Detection of hemodynamic changes in clinical monitoring by time-delay neural networks.

Small changes that occur in a patient's physiology over long periods of time are difficult to detect, yet they can lead to catastrophic outcomes. Detecting such changes is even more difficult in intensive care unit (ICU) environments where clinicians are bombarded by a barrage of complex monitoring signals from various devices. Early detection accompanied by appropriate intervention can lead to improvement in patient care. Neural networks can be used as the basis for an intelligent early warning system. We developed time-delay neural networks (TDNN) for classifying and detecting hemodynamic changes. A matrix of physiological parameters were extracted from raw signals collected during cardiovascular experiments in mongrel dogs. These matrices represented several episodes of stable, decreasing, and increasing cardiac filling in normal, exerted, and heart failure conditions. The TDNN were trained with these matrices and subsequently tested to predict unseen cases. The TDNN perform remarkably not only in identifying all hemodynamic conditions, but also in quickly detecting their changes. On average, the networks were able to detect the hemodynamic changes in less than 1 s after the onset. Based on the results of this pilot investigation, the use of this form of TDNN to successfully predict hemodynamic conditions appears to be promising.

Animals↗

Determinants of aortic pressure variation during positive-pressure ventilation in man.

STUDY OBJECTIVES: To define the relation between systolic arterial pressure (SAP) changes during ventilation and left ventricular (LV) performance in humans. DESIGN: Prospective repeat-measures series. SETTING: University of Pittsburgh Medical Center Operating Room. PATIENTS: Fifteen anesthetized cardiac surgery patients before and after cardiopulmonary bypass when the mediastinum was either closed or open. INTERVENTIONS: Positive-pressure ventilation. MEASUREMENTS AND RESULTS: SAP and LV midaxis cross-sectional areas were measured during apnea and then were measured for three consecutive breaths. SAP increased during inspiration, this being the greatest during closed chest conditions (p < 0.05). Changes in SAP could not be correlated with changes in either LV end-diastolic areas (EDAs), end-systolic areas, or stroke areas (SAs). If SAP decreased relative to apnea, the decrease occurred during expiration and was often associated with increasing LV EDAs and SAs. SAP often decreased after a positive-pressure breath, but the decrease was unrelated to SA deficits during the breath. Increases in SAP were in phase with increases in airway pressure, whereas decreases in SAP, if present, followed inspiration. No consistent relation between SAP variation and LV area could be identified. CONCLUSIONS: In this patient group, changes in SAP reflect changes in airway pressure and (by inference) intrathoracic pressure (as in a Valsalva maneuver) better than they reflect concomitant changes in LV hemodynamics.

Aorta↗

Isolated lower esophageal sphincter relaxation as "wave-suppressed" secondary peristalsis.

Esophageal venting following air insufflation may occur by secondary peristalsis or by isolated transient lower esophageal sphincter relaxation (TLESR). To identify factors determining venting by these two mechanisms, we analyzed the responses to esophageal air insufflation in 4 infants and in 2 adults. We used a nine-lumen dual-Dent-sleeve manometric catheter with an air insufflation esophageal side hole, identifying swallowing by pharyngeal manometry or submental electromyography. The time from the venting lower esophageal sphincter relaxation (whether part of a secondary peristalsis or an isolated TLESR) to the next swallow (whether spontaneous, in the infants, or on command, in the adults) was characterized as > or = 15 sec or < 15 sec. Of the 25 evaluable trials, the subsequent swallow was > or = 15 sec after the venting response in 9 instances and < 15 sec afterward in 16 instances. Eight of the 9 trials with delayed swallows (> or = 15 sec) were vented by secondary peristalsis, whereas 11 of the 16 with early swallows (< 15 sec) were vented by TLESR (X2 p < 0.01). TLESRs may be induced by esophageal stimuli, in which case they may represent "wave-suppressed" secondary peristaltic complexes.

Adult↗

Changes in electrocardiographic morphology reflect instantaneous changes in left ventricular volume and output in cardiac surgery patients.

