Vancomycin sequestration during cardiopulmonary bypass surgery.

OBJECTIVE: The present study was designed to analyze vancomycin disposition in adult patients undergoing coronary bypass grafting during and following cardiopulmonary bypass (CPB). METHODS: Coronary bypass surgery was performed on 11 adults with a mean age (SD) of 62.9 (9.0) years old, who received a mean (SD) vancomycin prophylactic dose of 12.7 (1.0) mg/kg in a mean period of 41 (0.7) min. Using a two-compartment open model for pharmacokinetic analysis, the following parameters were obtained: alpha half-life, minutes (t(1/2alpha)); beta half-life, hours (t(1/2beta)); apparent volume of distribution, (V(d) l/kg); volume of the central compartment, (V(c) l/kg), constant between the "central to the peripheral" compartment, (k(12)); constant between the "peripheral to the central" compartment, (k(21)); total area under the concentration-time curve, (AUC mg/lxh) and a vancomycin clearance, (Cl(van) ml/min), respectively. RESULTS: The mean (SD) calculated pharmacokinetic parameters were: t(1/2alpha)17.6 (6) min, t(1/2beta) 8.4 (3.8) h, V(d) 0.803 (0.259) l/kg, V(c) 0.270 (0.162) l/kg, k(12) 0.03 (0.015), k(21) 0.012 (0.012), total AUC 10377.2 (3687.6) mg/lxh. The mean (SD) vancomycin clearance by the CPB machine was 9.51 (2.66) l/h, and the mean (SD) total vancomycin sequestrated by CPB was 331.7 (84) mg. A significant difference (6.3%; p = 0.001) was measured between the mean measured AUC during CPB (1088.1 +/- 253.9) and the same calculated parameter (1160.2 +/- 282). Five minutes after starting CPB, a decrease in vancomycin level was detected; this difference was found to be nearly 11% in absolute values. CONCLUSIONS: This confirmatory study demonstrated that the vancomycin blood concentrations obtained during the study allow recommending a safety prophylactic dose of 12mg/kg in adults who undergo open-heart surgery under CPB conditions. Sequestration of vancomycin by the oxygenator or/and tubing system of the CPB machine had occurred and had been measured in this study.

Aged↗

The Haemodynamic Instability Score (HIS) for assessment of cardiovascular reactivity in hypertensive and normotensive patients.

The normal response to postural challenge is characterised by maintenance of relatively stable blood pressure (BP) and heart rate (HR) after 30 sec to 30 min of head-up tilt. The objective of the present study was to determine the degree of instability of cardiovascular responses to postural challenge in normotensive and hypertensive subjects. In the initial phase of the study, two groups of age and sex-matched subjects were assessed: essential hypertension (n = 20) and healthy (n = 37). The BP and HR were recorded at 5-min intervals during the course of the 10-min supine-30-min head-up tilt test (HUTT). We categorised 'BP-change' as the difference between individual BP measurements during HUTT and the last recumbent BP value, divided by latter value. The average and standard deviation (SD) of the recorded BP changes were calculated, and BP changes were plotted along a time curve. A computerised image analyser then calculated the outline ratio (OR) and fractal dimension (FD) values for each of the curves. An identical process evaluated measurements for HR-changes. BP- and HR-changes were then converted into absolute numbers, and the average, SD, OR, and FD were calculated. A multivariate analysis was conducted, evaluating independent predictors of hypertension. Finally, an equation for the calculation of 'haemodynamic instability score' (HIS) was deduced and a cut-off between HIS of hypertensive and normotensive subjects was established. Independent predictors of the cardiovascular response to postural challenge of hypertensives (Group I) vs healthy (Group II) were: a.DIAST-FD, a.HR-AVG, a.HR-SD, a.HR-FD, DIAS-SD and HR-SD and HR-SD. Based on these five predictors, a linear discriminant score was computed and called the Haemodynamic Instability Score (HIS): HIS = 59.4 + (-16.6*a.DIAST-FD) + (-29.0*a.HR-AVG) + (-82.4*a.HR-SD) + (-30.1*a.HR-FD) + (-57.9*DIAS-SD) + (73.4*HR-SD) The HIS values in Group I (hypertensives) were: avg = 3.348, SD = 2.863, and 95% CI for mean = 2.008, 4.688. The HIS values in Group II (healthy) were: avg = -3.394, SD = 2.435, 95% CI for mean = -4.206, -2.582. Values of the HIS > -2.09 were generally observed in hypertensives (sensitivity 95%) and values < or = -2.09 were usually seen in the healthy (specificity 81.1%). The HIS was cross-validated in an additional group of hypertensive patients (n = 73). In the latter group, the HIS values were: avg = -0.456, SD = 4.403, 95% CI for mean = -1.506, 0.593 and 71.4% sensitivity at the proposed cut-off point. In conclusion, the HIS confers numerical expression to the degree of lability of BP and HR during postural challenge. Based on this score, a distinction between the cardiovascular reactivity of hypertensives vs normotensives is drawn. Possible applications of HIS are discussed.

