PubMed Health⌕ Search

Biomedical subjects

L Fanning

Publications and source records attributed to L Fanning.

16 recordsLinked to original sources

Do Taq-generated RT-PCR products from RNA viruses accurately reflect viral genetic heterogeneity?

Since the first report of genetically heterogeneous, or quasispecies, populations of RNA viruses, the genetic heterogeneity of the RNA genomes of major viral pathogens has been extensively studied. These studies aim to provide insights into the evolutionary pressures that act upon viruses, in order to define windows where anti-viral therapies will be most effective, to take prognostic values from viral genetic distributions at a given time, and to aid the development of novel therapeutic compounds that may tilt viral replication towards information loss. Many methodologies are employed to analyse genetic distributions of a virus in a given sample, but all involve the generation, and subsequent analysis, of the sequence information contained in a reverse-transcription-polymerase chain reaction (RT-PCR) product. Despite the fact that the aim of these RT-PCRs is to obtain sequence information from viral genomes, their application to this task is approached without adequate consideration of this end-goal. The establishment of an RT-PCR for a specific viral target genome generally proceeds in the same fashion as one would apply to establishing a PCR to determine the presence or absence of a specific target sequence in a given sample. However, it is becoming increasingly apparent that RT-PCR products generated by amplification with the ubiquitous thermostable DNA polymerase Taq, coupled with standard cloning and sequencing methodologies, has the potential to yield inaccurate and misleading data as pertains to the information content of populations of RNA viral genomes. This review discusses varying approaches employed to analyse heterogeneous populations of hepatitis C virus RNA genomes.

Base Pair Mismatch↗

Purification and some characteristics of a recombinant dimeric rhizobium meliloti beta-galactosidase expressed in escherichia coli.

A recombinant Rhizobium meliloti beta-galactosidase was purified to homogeneity from an Escherichia coli expression system. The gene for the enzyme was cloned into a pKK223-3 plasmid which was then used to transform E. coli JM109 cells. The enzyme was purified 35-fold with a yield of 34% by a combination of DEAE-cellulose (pH 8.0) and two sequential Mono Q steps (at pH 8.0 and 6.0, respectively). The purified enzyme had an apparent molecular mass of 174 kDa and a subunit molecular weight of 88 kDa, indicating that it is a dimer. It was active with both synthetic substrates p-nitrophenyl beta-D-galactopyranoside (PNPG) and o-nitrophenyl beta-D-galactopyranoside (ONPG) with K(m)(PNPG) and K(m)(ONPG) of 1 mM at 25 degrees C. The k(cat)/K(m) ratios for both substrates were approximately 70 mM(-1) sec(-1), indicating no clear preference for either PNPG or ONPG, unlike E. coli beta-galactosidase. After non-denaturing electrophoresis, active beta-galactosidase bands were identified using 5-bromo-4-chloro-3-indolyl beta-D-galactopyranoside (X-gal) or 6-bromo-2-naphthyl beta-D-galactopyranoside (BNG) and diazo blue B.

Journal Article↗

Strategy for the maximization of clinically relevant information from hepatitis C virus, RT-PCR quantification.

BACKGROUND: The increasing clinical application of viral load assays for monitoring viral infections has been an incentive for the development of standardized tests for the hepatitis C virus. OBJECTIVE: To develop a simple model for the prediction of baseline viral load in individuals infected with the hepatitis C virus. METHODOLOGY: Viral load quantification of each patient's first sample was assessed by RT-PCR-ELISA using the Roche MONITOR assay in triplicate. Genotype of the infecting virus was identified by reverse line probe hybridization, using amplicons resulting from the qualitative HCV Roche AMPLICOR assay. RESULTS: Retrospective evaluation of first quantitative values suggested that 82.4% (n=168/204) of individuals had a viral load between 4.3 and 6.7 log(10) viral copies per ml. A few patients (3.4%; n=7/204) have a serum viremia less than the lower limit of the linear range of the RT-PCR assay. Subsequent, prospective evaluation of hepatitis C viral load of all new patients using a model based on the dynamic range of viral load in the retrospective group correctly predicted the dynamic range in 75.9% (n=33/54). CONCLUSION: The dynamic range of hepatitis C viremia extends beyond the linear range of the Roche MONITOR assay. Accurate determination of serum viremia is substantially improved by dilution of specimens prior to quantification.

DNA, Viral↗

Tissue viral load variability in chronic hepatitis C.

