PubMed Health⌕ Search

Biomedical subjects

L Fägerstam

Publications and source records attributed to L Fägerstam.

5 recordsLinked to original sources

Analysis of active antibody concentration. Separation of affinity and concentration parameters.

Antibody binding to surfaces with differing amounts of immobilised antigen was measured in a biosensor system using surface plasmon resonance detection. Binding rates obtained during the initial binding phase on high density antigen surfaces were proportional to antibody concentration and independent of antigen-antibody affinity. One antibody calibration curve covering the range from 0.5 to 160 nM (0.08-25 micrograms/ml) antibody was valid for IgG antibodies with different antigen specificities. To illustrate the use of this methodology active antibody concentrations were analysed in culture media and in rabbit serum.

Animals↗

Lactose repressor-operator DNA interactions: kinetic analysis by a surface plasmon resonance biosensor.

Lactose repressor binding to operator DNA and subsequent dissociation of the complex was monitored continuously by a biosensor, measuring surface plasmon resonance. In this analysis a synthetic, double-stranded oligonucleotide containing the operator site was immobilized on the sensor surface and repressor protein was passed over the surface. The formation of the repressor-operator complex was specific and could be inhibited by isopropyl-beta-D-thiogalactopyranoside inducer. From the association curve, the apparent kass was determined to be 1.8 x 10(6) M-1 s-1. Dissociation of the complex was, for the first time for the lac repressor, determined as an uncatalyzed reaction and the kdiss was determined to be 3.4 x 10(-4) s-1. As a reference, the repressor-operator interaction was analyzed by electrophoretic mobility shift assay under similar reaction conditions. With this method the equilibrium binding constant was calculated to be 2.4 (+/- 0.2) x 10(8) M-1. The corresponding value calculated from biosensor data was 5.1 x 10(9) M-1.

Base Sequence↗

Introducing a biosensor based technology for real-time biospecific interaction analysis.

This report describes a system for real-time biospecific interaction analysis, using biosensor technology based on the optical phenomenon surface plasmon resonance. The biospecific interface is a sensor chip consisting of a thin gold film deposited on a glass support and covered with a hydrogel matrix. One component of the interaction being studied is attached covalently to the hydrogel, and other interactants are passed over the chip in solution. The interaction is followed in real time in terms of changes in the mass concentration of biomolecules at the sensor surface. Surface concentrations down to 10 pg/mm2 can be measured. The technique does not require molecular labels such as isotopes or spectroscopic markers, and purification of interacting components can often be avoided. Repeated analyses can be performed on the same sensor chip. With this system, the same general procedure can be used for a wide range of different applications, including concentration determination, kinetic measurements and multi-site binding studies. The sensitivity of the technique can be adjusted by choice of reagents and experimental procedure: determination of specific proteins in serum down to 20 ng/ml and macromolecular association constants from 10(7) M-1 up to 4 x 10(11) M-1 are documentated examples. No other single analytical system has the same versatility and general applicability to biospecific interaction analysis. The system is developed and marketed by Pharmacia Biosensor AB, Sweden.

Biosensing Techniques↗

Real-time biospecific interaction analysis using surface plasmon resonance and a sensor chip technology.

We report here the development and application of a biosensor-based technology that employs surface plasmon resonance for label-free studies of molecular interactions in real time. The sensor chip interface, comprising a thin layer of gold deposited on a glass support, is derivatized with a flexible hydrophilic polymer to facilitate the attachment of specific ligands to the surface and to increase the dynamic range for surface concentration measurements. The sensor can be used to measure surface concentrations down to 10 pg/mm2. Typical coefficients of variation are from two to five percent. We anticipate that the ability to monitor multi-molecular complexes as they form will greatly contribute to the understanding of biorecognition and the structural basis of molecular function.

Antibodies, Monoclonal↗

Purification and characterization of a low molecular weight 1,4-beta-glucan glucanohydrolase from the cellulolytic fungus Trichoderma viride QM 9414.

A low molecular weight 1,4-beta-glucan glucanohydrolase (endoglucanase) (1,4-(1,3;1,4)-beta-D-glucan 4-glucanohydrolase, EC 3.2.1.4) has been isolated from culture filtrates of the fungus Trichoderma viride QM 9414 by a two-step procedure of gel filtration and ion-exchange chromatography. The isolated enzyme appeared homogeneous upon polyacrylamide gel electrophoresis at pH 2.9, isoelectric focusing in a polyacrylamide gel slab, sedimentation equilibrium analysis and chromatography of the reduced and alkylated enzyme on a column of Sepharose 6B in 6 M guanidine - HCl. A molecular weight was calculated at approx. 20 000 and the isoelectric point was determined at pH 7.52. The purified enzyme was not a carbohydrate-containing protein.

Amino Acids↗