PubMed HealthSearch

Biomedical subjects

L Gepstein

Publications and source records attributed to L Gepstein.

11 recordsLinked to original sources

Atrial linear ablations in pigs. Chronic effects on atrial electrophysiology and pathology.

BACKGROUND: Generation of long and continuous linear ablations is required in a growing number of atrial arrhythmias. However, deployment and assessment of these lesions may be difficult, and there are few data regarding their short- and long-term effects on atrial electrophysiology and pathology. METHODS AND RESULTS: A nonfluoroscopic mapping and navigation technique was used to generate 3-dimensional (3D) electroanatomic maps of the right atrium in 8 pigs. The catheter was then used to deliver sequential radiofrequency (RF) applications (power output gradually increased until 80% reduction in the amplitude of the unipolar electrogram) to generate a continuous lesion between the superior and inferior venae cavae. The animals were remapped 4 weeks after ablation during septal pacing. Lesion continuity was confirmed in all cases by the following criteria: (1) activation maps indicating conduction block [significant disparities in activation times (52.0+/-16.0 ms) and opposite orientation of the activation wave front on opposing sides of the lesion], (2) evidence of double potentials (interspike time difference of 52.3+/-17.1 ms), and (3) low peak-to-peak amplitude of the bipolar electrograms (0.7+/-0.6 mV) along the lesion. At autopsy, all lesions were continuous and transmural, averaged 50.5+/-6.7 mm, and were characterized histologically by transmural fibrosis throughout the length of the lesion. CONCLUSIONS: Long linear atrial ablation, created by sequential RF applications (using unipolar amplitude attenuation as the end point for energy delivery), results in long-term continuous and transmural lesions. Lesion continuity is associated with evidence of conduction block in the 3D activation maps and the presence of double potentials and low electrogram amplitude along the lesion.

Animals

Electromechanical characterization of chronic myocardial infarction in the canine coronary occlusion model.

BACKGROUND: Defining the presence, extent, and nature of the dysfunctional myocardial tissue remains a cornerstone in diagnostic cardiology. A nonfluoroscopic, catheter-based mapping technique that can spatially associate endocardial mechanical and electrical data was used to quantify electromechanical changes in the canine chronic infarction model. METHODS AND RESULTS: We mapped the left ventricular (LV) electromechanical regional properties in 11 dogs with chronic infarction (4 weeks after LAD ligation) and 6 controls. By sampling the location of a special catheter throughout the cardiac cycle at multiple endocardial sites and simultaneously recording local electrograms from the catheter tip, the dynamic 3-dimensional electromechanical map of the LV was reconstructed. Average endocardial local shortening (LS, measured at end systole and normalized to end diastole) and intracardiac bipolar electrogram amplitude were quantified at 13 LV regions. Endocardial LS was significantly lower at the infarcted area (1.2+/-0.9% [mean+/-SEM], P<0.01) compared with the noninfarcted regions (7.2+/-1.1% to 13. 5+/-1.5%) and with the same area in controls (15.5+/-1.2%, P<0.01). Average bipolar amplitude was also significantly lower at the infarcted zone (2.3+/-0.2 mV, P<0.01) compared with the same region in controls (10.3+/-1.3 mV) and with the noninfarcted regions (4. 0+/-0.7 to 10.2+/-1.5 mV, P<0.01) in the infarcted group. In addition, the electrical maps could accurately delineate both the location and extent of the infarct, as demonstrated by the high correlation with pathology (Pearson's correlation coefficient=0.90) and by the precise identification of the infarct border. CONCLUSIONS: Chronic myocardial infarcted tissue can be characterized and quantified by abnormal regional mechanical and electrical functions. The unique ability to assess the regional ventricular electromechanical properties in various myocardial disease states may become a powerful tool in both clinical and research cardiology.

Animals

Preliminary animal and clinical experiences using an electromechanical endocardial mapping procedure to distinguish infarcted from healthy myocardium.

BACKGROUND: A catheter-based left ventricular (LV) endocardial mapping procedure using electromagnetic field energy for positioning of the catheter tip was designed to acquire simultaneous measurements of endocardial voltage potentials and myocardial contractility. We investigated such a mapping system to distinguish between infarcted and normal myocardium in an animal infarction model and in patients with coronary artery disease. METHODS AND RESULTS: Measurements of LV endocardial unipolar (UP) and bipolar (BP) voltages and local endocardial shortening were derived from dogs at baseline (n=12), at 24 hours (n=6), and at 3 weeks (n=6) after occlusion of the left anterior descending coronary artery. Also, 12 patients with prior myocardial infarction (MI) and 12 control patients underwent the LV endocardial mapping study for assessment of electromechanical function in infarcted versus healthy myocardial regions. In the canine model, a significant decrease in voltage potentials was noted in the MI zone at 24 hours (UP, 42. 8+/-9.6 to 29.1+/-12.2 mV, P=0.007; BP, 11.6+/-2.3 to 4.9+/-1.2 mV, P<0.0001) and at 3 weeks (UP, 41.0+/-8.9 to 13.9+/-3.9 mV, P<0.0001; BP, 11.2+/-2.8 to 2.4+/-0.4 mV, P<0.0001). No change in voltage was noted in zones remote from MI. In patients with prior MI, the average voltage was 7.2+/-2.7 mV (UP)/1.4+/-0.7 mV (BP) in MI regions, 17.8+/-4.6 mV (UP)/4.5+/-1.1 mV (BP) in healthy zones remote from MI, and 19.7+/-4.4 mV (UP)/5.8+/-1.0 mV (BP) in control patients without prior MI (P<0.001 for MI values versus remote zones or control patients). In the canine model and patients, local endocardial shortening was significantly impaired in MI zones compared with controls. CONCLUSIONS: These preliminary data suggest that infarcted myocardium could be accurately diagnosed and distinguished from healthy myocardium by a reduction in both electrical voltage and mechanical activity. Such a diagnostic electromechanical mapping study might be clinically useful for accurate assessment of myocardial function and viability.