OBJECTIVE: Liver biopsy is regarded as the gold standard for assessing disease activity in chronic hepatitis C, but sampling error is a potential limitation. Whether sampling variability applies equally to viral load assessment as it does to histology is uncertain. To examine this, we compared viral load between right- and left-lobe biopsy specimens from patients infected with hepatitis C virus (HCV). METHODS: Bilobe biopsies were taken from 16 patients who were serum positive for HCV RNA by reverse transcription-polymerase chain reaction. Genotype was identified by reverse line probe hybridization. There was an absence of competing risk factors for infectious and other liver diseases in this patient group. Histology and hepatic viral load were assessed blindly. None of the patients had received antiviral therapy at the time of study. RESULTS: Detection of HCV in right and left lobes was concordant with serum positivity in all cases. The viral load between lobes was highly correlated (p = 0.0003, r = 0.79). In contrast, the histological activity indices of inflammation and fibrosis/cirrhosis were poorly correlated between lobes (p = 0.038, r = 0.60, and p = 0.098, r = 0.50, respectively). CONCLUSION: Hepatic viral load variability does not suffer from the same degree of heterogeneity of sampling variability as does histology.

Adult↗

Natural fluctuations of hepatitis C viral load in a homogeneous patient population: a prospective study.

The aim of this study was to determine the variation in hepatitis C viral load over an extended period of patient follow up. Serum samples were collected from 49 female individuals who were identified as having been infected from the same source of hepatitis C-contaminated anti-D immunoglobulin during the period from 1977 (May) to 1978 (November). All patients attended the hepatitis C clinic at Cork University Hospital, Cork, Ireland. The study group was homogeneous with respect to gender, hepatitis C virus (HCV) genotype (1b), and duration of infection. None of the patients had received antiviral therapy at the time of completion of study. Viral load quantifications were assessed using the Roche Monitor (F. Hoffmann-La Roche, Ltd., Basel, Switzerland) assay. The mean age of the study group at time of infection was 30.3 years (SD +/- 6.1) with a range from 18.5 to 43 years. The mean time of follow-up was 4. 1 years (SD +/- 1.0) with a range from 1.2 to 5 years. The mean rate of change of viral load per year was 0.23 log(10) viral copies per mL serum for the study group (SD +/- 0.19) with a range of -0.18 to 0.78 that was significantly different from zero, P < 10(-10). The rate of change of viral load per year was negatively correlated with viral load at first determination, r = -.35, P =.01. Age at infection did not correlate with the slope of change of viral load, P =.10. In conclusion, most women infected with HCV 1b will have an increase in viral load over time but a few patients who acquire infection early in adult life will show a decrease in viral load.

Adolescent↗

Pregnancy and pregnancy outcome in hepatitis C type 1b.

A large cohort of rhesus-negative women in Ireland were inadvertently infected with hepatitis C virus following exposure to contaminated anti-D immunoglobulin in 1977-8. This major iatrogenic episode was discovered in 1994. We studied 36 women who had been infected after their first pregnancy, and compared them to an age- and parity-matched control group of rhesus-positive women. The presence of hepatitis C antibody was confirmed in all 36 by enzyme-linked immunosorbent assay and by recombinant immunoblot assay, while 26 (72%) of the cohort were HCV-RNA-positive (type 1b) on PCR testing. In the 20 years post-infection, all members of the study group had at least one pregnancy, and mean parity was 3.5. They had a total of 100 pregnancies and 85 of these went to term. There were four premature births, one being a twin pregnancy, and 11 spontaneous miscarriages. One miscarriage occurred in the pregnancy following HCV infection. There were two neonatal deaths due to severe congenital abnormalities in the PCR-positive women. Of the children born to HCV-RNA positive mothers, only one (2.3%) tested positive for the virus. Significant portal fibrosis on liver biopsy was confined to HCV-RNA-positive mothers apart from one single exception in the antibody-positive HCV-RNA-negative group. Comparison with the control group showed no increase in spontaneous miscarriage rate, and no significant difference in obstetric complications; birth weights were similar for the two groups.

Adult↗

Viral load and clinicopathological features of chronic hepatitis C (1b) in a homogeneous patient population.

Monitoring the progression of hepatitis C virus (HCV) includes clinical, biochemical, and histological parameters. Quantitation of viral load by reverse-transcription polymerase chain reaction (RT-PCR) may offer a more reliable marker of disease status. Conflicting reports on viral titers may reflect heterogeneity of patient population, mode of infection, and viral type/subtype. The aim of this study was to correlate quantitative serum viral load with alanine transaminase (ALT) and histological status in a homogenous population. The study population consisted of 77 Rhesus-negative women with chronic hepatitis C type 1b. Homogenous features of this study population included: same defined source of infection (contaminated anti-D immunoglobulin); same duration of disease (17 years at the time of study); same viral type/subtype; same ethnic origin; all healthy child-bearing females at the time of infection; and an absence of competing risk factors for infectious and other liver diseases. None of the patients had received antiviral treatment at the time of study. Liver biopsy was performed on all patients. All biopsies were scored by a single histopathologist who was blinded to the clinical and viral status of each patient. A weak, but statistically significant, correlation (rs =.26; P <.05) between serum viral load and the degree of inflammation (mean value: 3.87 +/- 2.17 [SD]) was found. There was no significant correlation between serum viral load and the degree of fibrosis (mean value: 0.84 +/- 0.8 [SD]; P =.06). There was no significant correlation between serum viral load and ALT, although there was a correlation between ALT and the degree of inflammation (rs =.241; P =.035).

