PubMed Health⌕ Search

Biomedical subjects

L F Satler

Publications and source records attributed to L F Satler.

At least 109 records · Page 6Linked to original sources

Impact of stents on clinical outcomes in percutaneous left main coronary artery revascularization.

Despite effective treatment of left main coronary artery (LMCA) disease by coronary bypass, there is still need for treatment of the LMCA due to progression of disease or bypass graft failure. We compared the in-hospital and follow-up (1-year) outcomes of patients with LMCA stenosis treated with stents (n = 88), with a matched group of patients undergoing LMCA non-stent procedures (n = 36). Ninety-seven percent of patients in each group underwent previous coronary bypass. Procedural success (angiographic success without major in-hospital complications) tended to be higher in stent patients than in their non-stent counterparts (98% vs 92%, p = 0.12), and overall procedural complications were higher for the non-stent group (5.4% vs 0%, p = 0.03). The incidence of non-Q-wave myocardial infarction was higher in patients with the LMCA treated with stents than in non-stent patients (13% vs 2.7%, p = 0.09). There was no difference in death or Q-wave myocardial infarction between the 2 groups during follow-up. Overall target lesion revascularization at 1 year was 15% after LMCA stenting, and 18% in non-stent patients (p = 0.71). Also, any cardiac event-free survival (including death, Q-wave myocardial infarction, coronary bypass, or angioplasty) was similar for both groups (78% for stents vs 76% for non-stents, p = 0.85). We conclude that in patients undergoing LMCA interventions, stents reduce major hospital complications, but may not significantly reduce repeat revascularization or major cardiac events at 1 year compared with non-stent LMCA procedures.

Aged↗

Paradoxic decreases in atherosclerotic plaque mass in insulin-treated diabetic patients.

This study assessed the impact of diabetes mellitus on atherosclerotic lesion formation. Seventy insulin-treated diabetics, 150 non-insulin-treated diabetics, and 607 nondiabetics with chronic anginal syndromes and de novo native coronary stenoses were studied using (1) angiography, and (2) intravascular ultrasound (reference and lesion arterial, lumen, and plaque areas; area stenosis [reference-lesion/reference lumen area]; remodeling index [reference-lesion lumen area/lesion-reference plaque area]; and slope of the regression line relating lumen area to plaque burden [plaque/arterial area]). Despite being diabetic for longer and having similar lumen compromise, insulin-treated patients had (1) less reference plaque (8.3 +/- 3.4 vs 10.5 +/- 4.5 mm2, p = 0.0015), (2) less stenosis plaque (13.0 +/- 4.9 vs 16.9 mm2, p <0.0001), (3) smaller reference arterial areas (17.1 +/- 5.4 vs 19.7 +/- 6.2 mm2, p = 0.0063), and (4) smaller stenosis arterial areas (15.3 +/- 4.9 vs 19.5 +/- 6.5 mm2, p <0.0001) than non-insulin-treated diabetics. With use of multivariate linear regression analysis, insulin use was an independent (and negative) predictor of reference plaque and arterial areas (p = 0.0308 and p = 0.0179) and stenosis plaque and arterial areas (p = 0.0117 and p = 0.0066). This was also true when normalized for body surface area. The remodeling index showed that insulin treatment resulted in an exaggerated impact of plaque accumulation on lumen compromise. This was confirmed by the slope of the regression line relating lumen area to plaque burden. Patients with a longer duration of diabetes who were treated with insulin for > or = 1 year had (paradoxically) less reference segment and stenosis plaque accumulation. Possible explanations include impaired adaptive remodeling and/or arterial (and plaque) shrinkage.

Aged↗

Procedural results and late clinical outcomes after placement of three or more stents in single coronary lesions.

