[Use of peripheral electro-neurostimulation for obstetric analgesia].

Labor analgesia by antipain peripheral electro-neurostimulation (APES), including paravertebral transcutaneous electro-neurostimulation (TENS), two-channel TENS, rectal electrostimulation, using the Eliman device, was conducted in 234 term deliveries. The results were good or satisfactory in 94.3% of the parturients. The efficiency of APES increases where fentanyl or seduxen are administered, their single doses being sufficient.

Adolescent↗

[Transcutaneous electrostimulation and its place in the treatment of chronic pain syndromes].

In 107 patients with chronic pain syndromes, transcutaneous electrostimulation by an apparatus ELIMAN -101 was used in conjunction with drug treatment and physiotherapy. On the basis of a complex of estimation tests, the patients studied were divided into three groups depending on the degree of the analgesic effect. A good analgesic response was obtained in 65.4% of the patients, satisfactory in 28.1%, unsatisfactory in 6.5%. It is considered advisable to include the method of transcutaneous electrostimulation into the regimen of the treatment for chronic pain syndromes.

Adult↗

[Analgesia by electric current in the early postoperative period].

In 295 patients in the early postoperative period anesthesia was performed by means of percutaneous electrostimulation with a new national apparatus Eliman-101. The authors note high efficiency of such analgesia in 63,4% of the patients, satisfactory results were obtained in 32,3%. No sufficient anesthesia was achieved in 13 patients (4,3%). There were no side effects and complications.

Adolescent↗

[Criteria of the accuracy of measurement of cardiocycle duration in systems for monitoring of cardiac rhythm variability parameters].

The use of the criteria of the accuracy of measurement of cardiocycle duration in systems for monitoring of cardiac rhythm variability parameters based on no more than 10% deviation of diagnostic characteristics was shown to provide the measuring error of no more than 4 msec at histogram grouping interval 10 msec. An increase in the grouping interval duration causes a decrease in the sensitivity of diagnostic parameters to patient state and diagnostic mistakes.

Heart↗

[Pulsoximetric sensor for diagnosis of intrauterine foetus state during parturition].

Detrimental changes in the degree of blood hemoglobin saturation with oxygen are important evidence of hypoxic states and can be regarded as objective indication to surgical delivery. A new method of fetal pulsoximetry was developed. This method is based on the use of a non-disposable atraumatic pulsoximetric sensor of reflectory type for diagnosis of intrauterine foetus state during parturition. The clinical trial of the system was carried out in 44 women in childbirth and revealed clear differentiation between hypoxic states.