PubMed Health⌕ Search

Biomedical subjects

L J Gibson

Publications and source records attributed to L J Gibson.

At least 19 recordsLinked to original sources

The effect of pore size on cell adhesion in collagen-GAG scaffolds.

The biological activity of scaffolds used in tissue engineering applications hypothetically depends on the density of available ligands, scaffold sites at which specific cell binding occurs. Ligand density is characterized by the composition of the scaffold, which defines the surface density of ligands, and by the specific surface area of the scaffold, which defines the total surface of the structure exposed to the cells. It has been previously shown that collagen-glycosaminoglycan (CG) scaffolds used for studies of skin regeneration were inactive when the mean pore size was either lower than 20 microm or higher than 120 microm (Proc. Natl. Acad. Sci., USA 86(3) (1989) 933). To study the relationship between cell attachment and viability in scaffolds and the scaffold structure, CG scaffolds with a constant composition and solid volume fraction (0.005), but with four different pore sizes corresponding to four levels of specific surface area were manufactured using a lyophilization technique. MC3T3-E1 mouse clonal osteogenic cells were seeded onto the four scaffold types and maintained in culture. At the experimental end point (24 or 48 h), the remaining viable cells were counted to determine the percent cell attachment. A significant difference in viable cell attachment was observed in scaffolds with different mean pore sizes after 24 and 48 h; however, there was no significant change in cell attachment between 24 and 48 h for any group. The fraction of viable cells attached to the CG scaffold decreased with increasing mean pore size, increasing linearly (R2 = 0.95, 0.91 at 24 and 48 h, respectively) with the specific surface area of the scaffold. The strong correlation between the scaffold specific surface area and cell attachment indicates that cell attachment and viability are primarily influenced by scaffold specific surface area over this range (95.9-150.5 microm) of pore sizes for MC3T3 cells.

3T3 Cells↗

Degradation of a collagen-chondroitin-6-sulfate matrix by collagenase and by chondroitinase.

Highly porous, type I collagen-chondroitin-6-sulfate (collagen-GAG) scaffolds, produced by freeze-drying techniques, have proven to be of value as implants to facilitate the regeneration of certain tissues. The objective of this project was to evaluate changes in the microstructure and mechanical properties of selected collagen-GAG scaffolds as they degrade in an in vitro model system. Environmental scanning electron microscopy and video imaging demonstrated that collagenase degradation caused strut erosion through the creation of 1-3 microm diameter micropits within a 2-h period, leading to eventual removal of strut material and strut breakage. Loss of microstructural topography may have been due to gelatinization when collagen was cleaved by collagenase. Chondroitinase degradation of GAG resulted in swelling of the struts, causing the pores to become smaller and rounder. The compressive modulus of the collagen-GAG matrix decreased when degraded by collagenase, but remained unchanged when degraded by chondroitinase. Carbodiimide-cross-linked matrices were found to have a higher cross-link density, a higher compressive stiffness and a greater resistance to collagenase and chondroitinase, compared to non-cross-linked controls and matrices that were cross-linked by the dehydrothermal process. This investigation provides information that can be used to design collagen-GAG scaffolds with desired compressive stiffness and degradation rate to collagenase and chondroitinase.

Animals↗

Creep does not contribute to fatigue in bovine trabecular bone.

In both cortical and trabecular bone loaded in fatigue, the stress-strain loops translate along the strain axis. Previous studies have suggested that this translation is the result of creep associated with the mean stress applied in the fatigue test. In this study, we measured the residual strrain (corresponding to the translation of the stress-strain loops) in fatigue tests on bovine trabecular bone and compared it to an upper bound estimate of the creep strain in each test. Our results indicate that the contribution of creep to the translation of the stress-strain loops is negligible in bovine trabecular bone. These results, combined with models for fatigue in lower density bone, suggest that that creep does not contribute to the fatigue of normal human bone. Creep may make a significant contribution to fatigue in low-density osteoporotic bone in which trabeculae have resorbed, reducing the connectivity of the trabecular structure.

Adaptation, Physiological↗

A phenomenological model for predicting fatigue life in bovine trabecular bone.

