PubMed HealthSearch

Biomedical subjects

L K Gardner

Publications and source records attributed to L K Gardner.

At least 19 recordsLinked to original sources

Comparative implant research in dogs: a prosthodontic model.

One-hundred twenty endosteal dental implants were inserted bilaterally in the mandibles of 30 adult mongrel dogs after bilateral extraction of all premolars. The 120 implants were evenly divided into one- and two-stage systems and included ceramic and titanium cylindrical root-form implants and titanium blade implants. The research design of this investigation divided the 30 animals into 10 groups of three dogs. This article describes an animal model that is useful in evaluating dental implant designs and compares the results with those from humans. In particular, this article delineates the prosthodontic approach appropriate for this model using one- and two-stage titanium implants. Rexillium alloy fixed prostheses were placed on 32 endosteal implants and 16 natural mandibular molar teeth. The implants and prosthetic components of the Sterio-Oss implant system were used. All prostheses are functional with minimal maintenance. To date, after 1-year of follow-up, none of the implants have been lost and none of the fixed prostheses have required recementation or maintenance other than normal hygiene. Histologic and survival data as well as results with other implant systems will be presented in other reports.

Animals

The mandibular swing-lock complete denture for patients with microstomia.

Regardless of cause, the treatment of an edentulous patient with microstomia is difficult and often ingenious. Prosthodontic treatment modalities previously described are reviewed. A new type of prosthesis, the collapsible mandibular swing-lock complete denture, is introduced. The prosthesis incorporates a cast cobalt-chromium framework with a lingual hinge and a conventional labial swing-lock. This combination allows the prosthesis to be collapsible while maintaining structural durability. Advantages include ease of insertion and removal while providing maximum coverage for support, retention, and stability. A stepwise technique for the clinical and laboratory phases is described.

Dental Impression Technique

Simulated implant surgery in rabbit long bones: a descriptive study.

The objectives of this study were: (a) to observe and describe the variability of bone healing in implant receptor sites which were prepared in rabbit femurs by use of different surgical methods; and (b) to determine if the animal model which was used was suitable for the detection of differences in healing reactions in implant receptor sites which were prepared by different surgical methods. Three 3-mm-wide implant receptor sites were prepared in the right and left femurs of four large New Zealand white rabbits. The surgical parameters used in preparation of the different sites included: low speed with no irrigation (LSO); low speed with internal irrigation only (LSI); low speed with external irrigation only (LSE); high speed with no irrigation (HSO); or high speed with external irrigation only (HSE). The sites were randomized so that each animal had one of each type of site in either the right or left femur. A non-treated control site was located in each animal for comparison with experimental sites. The animals were killed at 7, 14, 21, and 28 days post-operatively. The resultant samples were fixed, embedded, sectioned, and stained with basic fuchsin and toluidine blue. The results indicated that this was probably not a suitable animal model, since no discernible differences were detected in the various healed sites.

Animals

Comparative implant research in dogs: prosthodontic protocol using two-stage ceramic endosseous dental implants.

This report describes one phase of a long-term comparative implant investigation involving 20 of 120 endosseous implants placed in 30 adult mongrel dogs. Fixed prostheses involving 16 of the 20 (4 control implants) two-stage ceramic endosseous implants have been provided using routine prosthodontic procedures and the limited prosthetic components available for the Bioceram Series II implant system. The prostheses have proven to be functional with minimal maintenance. To date, after 1 year of follow-up, 2 of the two-stage implants have exhibited problems caused by fracture of the hexagonal collar. None of the implants to date has been lost and none of the fixed prostheses has required re-cementation or any other type of maintenance other than normal hygiene. Clinical evaluation suggests continued implant and prosthesis serviceability after 1 year in function.

Aluminum Oxide

Film thickness of die coating agents.

Die coating agents are often used during the fabrication of porcelain margins for crowns and fixed partial dentures. These agents seal microscopic irregularities within the stone die and resist abrasion. This investigation measured the film thickness of several die coating agents. A specific reference point was used during the measurement process. The results indicate that there is no significant difference between the die coating agents examined under the conditions of the study. The film thickness measurements ranged between 0.367 microns for Duro Super Glue Material and 2.3 microns for Zap CA material.

Acrylic Resins

Using a tooth-reduction guide for modifying natural teeth.

A simplified method of transferring diagnostic odontoplastic information from the cast to the patient is described. This technique can be used successfully when treating fixed, removable, or combination prosthodontics patients.

Acrylic Resins

Extending the longevity of temporary soft liners with a mono-poly coating.

A method has been described that will reduce the incidence of fungal growth and increase the period of resiliency for temporary soft liners. The use of a monopoly coating procedure is limited to temporary soft liners only. The coating will not adhere to the more permanent soft liners such as Molloplast-B (Regneri & Co KG, Karlsruhe, West Germany). The coating, however, can be used on any conventional temporary soft liner with good results.

Biocompatible Materials