PubMed Health⌕ Search

Biomedical subjects

L H Brown

Publications and source records attributed to L H Brown.

At least 19 recordsLinked to original sources

The Autosow raised miniature swine as a model for assessing the effects of dietary soy trypsin inhibitor.

Toxicological effects of dietary soy trypsin inhibitor (TI) were assessed in male miniature swine, a model chosen for its similarities to human digestive physiology and anatomy. The TI preparation was extracted from defatted raw soy flour. From 1 through 5 weeks of age, piglets were automatically fed either a TI liquid diet [Autosow TI group (ASTI)] or a control liquid diet [Autosow control group (ASC)]. From 6 to 39 weeks of age, these animals received either swine chow and TI or swine chow and control article. The TI diets were formulated to contain a TI activity of approximately 500 mg TI/100 g dry matter. A sow control (SC) group suckled from birth to 6 weeks of age and then fed as the ASC group with swine chow plus control article from 6 to 39 weeks of age. The SC piglets grew faster than ASC piglets during postnatal weeks 1 and 2; however, the ASC piglets were significantly heavier than the SC piglets (P=0.001) at 6 weeks of age. Compared with the ASC group, TI caused a moderate decrease in feed consumption and a moderate but reversible decrease in growth from 2 to 5 weeks of age, but not thereafter. Some control and TI-fed Autosow-reared piglets had loose stools until 6 weeks of age; the effect was significantly greater in the TI-fed group. Otherwise, all swine were active and had normal appearance and behavior.

Administration, Oral↗

Pathological evaluation, clinical chemistry and plasma cholecystokinin in neonatal and young miniature swine fed soy trypsin inhibitor from 1 to 39 weeks of age.

The potential toxicity of dietary soy trypsin inhibitor (TI) was evaluated in neonatal miniature swine. From 1 to 6 weeks of age, two groups of male piglets were artificially reared in an Autosow and automatically fed either TI or control liquid diet. From 6 to 39 weeks of age, these two groups were fed either TI or control chow diet. A third group, sow control (SC), suckled from birth to 6 weeks of age, were also weaned to control chow from 6 to 39 weeks of age. Clinical chemistry and plasma cholecystokinin (CCK) determined at 6, 18, 30 and 39 weeks of age, and serum amylase activity with gross and histopathological analyses of major organs at 6 and 39 weeks of age are reported. TI had no effect on plasma CCK, serum amylase activity, or numerous clinical chemistry values. TI-fed piglets had a larger relative liver weight at 6 weeks of age. Relative pancreas weight decreased with age but was not affected by TI. Gross and histopathological analyses of major organs, except the spleen, were within normal limits. Increased incidence of extramedullary hematopoiesis was noted in the spleen of the TI group at 6 but not at 39 weeks of age. There was no consistent pattern in immunohistochemical foci for secretin, gastrin releasing polypeptide or CCK, and no change in DNA, RNA, mitotic index or nuclear density of pancreatic cells. At 6 weeks of age, TI increased pancreatic protein and amylase activity but not trypsin or chymotrypsin activity. None of the effects suggested that this dose of TI was toxic to either the neonatal or sexually mature miniature male swine.

Administration, Oral↗

Are barrier creams actually effective?

This article reviews the current information surrounding the efficacy of barrier creams as a protective measure against contact dermatitis. The principles of the proposed effects of barrier creams on the skin and the experimental and clinical data regarding their efficacy in the prevention of irritant and allergic contact dermatitis are discussed.

Animals↗

The effect of road improvements on motor vehicle crash injury and mortality in a developing country.

The developing island-nation of Grenada undertook a major road improvement project between 1995 and 1998. In order to determine the effect of those improvements on crash injury and mortality, we reviewed the number of crash-related injuries and deaths for the years 1994 and 1999. After the road improvements, the proportion of crashes that resulted in injury decreased from 22% to 15%. The raw number of crashes (818 vs. 1233), deaths (4 vs. 12) and deaths per 100,000 population (4.1 vs. 11.9) increased, but the proportion of crashes that resulted in death (0.5% vs. 0.7%) remained effectively unchanged.