Animals

Electroanatomical mapping of the heart: basic concepts and implications for the treatment of cardiac arrhythmias.

The CARTO electroanatomical mapping system represents a paradigm shift in the ability to map the three-dimensional anatomy of the heart and determine the cardiac electrical activity at any given mapped point. The system associates anatomical structure and electrophysiological data and displays the combined information in an easily readable, visual fashion. The system consists of a roving mapping catheter with small magnetic sensors in the tip, a fixed sensor that acts as a reference point, a low magnetic field generating pad, and a data acquisition and display system. When the roving catheter is moved in three-dimensional space, its location in relation to the fixed sensor is monitored by the system, with a resolution of < 1 mm. By gating the acquisition of points in space to the cardiac electrical activity, points that represent both location and electrical activity at that location can be acquired and displayed on a computer screen. After acquiring a number of points, a three-dimensional representation is constructed, and may be displayed from any viewing projection. Clinical applications of the system include defining the mechanisms of arrhythmias, designing ablation strategies, guiding ablations, and improving the safety of mapping and ablation procedures by allowing localization of critical cardiac structures such as the atrioventricular node and His bundle. The system holds the potential to both further our understanding of arrhythmias and increase the safety, efficacy, and efficiency of catheter ablation.

Arrhythmias, Cardiac

Activation-repolarization coupling in the normal swine endocardium.

BACKGROUND: While abnormalities of activation and repolarization play an important role in arrhythmogenesis, little information is available on the interaction between their spatial dispersions in the heart. This study examined the effects of activation spread on the spatial distribution of the repolarization properties during different depolarization patterns. METHODS AND RESULTS: Left ventricular (LV) endocardial activation and repolarization patterns were mapped in 13 healthy pigs. LV local activation, repolarization, and activation-recovery interval (ARI) times were determined from the intracardiac unipolar electrograms, color-coded, and superimposed on a three-dimensional anatomic map of the ventricle generated with a nonfluoroscopic mapping system. ARI values correlated with the duration of monophasic activation potential recorded from onset of activation to time of 90% repolarization (r=.97, P<.01). Activation time range of the left ventricle was 42+/-5 ms (mean+/-SEM) during sinus rhythm and 54+/-5 ms during right ventricular septal pacing. ARI inversely correlated with the corresponding activation times during both sinus (r2=.76+/-.03) and paced (r2=.77+/-.02) rhythms. The longest ARIs were located at the sites of earliest activation and shortest at the latest activation areas, with gradual shortening between them. CONCLUSIONS: The spatial distribution of repolarization is dependent on the activation pattern. Repolarization dispersion in the healthy swine heart is relatively small as the result of tight coupling of the action potential duration to the activation process, assigning longer ARIs to sites activated earlier. This coupling reduces global and regional dispersion of repolarization and may serve as an important antiarrhythmic mechanism present in normal myocardium.

Animals

Hemodynamic evaluation of the heart with a nonfluoroscopic electromechanical mapping technique.

BACKGROUND: Clinical cardiac volumetric measurement techniques are essential for assessing cardiac performance but produce significant inaccuracies in extrapolation of the volume of a three-dimensional (3D) object from two-dimensional images and lack the ability to associate cardiac electrical and mechanical activities. In this study, we tested the accuracy of cardiac volumetric measurements using a new catheter-based system. METHODS AND RESULTS: The system uses magnetic technology to accurately locate a special catheter at a frequency of 125 Hz and is currently used in the field of electrophysiology, in which activation maps are superimposed on the 3D geometry of the cardiac chamber. The mapping procedure is based on sequentially acquiring the location of the tip and local electrogram while in contact with the endocardium. The 3D geometry of the chamber is reconstructed in real time, and its volume could be calculated at every time step (8 ms). The volumetric measurements of the system were found to be highly accurate for simple phantoms (mean+/-SEM deviation, 2.3+/-1.1%), left ventricular casts (9.6+/-1.3%), and a dynamic test jig. In addition, left ventricular volumes of 12 swine were measured. Intraobserver and interobserver variabilities were found to be minimal (ejection fraction, 6.5+/-1.9% and 7.1+/-2.0%; stroke volume, 4.5+/-1.0% and 11.3+/-2.4%). Comparison with the thermodilution method for measuring stroke volume showed an average deviation of 8.1+/-2.2%. Typical pressure-volume loops were also obtained. CONCLUSIONS: The new mapping image provides, for the first time, simultaneous information regarding cardiac mechanics, hemodynamics, and electrical properties. Furthermore, all this information is achieved without the use of fluoroscopy, contrast medium, or complicated image processing.

