PubMed Health⌕ Search

Biomedical subjects

L Kinzl

Publications and source records attributed to L Kinzl.

At least 19 recordsLinked to original sources

Hip arthroplasty with proximal transmission of force: first clinical results with a new partially cemented femoral stem.

BACKGROUND: Proximal stem fixation by partial cementing is a new concept in hip arthroplasty. We conducted a prospective clinical and radiological analysis to evaluate the preliminary outcome of this new technique with the Option 3000 stem (Mathys Orthopaedics, Bettlach, Switzerland). METHODS AND FOCUS: One hundred and thirty-three hip replacements in 123 patients have been performed between 1996 and 2003: All of them were followed up regularly both clinically and radiological and 53 were analysed with the EBRA-FCA method. Eighty-six patients with 95 hips could be seen in August 2004. At this point of time, the mean follow-up time was 61 months (5.08 years) with a maximum of 100 months (8.33 years) RESULTS: The clinical data reported an average Harris Hip Score of 85.5. Nine stems had to be exchanged over the period of study. The EBRA-FCA analysis reported a mean subsidence less than 1.5 mm after 2 years, then an average stable subsidence of 2.4 mm. So the results are similar to the early results obtained with other fixation concepts and the long-term results appear promising.

Aged↗

[Osteitis. Infections of the locomotive system].

Infections of the locomotive system appear in many different forms such as acute inflammation of joints or bone following injury or surgical or chronic processes, often lasting for years. They demand an exact treatment plan not only to remove necrotic tissue but also for reconstruction of defects. A special problem is infection following alloplastic reconstruction of joints or spine. Multiple surgical procedures are required to hinder reinfection, restore function, and assure acceptable patient quality of life.

Arthritis, Infectious↗

[Emergency surgery for chest injuries in the multiply injured: a systematic review].

OBJECTIVE: Severe chest injuries are still associated with significant morbidity and mortality. This systematic review assesses the early operative management of severe chest trauma in multi injured patients with special regard to the priority of the operative therapy. METHODS: Clinical trials were systematically sought and collected (MEDLINE, Cochrane and hand searches). Of 618 abstracts, 46 articles were selected for detailed appraisal and were classified into evidence levels (1 to 5 according to the Oxford system). RESULTS: Penetrating chest injuries in haemodynamically instable patients require emergency operative therapy. A thoracotomy is also indicated in excessive chest tube output (>1500 ml). An aortic rupture can be treated either by open suture or-in borderline patients-by endovascular stenting. In selected haemodynamically stable patients delayed treatment is also possible. Lesions of the tracheobronchial system should be treated urgently with primary surgical repair. Diaphragmatic ruptures should be closed urgently. Surgical stabilisation of rib fractures with an associated flail chest reduces the ventilator days and the length of intensive care unit stay. CONCLUSION: A large part of early surgery for chest injuries is justified because it averts immediate threats to life (level 1c evidence). No randomised and only a few controlled trials have examined the relative value of the different surgical options so far. Long-term data are lacking especially on the safety of endovascular stenting.

Aortic Rupture↗

[Do injuries of the upper extremity in geriatric patients end up in helplessness? A prospective study for the outcome of distal radius and proximal humerus fractures in individuals over 65].

In a prospective study 104 patients >or=65 years with distal radius fractures (DRF; n=52) and proximal forearm fractures (PHF; n=52) were followed up for a period of 4 months after injury. As an inception- cohort study, influence on treatment pattern was not part of the examination. A total of 53% of the DRF and 74% of the PHF patients underwent surgery. There were no significant changes in the ability of daily living management (IADL) with either fracture form. Functional outcome was better in PHF than DRF patients. PHF patients showed a high incidence in "fear of falling" throughout the whole study, whereas fear of falling rose significantly in DRF patients. 4% of DRF and 9.6% of PHF patients died during the observation period, while 6% of DRF and even 17% of PHF patients had to give up their own housekeeping. One third of both patient groups did not receive physiotherapy. In only 12% of DRF and 6% of PHF patients was osteoporosis treated. In both groups of patients there was a significant worsening in the ability of walking after injury, leading to two or more new falls in 24% of DRF and 28% of PHF patients.

Accidental Falls↗

Intramuscular pressure, tissue oxygenation and EMG fatigue measured during isometric fatigue-inducing contraction of the multifidus muscle.