BACKGROUND: Previous reports have suggested higher procedural and long-term complications among patients treated with multiple stents for diffuse lesions and/or long dissections. METHODS AND RESULTS: To evaluate procedural success, major complications, and clinical outcomes (> or = 1 year) in a consecutive series of patients treated with multiple (> or = 3) contiguous stents in single lesions, we evaluated in-hospital and long-term (1-year) clinical outcomes in 117 consecutive patients treated with > or = 3 coronary stents compared with a concurrent series of patients treated with 1 or 2 stents (n=1673) between January 1, 1994, and December 31, 1995. Multiple stents were implanted more often in larger vessels, in the right coronary artery or saphenous vein grafts, and for unfavorable lesion characteristics, including long (>20 mm), calcified, ulcerated, thrombotic, and/or flow-obstructing lesions. Overall procedural success was obtained in 97.4% of patients and was similar whether 1 or 2 versus > or = 3 stents were used. Non-Q-wave MI (CK-MB > or = 5 times normal) was more frequent after > or = 3 stents (22.8% versus 13.4%, P=.005). Target lesion revascularization (TLR) was 14.6% for 1 or 2 stents and 13.3% for > or = 3 stents (P=.70). There was no difference in death (2.2% versus 0.9%, P=.34) or Q-wave MI (1.4% versus 0.9%, P=.64) between the two groups (1 or 2 stents versus > or = 3 stents, respectively), and overall cardiac event-free survival was similar during follow-up (P=.70). CONCLUSIONS: Patients treated with multiple (> or = 3) contiguous stents compared with 1 or 2 stents have (1) similar in-hospital procedural success and major complications despite having more unfavorable lesion characteristics, (2) a higher rate of procedural non-Q-wave MI, and (3) similar TLR and overall major cardiac event rates during 1 year of follow-up.

Aged↗

In-stent restenosis: the Washington Hospital Center experience.

In-stent restenosis has become a significant clinical problem. In 1997 alone, it is estimated that up to 100,000 patients world-wide with in-stent restenosis were treated. Serial intravascular ultrasound (IVUS) analysis has shown that tubular-slotted stents almost never chronically recoil and that neointimal hyperplasia is responsible for in-stent restenosis. With the rapid recent explosion in stent use, information about in-stent restenosis has lagged behind, especially on the impact of new stent designs. For example, the true prevalence of in-stent restenosis (1) varies with the lesion and patient subset, being much higher in the "real world" than in the selected patients typically enrolled in many studies; and (2) depends on its definition (i.e., clinical vs angiographic, intralesion vs in-stent). "Conventional" catheter-based treatments have included percutaneous transluminal coronary angioplasty (PTCA), rotational atherectomy, excimer laser coronary angioplasty, directional coronary atherectomy, and additional stent implantation. Rates of recurrence with these approaches are not known and vary considerably among series; however, certain lesions seem likely to recur regardless of the treatment modality. Recently, brachytherapy has emerged as the most promising way to treat in-stent restenosis.

Angioplasty, Balloon, Coronary↗

Comparative early and nine-month results of rotational atherectomy, stents, and the combination of both for calcified lesions in large coronary arteries.

The aim of this study was to determine the preferred treatment modality for calcified lesions in large (> or = 3 mm) coronary arteries, resulting in the largest lumen dimensions and the most favorable late clinical responses. Three hundred six lesions in 306 patients (223 men, mean age 66 +/- 11 years) were treated with either rotational atherectomy plus adjunct balloon angioplasty (n = 147), Palmaz-Schatz stents (n = 103), or a combination of rotational atherectomy plus adjunct Palmaz-Schatz stents (n = 56). The procedural success rate was 98.0% to 98.6% for each treatment modality. Minimal lumen diameter (MLD) before therapy was similar for all therapies. Final MLD after combination of rotational atherectomy plus Palmaz-Schatz stents was larger than after stent therapy or rotational atherectomy plus balloon angioplasty (3.21 +/- 0.49 mm, 2.88 +/- 0.51 mm, and 2.29 +/- 0.55 mm, respectively, p <0.0001). Correspondingly, final percent diameter stenosis was lowest after the combination of rotational atherectomy plus stent therapy, and significantly higher for stents or rotational atherectomy plus balloon angioplasty (4.2 +/- 15.3%, 14.1 +/- 13.3%, and 26.7% +/- 16.9%, respectively, p <0.0001). Event-free survival at 9 months was higher for patients treated with the combination of rotational atherectomy plus stents than either stent therapy or rotational atherectomy alone (85%, 77%, and 67%, respectively, log-rank p = 0.0633). The only significant independent predictor of an event during the 9-month follow-up period was the MLD after intervention (odds ratio 0.495, 95% confidence interval 0.308 to 0.796, p = 0.0037). We conclude that preatheroablation using rotational atherectomy, followed by adjunct stent placement for calcified lesions in large arteries, is associated with infrequent complications, the largest acute angiographic results, and the most favorable late clinical event rates.