Adult↗

Hemodynamic instability in chronic fatigue syndrome: indices and diagnostic significance.

OBJECTIVES: To evaluate the cardiovascular response to postural challenge in patients with chronic fatigue syndrome (CFS) and to determine whether the degree of instability of the cardiovascular response may aid in diagnosing CFS. METHODS: Patients with CFS (n = 25) and their age- and gender-matched healthy controls (n = 37), patients with fibromyalgia (n = 30), generalized anxiety disorder (n = 15), and essential hypertension (n = 20) were evaluated with the aid of a standardized tilt test. The blood pressure (BP) and heart rate (HR) were recorded during 10 minutes of recumbence and 30 minutes of head-up tilt. We designated BP changes as the differences between successive BP values and the last recumbent BP. The average and standard deviation (SD) were calculated. Time curves of BP differences were loaded into a computerized image analyzer, and their outline ratios and fractal dimensions were measured. HR changes were determined similarly. The average and SD of the parameters were calculated, and intergroup comparisons were performed. RESULTS: On multivariate analysis, the independent predictors of CFS patients versus healthy controls were the fractal dimension of absolute values of the systolic BP changes (SYST-FD.abs), the standard deviation of the current values of the systolic BP changes (SYST-SD.cur), and the standard deviation of the current values of the heart rate changes (HR-SD.cur). The following equation was deduced to calculate the hemodynamic instability score (HIS) in the individual patient: HIS = 64.3303 + (SYST-FD.abs x -68.0135) + (SYST-SD.cur x 111.3726) + (HR-SD.cur x 60.4164). The best cutoff differentiating CFS from the healthy controls was -0.98. HIS values >-0.98 were associated with CFS (sensitivity 97%, specificity 97%). The HIS differed significantly between CFS and other groups (P <.0001) except for generalized anxiety disorder. Group averages (SD) of HIS were CFS = +3.72 (5.02), healthy = -4.62 (2.26), fibromyalgia = -3.27 (2.63), hypertension = -5.53 (2.24), and generalized anxiety disorder = +1.08 (5.2). CONCLUSION: The HIS adds objective criteria confirming the diagnosis of CFS.

Adult↗

Cardiovascular response to upright tilt in fibromyalgia differs from that in chronic fatigue syndrome.

