PubMed Health⌕ Search

Biomedical subjects

L J van Ruijven

Publications and source records attributed to L J van Ruijven.

At least 19 recordsLinked to original sources

Degree and distribution of mineralization in the human mandibular condyle.

The degree of mineralization of bone (DMB) in the mandibular condyle reflects the age and remodeling rate of the bone tissue. Quantification of DMB facilitates a better understanding of possible effects of adaptive remodeling on mineralization of the condyle and its possible consequences for its mechanical quality. We hypothesized differences in the degree and distribution of mineralization between trabecular and cortical bone and between various cortical regions. Microcomputed tomography was used to measure mineralization in 10 human mandibular condyles. Mean DMB was higher in cortical (1,045 mg hydroxyapatite/cm(3)) than in trabecular bone (857 mg/cm(3)) and differed significantly between cortical regions (anterior 987 mg/cm(3), posterior 1,028 mg/cm(3), subchondral 1,120 mg/cm(3)). The variation of DMB distribution was significantly larger in the anterior cortex than in the posterior and subchondral cortex, indicating a larger amount of heterogeneity of mineralization anteriorly. Within the cortical bone, DMB increased with the distance from the cortical canals to the periphery. Similarly, the DMB of trabecular bone increased with the distance from the surface of the trabeculae to their cores. It was concluded that the rate of remodeling differs between condylar trabecular and cortical bone and between cortical regions and that DMB is not randomly distributed across the bone. The difference in DMB between condylar cortical and trabecular bone suggests a large difference in Young's modulus.

Adult↗

Variations in mineralization affect the stress and strain distributions in cortical and trabecular bone.

The mechanical properties of bone depend largely on its degree and distribution of mineralization. The present study analyzes the effect of an inhomogeneous distribution of mineralization on the stress and strain distributions in the human mandibular condyle during static clenching. A condyle was scanned with a micro-CT scanner to create a finite element model. For every voxel the degree of mineralization (DMB) was determined from the micro-CT scan. The Young's moduli of the elements were calculated from the DMB using constant, linear, and cubic relations, respectively. Stresses, strains, and displacements in cortical and trabecular bone, as well as the condylar deformation (extension along the antero-posterion axis) and compliance were compared. Over 90% of the bone mineral was located in the cortical bone. The DMB showed large variations in both cortical bone (mean: 884, SD: 111 mg/cm(3)) and trabecular bone (mean: 738, SD: 101 mg/cm(3)). Variations of the stresses and the strains were small in cortical bone, but large in trabecular bone. In the cortical bone an inhomogeneous mineral distribution increased the stresses and the strains. In the trabecular bone, however, it decreased the stresses and increased the strains. Furthermore, the condylar compliance remained relatively constant, but the condylar deformation doubled. It was concluded that neglect of the inhomogeneity of the mineral distribution results in a large underestimation of the stresses and strains of possibly more than 50%. The stiffness of trabecular bone strongly influences the condylar deformation. Vice versa, the condylar deformation largely determines the magnitude of the strains in the trabecular bone.

Anisotropy↗

Structural and mechanical properties of mandibular condylar bone.

The trabecular bone of the mandibular condyle is structurally anisotropic and heterogeneous. We hypothesized that its apparent elastic moduli are also anisotropic and heterogeneous, and depend on trabecular density and orientation. Eleven condyles were scanned with a micro-CT system. Volumes of interest were selected for the construction of finite element models. We simulated compressive and shear tests to determine the principal mechanical directions and the apparent elastic moduli. Compressive moduli were relatively large in directions acting in the sagittal plane, and small in the mediolateral direction. The degree of mechanical anisotropy ranged from 4.7 to 10.8. Shear moduli were largest in the sagittal plane and smallest in the transverse plane. The magnitudes of the moduli varied with the condylar region and were proportional to the bone volume fraction. Furthermore, principal mechanical direction correlated significantly with principal structural direction. It was concluded that variation in trabecular structure coincides with variation in apparent mechanical properties.

Aged↗

A sensitive method for measuring spatial orientation in bone structures.