Adult↗

Molecular mechanisms involved in receptor editing at the Ig heavy chain locus.

In receptor editing, a phenomenon that has recently come to light and into favor, a rearranged VDJ or VJ gene segment encoding a variable region of an Ig chain is replaced by another. In this commentary, the molecular mechanisms involved in the editing process are examined in some detail. Editing is most likely mediated by the same V(D)J recombinase activity responsible for the formation of the original VDJ or VJ segment. An embedded heptamer, which is present near the 3' end of many VH elements, is used as the recombination signal sequence at the Ig heavy chain locus. It has been postulated that the mediation of receptor editing is the evolutionary force maintaining the embedded heptamer. Some of the evidence for and against this hypothesis is discussed.

Animals↗

Effect of temperature reduction on myotonia in rat skeletal muscles in vitro.

1. The objective of the study was to determine the effect of temperature reduction on the response of rat skeletal muscles to myotonia-inducing agents. 2. A model myotonia was induced in the muscles in vitro, using either the chloride channel blocker anthracene-9-carboxylic acid or chloride-free Krebs solution. This model is similar in its characteristics to the myotonia which occurs in autosomal recessive generalized myotonia congenita in humans. 3. Isometric twitch contractions were recorded in the muscles in Krebs solution before and after the addition of the myotonia-inducing agent. The presence of myotonia was confirmed when the half-relaxation time of the twitch contraction after the addition of the agent was significantly greater than that before its addition. 4. Recordings were made at 37 degrees C, 30 degrees C, 25 degrees C and 15 degrees C. Myotonia developed at 37 degrees C, 30 degrees C and 25 degrees C, but not at 15 degrees C, indicating that at a temperature between 25 degrees C and 15 degrees C, anthracene-9-carboxylic acid-induced myotonia failed to develop. This supports the results obtained in humans suffering from myotonia congenita where myotonic contractions in the adductor pollicis muscle disappeared when the muscle temperature was cooled to 20 degrees C. 5. The myotonia which developed at 37 degrees C could be significantly reduced by exposure to 1 x 10(-4) mol/l ouabain or by elevation of the K+ concentration of the Krebs solution to 7.5 mmol/l. 6. Measurements made using microelectrodes showed that the conditions under which myotonia either did not develop or was significantly reduced, i.e. a temperature of 15 degrees C, exposure to 7.5 mmol/l K+ at 37 degrees C or exposure to 1 x 10(-4) mol/l ouabain at 37 degrees C were each associated with membrane depolarization. The results are discussed in terms of a possible role for depolarization in preventing/reducing the myotonic response.

Animals↗

Purification and characterization of an endonuclease from fruiting caps of basidiomycete Coprinus cinereus.

An endonuclease was purified from the cap tissues of basidiocarp of Coprinus cinereus collected at early meiotic prophase. It has an optimal activity at pH 7.0 and 37 degrees C. It is a cationic enzyme with a molecular mass of 22 kDa by gel filtration, and contains a 12-kDa and a 14-kDa peptide as revealed by SDS gel electrophoresis and Western blot analysis. An antiserum was produced in rabbits against the purified Coprinus endonuclease. The specificity of this antiserum was demonstrated in a dot-blot analysis and, more critically, in an immunoinhibition of endonuclease activity. The Coprinus endonuclease requires Mg2+ and/or Ca2+ as co-factors. Ca2+ is more efficient than Mg2+ while the effect of combining both co-factors is the highest. The Coprinus endonuclease has a substrate preference for single-strand and supercoiled DNA. It gives only single-strand nicks on supercoiled DNA at low enzyme concentration and limited time of incubation. At high enzyme concentration and/or long incubation time, double-strand fragmentation occurred. As is discussed, this endonuclease is believed to be involved in the early phase of meiotic recombination.

Agaricales↗

Sperm acrosin levels in semen: comparison between ACCU-SPERM and Kennedy's methods.