Accidents, Traffic↗

A comparison of demand-valve and bag-valve ventilations in a swine pneumothorax model.

OBJECTIVE: Two means of delivering artificial ventilation readily available to out-of-hospital personnel are the bag-valve (BV) and the O2-powered demand-valve (OPDV). However, use of the OPDV has been limited because of concerns that it may worsen an underlying pneumothorax. This study compared the changes in size of pneumothorax in swine ventilated with the 2 devices. METHODS: Three swine were anesthetized, intubated, and instrumented with a femoral arterial line and a pediatric Swan-Ganz catheter. A chest tube was placed, the chest was opened, and the lung parenchyma was visualized. The lung was disrupted by a single stab with a #10 scalpel; the chest was then sealed; and a pneumothorax was created by injecting 30 mL of air through the chest tube. The animals were ventilated by 12 emergency medical technicians using either BV or OPDV. After 10 minutes of ventilation, the pneumothorax volume was measured. RESULTS: When comparing final pneumothorax volumes after 10 minutes of ventilation with the 2 devices, there was no significant difference (mean +/- SD = 40.8 +/- 28.2 mL vs 52.3 +/- 23.1 mL, p = 0.286). CONCLUSION: There is no difference in final pneumothorax volumes after OPDV or BV ventilation.

Animals↗

Can quantitative capnometry differentiate between cardiac and obstructive causes of respiratory distress?

STUDY OBJECTIVE: To determine whether quantitative measurement of end-tidal carbon dioxide (ETCO2) can differentiate between cardiac and obstructive causes of respiratory distress. DESIGN: Prospective observational study. SETTING: Emergency department (ED) of a tertiary care hospital. PATIENTS: Adult patients who presented to the ED with moderate-to-severe dyspnea. Patients were excluded if they were unable to cooperate with the performance of peak expiratory flow rate (PEFR) or ETCO2 tests, were younger than 18 years of age, or had received prehospital intervention for their respiratory distress. INTERVENTIONS: Physicians obtained an ETCO2 level and PEFR prior to ED pharmacologic intervention. A hand-held capnometer with digital read-out was used to obtain the ETCO2 level. The patient's age, sex, initial vital signs, breath sounds and medication history, the presence or absence of diaphoresis and/or orthopnea, the duration of symptoms, the chest radiograph interpretation, and final diagnosis were also recorded. MEASUREMENTS AND RESULTS: Forty-two patients were eligible for inclusion in the analysis. The mean ETCO2 level was 31.1+/-9.4 mm Hg; the mean PEFR was 161.3+/-53.1 L/min. The ETCO2 levels for pulmonary edema/congestive heart failure (CHF) patients differed significantly from those of asthma/COPD patients (27.1+/-7.8 mm Hg vs 33.4+/-9.6 mm Hg; p=0.0375). However, no single ETCO2 level was found to be a reliable predictor of diagnosis. CONCLUSION: ETCO2 levels for pulmonary edema/CHF patients differ significantly from those of asthma/COPD patients. However, no single ETCO2 level reliably differentiates between the two disease processes.

Adult↗

Assessment of breath sounds during ambulance transport.

STUDY OBJECTIVE: To determine whether the environment of a moving ambulance affects the ability of our-of-hospital care providers to auscultate breath sounds. METHODS: Out-of-hospital care providers assessed breath sounds with a previously described breath-sounds model in a quiet environment (control) and in a moving ambulance. The setting was a nonurban emergency medical services system and an interhospital transport agency based at a 600-plus-bed tertiary care center. The participants were physicians, transport nurses, and advanced life support EMS providers routinely involved in the emergency out-of-hospital treatment and transportation of the ill and injured. The accuracy with which participants identified the presence or absence of breath sounds in the two environments was compared with the use of the chi 2 test, with the alpha-value set at .05. RESULTS: The accuracy of breath-sounds assessment in the control environment was 96% (251 of 260); the sensitivity was 96% and the specificity 97%. The accuracy of breath-sounds assessment in the experimental environment was 54% (140 of 260); the sensitivity was .09% and the specificity 98%. Participants were significantly less likely to hear breath sounds in the moving ambulance than in the quiet room (P < .001). CONCLUSION: Assessment of breath sounds is hampered by the environment of a moving ambulance.