OBJECTIVES: This article introduces the newly developed line frequency deviation (LFD) method for measuring the orientation of the trabecular structure and shows that it is more sensitive than the mean intercept length (MIL) method that is commonly used. METHODS: The LFD method, which has been developed to measure the orientation of bone on two-dimensional X-ray images, was expanded to handle three-dimensional shapes. For the purpose of comparison, both the LFD and the MIL methods were applied to micro CT scans of 24 trabecular bone samples as well as to 24 simple synthetic samples. LFD and MIL values were calculated in various directions and collected in polar plots. Next, the anisotropy was quantified by calculating the coefficient of variation as well as by fitting ellipsoids through the plots. RESULTS: The MIL method yielded smooth rather spherical ellipsoidal polar plots with almost no sensitivity for changes in structure. The LFD method yielded more slender polar plots and more sensitivity for geometrical changes. The LFD method yielded significantly more anistropy and larger variation in anisotropy. CONCLUSIONS: The LFD method is a more sensitive descriptor of spatial orientation of bone structures than the MIL method.

Anisotropy↗

The effect of bone loss on rod-like and plate-like trabeculae in the cancellous bone of the mandibular condyle.

Bone loss may affect the structure of cancellous bone. But its effect on trabeculae with different characteristics, like rods and plates, is not accurately known. This study analyzes the effect of bone loss on individual rod-like and plate-like trabeculae. 94 specimens were obtained from mandibular condyles from both dentate and edentate humans and scanned with a micro-CT scanner. The bone volume fraction (BV/TV) of these specimens ranged from 7% to 30%. Next, the rod-like and plate-like trabeculae were identified with an especially developed algorithm. Plate volume fraction (PV/TV), rod volume fraction (RV/TV), plate thickness, rod thickness, number of plates, and number of rods were determined. In individual specimens, the thickness of the rods ranged from 40 mum to 180 mum, while the thickness of the plates ranged from 40 mum to 300 mum. In every specimen, the thickness of the plates was larger than the thickness of the rods. Statistical analysis revealed that PV/TV was proportional (r = 0.98, P < 0.001) and RV/TV inversely proportional (r = -0.45, P < 0.001) to BV/TV. Also the thickness of the plates correlated with BV/TV (r = 0.62, P < 0.001), while the thickness of the rods (mean = 90 mum, SD = 7 mum) remained constant (r = -0.09, P = 0.378). A four-fold reduction of the bone volume fraction was accompanied by a three-fold reduction of the number of plates and a 40% reduction of their thickness, but also by a three-fold increase in the number of rods and RV/TV. It was concluded that the effect of bone loss on plate-like trabeculae was opposite to its effect on rod-like trabeculae. Remarkably, the thickness of the rods (90 mum) was independent of the bone volume fraction. This suggests that there is a minimal thickness for trabeculae.

Aged↗

Bone tissue stiffness in the mandibular condyle is dependent on the direction and density of the cancellous structure.

Variation in the apparent stiffness of cancellous bone is generally ascribed to variation in cancellous structure and density, while the bone tissue stiffness is assumed to be constant. The purpose of the present study was to examine whether the bone tissue stiffness is dependent on the direction and density of the cancellous structure. Bone tissue stiffness was estimated by combining mechanical testing and micro-finite element (micro-FE) modeling on cylindrical bone specimens obtained from the human mandibular condyle. One set of specimens was tested in the vertical direction of the condyle (n = 39) and another set in the transverse direction (n = 30). The cancellous structure of the specimens was characterized by micro-CT. The apparent bone stiffnesses predicted by the FE model correlated strongly (r2 = 0.91) with the measured apparent bone stiffnesses. Apparent bone stiffness in the transverse direction was considerably smaller than that in the vertical direction. In contrast, the predicted bone tissue stiffness was significantly larger in the transverse direction (E = 13.70 GPa) than in the vertical direction (E = 11.87 GPa). In addition, bone tissue stiffness correlated negatively with the bone volume fraction and directional sensitivity of the bone tissue stiffness increased with a decrease of bone volume fraction. The results suggest that the transversely oriented trabeculae in the mandibular condyle are stiffer and more mineralized than the vertically oriented trabeculae and that bone loss is compensated by an increase in the degree of mineralization.