Aged↗

Interrelation of coronary angiographic reference lumen size and intravascular ultrasound target lesion calcium.

Intravascular ultrasound (IVUS) detects target lesion calcium twice as often as does coronary angiography. Target lesions in smaller vessels are thought to be more calcified than target lesions in large vessels. This study determined whether the presence and magnitude of target lesion calcium is related to angiographic reference lumen size. Preintervention IVUS imaging and coronary angiography were performed to study 1,454 non-aortoostial native vessel lesions in 1,342 patients. Target lesions and reference segments were evaluated according to previously published methods and are presented as mean +/- 1 SD. By angiography, 37% of lesions contained calcium, and 68% of calcium-containing lesions were classified as moderately calcified, and 32% as severely calcified. There was no relation between angiographic reference lumen size and angiographic calcium detection (p = 0.7066) or classification (none/mild vs moderate vs severe, p = 0.8135). By IVUS, 73% of lesions contained calcium. There was a consistent relation between decreasing angiographic reference lumen size and increasing IVUS lesion-associated calcium: the presence of any calcium (p = 0.0122), arc of calcium (p = 0.002), percent of lesions with an arc of calcium > 180 degrees (p = 0.0018), length of calcium (p < 0.0001), presence of any superficial calcium (p < 0.0001), arc of superficial calcium (p < 0.0001), percent of lesions with an arc of superficial calcium > 180 degrees (p = 0.0021), and length of superficial calcium (p < 0.0001). This was especially true for arteries with an angiographic reference lumen dimension < 2.00 mm. There is a distinct relation between decreasing angiographic reference lumen size and increasing lesion calcium, most striking in vessels < 2.00 mm. This increased target lesion calcium in small vessels is not seen angiographically.

Aged↗

Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents.

OBJECTIVES: This study sought to evaluate the clinical, procedural, preinterventional and postinterventional quantitative coronary angiographic (QCA) and intravascular ultrasound (IVUS) predictors of restenosis after Palmaz-Schatz stent placement. BACKGROUND: Although Palmaz-Schatz stent placement reduces restenosis compared with balloon angioplasty, in-stent restenosis remains a major clinical problem. METHODS: QCA and IVUS studies were performed before and after intervention (after stent placement and high pressure adjunct balloon angioplasty) in 382 lesions in 291 patients treated with 476 Palmaz-Schatz stents for whom follow-up QCA data were available 5.5 +/- 4.8 months (mean +/- SD) later. Univariate and multivariate predictors of QCA restenosis (> or = 50% diameter stenosis at follow-up, follow-up percent diameter stenosis [DS] and follow-up minimal lumen diameter [MLD]) were determined. RESULTS: Three variables were the most consistent predictors of the follow-up angiographic findings: ostial lesion location, IVUS preinterventional lesion site plaque burden (plaque/total arterial area) and IVUS assessment of final lumen dimensions (whether final lumen area or final MLD). All three variables predicted both the primary (binary restenosis) and secondary (follow-up MLD and follow-up DS) end points. In addition, a number of variables predicted one or more but not all the end points: 1) restenosis (IVUS preinterventional lumen and arterial area); 2) follow-up DS (QCA lesion length); and 3) follow-up MLD (QCA lesion length and preinterventional MLD and DS and IVUS preinterventional lumen and arterial area). CONCLUSIONS: Ostial lesion location and IVUS preinterventional plaque burden and postinterventional lumen dimensions were the most consistent predictors of angiographic in-stent restenosis.

