Improvements in the design of linear diffusers for photodynamic therapy.

The angular radiance distribution of several linear diffusers used for photodynamic therapy (PDT) was measured. The forward scattering found previously was not observed for these designs. The improved isotropy leads to a better agreement between intended treatment site and actual maximum of the fluence rate profile when the linear diffuser is used in a hollow, cylindrical organ.

Diffusion

Light distribution by linear diffusing sources for photodynamic therapy.

The distribution of the light emitted by linear light diffusers commonly employed in photodynamic therapy (PDT) has been investigated. A device is presented which measures the angular distribution of the exiting light at each point of the diffuser. With these data the fluence rate in air or in a cavity at some distance from the diffuser can be predicted. The results show that the light is scattered from the diffuser predominantly in the forward direction. Experiments and calculations show that the fluence rate in air and in a cavity of scattering tissue at some distance from the diffuser has a maximum near the tip of the diffuser, instead of near the middle. However, the fluence rate resulting from an interstitial diffuser in a purely scattering tissue phantom shows a maximum in the bisecting plane of the diffuser as would be predicted when the diffuser emitted light isotropically. The scattering nature of the tissue is expected to cancel the anisotropy of the diffuser.

Animals

Ex vivo light dosimetry and Monte Carlo simulations for endobronchial photodynamic therapy.

The light distribution during photodynamic therapy of the bronchial tree has been estimated by measuring the fluence rate in ex vivo experiments on dissected pig bronchi. The trachea was illuminated (630 nm) with a cylindrical diffuser and the fluence rate was measured with a fibre optic isotropic probe. The experiment with the diffuser on the central axis was also simulated with Monte Carlo techniques using the optical properties that were determined with a double-integrating-sphere set-up. The results from ex vivo experiments and the Monte Carlo simulations were found to agree within the error of measurement (15%), indicating that the Monte Carlo technique can be used to estimate the light distribution for varying geometries and optical properties. The results showed that the light fluence rate in the mucosa of the tracheal tract may increase by a factor of six compared to the fluence rate in air (in the absence of tissue). This is due to the scattering properties of the tissue and the multiple reflections within the cavity. Further ex vivo experiments showed that the positioning of the diffuser is critical for the fluence rate in the lesion to be treated. When the position of the diffuser was changed from the central axis to near the lesion, the fluence rate in the mucosa increased significantly by several orders of magnitude as compared to the initial (central) illumination. The inter- and intraspecimen variations in this increase were large (+/- 35%) because of variations in optical and geometrical properties and light source positioning, respectively. These variations might cause under- or overdosage resulting in either insufficient tumour necrosis or excessive normal tissue damage.

Animals