Aged↗

The influence of specimen attachment and dimension on microtensile strength.

The higher microtensile bond strength values found for specimens with a smaller cross-sectional area are often explained by the lower occurrence of internal defects and surface flaws. We hypothesized that this aberrant behavior is mainly caused by the lateral way of attachment of the specimens to the testing device, which makes the strength dependent on the thickness. This study showed that composite bars of 1x1x10, 1x2x10, and 1x3x10mm attached at their 1-mm-wide side (situation A) fractured at loads of the same magnitude, as a result of which the microtensile strength ( micro TS), calculated as F/A (force at fracture/cross-sectional area), significantly increased for specimens with decreasing thickness. Attachment at the 1-, 2-, or 3-mm-wide side (situation B) resulted in equal micro TS values (P > 0.05). Finite element analysis showed different stress patterns for situation A, but comparable patterns for situation B. Both situations showed the same maximum stress at fracture.

Analysis of Variance↗

Prediction of mechanical properties of the cancellous bone of the mandibular condyle.

The mechanical properties of cancellous bone depend on the bone structure. The present study examined the extent to which the apparent stiffness of the cancellous bone of the human mandibular condyle can be predicted from its structure. Two models were compared. The first, a structure model, used structural parameters such as bone volume fraction and anisotropy to estimate the apparent stiffness. The second was a finite element model (FEM) of the cancellous bone. The bone structure was characterized by micro-computed tomography. The calculated stiffnesses of 24 bone samples were compared with measured stiffnesses. Both models could predict 89% of the variation in the measured stiffnesses. From the stiffness approximated by FEM in combination with the measured stiffness, the stiffness of the bone tissue was estimated to be 11.1 +/- 3.2 GPa. It was concluded that both models could predict the stiffness of cancellous bone with adequate accuracy.

Aged↗

A telemetry system to chronically record muscle activity in middle-sized animals.

Radio-telemetry enables the long-term recordings of biopotentials that may be obtained in freely moving animals without interference by the experimenter. The purpose of this study was to test a fully implantable device for: (1) its transmission range; (2) the characteristics of the transmitted signals; and (3) its actual application in long-term in vivo registration of EMG. Transmission range was tested by changing the device's position relative to the receiver. Computer simulation of the filtering characteristics provided comparison of original and transmitted signals. Implantation of the device in masticatory muscles, followed by analysis of telemetred signals and determination of activity levels allowed for examination of daily muscle use. The implant's transmission range covered the cage size for middle-sized animals with a minimum of signal dropouts. Transmitted signals were marked by (partial) loss of frequencies beyond 50 Hz, decreased amplitude and slightly delayed timing relative to original waveforms. Analysis of the transmitted EMG revealed that the device can be used for prolonged in vivo EMG registration, detection of peak activity levels, and the examination of general muscle use by the time spent at different levels of activity.

Animals↗

Passive force characteristics of an architecturally complex muscle.

In architecturally complex muscles with large attachment areas, it can be expected that during movement different muscle regions undergo different amounts of length excursions. As a consequence, the amount of passive force produced by the regions will differ. Therefore, we tested the hypothesis that during movement the vector of the passive force of such a muscle, which defines the magnitude, position and orientation of the resultant force of the various regions, has no fixed position, between the muscle's center of origin and insertion. As a model for an architecturally complex muscle we used the masseter muscle. It was expected that during jaw opening anterior muscle regions are more stretched than posterior regions, leading to an anterior shift of the passive force vector. A three-component force transducer was used to measure both the position and magnitude of passive force in the masseter muscle of 9 rabbits. Forces were recorded during repeated cycles of stepwise opening and closure of the jaw. The muscle exhibited a clear hysteresis: passive force measured during jaw opening was larger than that during jaw closing. With an increase of the jaw gape there was an approximately exponential increase of the magnitude of the passive muscle force, while simultaneously the passive force vector shifted anteriorly. Moment arm length of passive force increased by about 100%. This anterior shift contributed substantially to the increase of the passive muscle moment generated during jaw opening. It can be concluded that in architecturally complex muscles the increase of the passive resistance moment which is associated with muscle lengthening might not only be due to an increase of the magnitude of passive muscle force but also to an increase of the moment arm of this force.