Adult↗

Remodeling after directional coronary atherectomy (with and without adjunct percutaneous transluminal coronary angioplasty): a serial angiographic and intravascular ultrasound analysis from the Optimal Atherectomy Restenosis Study.

OBJECTIVES: The intravascular ultrasound (IVUS) substudy of OARS (Optimal Atherectomy Restenosis Study) was designed to assess the mechanisms of restenosis after directional coronary atherectomy (DCA). BACKGROUND: Recent serial IVUS studies have indicated that late lumen loss after interventional procedures was determined primarily by the direction and magnitude of arterial remodeling, not by cellular proliferation. METHODS: Complete quantitative coronary angiography (QCA) and IVUS were obtained in 104 patients before and after intervention and during follow-up. All studies were performed after administration of 200 microg of intracoronary nitroglycerin. Angiographic measurements included minimum lumen diameter (MLD), interpolated reference diameter and diameter stenosis (DS). Intravascular ultrasound measurements included lesion and reference external elastic membrane (EEM), lumen and plaque+media cross-sectional area (CSA). The axial location of the lesion site was at the smallest follow-up lumen CSA; the reference segment was the most normal-looking cross section within 10 mm proximal to the lesion but distal to any major side branch. Results are reported as mean +/- one standard deviation. RESULTS: The QCA reference decreased from 3.51 +/- 0.46 mm to 3.22 +/- 0.44 mm; the MLD decreased from 3.22 +/- 0.47 mm to 2.03 +/- 0.72 mm; and the DS increased from 8 +/- 10% to 38 +/- 20%. On IVUS, the decrease in lumen CSA (from 8.8 +/- 2.5 mm2 to 5.5 +/- 4.0 mm2) was associated with a significant decrease in EEM (from 19.7 +/- 5.6 mm2 to 16.9 +/- 6.2 mm2); there was no significant increase in P+M (from 10.9 +/- 4.2 mm2 to 11.3 +/- 3.9 mm2). A change in lumen correlated with a change in EEM (r = 0.790, p < 0.0001), not with a change in P+M (r = 0.133, p = 0.2258). A decrease in reference EEM (from 19.1 +/- 7.7 mm2 to 17.6 +/- 8.0 mm2) also correlated with a decrease in lesion EEM (r = 0.665, p < 0.0001). Results in restenotic lesions were similar. CONCLUSION: Restenosis after optimal DCA is caused primarily by a decrease in EEM CSA that extends into contiguous reference segments.

Anatomy, Cross-Sectional↗

The influence of diabetes mellitus on acute and late clinical outcomes following coronary stent implantation.

OBJECTIVES: We compared the clinical outcomes following coronary stent implantation in insulin-treated diabetes mellitus (IDDM), non-IDDM patients, and nondiabetic patients. BACKGROUND: Diabetic patients have increased restenosis and late morbidity following balloon angioplasty. The impact of diabetes mellitus (DM), especially IDDM, on in-stent restenosis is not known. METHODS: We studied 954 consecutive patients with native coronary artery lesions treated with elective Palmaz-Schatz stents implantation using conventional coronary angiographic and intravascular ultrasound methodology. Procedural success, major in-hospital complications, and 1-year clinical outcome were compared according to the diabetic status. RESULTS. In-hospital mortality was 2% in IDDM, significantly higher (p <0.02) compared with non-IDDM (0%) and nondiabetics (0.3%). Stent thrombosis did not differ among groups (0.9% in IDDM vs. 0% in non-IDDM and 0% in nondiabetics, p >0.1). During follow-up, target lesion revascularization (TLR) was 28% in IDDM, significantly higher (p <0.05) compared with non-IDDM (17.6%) and nondiabetics (16.3%). Late cardiac event-free survival (including death, myocardial infarction [MI], and any coronary revascularization procedure) was significantly lower (p=0.0004) in IDDM (60%) compared with non-IDDM (70%) and nondiabetic patients (76%). By multivariate analysis, IDDM was an independent predictor for any late cardiac event (OR=2.05, p=0.0002) in general and TLR (odds ratio=2.51, p=0.0001) in particular. CONCLUSIONS. In a large consecutive series of patients treated by elective stent implantation, IDDM patients were at higher risk for in-hospital mortality and subsequent TLR and, as a result, had a significantly lower cardiac event-free survival rate. On the other hand, acute and long-term procedural outcome was found to be similar for non-IDDM compared with nondiabetic patients.

