PubMed Health⌕ Search

Biomedical subjects

L Faes

Publications and source records attributed to L Faes.

5 recordsLinked to original sources

Causal transfer function analysis to describe closed loop interactions between cardiovascular and cardiorespiratory variability signals.

Although the concept of transfer function is intrinsically related to an input-output relationship, the traditional and widely used estimation method merges both feedback and feedforward interactions between the two analyzed signals. This limitation may endanger the reliability of transfer function analysis in biological systems characterized by closed loop interactions. In this study, a method for estimating the transfer function between closed loop interacting signals was proposed and validated in the field of cardiovascular and cardiorespiratory variability. The two analyzed signals x and y were described by a bivariate autoregressive model, and the causal transfer function from x to y was estimated after imposing causality by setting to zero the model coefficients representative of the reverse effects from y to x. The method was tested in simulations reproducing linear open and closed loop interactions, showing a better adherence of the causal transfer function to the theoretical curves with respect to the traditional approach in presence of non-negligible reverse effects. It was then applied in ten healthy young subjects to characterize the transfer functions from respiration to heart period (RR interval) and to systolic arterial pressure (SAP), and from SAP to RR interval. In the first two cases, the causal and non-causal transfer function estimates were comparable, indicating that respiration, acting as exogenous signal, sets an open loop relationship upon SAP and RR interval. On the contrary, causal and traditional transfer functions from SAP to RR were significantly different, suggesting the presence of a considerable influence on the opposite causal direction. Thus, the proposed causal approach seems to be appropriate for the estimation of parameters, like the gain and the phase lag from SAP to RR interval, which have a large clinical and physiological relevance.

Adult↗

Experimental approach for testing the uncoupling between cardiovascular variability series.

In cardiovascular variability analysis, the significance of the coupling between two series is commonly assessed by defining a zero level on the magnitude-squared coherence (MSC). Although the use of the conventional value of 0.5 does not consider the dependence of MSC estimates on the analysis parameters, a theoretical threshold Tt is available only for the weighted covariance (WC) estimator. In this study, an experimental threshold for zero coherence Te was derived by a statistical test from the sampling distribution of MSC estimated on completely uncoupled time series. MSC was estimated by the WC method (Parzen window, spectral bandwidth B = 0.015, 0.02, 0.025, 0.03 Hz) and by the parametric autoregressive (AR) method (model order M= 4, 8, 12, 16), on time series with length L = 180, 300, 420, 540 s. Te decreased with increasing B and L and with decreasing M (range: 0.11-0.54 for WC estimator, 0.06-0.46 for AR estimator). Values for the typical parameter settings of WC and AR estimation (B = 0.025 Hz; M = 8; L = 300 s) were, respectively, 0.24 and 0.17. Moreover, Tt was always higher (range: 0.12-0.65) and the results were less dependable than those for Te in defining the zero level of MSC. Thus, with the proposed method, the hypothesis of uncoupling is rejected by accounting for the parameters that affect the confidence of spectral and cross-spectral estimates. The broad applicability of this approach should favour its introduction for assessing the significance of the coupling between cardiovascular variability series.

Electrocardiography↗

Principal component analysis and cluster analysis for measuring the local organisation of human atrial fibrillation.

The distribution of atrial electrogram types has been proposed to characterise human atrial fibrillation. The aim of this study was to provide computer procedures for evaluating the local organisation of intracardiac recordings during AF as an alternative to off-line manual classification. Principal component analysis (PCA) reduced the data set to a few representative activations, and cluster analysis (CA) measured the average dissimilarity between consecutive activations of an intracardiac signal. The data set consisted of 106 bipolar signals recorded on 11 patients during electrophysiological studies for catheter ablation. Performances of PCA and CA in distinguishing between organised (type I) and disorganised (type II/III, Wells criteria) were assessed, in comparison with manual reading, by evaluating the predictive parameters of the classification analysis. Both methods gave high accuracy (92% for PCA and 89% for CA), confirming the feasibility of on-line characterisation of AF. Sensitivity was lower than specificity (81% against 98% for PCA, and 77% against 97% for CA), with seven out of eight misclassifications of PCA in common with CA. Differences between manual and computer analysis may be related to the higher resolution of PCA and CA in the measurement of the organisation of atrial activations. These procedures are suitable for providing automatic (by CA) or semi-automatic (by PCA) measures of the extent of local organisation of AF in the pre-ablation treatment phase.

Atrial Fibrillation↗

Causal linear parametric model for baroreflex gain assessment in patients with recent myocardial infarction.

Spectral and cross-spectral analysis of R-R interval and systolic arterial pressure (SAP) spontaneous fluctuations have been proposed for noninvasive evaluation of baroreflex sensitivity (BRS). However, results are not in good agreement with clinical measurements. In this study, a bivariate parametric autoregressive model with exogenous input (ARXAR model), able to divide the R-R variability into SAP-related and -unrelated parts, was used to quantify the gain (alpha(ARXAR)) of the baroreflex regulatory mechanism. For performance assessing, two traditional noninvasive methods based on frequency domain analysis [spectral, baroreflex gain by autogressive model (alpha(AR)); cross-spectral, baroreflex gain by bivariate autoregressive model (alpha(2AR))] and one based on the time domain [baroreflex gain by sequence analysis (alpha(SEQ))] were considered and compared with the baroreflex gain by phenylephrine test (alpha(PHE)). The BRS evaluation was performed on 30 patients (61 +/- 10 yr) with recent (10 +/- 3 days) myocardial infarction. The ARXAR model allowed dividing the R-R variability (950 +/- 1,099 ms(2)) into SAP-related (256 +/- 418 ms(2)) and SAP-unrelated (694 +/- 728 ms(2)) parts. alpha(AR) (12.2 +/- 6.1 ms/mmHg) and alpha(2AR) (8.9 +/- 5.6 ms/mmHg) as well as alpha(SEQ) (12.6 +/- 7.1 ms/mmHg) overestimated BRS assessed by alpha(PHE) (6.4 +/- 4.7 ms/mmHg), whereas the ARXAR index gave a comparable value (alpha(ARXAR) = 5.4 +/- 3.3 ms/mmHg). All noninvasive methods were significantly correlated to alpha(PHE) (alpha(ARXAR) and alpha(SEQ) were more correlated than the other indexes). Thus the baroreflex gain obtained describing the causal dependence of R-R interval on SAP showed a good agreement with alpha(PHE) and may provide additional information regarding the gain estimation in the frequency domain.

Analysis of Variance↗

[Indicators of continuous improvement of the transfer of neonatal emergency cases in the Trento province].

The nursing personnel of the Neonatology Unit of Trento Hospital cares for the transportation of newborns in the Trento Province (more than 7500 transportations have been performed to date). Aim of the study is the evaluation of the quality of care as documented in the ad hoc neonatal transportation data-bank. A further goal is the formulation and validation of simple and easy to collect indicators of "improvement of care". Examples of indicators used to assess the activities of the years 1996 and 1997 were the number of transportations with functioning equipment; the number of newborns with body temperature registered; the number of transportation cards correctly filled out. These simple indicators allowed to identify areas where the quality of care could be improved. The cause-effect diagram used allowed the involvement of all the nursing personnel in the identification of problems and of possible solutions. An example of the process followed for identifying and preventing hypothermia is presented and discussed.

Efficiency, Organizational↗