OBJECTIVE: To compare the cardiovascular response during postural challenge of patients with fibromyalgia (FM) to those with chronic fatigue syndrome (CFS). METHODS: Age and sex matched patients were studied, 38 with FM, 30 with CFS, and 37 healthy subjects. Blood pressure (BP) and heart rate (HR) were recorded during 10 min of recumbence and 30 min of head-up tilt. Differences between successive BP values and the last recumbent BP, their average, and standard deviation (SD) were calculated. Time curves of BP differences were analyzed by computer and their outline ratios (OR) and fractal dimensions (FD) were measured. HR differences were determined similarly. Based on the latter measurements, each subject's discriminant score (DS) was computed. RESULTS: For patients and controls average DS values were: FM: -3.68 (SD 2.7), CFS: 3.72 (SD 5.02), and healthy controls: -4.62 (SD 2.24). DS values differed significantly between FM and CFS (p < 0.0001). Subgroups of FM patients with and without fatigue had comparable DS values. CONCLUSION: The DS confers numerical expression to the cardiovascular response during postural challenge. DS values in FM were significantly different from DS in CFS, suggesting that homeostatic responses in FM and CFS are dissimilar. This observation challenges the hypothesis that FM and CFS share a common derangement of the stress-response system.

Adult↗

The use of technologies to decrease peri-operative allogenic blood transfusion: results of practice variation in Israel.

BACKGROUND: Concern about the side effects of allogeneic blood transfusion has led to increased interest in methods of minimizing peri-operative transfusion. Technologies to minimize allogeneic transfusion include drugs such as aprotinin, desmopressin, tranexamic acid and erythropoietin, and techniques such as acute normovolemic hemodilution, cell salvage and autologous pre-donation. OBJECTIVE: To survey the current use in Israel of these seven technologies to minimize allogeneic blood transfusion. METHODS: Our survey was conducted in 1996-97 in all hospitals in Israel with more than 50 beds and at least one of the following departments: cardiac or vascular surgery, orthopedics, or urology. All departments surveyed were asked: a) whether the technologies were currently being used or not, b) the degree of use, and c) the factors influencing their use and non-use. The survey was targeted at the heads of these departments. RESULTS: Pharmaceuticals to reduce allogeneic blood transfusion were used in a much higher proportion in cardiac surgery departments than in the other three departments. Pre-operative blood donation was used in few of the cardiac, urologic and vascular surgery departments compared to its moderate use in orthopedic departments. The use of acute normovolemic hemodilution was reported in a majority of the cardiac departments only. Moderate use of cell salvage was reported in all departments except urology where it was not used at all. CONCLUSION: There is considerable practice variation in the use of technologies to minimize exposure to peri-operative allogeneic blood transfusion in Israel.

Aprotinin↗

The esophageal tracheal combitube as a non-invasive alternative to endotracheal intubation. A review.

The esophageal tracheal combitube (ETC) is a supraglottic airway device that functions as an effective alternative to ventilation via mask and tracheal intubation and is therefore a valuable tool in difficult and emergency airway management. The Com-bitube has proven to be a valuable tool for securing the airways and providing adequate ventilation. Its advantages are that it is easy to insert quickly, it may be inserted blindly or with the aid of a laryngoscope, and it provides adequate ventilation and oxygenation in both esophageal and tracheal position. The combitube allows application of high ventilatory pressures and it minimises the risk of aspiration. Several guidelines including European Resuscitation Council, Ame-rican Heart Association, American Society of Anesthesiologists have included the combitube as a primary rescue device in cannot ventilate cannot intubate situations. It has been used in elective patients as well as in emergency situations in- and out-of-hospital. The combitube can be inserted with minimal movement of the cervical spine and is therefore indicated whenever cervical spine movement is anatomically restricted (e.g. rheumatoid arthritis) or should be functionally restricted (e.g. trauma). Since the combitube isolates the lungs from the esophagus it is especially useful in patients at risk for aspiration (e.g., caesarean section, morbid obesity). The combitube is available in two sizes: 37 F SA (Small Adult) and 41 F. Unfortunately, a pediatric size is not commercially available. Training in the use of the combitube under controlled conditions is prerequisite to being expert in an emergency situation. The combitube is another non-surgical airway in the armamentarium of the anaesthesiologist or emergency provider in case of foreseen or unforeseen difficult airways in patients who can neither be intubated or mask ventilated.