Adult↗

Validation of the in vivo intravascular ultrasound measurement of in-stent neointimal hyperplasia volumes.

OBJECTIVES: This study was undertaken to validate the in vivo intravascular ultrasound (IVUS) measurement of in-stent neointimal hyperplasia (IH) volumes. BACKGROUND: Because stents reduce restenosis compared to balloon angioplasty, stent use has increased significantly. As a result, in-stent restenosis is now an important clinical problem. Serial IVUS studies have shown that in-stent restenosis is secondary to intimal hyperplasia. To evaluate strategies to reduce in-stent restenosis, accurate measurement of in-stent neointimal tissue is important. METHODS: Using a porcine coronary artery model of in-stent restenosis, single Palmaz-Schatz stents were implanted into 16 animals with a stent:artery ratio of 1.3:1. Intravascular ultrasound imaging was performed at 1 month, immediately prior to animal sacrifice. In vivo IVUS and ex vivo histomorphometric measurements included stent, lumen and IH areas; IH volumes were calculated with Simpson's rule. RESULTS: Intravascular ultrasound measurements of IH (30.4+/-11.0 mm3) volumes correlated strongly with histomorphometric measurements (26.7+/-8.5 mm3, r=0.965, p < 0.0001). The difference between the IVUS and the histomorphometric measurements of IVUS volume was 4.1+/-2.7 mm3 or 15.8+/-11% (standard error of the estimate=0.7). Both histomorphometry and IVUS showed that IH was concentric and uniformly distributed over the length of the stent. Intravascular ultrasound detected neointimal thickening of < or =0.2 mm in 5 of 16 stents. Sample size calculations based on the IVUS measurement of IH volumes showed that 12 stented lesions/arm would be required to show a 50% reduction in IVUS-measured IH volume and 44 stented lesions/arm would be required to show a 25% reduction in IH volume. CONCLUSION: In vivo IVUS measurement of IH volumes correlated strongly with ex vivo histomorphometry. Using volumetric IVUS end points, small sample sizes should be necessary to demonstrate effectiveness of strategies to reduce in-stent restenosis.

Angioplasty, Balloon, Coronary↗

Treatment of calcified coronary lesions with Palmaz-Schatz stents. An intravascular ultrasound study.

AIMS: To evaluate the result of coronary stenting in calcified lesions and to find morphological and procedural factors influencing the final result. METHODS AND RESULTS: Three hundred and twenty three native coronary artery lesions in 303 patients (197 men, mean age 63.9 +/- 11.5 years) treated with Palmaz-Schatz stents were differentiated into four groups depending on their degree of circumferential calcification as defined by intravascular ultrasound [0-90 degrees (n=120), 91-180 degrees (n=58, 181-270$ (n=71) and 271-360 degrees n=74)]. In 117 lesions rotational atherectomy was used prior to stent placement. Intravascular ultrasound and quantitative angiography were performed prior to treatment and after stent placement to measure minimal and maximal lumen diameter and lumen cross-sectional area at the lesion site and the reference segments. Acute lumen gain and eccentricity index were calculated. Although higher balloon pressures were used than in the minimally calcified lesions. the final angiographic minimal lumen diameter decreased with increasing arc of calcification (3.01 +/- 0.47, 3.04 +/- 0.43, 2.85 +/- 0.53, 2.83 +/- 0.40 mm, respectively, P=0.0320) resulting in a decrease in acute diameter gain with increasing arc of calcification (2.06 +/- 0.51, 1.91 +/- 0.46, 1.81 +/- 0.56, 1.78 +/- 0.51 mm, respectively, P=0.0067). Adjunctive rotational atherectomy prior to stent placement resulted in a greater acute diameter and a greater lumen cross-sectional area gain, coupled with less final residual stenosis than pre-treatment with balloon angioplasty. CONCLUSION: Implantation of stents in calcified lesions results in less optimal stent expansion, especially in lesions with thick, eccentric calcific plaque layers. Use of adjunctive rotational atherectomy before stent placement may improve the procedural result.