We examined the relation between changes in R-to-T wave amplitude ratios (R:T) and left ventricular (LV) performance as cardiac output was rapidly varied by inferior vena caval occlusion in 6 subjects prior to cardiopulmonary bypass. To assess the influence of contractility, paired studies before and after bypass were performed in 4 subjects. Stroke volume and cardiac output were assessed by aortic flow probe, and transesophageal echocardiographic LV area measures using the automated border-detection method were used to give LV stroke area, stroke force, maximal LV area, fractional area change, end-systolic elastance, and preload recruitable stroke force. Data were collected on computer and analyzed by linear regression. Significant changes in R:T and measured LV variables during the inferior vena caval occlusion were stroke volume (r = 0.81), LV stroke area (r = 0.77), LV stroke force (r = 0.81), maximal LV area (r = 0.78), and cardiac output (r = 0.80). However, R:T varied inconsistently in relation to fractional area change. After cardiopulmonary bypass, the linear relation between R:T with LV stroke force, LV stroke volume, and maximal LV area persisted, but at a lesser slope. Although absolute pre-inferior vena caval occlusion R:T did not correlate with end-systolic elastance or preload recruitable stroke force, the change in the slope of these linear relations correlated well with the change in end-systolic elastance after surgery (r = 0.92). Instantaneous changes in electrocardiographic morphology reflect changes in LV preload-dependent variables, whereas long-term changes in electrocardiographic morphology may also reflect changes in contractile state.

Aged↗

A system for the on-line acquisition, visualization, and analysis of pressure-area loops.

Transesophageal echocardiography is a widely accepted technique for the assessment of left ventricular (LV) function in the operating room, intensive care unit, and cardiac catheterization suite. Not only do the images generated by these systems provide the observer with dynamic views of currently ongoing cardiac mechanics, but the computed LV area values obtained by the automated border detection system can be converted to an analog signal and then used to generate pressure-area loops if LV pressure is measured simultaneously. The intraventricular area has been shown to correlate closely with intraventricular volume and to vary proportionately. Therefore, it can be substituted for volume to generate pressure-area loops that display equivalent behavior to external perturbations as pressure-volume loops. Visualization of these waveforms and the values extracted from them, along with the associated hemodynamic values, provide valuable insight into ventricular function and heart-lung interactions. This paper describes a system that was designed and developed to acquire, display, store, and analyze pressure-area loops in addition to other associated hemodynamic signals of interest.

Computer Systems↗

Estimation of left ventricular compliance using on-line echocardiographic automated border detection and pressure data.

The end-diastolic pressure-volume relationship can be used to describe left ventricular (LV) compliance. The objective of this study was to utilize measurements of LV cavity area by echocardiographic automated border detection and pressure data to estimate the end-diastolic pressure-volume curve in an isolated heart preparation where true volume could be measured by an intraventricular balloon. Six dog hearts were excised for placement of an intraventricular balloon and a micromanometer catheter and perfused in an ex vivo circuit. Mid-ventricular short-axis images were used to measure cross-sectional area by automated border detection while LV volumes were increased from 5 ml to maximal volume (30-40 ml) in each preparation. Simultaneous area and pressure data were recorded on a computer workstation through a customized interface with the ultrasound system. Three runs of varying LV volumes at 1 ml increments were performed on each of 6 hearts for a total of 1,080 simultaneous measurements. Pressure-volume and pressure-area curves were analyzed by linear regression analyses, the slope of which was used to estimate compliance. End-diastolic pressure-area and pressure-volume relationships were significantly correlated with mean r = 0.97 +/- 0.02 (p < 0.001) from individual hearts. The slopes which served to estimate compliance of the individual pressure-area and pressure-volume curves were similar and differed by only 7 +/- 4%. A similar correlation was observed by second order regression analyses with r = 0.97 +/- 0.01 (p < 0.001) for pressure-area and r = 0.98 +/- 0.01 (p < 0.001) for pressure-volume relationships.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Assessment of left ventricular performance by on-line pressure-area relations using echocardiographic automated border detection.