Animals↗

Mechanical significance of the trabecular microstructure of the human mandibular condyle.

The human mandibular condyle has a parasagittal plate-like trabecular structure. We tested the hypothesis that this structure reflects the mechanical loading of the condyle. We developed a finite element model of the condyle to analyze the strains occurring during static compressive loading. The principal strains in the trabecular bone were primarily oriented in the sagittal plane. The first component was compressive and oriented supero-inferiorly. The second component was negligibly small and oriented medio-laterally. The third component was tensile, oriented antero-posteriorly, and almost equal to the compressive strain. This tensile strain was caused by antero-posterior bulging of the cortex. This means that the trabecular structure is also subjected to significant tensile forces. The orientation of the parasagittal strains followed the direction of the applied load. It was concluded that the trabecular structure of the mandibular condyle is optimal in resisting the compressive and tensile strains to which it is subjected.

Biomechanical Phenomena↗

Three-dimensional finite element analysis of the cartilaginous structures in the human temporomandibular joint.

While the movability of the human temporomandibular joint is great, the strains and stresses in the cartilaginous structures might largely depend on the position of the mandible with respect to the skull. This hypothesis was investigated by means of static three-dimensional finite element simulations involving different habitual condylar positions. Furthermore, the influence of several model parameters was examined by sensitivity analyses. The results indicated that the disc moved together with the condyle in the anterior direction without the presence of ligaments and the lateral pterygoid muscle. By adapting its shape to the changing geometry of the articular surfaces, the disc prevented small contact areas and thus local peak loading. In a jaw-closed configuration, the influence of 30 degrees variations of the loading direction was negligible. The load distribution capability of the disc appeared to be proportional to its elasticity and was enhanced by the fibrocartilage layers on the articular surfaces.

Aged↗

Three-dimensional finite element analysis of the human temporomandibular joint disc.

A three-dimensional finite element model of the articular disc of the human temporomandibular joint has been developed. The geometry of the articular cartilage and articular disc surfaces in the joint was measured using a magnetic tracking device. First, polynomial functions were fitted through the coordinates of these scattered measurements. Next, the polynomial description was transformed into a triangulated description to allow application of an automatic mesher. Finally, a finite element mesh of the articular disc was created by filling the geometry with tetrahedral elements. The articulating surfaces of the mandible and skull were modeled by quadrilateral patches. The finite element mesh and the patches were combined to create a three-dimensional model in which unrestricted sliding of the disc between the articulating surfaces was allowed. Simulation of statical joint loading at the closed jaw position predicted that the stress and strain distributions were located primarily in the intermediate zone of the articular disc with the highest values in the lateral part. Furthermore, it was predicted that considerable deformations occurred for relatively small joint loads and that relatively large variations in the direction of joint loading had little influence on the distribution of the deformations.

Aged↗

The accuracy of joint surface models constructed from data obtained with an electromagnetic tracking device.

Electromagnetic tracking devices are widely used in biomechanics. In this article a method is evaluated to construct models of articular surfaces using an electromagnetic tracking device. First, the accuracy of the space tracker was examined and optimised. Then, from several joint surfaces random points were measured and eighth degree polynomials were fitted to these measurements. To check if the fit converged well, plots of cross sections of the model with corresponding data points were examined. The accuracy of the models was determined by comparing them with computed tomography data and by reproducibility tests. All the fits converged well to the data. The root mean square (RMS) error of the models varied from 0.07 to 0. 18mm, and was proportional to the size and complexity of the surface. This was mainly due to systematic errors made by the space tracker, which were also proportional to the size and complexity of the surface.

Biomechanical Phenomena↗

Motor coordination in a multi-muscle system as revealed by principal components analysis of electromyographic variation.

