PubMed Health⌕ Search

Biomedical subjects

L H Braak

Publications and source records attributed to L H Braak.

3 recordsLinked to original sources

Analysis of stresses in two-dimensional models of normal and neuropathic feet.

A two-dimensional model of the normal foot skeleton, which includes cartilages and ligaments, is used in this analysis of stresses during three quasi-static walking phases: heel-strike, mid-stance and push-off. It is found that in all the walking phases the maximum values of principal stresses occur in the dorsal anterior region of the talus, whereas the highest stress occurs in the push-off phase. The model is used for the simulation of muscle paralysis and its effect on the distribution of principal stresses. Subsequently, the model is used to analyse stresses in the deformed feet of three leprosy patients with complete paralysis of certain muscles. The results demonstrate that both the shape of the foot and the type of muscle paralysis contribute to the development of high stresses in different regions of the foot. These high stresses in regions with reduced mechanical strength could be one of the important factors in the process of tarsal disintegration in leprosy.

Foot↗

A finite element analysis of the push-out test: influence of test conditions.

The commonly used method for quantitative evaluation of the strength of a bone-implant interface is the push-out test. In order to give an impulse to standardization and to gain more insight in the biomechanics of the push-out test, a finite element analysis of this test was performed. This study focused on the influence of test conditions on the push-out results. The influence of the following four parameters on the interface stress distribution was tested: (a) clearance of the hole in the support jig, (b) Young's modulus of the implant; (c) cortical thickness; and (d) implant diameter. The distance between the implant and the support jig turned out to be very critical for the occurrence of peak stresses in the interface. Variations of the Young's modulus of the implants resulted in a wide range of interface shear stresses. Variation of the cortical thickness showed a reciprocal relationship between cortical thickness and interface shear stress. However, the interface stress distribution remained uniform under the specific test circumstances. These findings also hold for variations in implant diameter. The present investigation shows that the clearance of the hole in the support jig, and the Young's modulus of the implant are parameters which most strongly influence the interface stress distribution. The clearance of the hole in the support jig is the most critical parameter, but also the parameter that can be controlled most easily. Lack of standardization with regard to these parameters can lead to uninterpretable test results. It is recommended that the clearance of the hole in the support jig is at least 0.7 mm and that push-out results are only compared with each other when materials with similar Young's modulus are concerned.

Animals↗

Stress-absorbing elements in dental implants.

By means of finite element analysis, calculations, were made of the stress-distribution in bone around implants with and without stress-absorbing elements. A freestanding implant and an implant, it was concluded the variation in the E-modulus of the stress-absorbing element had no effect on the stresses in bone. Changing the shape of the stress-absorbing element had little effect on the stresses in cortical bone. For the implant connected with a natural tooth, it was concluded that a more uniform stress was obtained around the implant with a low E-modulus of the stress-absorbing element. It was also concluded that the bone surrounding the natural tooth showed a decrease in the height of the peak stresses.

Computer Simulation↗