Animals

Guidance of radiofrequency endocardial ablation with real-time three-dimensional magnetic navigation system.

BACKGROUND: Ablation therapy for certain arrhythmias requires the formation of complex lesions based on electrical and anatomic mapping. We tested the accuracy and reproducibility of a nonfluoroscopic mapping and navigation (NFM) system to guide delivery of radiofrequency (RF) energy in the right atrium (RA) of swine. METHODS AND RESULTS: The NFM system uses an ultralow magnetic field to measure the real-time three-dimensional (3D) location of the tip of the locatable catheter. While in stable contact with the endocardium, between 30 and 40 consecutive tip locations were sampled and used for the 3D reconstruction of the RA geometry. The location of the catheter tip was presented in real time, superimposed over the RA geometry. We selected a point on the 3D reconstruction and delivered RF energy to that site via the tip of the locatable catheter. The catheter was then completely withdrawn and renavigated twice to the same point, at which RF energy was delivered again. At autopsy, the distance between the centers of the three ablation points (mean+/-SEM) was 2.3+/-0.5 mm (n=27). Similarly, we used the NFM system to guide the generation of linear lesions. The measured length of the linear lesions on the NFM 3D view was close to the actual lesion length measured at autopsy (correlation coefficient, .96; P=.002; n=6). Furthermore, the location, shape, and continuity of the linear lesions corresponded to the autopsy findings. CONCLUSIONS: We conclude that the NFM system can guide the application of RF energy without the use of fluoroscopy in a highly accurate and reproducible manner.

Animals

A novel method for nonfluoroscopic catheter-based electroanatomical mapping of the heart. In vitro and in vivo accuracy results.

BACKGROUND: Cardiac mapping is essential for understanding the mechanisms of arrhythmias and for directing curative procedures. A major limitation of the current methods is the inability to accurately relate local electrograms to their spatial orientation. The objective of this study was to present and test the accuracy of a new method for nonfluoroscopic, catheter-based, endocardial mapping. METHODS AND RESULTS: The method is based on using a new locatable catheter connected to an endocardial mapping and navigating system. The system uses magnetic technology to accurately determine the location and orientation of the catheter and simultaneously records the local electrogram from its tip. By sampling a plurality of endocardial sites, the system reconstructs the three-dimensional geometry of the chamber, with the electrophysiological information color-coded and superimposed on the anatomy. The accuracy of the system was tested in both in vitro and in vivo studies and was found to be highly reproducible (SD, 0.16 +/- 0.02 [mean +/- SEM] and 0.74 +/- 0.13 mm) and accurate (mean errors, 0.42 +/- 0.05 and 0.73 +/- 0.03 mm). In further studies, electroanatomical mapping of the cardiac chambers was performed in 34 pigs. Both the geometry and activation sequence were repeatable in all pigs. CONCLUSIONS: The new mapping method is highly accurate and reproducible. The ability to combine electrophysiological and spatial information provides a unique tool for both research and clinical electrophysiology. Consequently, the main shortcomings of conventional mapping-namely, prolonged x-ray exposure, low spatial resolution, and the inability to accurately navigate to a predefined site-can all be overcome with this new method.

Animals

3D cardiac imaging of electromechanical coupling.

A novel method for three dimensional (3D) electromechanical mapping of the heart is presented. The new method is based on utilizing special magnetically locatable catheters connected to a mapping and navigation system. The 3D electromechanical map of the chamber is reconstructed by sampling the location of the catheter tip throughout the cardiac cycle at a plurality of endocardial sites together with their local electrograms. The ability to spatially combine electrical and mechanical information may provide a useful tool for both research and clinical cardiology.

Animals

[Ischemic hepatitis].

In ischemic hepatitis, which is not rare, there is a marked but transient increase in serum aminotransferase activity to at least 20 times the upper limit of normal, without any other cause for hepatic necrosis. It is generally preceded by an acute cardiac complication, usually pulmonary edema or a tachyarrhythmia, causing decrease in cardiac output, or may follow acute respiratory failure. The typical histological lesion is centrilobular hepatic necrosis. We present 2 cases of ischemic hepatitis due to hypotension following rapid atrial fibrillation, sepsis and acute respiratory failure, highlighting the different etiologies, laboratories results, and the relative benign course, described in the literature. The patients were a woman aged 80 and a man aged 76. Awareness of the place of this disorder in the differential diagnosis of acute hepatitis may save needless, dangerous investigations.

Aged