Aged↗

Treatment of in-stent restenosis.

Although in-stent restenosis is the result of neointimal hyperplasia, mechanical problems (e.g. stent underexpansion) that occurred during implantation may result in restenosis at follow-up. The treatment of in-stent restenosis, begins with identification of these occult mechanical problems. Thereafter, in-stent restenosis can be treated with PTCA, atheroablation, or additional stent implantation; it is nuclear which technique is superior. Not all in-stent restenosis lesions have a similar risk of recurrence. Recurrence appears to depend on several markers of biologic activity: focal vs diffuse in-stent restenosis, the first episode vs recurrent in-stent restenosis, and early vs late recurrence. Vascular brachytherapy has emerged as the most promising way to treat high-risk lesion subsets.

Angioplasty, Balloon, Coronary↗

Overestimation of acute lumen gain and late lumen loss by quantitative coronary angiography (compared with intravascular ultrasound) in stented lesions.

The accurate measurement of lumen dimensions is essential for guidance of interventional procedures and the assessment of acute and late results. This study compared intravascular ultrasound (IVUS) with quantitative coronary angiography (QCA) in the assessment of lumen dimensions before and after intervention, and at follow-up. Two hundred thirty-one consecutive patients treated with Palmaz-Schatz stents and evaluated using serial (before and after intervention, and follow-up) IVUS and QCA were screened. Because IVUS cannot measure dimensions smaller than the imaging catheter, patients having an angiographic minimal lumen diameter (MLD) less than the IVUS catheter (1.0 mm) during any study were excluded, leaving 71 patients in the final study group. IVUS and QCA measurements (reference dimensions and MLD) and calculations (percent diameter stenosis, acute lumen gain, late lumen loss, loss index, and restenosis rates) were compared. Correlation coefficients ranged from 0.641 to 0.816 for measured variables and from 0.280 to 0.680 for calculated variables. Reference lumen dimensions were consistently larger by IVUS than by QCA: 0.50 +/- 0.52 mm before intervention (p <0.0001), 0.46 +/- 0.45 mm after intervention (p <0.0001), and 0.38 +/- 0.53 mm at follow-up (p <0.0001). MLDs measured by IVUS were larger before intervention (0.17 +/- 0.28 mm, p <0.0001), smaller after intervention (0.17 +/- 0.34 mm, p <0.0001), and larger at follow-up (0.14 +/- 0.41 mm, p <0.0001). This resulted in a smaller acute gain and late loss measured by IVUS (0.33 +/- 0.39 and 0.30 +/- 0.47 mm, respectively, both p <0.0001). Although measures of restenosis (i.e., loss index and restenosis rates) were similar, the classification of lesions in individual patients (as restenotic vs nonrestenotic) was significantly different (p = 0.002, concordance rate = 73%). There are systematic differences between IVUS and QCA in the measurement of reference and lesion lumen dimensions. Although indexes of restenosis were similar, classification of lesions in individual patients was different.

Aged↗

Treatment of in-stent restenosis with excimer laser coronary angioplasty: mechanisms and results compared with PTCA alone.