OBJECTIVES: The purpose of this study was to evaluate left ventricular performance by on-line pressure-area relations using echocardiographic automated border detection in the in situ canine heart in a manner similar to pressure-volume analyses. BACKGROUND: Echocardiographic automated border detection can measure ventricular cavity area as an index of volume and may be interfaced with pressure to construct pressure-area loops on-line. METHODS: Eight anesthetized open chest dogs had simultaneous measurement of ventricular pressure, aortic flow and midventricular short-axis area. Pressure-area loops were constructed by a computer workstation interfaced with the ultrasound system. Stroke area (Maximal area--Minimal area) and stroke force (integral of P dA [P = pressure; A = area]) values during inferior vena cava (n = 8) and aortic (n = 4) occlusions were compared with stroke volume and estimates of stroke work, respectively. Inotropic modulation was induced with dobutamine infusion (2 to 5 micrograms/kg body weight per min), followed by propranolol infusion (2 to 5 mg). End-systolic and maximal elastance and preload recruitable stroke force (stroke force versus end-diastolic area) were derived for each period. RESULTS: Changes in stroke area and stroke force were significantly correlated with changes in stroke volume and estimates of stroke work during caval occlusion (n = 8) (r = 0.87 +/- 0.02, SEE = 8 +/- 1% and r = 0.90 +/- 0.03, SEE = 8 +/- 2%, respectively). In dogs with aortic occlusion (n = 4), changes in stroke area significantly correlated with changes in stroke volume for pooled data (r = 0.84, SEE = 8%, y = 1.0x + 3). Ventricular performance increased with dobutamine infusion (n = 7): end-systolic elastance 30 +/- 11 to 67 +/- 24 mm Hg/cm2 (p < 0.02 vs. control values); maximal elastance 37 +/- 11 to 82 +/- 26 mm Hg/cm2 (p < 0.02 vs. control values); preload recruitable stroke force 81 +/- 24 to 197 +/- 92 mm Hg (p < 0.02 vs. control values). Decreases occurred with propranolol infusion (n = 5) end-systolic elastance 20 +/- 4 to 13 +/- 4 mm Hg/cm2 (p < 0.002 vs. control values); maximal elastance 29 +/- 8 to 15 +/- 5 mm Hg/cm2 (p < 0.002 vs. control values); preload recruitable stroke force 66 +/- 14 to 40 +/- 9 mm Hg (p < 0.002 vs. control values). CONCLUSIONS: On-line pressure-area relations are a potentially useful means to assess left ventricular performance in a manner that is quantitatively similar to the predicted responses of pressure-volume relations.

Animals↗

Rapid estimation of left ventricular contractility from end-systolic relations by echocardiographic automated border detection and femoral arterial pressure.

BACKGROUND: Automated echocardiographic measures of left ventricular (LV) cavity area are closely correlated with changes in volume and can be coupled with LV pressure to construct pressure-area loops in real time. The objective was to rapidly estimate LV contractility from the end-systolic relations of cavity area (as a surrogate for LV volume) and femoral arterial pressure (as a surrogate for LV pressure) in patients undergoing cardiac surgery. METHODS: Studies were attempted on 18 consecutive patients with recordings of LV pressure, LV area, and femoral arterial pressure on a computer workstation interfaced with the ultrasound system. End-systolic pressure-area relations (in terms of pressure-area elastance [E'es]) from pressure-area loops during inferior vena caval occlusions were determined before and immediately after cardiopulmonary bypass using both LV and arterial pressure by semiautomated and automated iterative linear regression methods. RESULTS: Data sets were available for 13 patients before and 8 patients after bypass (21 studies in 14 patients). E'es by arterial pressure was closely correlated with E'es by LV pressure: r = 0.96, standard error of the estimate = 2 mmHg/cm2, y = 1.01 x -0.7 by the semiautomated method and r = 0.94, standard error of the estimate = 3 mmHg/cm2, y = 1.02 x -0.5 by the automated method. Analysis of semiautomated and automated estimates of E'es from arterial pressure and E'es using LV pressure by the Bland-Altman method showed no systematic measurement bias and calculated limits of agreement of 8 and 9 mmHg/cm2, respectively. Similar decreases in E'es by arterial and LV pressure occurred from before to after bypass in 7 patients with paired data sets: 32 +/- 12 to 15 +/- 6 mmHg/cm2 and 32 +/- 15 to 15 +/- 7 mmHg/cm2, respectively (P < 0.05 for both). CONCLUSIONS: On-line femoral arterial pressure and LV area data by echocardiographic automated border detection may be used to rapidly calculate E'es as a means to estimate LV contractility in selected patients.