Cyclic loading of bone during daily activities can lead to fatigue degradation and increased risk of fracture in both the young and elderly population. Damage processes under cyclic loading in trabecular bone result in the reduction of the elastic modulus and accumulation of residual strain. These effects increase with increasing stress levels, leading to a progressive reduction in fatigue life. The present work analyzes the effect of stress and strain variation on the above damage processes in bovine trabecular bone, and develops a phenomenological model relating fatigue life to the imposed stress level. The elastic modulus reduction of the bone specimens was observed to depend on the maximum compressive strain, while the rate of residual strain accumulation was a function of the stress level. A model was developed for the upper and lower bounds of bone elastic modulus reduction with increasing number of cycles, at each stress range. The experimental observations were described well by the model. The model predicted the bounds of the fatigue life with change in fatigue stress. The decrease in the fatigue life with increasing stress was related to corresponding increases in the residual strain accumulation rates at the elevated stress levels. The model shows the validity of fatigue predictions from relatively few cyclic experiments, by combining trends observed in the monotonic and the cyclic tests. The model also presents a relatively simple procedure for predicting the endurance limit for bovine trabecular bone specimens.

Adaptation, Physiological↗

Fibroblast contractile force is independent of the stiffness which resists the contraction.

Using a device named the cell force monitor, the contractile force developed by fibroblasts has been studied by measuring the macroscopic contraction of porous collagen-glycosaminoglycan (GAG) matrices over the first 24 h following cell attachment. In this paper, the effect of a variation in the stiffness that resists matrix contraction by cells on the contractile force generated by the cells was determined. Data from these experiments revealed that the contractile force generated by the fibroblasts was independent of the stiffness of the resistance within the range tested (0.7-10.7 N/m). These results suggest that during the time when fibroblasts are attaching to and spreading on collagen-GAG matrices the contractile forces they generate are force limited, not displacement limited. Therefore, the cytoskeletal mechanism of force generation, corresponding with cell elongation, is capable of increasing the displacement of adhesion sites in order to develop the same level of force. Although a detailed understanding of how the passive mechanical signals provided by substrate materials affect cell processes is still unavailable, in vitro modeling of cell-mediated contraction continues to provide useful information.

Animals↗

A kinetoplast DNA minicircle probe (B18) specific for the Leishmania subgenus Viannia.

This paper reports the development, sequence and specificity of probe B18, which hybridizes only to the kinetoplast deoxyribonucleic acid (kDNA) minicircle of Leishmania species of the subgenus Viannia. This probe was developed in 1985 and has been used extensively since, on whole kDNA, Leishmania dot-blots and kDNA minicircles amplified by the polymerase chain reaction.

Animals↗

Microdamage accumulation in bovine trabecular bone in uniaxial compression.

In this study we investigated how microdamage accumulated with increasing compressive strain in bovine trabecular bone. We found that little damage is created in the linear elastic region, up to -0.4 percent strain. At an average strain of -0.76 percent +/-0.25 percent, the stress-strain curve became nonlinear, and peaked at -1.91 percent +/-0.55 percent strain. Microdamage increases rapidly during the peak of the stress-strain curve, and a localized band of damage formed. At strains beyond the ultimate strain, the damaged band widened and the density of damage within the band increased. Microdamage occurred as groupings of cracks; the majority of damage occurred as regions of cross-hatching. All microdamage parameters increased with increasing maximum compressive strain. We also observed exponential relationships between crack numerical density and damage (1(o) - (o)Esec/E0) and between crack length density and damage.

Animals↗

Analysis of crack growth in a 3D Voronoi structure: a model for fatigue in low density trabecular bone.

Both creep and crack growth contribute to the reduction in modulus associated with fatigue loading in bone. Here we simulate crack growth and subsequent strut failure in fatigue in an open-cell, three-dimensional Voronoi structure which is similar to that of low density, osteoporotic bone. The model indicates that sequential failure of struts leads to a precipitous drop in modulus: the failure of 1% of the struts leads to about a 10% decrease in modulus. A parametric study is performed to assess the influence of normalized stress range, relative density, initial crack size, crack shape and cell geometry on the fatigue life. The fatigue life is most sensitive to the relative density and the initial crack length. The results lead to a quantitative expression for the fatigue life associated with crack growth. Data for the fatigue life of trabecular bone are compared with the crack growth model described in this paper as well as with a previous model for creep of a three-dimensional Voronoi structure. In our models, creep dominates the fatigue behavior in low cycle fatigue while crack growth dominates in high cycle fatigue, consistent with previous observations on cortical bone. The large scatter in the trabecular bone fatigue data make it impossible to identify a transition between creep dominated fatigue and crack growth dominated fatigue. The parametric study of the crack growth model indicates that variations in relative density among specimens, initial crack size within trabeculae and crack shape could easily produce such variability in the test results.

