PubMed Health⌕ Search

Biomedical subjects

L J Han

Publications and source records attributed to L J Han.

5 recordsLinked to original sources

[A study on physical characteristics of porous plates for water sublimator].

Objective. To investigate the development method of porous plate, the key part of water sublimator, and its main physical characteristics. Method. Technical parameters of porous plates used in water sublimator were analyzed. On the basis of this, porous plates made of different materials were developed by making use of sintered powder technology. A tester for testing the physical characteristics of porous plate was designed. All around physical characteristic tests for porous plates were conducted. Result. Main factors affecting performance of porous plates were tested. These provided basis for performance test of sublimator, established porous plate criterion and optimized porous plate. Conclusion. Porous plates developed by making use of sintered powder technology could meet requirements of performance of water sublimator.

Life Support Systems↗

[Determination of carfentrazone-ethyl(F8426) residue in soil and wheat by wide-bore capillary gas chromatography].

An efficient method for determining F8426 of Affinity 40 DF in soil and wheat is described. F8426 was extracted from the soil and the wheat sample with acetone-water (80:20, volume ratio), and the extract was partitioned with petroleum ether. Then the upper layer was concentrated and cleaned up on a micro-column of Florisil and activated carbon mixture. Finally F8426 was separated from other interfering components through wide-bore capillary gas chromatographic column (OV-1701, 12 m x 0.53 mm i.d.), and was detected by electron capture detector (ECD). The lowest detection limit for F8426 was 0.02 ng. The lowest detectable concentrations in wheat and soil was 2 micrograms/kg and 1 microgram/kg respectively. The average recovery and coefficient of variation of this method were 89.60%-97.53% and 4.42%-8.67% respectively. This method is simple, sensitive and suitable for residue analysis of F8426.

Chromatography, Gas↗

Comparison of bone single-photon emission tomography and planar imaging in the detection of vertebral metastases in patients with back pain.

Bone scan has long been considered to be an important diagnostic test in searching for bone metastases. However, considerable difficulty is encountered in the vertebral region due to the complexity of structures and the fact that other benign lesions, especially degenerative changes, are very common there. Single-photon emission tomography (SPET) has been reported to be useful in the differentiation of benign from malignant conditions. Here we report our experience with bone SPET in the diagnosis of vertebral metastases. This is a retrospective study of technetium-99m methylene diphosphonate (MDP) bone scans in 174 consecutive patients who were referred for the investigation of back pain in our department. MDP planar and SPET images were obtained. Of teh 174 patients, 98 had a known history of malignant tumours. The diagnosis of vertebral metastasis was made on the basis of the patients' clinical histories and the findings with other imaging techniques such as magnetic resonance imaging, computed tomography or follow-up bone scan. We found that the presence of pedicle involvement as seen on SPET was an accurate diagnostic criterion of vertebral metastasis. SPET had a sensitivity of 87%, a specificity of 91%, a positive predictive value of 82%, a negative predictive value of 94% and an accuracy of 90%. On the other hand, planar study had a sensitivity of 74%, a specificity of 81%, a positive predictive value of 64%, a negative predictive value of 88% and an accuracy of 79% in diagnosing vertebral metastasis. Except with regard to the negative predictive value, SPET performed statistically better than planar imaging. Only 9/147 (6.4%) lesions involving the vertebral body alone and 3/49 (6.1%) lesions involving facet joints alone were subsequently found to be metastases. We conclude that bone SPET is an accurate diagnostic test for the detection of vertebral metastases and is superior to planar imaging in this respect.

Aged↗

Transduction of human renal carcinoma cells with human gamma-interferon gene via retroviral vector.

We used a retroviral vector containing a human gamma-interferon (gamma-IFN) gene to transduce 13 renal carcinoma cell lines. The transduction efficiencies ranged from 0% to 60%, as determined by using an analogous vector containing the LacZ marker gene. In addition, gene-transferred resistance to the antibiotic neomycin was used to select for transduced cells. Nine of 13 lines were successfully transduced. Transduction was associated with the morphologic change of elongation, and there was a marked decrease in cell growth rate. Transduced cells secreted varying amounts (20-1076 pg/10(6) cells/d) of gamma-IFN as measured by enzyme-linked immunosorbent assay for at least 2 to 3 weeks after transduction (including 1 day of transduction, 6-7 days of selection, and an additional 8-12 days before the first passage of the transduced cells). Human leukocyte antigen (HLA) class II expression was markedly increased in six of seven cell lines; HLA class I expression was significantly increased in two of eight lines. Transduced cells that were subjected to cryopreservation after irradiation still produced gamma-IFN and expressed HLA class I and II antigens, although generally at lower levels than before these manipulations. This study confirms that retroviral vector transduction of the human gamma-IFN gene into renal carcinoma cells is feasible and associated with persistent production of gamma-IFN and increased expression of HLA class I and II molecules, and these effects are retained after irradiation and cryopreservation. This suggests that an autologous tumor cell vaccine trial with irradiated gamma-IFN gene-transduced renal carcinoma cell is rationale and feasible.

Carcinoma, Renal Cell↗