Ambulances↗

Do pulse checks cause a significant delay in the initial defibrillation sequence?

This study was undertaken to determine if checking for a pulse between initial defibrillations causes a clinically significant delay in the administration of the defibrillations. Ten emergency department nurses and 10 emergency medicine resident physicians were timed delivering three successive defibrillations (200, 300 and 360 J) to a manikin under three randomly assigned scenarios: (1) without pulse checks; (2) with pulse checks performed by an assistant; and (3) with pulse checks performed by the participant. All participants performed the three defibrillation scenarios using three different models of defibrillators. Repeated measures analysis of variance was used to compare mean defibrillation times for the three scenarios. The mean time was 20.4 +/- 1.0 s for defibrillation without pulse checks; 20.2 +/- 1.2 s with pulse checks by an assistant and 22.0 +/- 2.0 s with pulse checks by the participant. There was a statistically significant difference between no pulse checks and pulse checks by the participant. No statistically significant difference was noted between no pulse checks and pulse checks by an assistant. We conclude that checking for a pulse does cause a statistically significant delay in the administration of defibrillations. This difference, however, is not likely to be clinically relevant.

Analysis of Variance↗

A comparison of oxygen administration practices of EMTs and emergency physicians.

This study examined whether emergency medical technicians (EMTs) withhold oxygen from hypothetical patients whom emergency physicians would treat with high-flow oxygen, particularly chronic obstructive pulmonary disease (COPD) patients. A survey describing 12 hypothetical patients was distributed to 33 emergency physicians, 30 newly trained EMTs, and 27 experienced EMTs. For each patient, the respondents were asked to identify the most appropriate prehospital oxygen administration rate as "low flow" or "high flow". Using an alpha value of .05, chi 2 analysis was used to compare the frequency of high-flow oxygen administration for the three groups. Newly trained EMTs were significantly more likely than physicians to administer high-flow oxygen to patients with COPD who were not receiving home oxygen. Otherwise, the oxygen administration practices of EMTs were not inconsistent with those of emergency physicians.

Adult↗

Can prehospital personnel detect hypoxemia without the aid of pulse oximeters?

Although pulse oximeters have been proven accurate in the prehospital environment, they have not been proven to be necessary. This study was undertaken to determine if emergency medical services (EMS) providers can identify hypoxemia without pulse oximetry. An oximeter was placed at the ambulance entrance to the emergency department (ED), and EMS personnel obtained saturation levels on all patients on arrival. Hypoxemia was defined as a saturation level of 95% or less. The hypoxemia was classified as "recognized" if the patient received aggressive intervention and "unrecognized" if the patient did not. One hundred eighty patients were enrolled in the study; 30 had a saturation level of 95% or less. Twenty-seven (90%) of those patients had "unrecognized" hypoxemia. Twenty-three (85.2%) of the 27 patients with "unrecognized" hypoxemia did not complain of respiratory distress. Thus, there are patients whose hypoxemia is unrecognized by EMS providers, and this occurs most frequently in patients who do not complain of respiratory distress.

Chi-Square Distribution↗

Comparison of staples vs suturing for securing central venous catheters.

OBJECTIVE: To determine whether skin staples can be used to secure central venous catheters as effectively as does suturing. METHODS: A prospective, randomized trial of techniques to secure a central venous catheter was performed in a medical school human anatomy laboratory using human cadavers. Central lines were secured to the upper left thorax using either standard suture material (000 silk) or skin staples (5.7 mm x 3.8 mm). Once secured, an upward force was applied to the hub of the catheter perpendicular to the skin. The amount of force needed to break the catheter hub free of the skin was measured in kg. A total of 10 measurements were made for each of 3 methods for securing the catheters (2 sutures, 2 staples, 4 staples). In addition, the site of catheter breakage was recorded. RESULTS: Those catheter hubs secured by 2 sutures required a mean force of 3.1 +/- 0.5 kg to cause breakage, and the break always occurred at the suture. Those hubs secured by 2 staples gave way at 3.0 +/- 0.3 kg (p = NS), while those secured with 4 staples gave way at 4.5 +/- 1.4 kg (p < 0.05). Although 1 hub did break, in all other stapled cases, the break occurred at the staple. CONCLUSIONS: Based on this cadaver model, use of staples appears to be as effective as suturing for securing central venous catheters. Further studies of safety and time for placement are needed.

