PubMed Health⌕ Search

Biomedical subjects

L Jayaram

Publications and source records attributed to L Jayaram.

11 recordsLinked to original sources

Determining asthma treatment by monitoring sputum cell counts: effect on exacerbations.

One important goal of asthma treatment is to reduce exacerbations. The current authors investigated if the use of sputum cell counts to guide treatment would achieve this goal. A total of 117 adults with asthma were entered into a multicentre, randomised, parallel group-effectiveness study for two treatment strategies over a 2-yr period. In one strategy (the clinical strategy: CS) treatment was based on symptoms and spirometry. In the other (the sputum strategy: SS) sputum cell counts were used to guide corticosteroid therapy to keep eosinophils 250 microg, and was due to fewer eosinophilic exacerbations. The cumulative dose of corticosteroid during the trial was similar in both groups. Monitoring sputum cell counts was found to benefit patients with moderate-to-severe asthma by reducing the number of eosinophilic exacerbations and by reducing the severity of both eosinophilic and noneosinophilic exacerbations without increasing the total corticosteroid dose. It had no influence on the frequency of noneosinophilic exacerbations, which were the most common exacerbations.

Adult↗

Zinc and its specific transporters as potential targets in airway disease.

The dietary group IIb metal zinc (Zn) plays essential housekeeping roles in cellular metabolism and gene expression. It regulates a number of cellular processes including mitosis, apoptosis, secretion and signal transduction as well as critical events in physiological processes as diverse as insulin release, T cell cytokine production, wound healing, vision and neurotransmission. Critical to these processes are the mechanisms that regulate Zn homeostasis in cells and tissues. The proteins that control Zn uptake and compartmentalization are rapidly being identified and characterized. Recently, the first images of sub-cellular pools of Zn in airway epithelium have been obtained. This review discusses what we currently know about Zn in the airways, both in the normal and inflamed states, and then considers how we might target Zn metabolism by developing strategies to monitor and manipulate airway Zn levels in airway disease.

Absorption↗

Steroid naive eosinophilic asthma: anti-inflammatory effects of fluticasone and montelukast.

BACKGROUND: Inhaled corticosteroids and leukotriene receptor antagonists reduce airway eosinophilia and have been used as first line anti-inflammatory therapy for mild persistent asthma. METHODS: A multicentre, randomised, placebo controlled, parallel group study was performed to compare the anti-inflammatory effects of fluticasone propionate and montelukast as measured by sputum eosinophils in 50 adults with symptomatic steroid naive asthma and sputum eosinophilia of > or =3.5%. RESULTS: Eighteen patients received low dose fluticasone (250 mug/day), 19 received montelukast (10 mg/day), and 13 were given placebo for 8 weeks. Fluticasone treatment resulted in a greater reduction in sputum eosinophils (geometric mean (SD) 11.9 (2.3)% to 1.7 (5.1)%) than montelukast (10.7 (2.3)% to 6.9 (3.8)%; p = 0.04) or placebo (15.4 (2.4)% to 7.8 (4.2)%; p = 0.002), and improvement in FEV(1) (mean (SD) 2.6 (0.9) l to 3.0 (0.9) l) than montelukast (2.8 (0.7) l to 2.8 (0.9) l; p = 0.02) or placebo (2.4 (0.8) l to 2.4 (0.9) l; p = 0.01). Treatment with fluticasone suppressed sputum eosinophilia within a week while montelukast only attenuated it. The effect of montelukast was maximal at 1 week and was maintained over 4 weeks. The effect of fluticasone was maintained over 8 weeks while that of montelukast was not. CONCLUSIONS: Montelukast is not as effective as low dose fluticasone in reducing or maintaining an anti-inflammatory effect in steroid naive eosinophilic asthma.

Acetates↗

Failure of montelukast to reduce sputum eosinophilia in high-dose corticosteroid-dependent asthma.

Sputum eosinophilia is a sensitive predictor of benefit from corticosteroid treatment. Montelukast is a cysteinyl leukotriene antagonist, which also reduces sputum and blood eosinophils. The present study examined the possibility that montelukast has an added eosinophil-lowering effect in subjects with asthma who are corticosteroid responsive but relatively corticosteroid resistant. A total of 14 clinically stable adults with asthma requiring minimum treatment with a high-dose inhaled steroid or prednisone, with baseline sputum eosinophilia (> or =5%), were randomised to receive 4 weeks of 10 mg montelukast or placebo daily in a double-blind crossover trial. The primary outcome was the effect of treatment on the percentage of sputum eosinophils. Secondary outcomes were changes in the blood eosinophil count, symptoms, forced expiratory volume in one second, peak expiratory flow and the need for salbutamol. The median (interquartile range, i.e. 75th-25th centile) for sputum eosinophils at baseline was 15.7% (22). The effect of adding montelukast was not significantly different from that of placebo, sputum eosinophils being 9.3% (18.9) after montelukast and 11.3% (22.8) after placebo. No difference was detected on secondary outcomes. No crossover interactions were observed. In conclusion, the addition of montelukast to existing high-dose corticosteroid therapy in subjects with asthma with elevated sputum eosinophils does not provide additional attenuation of airway eosinophilia.

