Automated registration of breast lesions in temporal pairs of mammograms for interval change analysis--local affine transformation for improved localization.

Analysis of interval change is important for mammographic interpretation. The aim of this study is to evaluate the use of an automated registration technique for computer-aided interval change analysis in mammography. Previously we developed a regional registration technique for identifying masses on temporal pairs of mammograms. In the current study, we improved lesion registration by including a local alignment step. Initially, the lesion position on the prior mammogram was estimated based on the breast geometry. An initial fan-shaped search region was then defined on the prior mammogram. In the second stage, the location of the fan-shaped region on the prior mammogram was refined by warping, based on an affine transformation and simplex optimization in a local region. In the third stage, a search for the best match between the lesion template from the current mammogram and a structure on the prior mammogram was carried out within the search region. This technique was evaluated on 124 temporal pairs of mammograms containing biopsyproven masses. Eighty-seven percent of the estimated lesion locations resulted in an area overlap of at least 50% with the true lesion locations and an average distance of 2.4 +/- 2.1 mm between their centroids. The average distance between the estimated and the true centroid of the lesions on the prior mammogram over all 124 temporal pairs was 4.2 +/- 5.7 mm. The registration accuracy was improved in comparison with our previous study that used a data set of 74 temporal pairs of mammograms. This improvement in accuracy resulted from the improved geometry estimation and the local affine transformation.

Biophysical Phenomena↗

Selection of an optimal neural network architecture for computer-aided detection of microcalcifications--comparison of automated optimization techniques.

Many computer-aided diagnosis (CAD) systems use neural networks (NNs) for either detection or classification of abnormalities. Currently, most NNs are "optimized" by manual search in a very limited parameter space. In this work, we evaluated the use of automated optimization methods for selecting an optimal convolution neural network (CNN) architecture. Three automated methods, the steepest descent (SD), the simulated annealing (SA), and the genetic algorithm (GA), were compared. We used as an example the CNN that classifies true and false microcalcifications detected on digitized mammograms by a prescreening algorithm. Four parameters of the CNN architecture were considered for optimization, the numbers of node groups and the filter kernel sizes in the first and second hidden layers, resulting in a search space of 432 possible architectures. The area Az under the receiver operating characteristic (ROC) curve was used to design a cost function. The SA experiments were conducted with four different annealing schedules. Three different parent selection methods were compared for the GA experiments. An available data set was split into two groups with approximately equal number of samples. By using the two groups alternately for training and testing, two different cost surfaces were evaluated. For the first cost surface, the SD method was trapped in a local minimum 91% (392/432) of the time. The SA using the Boltzman schedule selected the best architecture after evaluating, on average, 167 architectures. The GA achieved its best performance with linearly scaled roulette-wheel parent selection; however, it evaluated 391 different architectures, on average, to find the best one. The second cost surface contained no local minimum. For this surface, a simple SD algorithm could quickly find the global minimum, but the SA with the very fast reannealing schedule was still the most efficient. The same SA scheme, however, was trapped in a local minimum on the first cost surface. Our CNN study demonstrated that, if optimization is to be performed on a cost surface whose characteristics are not known a priori, it is advisable that a moderately fast algorithm such as a SA using a Boltzman cooling schedule be used to conduct an efficient and thorough search, which may offer a better chance of reaching the global minimum.

Algorithms↗

Analysis of temporal changes of mammographic features: computer-aided classification of malignant and benign breast masses.