Equipment Design↗

Patient-controlled analgesia for conscious sedation during colonoscopy: a randomized controlled study.

BACKGROUND: The aim of this study was to assess whether patient-controlled anesthesia (PCA) can improve patient tolerance for colonoscopy. We compared baseline sedation and analgesia with baseline sedation and PCA. METHODS: Fifty-six consecutive patients were alternatively allocated to 1 of 2 groups: either to control group (n = 28) to receive standard sedation (meperidine and midazolam as baseline and additional doses of meperidine administered by the anesthesiologist) or to a PCA group (n = 28) to receive the same baseline premedication but additional analgesia with meperidine being self-administered. Cardiopulmonary parameters were recorded and tolerance for the examination was evaluated by a numeric rating scale, 0 meaning "no pain" and 10 meaning "maximal pain." RESULTS: Patients' mean pain score (on a scale of 0 to 10) was 4.85 +/- 3.74 for the PCA group and 5.30 +/- 3.53 (not significant) for the control group. Physicians' assessment of patient tolerance registered a lower numeric rating score than patients' assessment. The duration of the procedure was slightly longer in the PCA group. None of the patients experienced a decline in oxygen saturation below 90%; a decrease in expiratory carbon dioxide during the examination was noted in both groups of patients, particularly during the first minutes of the examination. Mean additional sedation per patient in the PCA group was slightly higher, but not significantly different. CONCLUSIONS: Our results suggest that patient-controlled analgesia during colonoscopy is as effective as standard sedation with respect to patient tolerance and safety of the examination.

Aged↗

The influence of preemptive spinal anesthesia on postoperative pain.

STUDY OBJECTIVE: To examine the influence of spinal anesthesia on postoperative pain and postoperative opioid requirements. DESIGN: Prospective randomized study. SETTING: Bnai-Zion Medical Center, Haifa, Israel-a government hospital. MEASUREMENTS AND MAIN RESULTS: 30 ASA physical status I and II unpremedicated women undergoing elective total abdominal hysterectomy were randomly allocated into two groups of 15 patients each using a sealed envelope technique. Patients in Group 1 were given a subarachnoid injection of 12 mg hyperbaric bupivacaine and after 10 minutes general anesthesia was induced. Patients in Group 2 received only general anesthesia. Anesthesia was induced with midazolam and maintained with oxygen, N2O, isoflurane, and pancuronium. No opioids were given intraoperatively. Postoperatively patient-controlled analgesia (PCA) with morphine was initiated in both groups (1 mg x mL(-1), bolus dose 1 mg, lockout interval 10 minutes, and background infusion 1 mg x mL(-1)) at patient first request for analgesic. Pain was assessed over 24 hours by cumulative morphine dose and visual analog score (VAS). Postoperative PCA morphine consumption at 2, 6, and 24 hours following patient first request for analgesic for Groups 1 and 2 were: 3.1 +/- 1 mg versus 7.2 +/- 3 mg (p = 0.04), 13.4 +/- 2 mg versus 17.2 +/- 4 mg (p = 0.03) and 35.9 +/- 8 mg versus 47.7 +/- 8 mg in Group 2 (p = 0.04). VAS scores at 4, 6, 12, and 24 hours postoperatively were not significantly different between the two groups. CONCLUSIONS: Preoperative neural blockade may reduce postoperative analgesic requirements.

Adult↗

In-field validation of automatic blood pressure measuring devices.