Bone Density↗

Growth factor regulation of smooth muscle actin expression and contraction of human articular chondrocytes and meniscal cells in a collagen-GAG matrix.

Recent work has demonstrated that human articular chondrocytes and meniscus cells can express the gene for a contractile actin isoform, alpha-smooth muscle actin (SMA), in vivo. The objective of the present study was to evaluate the effects of two growth factors, transforming growth factor (TGF)-beta1 and platelet-derived growth factor (PDGF)-BB, on the SMA content of these cells and their contraction of a collagen-glycosaminoglycan (GAG) analog of extracellular matrix in vitro. TGF-beta1 was found to markedly increase SMA content of the cells and PDGF-BB decreased SMA expression, with both findings achieving statistical significance. A notable finding was the increased contraction of the collagen-GAG matrix induced by TGF-beta1 and the decrease in contraction resulting from PDGF-BB treatment, indicating a causal relationship between expression of SMA and the contractility of the cells. A novel cell force monitor, employed to estimate the force exerted per cell, demonstrated a higher force exerted by the TGF-beta1-treated cells. The findings demonstrate that the expression of SMA by articular chondrocytes and meniscal cells and their associated contractile behavior can be regulated by selected growth factors. This work provides a foundation for the rational investigation of the mechanisms underlying SMA-enabled contraction of these cell types and the control of this behavior in tissue engineering.

Actins↗

Micromechanics of fibroblast contraction of a collagen-GAG matrix.

The contractile force developed by fibroblasts has been studied by measuring the macroscopic contraction of porous collagen-GAG matrices over time. We have identified the microscopic deformations developed by individual fibroblasts which lead to the observed macroscopic matrix contraction. Observation of live cells attached to the matrix revealed that matrix deformation occurred as a result of cell elongation. The time dependence of the increase in average fibroblast aspect ratio over time corresponded with macroscopic matrix contraction, further linking cell elongation and matrix contraction. The time dependence of average fibroblast aspect ratio and macroscopic matrix contraction was found to be the result of the stochastic nature of cell elongation initiation and of the time required for cells to reach a final morphology (2-4 h). The proposed micromechanics associated with observed buckling or bending of individual struts of the matrix by cells may, in part, explain the observation of a force plateau during macroscopic contraction. These findings indicate that the macroscopic matrix contraction measured immediately following cell attachment is related to the extracellular force necessary to support cell elongation, and that macroscopic time dependence is not directly related to microscopic deformation events.

Animals↗

Fibroblast contraction of a collagen-GAG matrix.

Contractile cells, found in wounded or diseased tissues, are associated with the formation of scar tissue. The complexity of contraction in vivo has led to the development of models of contraction by cells in vitro. In this work, a device was developed which quantitatively measured the contractile force developed by fibroblasts seeded into a collagen-glycosaminoglycan porous matrix in vitro. This device differed from most of those previously described in that it directly transferred cellular contractile force to the force transducer (a cantilever beam) and that it used a porous matrix rather than a collagen gel. The data for the increase in contractile force with time were fit to a mathematical equation using two fitting parameters. Data were then compared using the fitting parameters and the cell density. A study of the effect of cell density on the contractile force resulted in a linearly proportional relationship. Subsequent normalization of force by cell density or number resulted in a value of contractile force per cell, 1 nN, that was independent of cell density. The time for the contractile force to develop was also independent of cell density. These results suggest that, in this system, cells develop contractile force individually, irrespective of the force generated by surrounding cells.

Actins↗

Modeling modulus reduction in bovine trabecular bone damaged in compression.