Cadaver↗

Serum estradiol in the differential diagnosis of ectopic pregnancy.

In a prospective study using a cutoff value of 140 pg/mL, serum estradiol 17-beta assay had a sensitivity of 83% and a specificity of 100% in differentiating ectopic pregnancy (6 patients) from normal pregnancy with threatened abortion proceeding to viability (7 patients). In differentiating threatened abortion from spontaneous abortion (9 patients), the estradiol assay had a sensitivity of 88.9% and a specificity of 100%. All but one of the patients with ectopic pregnancy had estradiol levels below the cutoff value of 140 pg/mL, as did all but one of the patients who had spontaneous abortion. All the patients who had threatened abortion that progressed to viability had values well above the cutoff level. The mean estradiol values for the viable pregnancy group were significantly different from those of the other two groups. These data suggest that, at the institution where this study was done, serum estradiol determinations may be of value in the differentiation of both ectopic pregnancy and spontaneous abortion from threatened abortion but appears to be of very limited usefulness in distinguishing ectopic pregnancy from spontaneous abortion. The validity of these conclusions is limited by the small number of subjects. Further studies comprising greater numbers of subjects are needed.

Abortion, Spontaneous↗

Is ambulance transport time with lights and siren faster than that without?

STUDY OBJECTIVE: To determine whether ambulance transport time from the scene to the emergency department is faster with warning lights and siren than that without. DESIGN: In a convenience sample, transport times and routes of ambulances using lights and sirens were recorded by an observer. The time also was recorded by a paramedic who drove an ambulance without lights and siren over identical routes during simulated transports at the same time of day and on the same day of the week as the corresponding lights-and-siren transport. SETTING: An emergency medical service system in a city with a population of 46,000. PARTICIPANTS: Emergency medical technicians and paramedics. RESULTS: Fifty transport times with lights and siren averaged 43.5 seconds faster than the transport times without lights and siren [t = 4.21, P = .0001]. CONCLUSION: In this setting, the 43.5-second mean time savings does not warrant the use of lights and siren during ambulance transport, except in rare situations or clinical circumstances.

Ambulances↗

Prehospital blood pressures: inaccuracies caused by ambulance noise?

Blood pressure measurements in a moving ambulance can be difficult to obtain. Sirens, engine noise, and road noise can all interfere with the accurate detection of a patient's blood pressure. This study was undertaken to determine the influence of ambulance noise and vibration on auscultated blood pressures. A model was developed that used dynamic pressures to simulate systolic Korotkoff sounds. Forty-nine emergency personnel were asked to obtain blood pressures using the model in both a quiet environment and in a moving ambulance. A total of 485 blood pressure measurements were obtained. Systolic pressures were randomized to two settings: 76 mm Hg and 138 mm Hg. Stationary readings were compared with moving readings using analysis of variance for repeated measures. Systolic blood pressure measurements obtained in the quiet environment averaged 133 +/- 5 mm Hg at the high setting, and 45 +/- 6 mm Hg at the low setting. Systolic blood pressure measurements obtained in a moving ambulance averaged 86 +/- 7 mm Hg at the high setting, and 41 +/- 7 mm Hg at the low setting. The average differences between quiet and moving measurements were 47 mm Hg at the "high" setting (P < .01) and 4 mm Hg at the "low" setting (P > .01). At physiological levels, blood pressures obtained in moving ambulances differ significantly from those obtained in a quiet environment, which may be caused by road noise and ambulance motion.

Ambulances↗