The purpose of this experiment was to evaluate the accuracy, specificity, and sensitivity of a new acrosin activity assay, ACCU-SPERM, and to correlate these results with the original Kennedy method. Thirty-nine specimens (26 patients and 13 donors) of 54 (72%) were found to be in the normal range (> 25 microIU acrosin/10(6) sperm) by the Kennedy method; the other 15 specimens were in either the indeterminate or subfertile range (< 14 microIU). However, according to the ACCU-SPERM method, (normal: 6.6-27 AAI; infertile: < 3.6), 90% of specimens (49 of 54) whose acrosin activity was measured were in the subfertile or infertile range. Similarly, only 28% (4 of 14) of donors in the ACCU-SPERM method were in the normal range in contrast to the 93% (13 of 14) in Kennedy. After calculating the ACCU-SPERM normal range in our laboratory using the linear regression curve between the acrosin values generated by the Kennedy and ACCU-SPERM methods, we again compared results of the two methods. The new normal range of > 1.82 AAI in ACCU-SPERM corresponded to > 25 microIU in the Kennedy method; similarly a value of < 1.35 AAI in ACCU-SPERM corresponded to < 14 microIU in the Kennedy technique. Analysis of the results generated by the two methods revealed a poor correlation with a positive concordance of 51% and a negative concordance of 50% in both assays. These results strongly suggest that the ACCU-SPERM method for measurement of acrosin activity is not a reliable assay.

Acrosin↗

Improvement in membrane integrity and acrosin levels of human sperm by use of L4 membrane.

Previous results have demonstrated the advantage of using an L4 filter as a method for sperm preparation is assisted reproductive techniques. The present study examined the effect of two sperm processing methods (L4 filter and swim-up) on sperm acrosin levels and the integrity of the sperm membrane as measured by the hypoosmotic swelling (HOS) test. Semen specimens from 35 men (19 suspected subfertile men and 16 normal volunteers) were used to measure acrosin activity; 30 specimens (14 patients and 16 normal men) were used to assess the integrity of sperm membrane by the HOS test. The acrosin activity of L4-filtered spermatozoa (mean 110 +/- 85 microIU acrosin/10(6) sperm) in patients and donors was significantly higher (p < .002) than in either the swim-up specimens (76 +/- 58 microIU) or original unprocessed ejaculate (46 +/- 27 microIU). Similarly, the percentage of tail swelling measured by HOS test was significantly higher (p < .01) in the L4-filtered sperm (mean 71 +/- 13%) than in either swim-up specimens (59 +/- 18%) or original ejaculate (61 +/- 10%). These results clearly demonstrate improvement in two important functional parameters of sperm fertilizing ability in sperm processed by the L4-filter technique, thereby providing new evidence in support of the use of L4 filters for sperm processing.

Acrosin↗

Generation of reactive oxygen species by leukocytes and sperm following exposure to urogenital tract infection.

The association between male urogenital tract infection (UTI) and infertility is still controversial. Oxidative stress caused by reactive oxygen species (ROS) in semen has been suggested to be an important factor in the etiology of poor sperm function through peroxidative damage to the cell membrane. This study explored the potential association between the ROS generation and UTIs by examining ROS production by sperm and seminal leukocytes in response to various infectious and cytokine stimulating factors. Semen and blood samples were obtained from 17 normal donors. Highly motile pure sperm, poorly motile sperm, and polymorphonuclear leukocytes (PMN) were isolated and exposed to various infectious and stimulating factors, including lipopolysaccharide (LPS), gamma interferon (gamma-IFN), tumor necrosis factor-alpha (TNF-alpha), granulocyte, macrophage-colony stimulating factor (GM-CSF), and phorbol myristate acetate (PMA). ROS generation was determined by measuring luminescence in a luminometer. In this study, purified PMNs produced high levels of ROS, and this production was markedly enhanced in the presence of cytokines, LPS, as well as PMA. Pure motile sperm produced low levels of ROS, and ROS production was not enhanced by addition of bacterial products or cytokines. In conclusion, PMNs in semen are the major source of ROS, and ROS production by these cells is enhanced by bacterial products and cytokines. Detection of activation markers and/or soluble factors produced by activated leukocytes in the urogenital tract or semen could enhance the diagnosis and lead to improved therapy of male infertility due to subclinical genital tract infections.

Adult↗

Deoxyribonucleic acid hybridization method for the detection of Listeria in dairy products, seafoods, and meats: collaborative study.

The method is based on the hybridization of synthetic deoxyribonucleic acid probes to ribosomal ribonucleic acid sequences unique to Listeria. This method was compared to 2 culture methods: the U.S. Food and Drug Administration method for the detection of Listeria in dairy products and seafoods and the U.S. Department of Agriculture, Food Safety and Inspection Service method for Listeria in meats. Six food types with replicate samples containing various concentrations of Listeria were analyzed by the collaborating laboratories. Listeria was detected in 774 samples using the DNAH method and in 772 samples using a culture method. The DNAH and culture methods were in agreement for 668 samples containing Listeria and 306 samples without Listeria. The overall rate of agreement between methods was 82.3%. The method has been adopted first action by AOAC INTERNATIONAL.

Animals↗