PubMed Health⌕ Search

Biomedical subjects

L Huber

Publications and source records attributed to L Huber.

At least 37 records · Page 2Linked to original sources

Influence of different conditioning methods on force and fatigue resistance in chronically stimulated skeletal muscles.

A study was undertaken to compare different conditioning methods for the transformation of latissimus dorsi muscle into a fatigue resistant one for application in circulatory assist. In ten sheep four electrodes were sutured to the epineurium of the left thoracodorsal nerve for indirect electrical stimulation of the latissimus dorsi muscle. In six sheep a "carousel stimulation," a special multichannel stimulation, in combination with a recently developed conditioning protocol was used for muscle conditioning (multichannel method). In four sheep, a conventional stimulation protocol using single channel stimulation was applied for transformation of the muscle (single channel method). The final experiments were carried out when fatigue resistance was obtained. The maximum tetanic forces at different preloads were determined and fatigue resistance was tested during 20 minutes of continuous stimulation. Both conditioning patterns led to fatigue-free chronic stimulation. Muscles conditioned by multichannel stimulation exhibited between 20% and 33% less force than the contralateral unconditioned muscles, whereas in the single channel group this loss was between 32% and 43%. Thus, the multichannel method revealed relatively superior in preserving muscle force for chronic stimulation.

Animals↗

[Circulatory support by an electrically stimulated muscle flap. Experimental experiences].

Functional electrical stimulation of the latissimus dorsi muscle flap for circulatory assistance extends the traditional concept of using this flap for reconstructive procedures into the field of cardiac surgery. It requires a transformed muscle which is able to contract for long periods of time without fatigue. Two main groups of experiments have been carried out in sheep. In six sheep the latissimus dorsi muscle (MLD) was transformed into a fatigue-resistant muscle by the means of multichannel stimulation of the supplying motor nerve. After that, stimulation of MLD at a frequency of 70 contractions per minute could be performed continuously without significant muscle fatigue. The loss of maximal force caused by the conditioning procedure was about one third of the initial force. In a second series of acute experiments the MLD was used for cardiomyoplasty. The muscle was divided into two parts which were wrapped around the heart in two different forms. The resting tension of the muscle was preserved. EKG-synchronous stimulation resulted in an increase in left ventricular pressure between 12 and 53%. The increase in arterial pressure was between 10,6 and 58%.

Animals↗

An implantable seal-less centrifugal pump with integrated double-disk motor.

Thrombus formation and sealing problems at the shaft as well as the compact and efficient design of the driving unit have been major difficulties in the construction of a long-term implantable centrifugal pump. To eliminate the problems of the seal, motor size, and efficiency, two major steps were taken by modifying the Vienna implantable centrifugal pump. First, a special driving unit was developed, in which the permanent magnets of the motor themselves are used for coupling the force into the rotor. Second, the rotor shaft in the pumping chamber was eliminated by adopting a concept recently presented by Ohara. The rotor is supported by 3 pins, which run on a carbon disk, whose concave shape leads to stabilization. The device has the following specifications: size: 65 mm (diameter) by 35 mm (height), 101 cm3; priming volume 30 cm3, 240 g; and a 6-pole brushless double disk DC motor. The required input power of the described prototype is 15 W at 150 mm Hg, 5 L/min (overall eta = 11%), and has an in vitro index of hemolysis (IH) of 0.0046 g/100 L. The test for in vitro thrombus growth exhibited far less thrombus formation in the new design than in designs with axles. In conclusion, the design of a special driving unit and the elimination of the axle led to the construction of a small pump with very low blood traumatization.

Biomechanical Phenomena↗

Experimental in situ conditioning of the latissimus dorsi muscle for circulatory assist by multichannel stimulation.

This study was undertaken to survey the changes in force and fatigue of the latissimus dorsi muscle during transformation into a fatigue-resistant muscle by indirect or nervous multichannel stimulation. In sheep, a silicone chamber connected to a pressure-transducing system was implanted under the left latissimus dorsi muscle. Muscle conditioning was performed by multichannel (carousel) stimulation of the thoracodorsal nerve. The program was started with active periods of 10 min/h producing 10 tetanic contractions/min. It was increased until 70 contractions/min could be performed during 24 h. The changes of muscle force and fatigue were monitored by the silicone balloon system. After a mean period of 22 weeks, fatigue resistance was reached. The fatigue-resistant muscle was able to produce a pressure of about 100 mm Hg in the balloon. After finishing the conditioning procedure, muscle forces and the fatigue resistance of the conditioned muscle were evaluated. The conditioned muscle showed only a minimal decrease of force during 20 min. Under a preload of 20 N, it exhibited a maximum tetanic tension of 95 N.

Animals↗

Comparison of muscle activity between conventional and neuromuscular splints.

