Fatigue analysis of the surface EMG signal in isometric constant force contractions using the averaged instantaneous frequency.

The averaged instantaneous frequency (AIF) is proposed as an alternative method for the frequency analysis of surface electromyography (EMG) in the study of muscle fatigue during sustained, isometric muscle contractions. Results from performance analysis using experimental EMG signals demonstrate the low variability of the proposed frequency variable. Indeed, the AIF measure is shown to perform significantly better than the widely used mean and median frequency variables, in terms of robustness to the length of the analysis window.

Action Potentials↗

Automatic algorithm for filtering kinematic signals with impacts in the Wigner representation.

An automatic filtering algorithm is proposed for the accurate estimation of the second derivatives of kinematic signals with impacts. The impacts considered here occur when a moving object hits a rigid surface. The algorithm performs time-frequency filtering in the Wigner representation, to deal efficiently with the non-stationarities caused by such impacts, and adjusts the parameters of its time-frequency filtering function so that the filtering process adapts to the individual characteristics of the signal in hand. Performance analysis and comparative evaluation with experimentally acquired kinematic impact signals demonstrated a higher accuracy, with performance advantages over two widely used conventional automatic methods: linear phase autoregressive model-based derivative assessment (LAMBDA) and generalised cross-validation using quintic splines (GCVQS). For high impacts, the average absolute relative error in estimating the peak acceleration was 5.7% with the proposed method, 17.2% with a Butterworth low-pass filter optimised to yield minimum overall acceleration RMS error (best-case result), 18.3% with the LAMBDA method, and 37.2% with the GCVQS method. For signals with low impacts, the average absolute relative error was 19.4%, 6.9%, 8.3% and 19.1%, respectively, in each case, which indicates that, for signals with a low-frequency content, there is no need for such time-frequency filtering.

Algorithms↗

Time-frequency analysis and filtering of kinematic signals with impacts using the Wigner function: accurate estimation of the second derivative.

Biomechanical signals are represented in the time-frequency domain using the Wigner distribution function. Filtering of this representation for the case of a non-stationary displacement signal with impact is studied. Smoothed displacement data are then double differentiated and compared with references accelerometer data. It is shown that this technique is able to remove noise from these signals in a better way than conventional filtering techniques currently used in biomechanics.