Loading bone beyond its yield point creates microdamage, leading to reduction in stiffness. Previously, we related microdamage accumulation to changes in mechanical properties. Here, we develop a model that predicts stiffness loss based on the presence of microdamage. Modeling is done at three levels: (1) a single trabecula, (2) a cellular solid consisting of intact, damaged, and fractured trabeculae, and (3) a specimen with a localized damage band. Predictions of a reduced modulus agree well with experimental measured modulus reductions of post-yield compression of bovine trabecular bone. The predicted reduced modulus is relatively insensitive to changes in the input parameters.

Animals↗

Sequential labelling of microdamage in bone using chelating agents.

Basic fuchsin labels microcracks, but a series of stains is required to differentiate between preexisting and test-induced microcracks and to label their growth in vitro. Basic fuchsin and five chelating agents-alizarin complexone, calcein, calcein blue, oxytetracycline, and xylenol orange-were randomly assigned to label microcracks in sequential rib sections from 10 donors. The density, length, and location of the microcracks did not differ significantly between the six stains, suggesting that each was equally effective in detecting microcracks. Paired specimens of trabecular bone were machined from bovine tibiae, stained with oxytetracycline, and fatigued in compression. One specimen from each pair was then stained with xylenol orange. Preexisting microdamage was stained with oxytetracycline, propagating microcracks with both stains and new, test-initiated damage with xylenol orange. Chelating agents are site-specific markers of the initiation and growth of microcracks.

Bone and Bones↗

A cellular solid model for modulus reduction due to resorption of trabeculae in bone.

In osteoporotic trabecular bone, bone loss occurs by thinning and subsequent resorption of the trabeculae. In this study, we compare the effects of density reductions from uniform thinning of struts or from removal of struts in a random, open-cell, three-dimensional Voronoi structure. The results of this study, combined with those previous studies on other regular and random structures, suggest that the modulus and strength of trabecular bone are reduced more dramatically by density losses from resorption of trabeculae than by those from uniform thinning of trabeculae.

Aged↗

Results from demineralized bone creep tests suggest that collagen is responsible for the creep behavior of bone.

Cortical and trabecular bone have similar creep behaviors that have been described by power-law relationships, with increases in temperature resulting in faster creep damage accumulation according to the usual Arrhenius (damage rate approximately exp (-Temp.-1)) relationship. In an attempt to determine the phase (collagen or hydroxyapatite) responsible for these similar creep behaviors, we investigated the creep behavior of demineralized cortical bone, recognizing that the organic (i.e., demineralized) matrix of both cortical and trabecular bone is composed primarily of type I collagen. We prepared waisted specimens of bovine cortical bone and demineralized them according to an established protocol. Creep tests were conducted on 18 specimens at various normalized stresses sigma/E0 and temperatures using a noninvasive optical technique to measure strain. Denaturation tests were also conducted to investigate the effect of temperature on the structure of demineralized bone. The creep behavior was characterized by the three classical stages of decreasing, constant, and increasing creep rates at all applied normalized stresses and temperatures. Strong (r2 > 0.79) and significant (p < 0.01) power-law relationships were found between the damage accumulation parameters (steady-state creep rate d epsilon/dt and time-to-failure tf) and the applied normalized stress sigma/E0. The creep behavior was also a function of temperature, following an Arrhenius creep relationship with an activation energy Q = 113 kJ/mole, within the range of activation energies for cortical (44 kJ/mole) and trabecular (136 kJ/mole) bone. The denaturation behavior was characterized by axial shrinkage at temperatures greater than approximately 56 degrees C. Lastly an analysis of covariance (ANCOVA) of our demineralized cortical bone regressions with those found in the literature for cortical and trabecular bone indicates than all three tissues creep with the same power-law exponents. These similar creep activation energies and exponents suggest that collagen is the phase responsible for creep in bone.

Analysis of Variance↗

Creep contributes to the fatigue behavior of bovine trabecular bone.