The muscle relaxation appliance (MRA) has been used in the treatment of myofascial pain dysfunction (MPD) patients. The neuromuscular orthotic is a version of the MRA and is constructed from a three-dimensional mandibular position when muscles are in a state of minimal electromyographic (EMG) activity. The purpose of this study was to investigate the affect of two muscle relaxation appliances and a placebo (cotton rolls) on EMG activity of the functional masseter and anterior temporalis muscles. A centric relation mandibular MRA and a neuromuscular orthotic were constructed under controlled protocols for 12 women MPD patients with a mean age of 38 years. EMG measurements were taken during a 10-second clench of both appliance and placebo. No statistical difference was found between the centric relation mandibular MRA and neuromuscular orthotic. A statistically significant difference was found between the mean EMG values of the placebo and two treatment appliances.

Adult↗

In vitro investigation of thrombogenesis in rotary blood pumps.

Thrombus formation at sealing and stagnation areas remains a major problem in the development of rotary blood pumps. Until now, the complex phenomena could only be studied in vivo. In this study, an in vitro mock circulation previously used for hemolysis studies was adapted for thrombosis evaluation. Blood was collected in the slaughterhouse with strict avoidance of air contact and was heparinized (1.5 U heparin/ml blood; activated coagulation time [ACT]: initially, 140-180 s; after collection, 400-600 s). During the test, the ACT decreased gradually. The tests were stopped after 90 to 180 min at an ACT of 1.5 times the initial value. Thrombus formation was observed at the same locations as observed in left-heart assist devices (sealing area, connecting bolts, and stagnant water areas at connectors). The thrombi were similar in shape, color, and histology to those found after 2 to 4 days in vivo. This test provides a valuable tool for evaluating thrombus formation in prototypes and screening tests of different rotary pump designs.

Animals↗

Minimization of hemolysis in centrifugal blood pumps: influence of different geometries.

Centrifugal blood pumps are of substantial importance for intraoperative extracorporeal circulation and for temporary cardiac assist. Their development and improvement raises many specific questions, especially on mechanical blood properties, flow distribution, and the resulting biocompatibility. In this comprehensive study the influence of various pump geometries on blood trauma was investigated. For this purpose analytical calculations, hydrodynamic performance, numerical simulation, in vitro hemolysis tests and in vivo experiments were used. The gap between rotor and housing was found to be crucial showing a distinct minimum of hemolysis at a gap of 1.5 mm (in vitro increase of plasma free hemoglobin per 100 ml plasma an hour: delta fHb/hour = 2.4 +/- 0.83 mg%/h at 1.5 mm versus 12 +/- 2.2 mg%/h at 2.5 mm; p < 0.05). Housing diameter and shape of the vanes were of less importance for blood traumatization (d = 60 mm: delta fHb/hour = 6.36 +/- 1.8 mg%/h; d = 70 mm: fHb = 7.1 +/- 1.9 mg%/h; straight radial vanes: 5.2 +/- 1.8 mg%/h; straight inclined vanes: 6.8 +/- 1.2 mg%/h; flexed vanes: 6.1 +/- 2.0 mg%/h). Three animal experiments confirmed the optimization of geometry, with a mean fHb of 2.5 to 3.2 mg% in steady state. Hydrodynamic efficiency revealed to be a necessary, but not a sufficient and sensitive criterion for hemolysis minimization (e.g. changes of eta < 10% for changes of fHb > 500%). Numerical simulation gives an improved insight in flow distribution, but can not yet be applied for quantification of blood trauma.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Role of Klion ointment in the treatment of crural ulcer.

Klion ointment has been used for the cleansing of crural ulcer in 28 patients. The results of treatment were compared to a control group of 17 patients treated with another method. In response to metronidazole the ulcers were cleared within 1-3 weeks, discharge ceased, and the accompanying inflammation and pain were also moderated. The starting proliferation and epithelization indicated the favourable action of Klion ointment form the standpoint of the complete wound healing process.

Adult↗

Alteration of plasma low density lipoprotein from smokers.

Thiobarbituric acid reactive substances (TBARS) in 38 low density lipoprotein (LDL) samples from 21 healthy male non-smokers and 17 smokers (greater than 20 cigarettes per day) were measured before and after oxidation. TBARS in the freshly isolated LDL from non-smokers and smokers were similar, however, oxidized LDL samples from smokers developed nearly twofold more TBARS than non-smoker LDL samples. 16 LDLs from 8 smokers and 8 non-smokers were conditioned in redox-metal containing F-10 medium and subsequently added to P 388 D.1 macrophage cultures. LDL dependent cholesteryl ester increase in the P 388 D.1 cells after an 18 h incubation with non-smoker LDL was significantly lower than in the cells incubated with smoker LDL (P less than 0.01). A higher reacylation rate of cholesterol in P 388 D.1 cells incubated with smoker LDL (P less than 0.05) suggests that LDL-cholesterol uptake is significantly higher in P 388 D.1 cells incubated with smoker-LDL than in P 388 D.1 cultures exposed to non-smoker LDL. This finding indicates that smoking might contribute to increased shunting of LDL into macrophages. The vitamin E content of 6 non-smoker LDL samples was significantly higher than that in 6 smoker-LDL samples (P less than 0.01). We conclude that the vitamin E/LDL ratio may differ significantly in heavy smokers and non-smokers.