Acetates↗

Use of heated humidification during nasal CPAP titration in obstructive sleep apnoea syndrome.

Nasal symptoms associated with the use of nasal continuous positive airway pressure (nCPAP) in obstructive sleep apnoea (OSA) can adversely impact on patients' tolerance, acceptance and adherence to nCPAP therapy. Regular use of heated humidification is effective in alleviating these symptoms and improve patient comfort. In a randomised, parallel, double-blinded, controlled study, the present authors examined the use of heated humidification during a single night laboratory nCPAP titration in untreated OSA patients and its effect on nasal symptoms, nasal airway resistance (NAR), effective pressure and treatment tolerability and acceptance. Baseline characteristics of subjects (n=70) receiving placebo and humidification were (mean+/-sem): age 51.2+/-2.2 versus 50.6+/-1.6 yrs; body mass index 33.6+/-0.9 versus 35.2+/-0.9 kg.m-2; Epworth Sleepiness Scale 10.8+/-1.0 versus 11.3+/-0.7; and apnoea-hypopnoea index 43.5+/-4.6 versus 44.4+/-4.1 events.h-1. Total inspiratory NAR, before (0.36+/-0.09 (placebo) versus 0.33+/-0.09 kPa.L-1.s-1) and after nCPAP (0.47+/-0.11 versus 0.29+/-0.04 kPa.L-1.s-1) were not significantly different between the groups. No difference was found in the frequency and severity of nasopharyngeal symptoms, therapeutic pressure and subjective response to nCPAP. In conclusion, heated humidification during the initial nasal continuous positive airway pressure titration offers no additional benefit in nasal physiology, symptoms or subjective response to nasal continuous positive airway pressure, and, therefore, should not be routinely recommended.

Adult↗

Induced sputum: time from expectoration to processing.

One of the limitations in the use of induced sputum to measure indices of airway inflammation is the perceived need to process the sample within 2 h. Therefore, the authors investigated whether the processing of induced sputum could be delayed. Induced sputum samples obtained from asthmatic subjects (n=30) were examined. Each sample was stored at 4 degrees C. A portion was selected and processed within 2 h and the remaining expectorate (sputum plus saliva) was refrigerated. Later an equal amount was selected and processed at either 9 (n=15) or 18 (n=15) h. The sputum was examined for cell counts and viability, fluid-phase eosinophil cationic protein (ECP), interleukin-8 (IL-8) and fibrinogen. Repeatability of measurements was assessed by the interclass correlation coefficient (ICC). Measurements obtained at 9 h did not differ from those made at 2 h and the repeatability was excellent (ICC 0.88-0.99). However, by 18 h the median cell viability was reduced from 65.0% to 43.0% and the ICC was generally lower: 0.10 for total cell count, 0.24 for viability, 0.60 for neutrophils, 0.90 for eosinophils, 0.56 for macrophages, 0.76 for ECP, 0.82 for IL-8 and 0.84 for fibrinogen. The results indicate that when induced sputum from subjects with asthma is kept at 4 degrees C, examination of cell counts can be delayed for < or = 9 h and for the fluid-phase indices measured for < or = 18 h. Further investigation of this issue is required for spontaneous sputum, other airway diseases and other inflammatory markers.

Asthma↗

Induced sputum cell counts: their usefulness in clinical practice.

Airway inflammation is fundamental to the aetiology and persistence of asthma and other airway conditions. The presence and type of airway inflammation can be difficult to detect clinically, delaying the introduction of appropriate treatment. Induced sputum cell counts are a relatively noninvasive, safe and reliable method of identifying airway inflammation. They can accurately discriminate eosinophilic airway inflammation from noneosinophilic airway inflammation, and help guide therapy. Eosinophilic airway inflammation is steroid responsive whilst noneosinophilic (usually neutrophilic) inflammation generally is not. Macrophages containing haemosiderin can be useful in detecting left ventricular dysfunction and macrophages containing lipid are suggestive of oropharyngeal reflux with microaspiration, both of which can complicate or confuse assessment of airway disease. To date, studies using induced sputum are primarily observational. Management studies based on examination of induced sputum are now needed to validate the clinical utility of this test.

Cell Count↗

A survey of computer usage amongst Auckland general practitioners.

Auckland general practitioners were surveyed to assess their use of computers. Forty-eight practitioners (9.6%) had computers which were primarily used for practice administration. The main benefit offered by the computer was an improvement in quality of work rather than a reduction in quantity. Areas of dissatisfaction revealed by the survey included cost, limited flexibility, and the consequences of computer failure. Although most respondents suggested improvements in specific areas, many felt that the age of computerised general practice had arrived.

Adult↗