Repetitive, low-intensity loading from normal daily activities can generate fatigue damage in trabecular bone, a potential cause of spontaneous fractures of the hip and spine. Finite element models of trabecular bone (Guo et al., 1994) suggest that both creep and slow crack growth contribute to fatigue failure. In an effort to characterize these damage mechanisms experimentally, we conducted fatigue and creep tests on 85 waisted specimens of trabecular bone obtained from 76 bovine proximal tibiae. All applied stresses were normalized by the previously measured specimen modulus. Fatigue tests were conducted at room temperature; creep tests were conducted at 4, 15, 25, 37, 45, and 53 degrees C in a custom-designed apparatus. The fatigue behavior was characterized by decreasing modulus and increasing hysteresis prior to failure. The hysteresis loops progressively displaced along the strain axis, indicating that creep was also involved in the fatigue process. The creep behavior was characterized by the three classical stages of decreasing, constant, and increasing creep rates. Strong and highly significant power-law relationships were found between cycles-to-failure, time-to-failure, steady-state creep rate, and the applied loads. Creep analyses of the fatigue hysteresis loops also generated strong and highly significant power law relationships for time-to-failure and steady-state creep rate. Lastly, the products of creep rate and time-to-failure were constant for both the fatigue and creep tests and were equal to the measured failure strains, suggesting that creep plays a fundamental role in the fatigue behavior of trabecular bone. Additional analysis of the fatigue strain data suggests that creep and slow crack growth are not separate processes that dominate at high and low loads, respectively, but are present throughout all stages of fatigue.

Animals↗

Modeling the mechanical behavior of vertebral trabecular bone: effects of age-related changes in microstructure.

Age-related reductions in the thickness and number of trabeculae in vertebral trabecular bone have been documented by several workers, yet the relative effects of these changes on mechanical properties are not known. We developed a two-dimensional model of human vertebral trabecular bone and investigated its mechanical behavior using finite element analysis. The stress-strain behavior, failure mode, and strain distributions predicted using the model were consistent with those observed for vertebral trabecular bone under compressive loading. Random reductions in the number of trabeculae reduced the modulus and strength of the models two to five times more than uniform reductions in the thickness of trabeculae that caused the same loss of bone volume. For example, randomly removing longitudinal trabeculae to achieve a reduction in density of 10% reduced the strength by approximately 70%, whereas removing the same amount of bone by uniformly reducing the thickness of the longitudinal trabeculae only reduced the strength by approximately 20%. For a simulation of aged bone, in which the thickness and number of trabeculae were reduced concurrently, the strength was 23% of its intact ("young") value. When the bone mass of the aged model was restored to its intact level by increasing the thickness but not the number of trabeculae, the strength increased by 60%, but was still only 37% of its intact value. These combined findings, based on a two-dimensional, idealized model of vertebral trabecular bone, illustrate the importance of maintaining trabecular number and suggest that it may not be possible to restore bone strength following a period of advanced bone loss if a substantial number of trabeculae have been resorbed. Thus, until treatments exist that can increase trabecular number, the most effective treatment strategy is to prevent the degradation of bone strength by maintaining the number of trabeculae at a healthy level.

Aged↗

Age-related differences in post-yield damage in human cortical bone. Experiment and model.

Very few quantitative comparisons between mechanical test behavior of cortical bone and microscopic evidence of damage have been reported. In this study, the hypothesis that age-related degradation of mechanical properties in human cortical bone is associated with increases in damage in the form of microcracks was investigated. The initial modulus and yield stress were 6% (not significant) and 10% (p = 0.05) lower, respectively, in specimens from elderly femora than in specimens from young adult femora. However, both groups showed a 34% decrease in modulus after being loaded to 1% strain. Microcracks were observed in cement lines and between lamellae and were parallel to the loading direction. There were 50% more cracks in longitudinal sections of tested specimens than in controls from elderly femora; however, there were no more cracks in tested specimens than in controls from young adult femora. In addition, there were twice as many cracks in controls and three times as many cracks in tested specimens from elderly femora than in those from young adult femora (p < 0.01). A microstructurally based model was developed which supported the mechanical test results and indicated that damage began to develop at about 1500 mu epsilon. The results suggest that older bone may have reduced mechanical properties due to the presence of more microcracks, and that older bone is more susceptible to developing microcracks at a given strain level. However, the mechanical test data indicate that specimens from young adult femora also sustained some king of damage as a result of mechanical loading, which requires further investigation.

Adult↗