A new classification scheme was developed to classify mammographic masses as malignant and benign by using interval change information. The masses on both the current and the prior mammograms were automatically segmented using an active contour method. From each mass, 20 run length statistics (RLS) texture features, 3 speculation features, and 12 morphological features were extracted. Additionally, 20 difference RLS features were obtained by subtracting the prior RLS features from the corresponding current RLS features. The feature space consisted of the current RLS features, the difference RLS features, the current and prior speculation features, and the current and prior mass sizes. Stepwise feature selection and linear discriminant analysis classification were used to select and merge the most useful features. A leave-one-case-out resampling scheme was used to train and test the classifier using 140 temporal image pairs (85 malignant, 55 benign) obtained from 57 biopsy-proven masses (33 malignant, 24 benign) in 56 patients. An average of 10 features were selected from the 56 training subsets: 4 difference RLS features, 4 RLS features, and 1 speculation feature from the current image, and 1 speculation feature from the prior, were most often chosen. The classifier achieved an average training Az of 0.92 and a test Az of 0.88. For comparison, a classifier was trained and tested using features extracted from the 120 current single images. This classifier achieved an average training Az of 0.90 and a test Az of 0.82. The information on the prior image significantly (p = 0.015) improved the accuracy for classification of the masses.

Algorithms↗

Application of artificial neural networks to modeling and prediction of ambient ozone concentrations.

The deterministic modeling of ambient O3 concentrations is difficult because of the complexity of the atmospheric system in terms of the number of chemical species; the availability of accurate, time-resolved emissions data; and the required rate constants. However, other complex systems have been successfully approximated using artificial neural networks (ANNs). In this paper, ANNs are used to model and predict ambient O3 concentrations based on a limited number of measured hydrocarbon species, NOx compounds, temperature, and radiant energy. In order to examine the utility of these approaches, data from the Coastal Oxidant Assessment for Southeast Texas (COAST) program in Houston, TX, have been used. In this study, 53 hydrocarbon compounds, along with O3, nitrogen oxides, and meteorological data were continuously measured during summer 1993. Steady-state ANN models were developed to examine the ability of these models to predict current O3 concentrations from measured VOC and NOx concentrations. To predict the future concentrations of O3, dynamic models were also explored and were used for extraction of chemical information such as reactivity estimations for the VOC species. The steady-state model produced an approximation of O3 data and demonstrated the functional relationship between O3 and VOC-NOx concentrations. The dynamic models were able to the adequately predict the O3 concentration and behavior of VOC-NOx-O3 system a number of hourly intervals into the future. For 3 hr into the future, O3 concentration could be predicted with a root-mean squared error (RMSE) of 8.21 ppb. Extending the models further in time led to an RMSE of 11.46 ppb for 5-hr-ahead values. This prediction capability could be useful in determining when control actions are needed to maintain measured concentrations within acceptable value ranges.

Air Pollution↗

Stereomammography: evaluation of depth perception using a virtual 3D cursor.

We are evaluating the usefulness of stereomammography in improving breast cancer diagnosis. One area that we are investigating is whether the improved depth perception associated with stereomammography might be significantly enhanced with the use of a virtual 3D cursor. A study was performed to evaluate the accuracy of absolute depth measurements made in stereomammograms with such a cursor. A biopsy unit was used to produce digital stereo images of a phantom containing 50 low contrast fibrils (0.5 mm diam monofilaments) at depths ranging from 1 to 11 mm, with a minimum spacing of 2 mm. Half of the fibrils were oriented perpendicular (vertical) and half parallel (horizontal) to the stereo shift direction. The depth and orientation of each fibril were randomized, and the horizontal and vertical fibrils crossed, simulating overlapping structures in a breast image. Left and right eye images were generated by shifting the x-ray tube from +2.5 degrees to -2.5 degrees relative to the image receptor. Three observers viewed these images on a computer display with stereo glasses and adjusted the position of a cross-shaped virtual cursor to best match the perceived location of each fibril. The x, y, and z positions of the cursor were indicated on the display. The z (depth) coordinate was separately calibrated using known positions of fibrils in the phantom. The observers analyzed images of two configurations of the phantom. Thus, each observer made 50 vertical filament depth measurements and 50 horizontal filament depth measurements. These measurements were compared with the true depths. The correlation coefficients between the measured and true depths of the vertically oriented fibrils for the three observers were 0.99, 0.97, and 0.89 with standard errors of the estimates of 0.39 mm, 0.83 mm, and 1.33 mm, respectively. Corresponding values for the horizontally oriented fibrils were 0.91, 0.28, and 0.08, and 1.87 mm, 4.19 mm, and 3.13 mm. All observers could estimate the absolute depths of vertically oriented objects fairly accurately in digital stereomammograms; however, only one observer was able to accurately estimate the depths of horizontally oriented objects. This may relate to different aptitudes for stereoscopic visualization. The orientations of most objects in actual mammograms are combinations of horizontal and vertical. Further studies are planned to evaluate absolute depth measurements of fibrils oriented at various intermediate angles and of objects of different shapes. The effects of the shape and contrast of the virtual cursor and the stereo shift angle on the accuracy of the depth measurements will also be investigated.