The method for rapid evaluation of automatic blood pressure (BP) measurement devices (READ) is based on numerous BP measurements at rest and during a standardised postural challenge in a small number of subjects with a wide range of BPs. The present study proposes additional parameters of the READ for in-field validation of automatic BP measurement devices. BP measurements were done in supine position for 10 min followed by head-up tilt for 30 min and again supine for 10 min. BPs were determined simultaneously by automatic (AU) and mercury sphygmomanometric (MS) measurements on the same arm. The BP differences DeltaBP:AU-MS were calculated. Three units of the Colin BP-8800 and the Datex-Engstrom Cardiocaptrade mark II were evaluated. Based on DeltaBP(AU-MS), the grade of accuracy, aberration patterns and correlates of accuracy were assessed for each unit. Per unit, an average of 121 measurements were done, every BP category being met in >/=20 MS measurements. In general, the AU systolic BP values were higher than MS systolic BP values (mean systolic DeltaBP = 1.26 +/- 17.1 mm Hg) and AU diastolic BP values were lower than MS diastolic BP values (mean diastolic DeltaBP = -12.31 +/- 7.8 mm Hg). All units classified into category D of the British Hypertension Society grading system and exhibited inconsistent aberration patterns, making design of correction formulas impractical. Inaccuracy of the instruments was independent on mode of measurement, posture, magnitude of the BP and heart rate, early or late measurements from beginning of the head-up tilt test, and prolonged use of the unit. The READ permitted to identify rapidly the degree of accuracy of automatic BP measuring devices. Identification of the aberration pattern of an instrument could be the basis for calculating equations for correction of the measured BP. Further studies will show which parameters of the READ may expose specific defects of the instruments. Journal of Human Hypertension (2000) 14, 37-42.

Adult↗

Accuracy of the OMRON M4 automatic blood pressure measuring device.

Despite widespread use of the automatic blood pressure (BP) measuring device OMRON M4, there is little formal validation on its accuracy. A study was conducted to assess the accuracy of the OMRON M4 compared with the true indirect BP measured by mercury sphygmomanometer (MS). A rapid method for the evaluation of automatic blood pressure measurement devices (READ) was applied for this study. The READ is based on numerous BP measurements at rest and during a standardised postural challenge in a small number of subjects who exhibit a wide range of BPs. Blood pressure measurements were done in supine position for 10 min followed by head-up tilt for 30 min and again supine for 10 min. The automatic device (AU) and the MS were connected to one arm-cuff by means of a T connector. A stethoscope with dual sets of ear-pieces was used for duplicate MS measurements (MS1 and MS2). The MS1, MS2 and AU measurements were taken simultaneously in a blinded manner. Three units of the automatic instrument were evaluated. An average of 111 measurements per unit were performed, every BP category being present in >/=15 MS measurements. The differences between MS1 and MS2 measurements (DeltaBP: MS1-MS2) were utilized to assess the consistency of true indirect BP and the differences between AU and MS measurements (DeltaBP:AU-MS2) were utilized to assess the accuracy of the AU. The following characteristics of the OMRON M4 were assessed: (1) grade of accuracy, (2) aberration pattern, (3) consistency of the aberration-pattern, and (4) correlation between levels of BP and DeltaBP: AU-MS. For MS paired readings, 92-100% of systolic and 99-100% of diastolic readings fell within 5 mm Hg difference range, that is consistent with a British Hypertension Society grade A of both. For AU compared to MS2, 29-64% of systolic and 73-94% of diastolic readings fell within 5 mm Hg and 49-86% of systolic and 86-99% of diastolic readings fell within 10 mm Hg and the devices qualified C, D and C, respectively. All devices exhibited irregular and inconsistent aberration patterns, making the design of correction formulas impractical. In conclusion, the OMRON M4 device did not meet the requirements of the British Hypertension Society and, therefore, cannot be recommended for clinical use.

Adult↗

The capnography head-up tilt test for evaluation of chronic fatigue syndrome.