Adult↗

Assessment of the immediate effects of cardiopulmonary bypass on left ventricular performance by on-line pressure-area relations.

BACKGROUND: Pressure-volume relations have been established as useful measures of left ventricular (LV) performance. Application of these methods to the intraoperative setting have been limited because of difficulties acquiring LV volume data. Transesophageal echocardiographic automated border detection can measure LV cross-sectional area as an index of volume, which can be coupled with pressure data to construct pressure-area loops on-line. The purpose of this study was to evaluate intraoperative LV performance in patients undergoing coronary bypass surgery before and immediately after cardiopulmonary bypass using on-line pressure-area relations. METHODS AND RESULTS: Studies were attempted in 13 consecutive patients. Simultaneous measures of LV cross-sectional area, LV pressure, and electromagnetic flow probe-derived aortic flow recorded on a computer work station interfaced with the ultrasound system. Pressure-area loops were compared with simultaneous pressure-volume loops constructed from pressure and flow data during inferior vena caval occlusions before and after bypass. Pressure-volume calculations (end-systolic elastance, maximal elastance, and preload-recruitable stroke work) were then applied to pressure-area loops with area substituted for volume data. Changes in stroke force from pressure-area loops were closely correlated with changes in estimates of stroke work from pressure-volume loops for individual patients before bypass (r = .99 +/- .03, SEE = 5 +/- 2%, n = 10) and after bypass (r = .96 +/- .05, SEE = 5 +/- 2%, n = 9). Pressure-area estimates of end-systolic elastance, maximal elastance, and preload-recruitable stroke force decreased significantly from before to after cardiopulmonary bypass in the 7 patients with paired data sets. Load-dependent measures of LV function (stroke volume, cardiac output, and fractional area change) were unchanged after surgery in these same patients. CONCLUSIONS: Intraoperative pressure-area loops may be acquired and displayed on-line using transesophageal echocardiographic automated border detection and readily analyzed in a manner similar to pressure-volume loops. LV performance was depressed immediately after cardiopulmonary bypass compared with before. On-line pressure-area relations may be clinically useful to assess LV performance in patients undergoing cardiac surgery in whom load and contractility may be expected to vary rapidly.

Aged↗

On-line estimation of changes in left ventricular stroke volume by transesophageal echocardiographic automated border detection in patients undergoing coronary artery bypass grafting.

Echocardiographic automated border detection can determine the interface between blood and myocardial tissue and calculate left ventricular (LV) cavity area in real-time. The objective was to determine if on-line measurements of LV cavity area by transesophageal automated border detection could be used to determine beat-to-beat changes in stroke volume in humans. Studies were attempted on 9 consecutive patients, aged 66 +/- 8 years, undergoing coronary bypass surgery. Stroke volume was measured by electromagnetic flow from the ascending aorta, and LV cavity area was measured at the midventricular short-axis level. Simultaneous area and flow data were recorded on a computer workstation through a customized interface with the ultrasound system. Recordings were performed during baseline apnea and rapid alterations induced by inferior vena caval occlusions before and after cardiopulmonary bypass. Measurements of stroke area (maximal area-minimal area) were correlated with stroke volume for matched beats. Data were available for analysis on 8 of 9 patients before and on 5 patients after cardiopulmonary bypass for 644 beats. Stroke area was closely correlated with stroke volume both before (mean R = 0.94 +/- 0.03, SEE = 0.33 +/- 0.12 cm2) and after (mean R = 0.92 +/- 0.05, SEE = 0.59 +/- 0.81 cm2) cardiopulmonary bypass. The slopes of these stroke area-stroke volume relations were quite reproducible from before to after cardiopulmonary bypass in the same patient but varied between individual patients. Transesophageal automated border detection has potential for on-line estimation of changes in stroke volume in selected patients.