The variation in electromyographic output of twelve trigeminal muscles of the rabbit was studied to test the hypothesis that they are under the control of a small number of independent neural factors. Jaw muscle electromyograms (EMGs) of eight animals were recorded in 95 chewing sequences, each consisting of 40-75 chewing cycles. The within-sequence correlations of the EMG burst amplitudes (integrated per cycle) and burst onsets were calculated between the muscles. The correlation matrix was subjected to a principal components analysis. This method aims at describing the variation in EMG amplitude and timing by means of the smallest possible set of newly defined variables, or principal components. Of the variation in EMG amplitude values of the twelve muscles, 75-90% could be accounted for by only three principal components. Each principal component was characterized by a group of muscles with high mutual positive correlations; they had zero correlation with other principal components. The first component represents the jaw closers: most of the bilateral masseter and the medial pterygoid muscles. The second represents the openers: the bilateral digastric and lateral pterygoid muscles. This demonstrates the tight control of both the jaw openers and closers, each by a single neural factor; these two factors are independent of one another. They most likely originate from the specific inputs from primary afferents to the opener and closer motoneurons. Unexpectedly, a third independent principal component appeared to control the closing activity of the non-chewing side, posterior deep masseter muscle. It was hypothesized that this muscle acts independently of the other closers to disengage the teeth and resets the jaw for a new chewing cycle. Principal components analysis of variation in timing of EMG onset revealed a grouping of all masticatory muscles in a single cluster, independent of EMG amplitude. This supports the hypothesis that timing and amplitude of masticatory EMG patterns are controlled independently.

Animals↗

Fitting parametrized polynomials with scattered surface data.

Currently used joint-surface models require the measurements to be structured according to a grid. With the currently available tracking devices a large quantity of unstructured surface points can be measured in a relatively short time. In this paper a method is presented to fit polynomial functions to three-dimensional unstructured data points. To test the method spherical, cylindrical, parabolic, hyperbolic, exponential, logarithmic, and sellar surfaces with different undulations were used. The resulting polynomials were compared with the original shapes. The results show that even complex joint surfaces can be modelled with polynomial functions. In addition, the influence of noise and the number of data points was also analyzed. From a surface (diam: 20 mm) which is measured with a precision of 0.2 mm a model can be constructed with a precision of 0.02 mm.

Joints↗

Electromyographic heterogeneity in the human temporalis and masseter muscles during dynamic tasks guided by visual feedback.

The complex architecture of the human jaw muscles suggests regional differences in function within these muscles. This study examines the way the temporalis and masseter muscle regions are activated when free mandibular movements with various speeds and against various external leads are carried out guided by visual feedback. Electromyographic (EMG) activity was registered in six temporalis and three masseter muscle regions with bipolar fine-wire electrodes. Recordings were made during open/close excursions, protrusion/retrusion movements, and laterodeviations. During open/close excursions and protrusion/retrusion movements, an anterior and posterior temporalis part could be distinguished, whereas during laterodeviations a more complex partitioning of this muscle was observed. During the protrusion/retrusion movements and the laterodeviations, the temporalis muscle demonstrated higher EMG peak activities than the masseter muscle, and within the masseter muscle the deep masseter showed higher EMG peaks than the superficial one. In contrast to this, during the open/close excursions the masseter showed higher peak activities than the temporalis muscle, while the superficial masseter showed higher EMG peak activities than the deep masseter. Within the deep masseter, differences were also found. During open/close excursions, the anterior deep region demonstrated higher EMG peak activities than the posterior region, whereas during protrusion/retrusion and laterodeviations the posterior deep region showed higher peaks. In general, speed had a greater effect on the EMG peak activity than external load. Only during laterodeviations did speed and load equally influence peak activity in both the deep and superficial masseter. During protrusion/retrusion movements, load showed no significant effect on EMG peak activity in the masseter muscle. A general finding was that, according to task, different regions were activated preferentially. This points to a partitioning of the excitatory command of the motoneuron pool.

Adult↗

A new transducer system for direct motor unit force measurement.

A new transducer was developed for in situ measurement of the force vector in a complex muscle. The transducer measures the magnitude, and the line of action of a force in a single plane. The dynamic range of the transducer is 0-5 N. This range includes the small forces developed by an active motor unit and the relatively large passive force of a whole muscle. In this study we present the details of the transducer design and specifications, and describe its application in the measurement of motor unit forces of the rabbit masseter muscle.

Animals↗