OBJECTIVES: To compare the hemodynamic and ventilatory responses to autonomic challenge evoked by upright tilt table testing in patients with chronic fatigue syndrome (CFS) to healthy individuals. METHODS: Thirty-two consecutive patients with CFS and 32 healthy volunteers were evaluated with the aid of the recently introduced capnography head-up tilt test (CHUTT). The main outcome measures were values of blood pressure (BP), heart rate (HR), respiratory rate (RR), and end-tidal pressure of co2 (ETPco2) recorded during recumbence and tilt. In addition, the end points of vasodepressor and cardioinhibitory reactions, hyperventilation (defined by ETPco2 <25 mm Hg) and the postural tachycardia syndrome, were recorded. RESULTS: The BP, HR, RR, and ETPco2 recorded during recumbence were similar in both groups. During tilt, patients with CFS developed significantly lower systolic BP, diastolic BP, and ETPco2, and a significant rise in HR and RR (P<.01). In CFS patients, the postural tachycardia syndrome occurred in 44%, vasodepressor reaction in 41%, cardioinhibitory reaction in 13%, and hyperventilation in 31% of cases. One or more end points of the CHUTT were reached in 78% of patients with CFS but in none of the controls (P<.0001). CONCLUSIONS: In most patients with CFS, a spectrum of abnormal homeostatic reactions is diagnosed with the aid of the CHUTT. Data provided by the CHUTT may reinforce the clinical diagnosis by adding objective and unbiased criteria to the subjective assessment of CFS.

Adult↗

Association between epidural analgesia and intrapartum fever.

The objective of this paper is to determine whether or not epidural analgesia is an independent risk factor for intrapartum fever. Maternal temperature was measured every 4 h during labor to 1004 consecutive women in term labor. Women with fever or on antibiotics were excluded. Epidural analgesia was administered upon patients' request. Of the 406 (40%) women who received epidural analgesia, 11.8% (n = 48) developed a fever > or = 37.8 degrees C during labor compared with only 0.2% (n = 1) of women not receiving epidural analgesia. Women who received epidural analgesia were more likely to have one or more risk factors for intrapartum infection. Their labor and ruptured membranes were longer, they were more likely to have internal monitoring and have more vaginal examinations. Compared with women who received epidural analgesia and did not develop intrapartum fever, women that did develop fever had longer epidurals and more risk factors for infection. However, in a logistic regression analysis with fever as dependent variable, only the duration of epidural was significantly associated with the occurrence of fever. The rate of fever increased with longer labors, from 5% with labor < 3 h to 28% with labor > 6 h. In 90% of women the fever resolved within a few hours after delivery. Sepsis evaluation was negative in all of the newborns to mother who had intrapartum fever. Our data support a noninfectious etiology for intrapartum fever in the vast majority of our patients. However, infection must be ruled out before a decision is made to withhold antibiotic therapy.

Adult↗

Inferior turbinectomy versus submucosal diathermy for inferior turbinate hypertrophy.

In order to compare and evaluate bilateral inferior turbinectomy (BIT) and submucosal diathermy (SMD), we retrospectively examined these two well-known techniques for treatment of nasal obstruction due to bilateral congestion of the inferior turbinates. One hundred patients with bilateral nasal obstruction were divided into 4 groups according to their nasal airflow patency. Forty-nine patients underwent BIT, and 51 patients underwent SMD. All 100 patients were followed for 2 months after surgery. Patients with difficult postoperative courses were followed up to 1 year after surgery, in order to decide on the necessity of operative revision. Postoperative improvement in nasal breathing after BIT was reported for 96% of patients 2 weeks after surgery, and for 88% 2 months after surgery. Only 1 BIT patient had to undergo revision operation. Diathermy showed good results in 78% of cases 2 weeks after surgery. The efficacy of the procedure was reduced to 76% 2 months after surgery. Twenty percent of SMD patients were advised to undergo operative revision. Postoperative bleeding occurred in 20% of BIT patients and in only 4% of SMD patients. We found that the extent of postoperative improvement does not depend on preoperative conditions; therefore, it is impossible to predict the extent of postoperative improvement on the basis of the results of preoperative assessment. Both procedures can be performed under local anesthesia, are relatively safe and effective, and do not need expensive instrumentation that may not be available in many medical centers.