Aged↗

Right ventricular/arterial coupling in the patient with left ventricular assistance.

BACKGROUND: Improvements are known to occur in right ventricular (RV) ejection fraction after the use of a left ventricular assist device (LVAD); less is known, however, about the mechanism of this improvement. The concept of ventricular/arterial coupling was applied to investigate whether systolic pump function or afterload reduction was the major contributing factor leading to the improvement in RV ejection fraction. METHODS AND RESULTS: Eight consecutive patients who underwent Novacor LVAD implantation as a bridge to transplantation were studied intraoperatively with transesophageal echocardiogram and a catheter-tip manometer to examine the RV end-systolic pressure-area relation (ESPAR) before and after LVAD implantation. Fractional area change (FAC) obtained by echocardiogram was used as an approximation of ejection fraction. End-systolic elastance (Ees), area axis intercept of ESPAR (A0), maximal area (Amax), and pulmonary effective arterial elastance (Ea) were obtained. RV FAC improved from 0.20 +/- 0.09 to 0.29 +/- 0.13 (p < 0.05). There was a decrease in Ea from 12.06 +/- 5.79 to 4.92 +/- 2.51 mm Hg/cm2 (p < 0.01), which indicated a reduction in RV afterload. A0 increased from -0.14 +/- 7.81 to 6.83 +/- 9.42 cm2 (p < 0.05), which implied impaired systolic pump function. There was no difference in Ees and Amax. CONCLUSIONS: The concept of ventricular/arterial coupling predicts that an increase of A0 (reduced RV systolic mechanics) decreases FAC, whereas a reduction in Ea improves FAC. The improvement in RV FAC (improved RV pump performance) may result from the effect of reduced Ea (afterload reduction) overwhelming the effect of increased A0. Afterload reduction is the most likely mechanism by which RV ejection fraction improves after LVAD implantation.

Adolescent↗

Automated monitoring of brainstem auditory evoked potentials in the operating room.

We monitored brainstem auditory evoked potentials in 112 patients undergoing retromastoid craniectomies for microvascular decompression. To provide information on latency changes as quickly as possible, we implemented a block averaging technique of data acquisition with automatic tracking of wave V latency, which is the most clinically useful information. A change in peak latency probably due to surgical manipulation was observed in 63% of the patients, and the change could be at least partially corrected by modification of surgical technique. Twenty percent of the 89 patients who underwent preoperative and postoperative audiometric testing showed a postoperative hearing decrement. Some patients had large intraoperative increases in latency without suffering postoperative hearing deficits, and some incurred hearing deficits even though the intraoperative latency increases were relatively small. However, patients whose brainstem auditory evoked potentials were lost during surgery, even temporarily, were likely to have postoperative hearing decrements. Patients who had deficits tended to have slightly greater increases in latency than patients without deficits, but the difference in the mean increases of the two groups was not statistically significant. Most of the deficits were small, and all resolved over time.

Computers↗

Sensory evoked potentials: a system for clinical testing and patient monitoring.

There is increasing interest in the use of averaged sensory evoked potentials for diagnostic testing and patient monitoring. This testing technique offers an opportunity to obtain information on function in the central nervous system and can be used in uncooperative and comatose patients. However, in the clinical situation background noise is often high, due for example to posturing by the patient, and even with extensive signal averaging it can be difficult to determine whether a response is present. This paper describes a data acquisition technique we have implemented for patient testing in the intensive care unit and the operating room to facilitate analysis of the responses. The averaging system delivers the stimulus in the middle of the data window, providing a pre-stimulus control interval from which to estimate residual background noise in the average. In addition, two averages are formed simultaneously to determine reproducibility of the response. This technique has been modified to provide a method of continuous monitoring that allows rapid detection of large changes in the response plus automatic tracking of selected response peak parameters.