BACKGROUND: This study determined the clinical safety, mechanisms, and 6-month results of excimer laser angioplasty (ELCA)+adjunct PTCA for the treatment of in-stent restenosis and (via lesion matching) compared the results of ELCA+PTCA to PTCA alone. METHODS AND RESULTS: Using quantitative angiography (QCA) and intravascular ultrasound (IVUS), we studied 107 restenotic previously stented lesions in 98 patients before and after intervention. QCA measurements included minimum lumen diameter (MLD) and diameter stenosis (DS). IVUS measurements included stent, lumen, and intimal hyperplasia (IH=stent-lumen) cross-sectional areas (CSA) and volumes. In the 54 lesions treated with ELCA+PTCA, the MLD increased from 0.73+/-0.38 mm before ELCA to 2.10+/-0.47 mm after ELCA+PTCA (P<.0001); the DS decreased from 70+/-14% to 25+/-12% (P<.0001). By IVUS, the minimum lumen CSA increased from 1.58+/-0.78 mm2 before ELCA to 6.34+/-1.75 mm2 after ELCA+PTCA (P<.0001) as a result of an increase in minimum stent CSA from 7.70+/-2.41 to 9.10+/-2.60 mm2 (P<.0001) and a decrease in IH CSA from 5.25+/-2.84 to 2.63+/-1.41 mm2 (P<.0001). Volumetric analysis showed that tissue ablation (during ELCA) contributed 29+/-15%, tissue extrusion (during adjunct PTCA) contributed 31+/-14%, and additional stent expansion (during adjunct PTCA) contributed 40+/-16% to the overall lumen gain. There were no ELCA-related complications. Matched to lesions treated with PTCA alone, ELCA+PTCA resulted in greater lumen gain, more IH ablation/extrusion, larger final lumen CSA (IVUS), and a tendency for less frequent need for subsequent target vessel revascularization (TVR, 21% versus 38%, P=.0823). CONCLUSIONS: ELCA safely and effectively ablates in-stent neointimal tissue. Adjunct PTCA extrudes neointimal tissue out of the stent and also further expands the stent. Compared with PTCA alone, ELCA+PTCA achieves better short-term and, potentially, better long-term results.

Angioplasty, Balloon, Coronary↗

Comparison of men versus women in cross-sectional area luminal narrowing, quantity of plaque, presence of calcium in plaque, and lumen location in coronary arteries by intravascular ultrasound in patients with stable angina pectoris.

Women have an increased mortality after coronary interventions compared with men, which may be partly explained by differences in comorbid clinical conditions. However, whether women also have quantitative differences in coronary atherosclerosis is not known. Preinterventional intravascular ultrasound (IVUS) was used to study de novo, nonostial native coronary lesions in 169 women and 549 men with chronic angina. The external elastic membrane (EEM), lumen, and plaque + media (P + M) areas, plaque burden, plaque eccentricity, and calcium were measured at the target lesion and at a proximal reference site. All cross-sectional IVUS measures were also corrected for body surface area. Results are reported as mean +/- 1 SD. Women had significantly smaller reference site EEM (16.5 +/- 5.3 vs 19.4 +/- 6.3 mm2, p <0.0001), lumen (8.7 +/- 3.0 vs 9.9 +/- 4.0 mm2, p = 0.0020), and P + M areas (7.8 +/- 3.7 vs 9.5 +/- 4.2 mm2, p = 0.0001). Women also had significantly smaller lesion site EEM (16.2 +/- 5.9 vs 18.3 +/- 6.7 mm2, p = 0.0028), lumen (2.4 +/- 1.7 vs 2.9 +/- 2.6 mm2, p = 0.0273), and P + M areas (13.6 +/- 5.7 vs 15.3 +/- 6.4 mm2, p = 0.0112). However, when corrected for BSA, these differences were no longer significant. Women and men also had similar reference and lesion plaque burden, eccentricity, and calcium. Preinterventional IVUS analysis failed to detect any quantitative or qualitative differences in coronary atherosclerosis in men compared with women.

Aged↗

Serial intravascular ultrasound predictors of restenosis at the margins of Palmaz-Schatz stents.

To evaluate predictors of restenosis at margins of Palmaz-Schatz stents, intravascular ultrasound studies were performed after intervention and at follow-up (5.4 months) in 161 stented lesions. Of 301 stent margins, 77 (26%) were restenotic at follow-up (>50% late lumen loss). Intimal hyperplasia was greater for restenotic than for nonrestenotic stents margins. The dominant periprocedural predictor of stent margin restenosis was the plaque burden of the continuous reference segment.

Coronary Disease↗