Adolescent↗

Acute renal failure following laparoscopic cholecystectomy: a case report.

The carbon dioxide (CO2) pneumoperitoneum of laparoscopic surgery is a complex physiologic event associated with neuroendocrine, respiratory, cardiovascular, and renal disturbances, as well as compromised organ blood flow. A case is presented of a 67-year-old man with a history of chronic renal failure, renal tubular acidosis, and hypertension, who underwent an uneventful elective laparoscopic cholecystectomy that included 75 minutes of CO2 pneumoperitoneum of 15 mmHg pressure. Postoperatively, the patient developed acute renal failure from which he recovered within 2 weeks. In the absence of other evident precipitating factors, we suspect that the CO2 pneumoperitoneum played a causal role in the development of his acute renal failure. The potential seriousness of the physiologic insult of conventional CO2 pneumoperitoneum suggests that "minimal access" surgery is not necessarily "minimally invasive."

Acute Kidney Injury↗

Rapid estimation of the accuracy of automatic blood pressure measuring devices (READ).

We propose a rapid method for the evaluation of automatic blood pressure measurement devices (READ) in response to the claim to simplify the validation of those devices. The READ is based on numerous blood pressure (BP) measurements at rest and during a standardised postural challenge in a small number of subjects who exhibit a wide range of BPs. Automatic (AU) and mercury sphygmomanometric (MS) brachial BP were measured simultaneously in a blinded manner. An average of 30 measurements per patient were done in 10-min while in a supine position, followed by 30 min in head-up tilt and again supine for 10 min. Two Collin-8800 automated oscillometric devices were tested with the aid of the READ in 15 adults. The consistency of the MS standard was demonstrated by duplicate MS measurements showing minimal inter-observer differences consistent with class A of the British Hypertension Society (BHS) grading system. AU-to-MS differences of 447 measurements were mean systolic deltaBP = 1.1 +/- 11.4 mm Hg and mean diastolic deltaBP = -13.36 +/- 8.9 mm Hg, classifying into category D of the BHS. Both tested instruments, each subject, each phase of the tilt test (supine I, tilt, supine II) and each mode of measurement (at 5-min intervals or continuously) equally qualified as 'D'. We conclude that the READ permitted us to identify quickly and at low expense a grossly inaccurate automatic BP measuring device. Further studies will show whether the READ can be efficient as a pre-validation test, post-validation test, and for assessment of ambulatory BP measuring devices.

Adult↗

[Continuous quality improvement in anesthesia].

Slow continuous quality improvement (SCQI) in anesthesia is a process that allows identification of problems and their causes. Implementing measures to correct them and continuous monitoring to ensure that the problems have been eliminated are necessary. The basic assumption of CQI is that the employees of an organization are competent and working to the best of their abilities. If problems occur they are the consequences of inadequacies in the process rather that in the individual. The CQI program is a dynamic but gradual system that invokes a slower rate of response in comparison with other quality methods, like quality assurance. Spectacular results following a system change are not to be expected an the ideal is slow and continuous improvement. A SCQI program was adapted by our department in May 1994, according to the recommendations of the American Society of Anesthesiologists. Problem identification was based on 65 clinical indicators, reflecting negative events related to anesthesia. Data were collected using a specially designed computer database. 4 events were identified as crossing previously established thresholds (hypertension, hypotension, hypoxia and inadequate nerve block). Statistical process control was used to establish stability of the system and whether negative events were influenced only by the common causes. The causes responsible for these negative events were identified using specific SCQI tools, such as control-charts, cause-effect diagrams and Pareto diagrams. Hypertension and inadequate nerve block were successfully managed. The implementation of corrective measures for the other events that cross the threshold is still in evolution. This program requires considerable dedication on the part of the staff, and it is hoped that it will improve our clinical performance.

Anesthesia↗