Adult↗

Vacuum generation in pneumatic artificial heart drives with a specially designed ejector system.

To improve the filling characteristics of pneumatically driven membrane artificial hearts (AHs), a vacuum is applied during diastole. This paper describes an ejector system for AH-drivers based on the Venturi effect, which was designed for this purpose. It provides vacuums of more than -40 mmHg at flow rates up to 50 l/min requiring a supplying primary gas pressure of less than 150 kPa (1140 mmHg). Under normal working conditions, the necessary supply flow was less than 5l/min. The device is small, cheap, quiet and fail-safe, and has been evaluated successfully in experimental and clinical use.

Heart, Artificial↗

Control of the total artificial heart: new aspects in human versus animal experience.

Control strategies for total artificial heart application have generally been based on experience with healthy animals. Human patients in a bad state of health who have impaired organ functions and who are subjected to intensive care procedures can develop atypical hemodynamic behavior. In these patients, both unstable and hyperstable behavior of the vascular resistance were observed. Therefore, regulation of cardiac output (CO) by pressure parameters only was avoided and CO was adjusted to obtain an appropriate O2-utilization (O2U). Intending to keep the O2U within ranges of 20-25%, we obtained cardiac indexes between 3.3 and 4.4 L/m2/min (CO 6-8 L/min), which is higher than other cardiac indexes reported. A CO of 10.5 L/min was even necessary to obtain an O2U of 30% in a septic patient. This strategy caused a stable driving management and led to a rapid hemodynamic stabilization and general improvement of the patients' condition. Results indicate that it is also very important to monitor metabolic parameters for appropriate driver adjustment as well, especially in the early postoperative phase, and that O2-U is a sensitive and useful parameter for this purpose.

Animals↗

Clinical evaluation of a new high-flux cellulose acetate membrane.

One major goal of dialysis therapy has become the removal of beta 2-microglobulin (beta 2-m). The interdialytic elimination of beta 2-m was studied using a newly developed high-flux cellulose acetate (CA) membrane. The results show that high-flux CA dialyzers offer better biocompatibility than classical Cuprophan or high-flux Cuprophan devices, with regard to leukopenia, C3a desarg generation, and elastase release from polymorphonuclear (PMN) leukocytes. Compared to high-flux CA membranes, high-flux PMMA membranes induce less C3a desarg formation but comparable leukopenia. High-flux PMMA membranes, however cause greater leukocyte stimulation than CA as demonstrated by more PMN elastase release during hemodialysis. Using high-flux CA or high-flux PMMA membranes, serum beta 2-m levels decreased 32% during dialysis. Serum beta 2-m dropped 10% with high-flux Cuprophan membranes, but remained unchanged with conventional Cuprophan dialyzers. Sieving coefficients for beta 2-microglobulin (beta 2-m) were virtually zero with classical Cuprophan and 0.66 with high-flux cellulose acetate membranes. High-flux membranes made of Cuprophan and PMMA gave coefficients of 0.25 and 0.45, respectively. This indicates the high removal capacity of the new CA-membrane for substances with high molecular weight. This high-flux CA membrane thus appears to combine a good degree of biocompatibility with a high capacity for beta 2-m removal.

Adult↗

Analysis of fluorescent low density lipoprotein uptake by lymphocytes. Paradoxical increase in the elderly.

Uptake of dioctadecylindocarbocyanine (DiI)-labelled low density lipoproteins (LDL) by peripheral blood lymphocytes (PBL) from young healthy donors has been characterized by flow cytometric analysis. The receptor positive cells were primarily (greater than 70%) T cells. Saturation and competition studies were performed with freshly isolated PBL as well as after a 2-3-day incubation in cholesterol-free medium. In both cases uptake was specific for LDL and not high density lipoprotein. It was also abrogated by chemical modification of apo B, and was not shown by PBL from a patient with familial hypercholesterolemia. DiI-LDL-uptake by cells from elderly donors was compared with that of PBL from young donors. There was a clear increase in uptake by freshly isolated PBL from aged donors which was shown not to stem from underlying "sickness". In contrast, uptake by pre-incubated cells was very variable, in terms of percentage receptor-positive cells and the level of uptake by those cells. However, LDL rescued mevinolin-suppressed mitogen responses from both old and young donors indicating that there is no impairment of uptake or degradation of LDL by PBL from the elderly.

Adult↗

The chronically stimulated muscle as an energy source for artificial organs. Preliminary results of a basic study in sheep.

In 5 adult sheep the psoas muscle of one side was electrically stimulated through the muscle nerves with an implantable stimulation unit for more than 5 weeks. In the final experiments the isometric tetanic tension of the stimulated muscles was reduced to 50-70% of the contralateral normal muscle. The use of only 15 Hz as a stimulation frequency led to a transformation of the originally fast muscle into a slow muscle with more resistance to fatigue. Future application of the chronically stimulated psoas muscle for driving artificial organs is discussed.

Animals↗