Nonbiodegradable expanded polytetrafluoroethylene-covered stent implantation in porcine peripheral arteries: histologic evaluation of vascular wall response compared with uncoated stents.

PURPOSE: To test the vascular wall response to an expanded polytetrafluoroethylene-covered stent, compared with conventional stenting, up to 6 months after deployment in the vascular district of a swine model. METHODS: Fourteen minipigs underwent implantation of expanded polytetrafluoroethylene-covered stents (CS) and bare stents (BS) in five peripheral arteries. Animals were killed at different time points (from 1 to 180 days). Histopathologic assessment by morphologic and morphometric analysis and by scanning electron microscopy (SEM) were used to assess the incorporation characteristics and re-endothelialization extent of the two types of stents. RESULTS: A total of 70 stents (14 CS and 14 BS in the renal arteries; 28 CS in the iliac arteries, and 14 CS in the aorta) were implanted. Microscopic examination confirmed the absence of occlusive thrombi in both the CS and BS groups. Microthrombi were observed in 10 of 13 CS (77% of cases) and in four of four BS (100% of cases, p < 0.05). Inflammation was mild in 69% of segments in which a CS was implanted and in 74% of segments in which a BS was implanted (p = NS), while a severe inflammatory reaction was observed in 6% of CS segments and in 8% of BS segments (p = NS). No differences were detected at the long-term analysis between neointimal thickness in CS compared with BS segments (0.46 +/- 0.18 mm vs 0.42 +/- 0.26 mm at 90 days and 0.36 +/- 0.08 mm vs 0.35 +/- 0.04 mm at 180 days; p = NS, respectively). At SEM analysis, re-endothelization was evident 15 days after the implant in both CS and BS starting from the stent edges. CONCLUSION: CS implantation did not elicit a more severe thrombotic deposition compared with that of BS. A similar inflammatory reaction of the arterial wall was present in the two stent groups 3 and 6 months following the implant. In addition, CS implantation did not stimulate excessive neointimal formation when compared with BS.

Animals↗

Percutaneous treatment of iliac aneurysms and pseudoaneurysms with Cragg Endopro System 1 stent-grafts.

PURPOSE: To evaluate the feasibility and short-term follow-up results of treating iliac aneurysms by the Cragg Endopro System 1 stent-graft. METHODS: Nine lesions (two pseudoaneurysms and seven atherosclerotic aneurysms) were treated in eight patients by percutaneous implantation of a total of 10 stent-grafts. The procedure was followed by anticoagulation with heparin for 6 days, then antiplatelet therapy. Follow-up was by color Doppler ultrasound scan at 2 days and 3 months after the procedure for all patients, and by venous digital subtraction angiography and/or angio-CT up to 12 months later for four patients. RESULTS: Initial clinical success rate was 100% and there were two minor complications. In one case the delivery system was faulty resulting in failure to deploy the stent-graft. An additional device had to be used. At 3-12 months all prostheses were patent but one patient (12.5%) had a minimal pergraft leak. CONCLUSION: Percutaneous stent-grafting with this device is a safe and efficacious treatment of iliac artery aneurysms.

Aged↗