Biophysical Phenomena↗

Feature selection and classifier performance in computer-aided diagnosis: the effect of finite sample size.

In computer-aided diagnosis (CAD), a frequently used approach for distinguishing normal and abnormal cases is first to extract potentially useful features for the classification task. Effective features are then selected from this entire pool of available features. Finally, a classifier is designed using the selected features. In this study, we investigated the effect of finite sample size on classification accuracy when classifier design involves stepwise feature selection in linear discriminant analysis, which is the most commonly used feature selection algorithm for linear classifiers. The feature selection and the classifier coefficient estimation steps were considered to be cascading stages in the classifier design process. We compared the performance of the classifier when feature selection was performed on the design samples alone and on the entire set of available samples, which consisted of design and test samples. The area Az under the receiver operating characteristic curve was used as our performance measure. After linear classifier coefficient estimation using the design samples, we studied the hold-out and resubstitution performance estimates. The two classes were assumed to have multidimensional Gaussian distributions, with a large number of features available for feature selection. We investigated the dependence of feature selection performance on the covariance matrices and means for the two classes, and examined the effects of sample size, number of available features, and parameters of stepwise feature selection on classifier bias. Our results indicated that the resubstitution estimate was always optimistically biased, except in cases where the parameters of stepwise feature selection were chosen such that too few features were selected by the stepwise procedure. When feature selection was performed using only the design samples, the hold-out estimate was always pessimistically biased. When feature selection was performed using the entire finite sample space, the hold-out estimates could be pessimistically or optimistically biased, depending on the number of features available for selection, the number of available samples, and their statistical distribution. For our simulation conditions, these estimates were always pessimistically (conservatively) biased if the ratio of the total number of available samples per class to the number of available features was greater than five.

Algorithms↗

Classification of malignant and benign masses based on hybrid ART2LDA approach.

A new type of classifier combining an unsupervised and a supervised model was designed and applied to classification of malignant and benign masses on mammograms. The unsupervised model was based on an adaptive resonance theory (ART2) network which clustered the masses into a number of separate classes. The classes were divided into two types: one containing only malignant masses and the other containing a mix of malignant and benign masses. The masses from the malignant classes were classified by ART2. The masses from the mixed classes were input to a supervised linear discriminant classifier (LDA). In this way, some malignant masses were separated and classified by ART2 and the less distinguishable benign and malignant masses were classified by LDA. For the evaluation of classifier performance, 348 regions of interest (ROI's) containing biopsy proven masses (169 benign and 179 malignant) were used. Ten different partitions of training and test groups were randomly generated using an average of 73% of ROI's for training and 27% for testing. Classifier design, including feature selection and weight optimization, was performed with the training group. The test group was kept independent of the training group. The performance of the hybrid classifier was compared to that of an LDA classifier alone and a backpropagation neural network (BPN). Receiver operating characteristics (ROC) analysis was used to evaluate the accuracy of the classifiers. The average area under the ROC curve (A(z)) for the hybrid classifier was 0.81 as compared to 0.78 for the LDA and 0.80 for the BPN. The partial areas above a true positive fraction of 0.9 were 0.34, 0.27 and 0.31 for the hybrid, the LDA and the BPN classifier, respectively. These results indicate that the hybrid classifier is a promising approach for improving the accuracy of classification in CAD applications.

Biopsy↗