytohemagglutinin in cocultures and the addition of Polybrene and anti-human alpha interferon to media were not important in HIV isolation. The introduction of a consensus protocol based on this information brought most laboratories quickly into compliance. In addition, monthly monitoring has successfully maintained proficiency among the laboratories, a process that is critical for the scientific integrity of collaborative multicenter trials. Problems which might not be appreciated for months are now being resolved early, before data can be compromised unknowingly. This consensus protocol is recommended for any laboratory attempting to isolate HIV for the purpose of standardizing recovery and for accessing virologic endpoints in clinical trials.

Culture Media

Assessing the use of known mutagens to calibrate the Salmonella typhimurium mutagenicity assay: I. Without exogenous activation.

There has been an increasing need in genetic toxicology to progress from strictly qualitative tests to more quantitative tests. This, in turn, has increased the need to develop better quality assurance and comparative bioassay methods. In this paper, two laboratories tested 10 Salmonella mutagens in order to determine the usefulness of selected chemicals as potential reference materials to calibrate the Salmonella assay. If variance within a bioassay is sufficiently low and the rankings of the compounds are of acceptable consistency, the chemicals later could be evaluated for use as standard control compounds, as audit materials, and as standard reference materials for comparative bioassay efforts. The results demonstrated that the chosen chemicals (with the possible exception of dimethylcarbamylchloride) provide such consistent results in the Salmonella mutagenicity bioassay that they can be used for semi-quantitative calibration and as possible bioassay controls, special audit chemicals, and potentially as reference standards in comparative bioassay efforts. Reference standards, whether used as audit materials or in comparative bioassays, must be used concurrently with the test substances of interest; used without bias; used in a standardized, highly controlled bioassay; and be tested across an appropriate dose range. The study also shows that when these compounds are used as reference standards much care must be given to the number and spacing of doses if highly reproducible slope values are to be generated. We recommend use of a pilot test to establish a dose range for definitive tests and the placement of doses for the definitive tests within the first half of the linear dose-response curve. For appropriate comparisons, one should replicate the tests using the defined dose range and analyze the results in a non-biased statistical manner.

Calibration

Assessing the use of known mutagens to calibrate the Salmonella typhimurium mutagenicity assay: II. With exogenous activation.

In order to determine the usefulness of selected chemicals as potential reference materials for calibrating the Salmonella assay, two laboratories tested a series of Salmonella mutagens that require exogenous activation. When the variance for individual substances within a bioassay is sufficiently low and the rankings of those substances are of acceptable consistency, they can later be evaluated for use as standard control compounds, as audit materials, and as standard reference materials for comparative bioassay efforts. The purpose of this project, therefore, was to evaluate the variability in the mutagenic response of potential reference chemicals that require exogenous metabolic activation in the standard plate-incorporation Salmonella mutagenicity assay, and to develop ranking criteria for mutagenic activity based on these data. Ten indirect-acting mutagens were tested in two laboratories using Salmonella typhimurium TA100 and an Aroclor-induced rat liver S9. Each laboratory conducted four definitive testing rounds. A different batch of S9 was utilized for every two rounds. Of the 10 chemicals tested only 2-anthramine had a mean slope value greater than 1000 revertants/micrograms. Three chemicals had slope values between 1000 and 100; and five chemicals had slope values between 100 and 10. The remaining compound, 9,10-dimethyl-1,2-benz[a]anthracene, could not be placed into a single category because it had slope values on either side of 100 revertants per mg. Coefficients of variance were low (i.e., below 25% in most cases). The low variability achieved in this study may be accounted for by two parameters of the study. First, based on Claxton et al. (1991a) and the S9 optimization for three compounds, the amount of S9 was calibrated to a set amount of protein per plate (1.1 mg/plate). Secondly, the 10 test doses were placed in the initial, linear, nontoxic portion of the dose-response curves. The use of ten closely spaced, nontoxic doses allowed for a more accurate estimate of the slope.

Animals