Data Collection↗

Two-dimensional echocardiographic automated border detection accurately reflects changes in left ventricular volume.

The objective of this study was to determine the relationship of on-line measurements of left ventricular cavity area generated by echocardiographic automated border detection to true volume measured by an intraventricular balloon in an isovolumically contracting isolated canine heart preparation. Seven excised dog hearts had placement of an intraventricular balloon and were perfused in an ex vivo apparatus. Left ventricular area data from the midventricular short-axis plane and pressure data were recorded on a computer through a customized hardware and software interface with the ultrasound system. Left ventricular volumes were varied from 5 ml to maximal values (30 to 40 ml) at 1-milliliter increments. Three increasing and decreasing volume ramps were analyzed on each of seven hearts for a total of 1260 simultaneous measurements. Linear regression analysis correlated mean automated border detection area with absolute volume from each preparation. A predominantly linear relationship was observed with an average correlation of r = 0.97 (y = 0.16x-0.69, SEE = 0.31 cm2, p < 0.01). Left ventricular area measures for six of seven dogs varied little during isovolumic contraction (< 0.4 cm2) but did show a systematic cardiac cycle-related variability in one dog (28% change in area, maximum to minimum, over all volumes). In conclusion, the relationship between cross-sectional area and left ventricular volume was predominantly linear and varied little during isovolumic contractions in the normal canine left ventricle. Echocardiographic automated border detection appears to be a promising method to reflect changes in left ventricular volume.

Animals↗

Quantitation of right ventricular shape changes after left ventricular assist device implantation.

Complex effects of left (LV) and right ventricular (RV) interaction account for changes in RV function during LV assist device (LVAD) support. It has been hypothesized that changes in RV cross-sectional shape (RVS) may be a contributing factor in the development of RV dysfunction during LVAD support. To test the hypothesis that the RVS would become more circular as a result of septal shift during LVAD support, 13 patients were studied before and after LVAD implantation. The shape of the RV was quantified using a shape factor (SF) that was equal to (4 x pi x area)/P2, where P is the perimeter of RVS. The RV area and perimeter were measured from digitized images of the RV obtained by transesophageal echocardiography in patients before and after LVAD implantation. The group SF increased considerably after LVAD (SFpre = 0.78 +/- 0.12 versus SFpost = 0.88 +/- 0.07, p < 0.05). Patients were divided into three groups: 1) patients whose RV exhibited a low SF pre-LVAD that increased significantly, 2) those with a moderate SF pre-LVAD that increased slightly, and 3) those who had high pre-LVAD SF (< 0.90) that did not change. The decompression of the LV caused by LVAD implantation results in a shift of the septum from right to left, increasing SF. This increase is more pronounced in some patients. Quantitation of the degree of RV SF change may help predict the development of RV failure during LVAD support.

Adult↗

Differential regional function of the right ventricle during the use of a left ventricular assist device.

The use of a left ventricular assist device (LVAD) as a bridge to transplant is associated with a 52% incidence of RV failure requiring additional inotropic or mechanical support (RVAD). This study evaluated the differential performance of the RV free wall and septum to identify the need for additional RV support. Cross-sectional views of the RV were obtained immediately before, and 1 hr after, Novacor LVAS implantation in 12 consecutive patients using transesophageal echocardiography. Each image was divided into a free wall portion (FW) and a septal portion (SP) by grids drawn from the center of gravity of the end-diastolic endocardial outline to the junction between the FW and the SP. Percentage change between preimplant and postimplant for RV ejection fraction (RVEF), fractional area change for the FW (FAC-FW) and the SP (FAC-SP), and fractional shortening of the FW to SP distance (F-S) is reported for patients based upon the need for RV support: minimal (Group 1), maximal (Group 2). After LVAS implantation, patients showed a reduction in SP fractional area change. However, this reduction was most pronounced in Group 2. The degree of SP impairment may explain the mechanism of RV failure in patients on an LVAD.

Adolescent↗