Simultaneous measurement of intramuscular pressure (IMP), tissue oxygen partial pressure (pO(2)) and EMG fatigue parameters in the multifidus muscle during a fatigue-inducing sustained muscular contraction. The study investigated the following hypotheses: (1) Increases in IMP result in tissue hypoxia; (2) Tissue hypoxia is responsible for loss of function in the musculature. The nutrient supply to muscle during muscle contraction is still not fully understood. It is assumed that muscle contraction causes increased tissue pressure resulting in compromised perfusion and tissue hypoxia. This tissue hypoxia, in turn, leads to muscle fatigue and therefore to loss of function. To the authors' knowledge, no study has addressed IMP, pO(2) and EMG fatigue parameters in the same muscle to gain a deeper sight into muscle perfusion during contraction. As back muscles need to have a constant muscular tension to maintain trunk stability during stance and locomotion, muscle fatigue due to prolonged contraction-induced hypoxia could be an explanation for low back pain. Sixteen healthy subjects performed an isometric muscular contraction exercise at 60% of maximum force until the point of localized muscular fatigue. During this exercise, the individual changes of IMP, pO(2) and the median frequency (MF) of the surface EMG signal of the multifidus muscle were recorded simultaneously. In 12 subjects with a documented increase in intramuscular pressure, only five showed a decrease in tissue oxygen partial pressure, while this parameter remained unchanged in six other subjects and even increased in one. A fall in tissue pO(2) was associated with a drop in MF in only five subjects, while there was no correlation between these parameters in the other 11 subjects. To summarize, an increase in IMP correlated with a decrease in pO(2) and a drop in MF in only five out of 16 subjects. High intramuscular pressure values are not always associated with a hypoxia in muscle tissue. Tissue hypoxia is not automatically associated with a median frequency shift in the EMG signal's power spectrum.

Adult↗

[Post-traumatic torsional differences and functional tests following antegrade or retrograde intramedullary nailing of the distal femoral diaphysis].

Previous studies have compared the functional outcome and torsional differences following closed intramedullary nailing of femoral fractures. Rotational deformity following intramedullary nailing may cause symptoms and require surgical correction by osteotomy. Until now studies were designed to evaluate the correct torsional differences by examining every patient following antegrade or retrograde femoral nailing. The series included 13 women and 28 men, average age 44.5 years, who suffered a fracture of the distal femoral diaphysis. Postoperatively we established the diagnosis by three-dimensional determination of the torsion and length of the lower extremities by ultrasound measurement. Furthermore, we performed the clinical examination according to the Tegner and Lysholm score and the Merle d'Aubigne score. There were no significant differences in torsional deformity and length found. The functional outcome showed no significant differences between the two groups. The functional examination exhibited a reduction of flexion in knee motion in the retrograde group. In the antegrade group the motion of the hip was decreased. A correlation between the functional outcome and the torsional deformity was not found. The possible advantage of positioning by using the retrograde femoral nail was not verified.

Adult↗

[Value of arthroscopy in the treatment of upper ankle arthritis].

OBJECTIVE: The purpose of this retrospective study was to evaluate arthroscopy in upper ankle osteoarthritis. METHODS: In the period from 1988 to 1997, 358 arthroscopies of the upper ankle joint were performed in 178 cases due to arthritis. Of 132 accessible patients, 124 replied to our questionnaire: 90 (73%) of the responders underwent clinical examination 94 (37-152) months following the initial arthroscopy and were graded according to the score of Evanski and Waugh. All arthroscopies were performed under fluid filling using anterolateral and anteromedial approaches. In only five cases was the posterior compartment additionally investigated. Generally, neither tourniquet nor mechanical joint distraction were applied. RESULTS: Of a total of 12 (6.7%) complications, only 3 (1.7%) hematomas needed surgical revision. One hematoma was due to an arteriovenous fistula treated by double ligation. All complications including five hypesthesias were temporary and subsided spontaneously. The 124 patients of the questionnaire group assessed the result of arthroscopic surgery as excellent in 11%, good in 46%, fair in 22%, and poor in 21%. Of all patients, 22% required further surgery of the upper ankle: in 9% further arthroscopy, in 3% arthrodesis, and in 10% microsurgical denervation. The total range of motion increased from 10/0/40 degrees (extension/flexion) preoperatively to 15/0/44 degrees at the follow-up examination. The Evanski score improved significantly (p<0.001) from 41 to 76 points. CONCLUSION: Due to minimal invasiveness and low risk of complications, arthroscopy is recommended for the following indications of upper ankle osteoarthritis: focal arthrosis, limited range of motion caused by osteophytes, soft tissue impingement, corpora libera, and synovitis. Severity and extent of upper ankle arthritis, range of motion, pain, local bone and soft tissue quality as well as the age, physical activity and compliance of the patient concerned are decisive for the individual therapeutic protocol. Alternative surgical techniques in upper ankle osteoarthritis are assessed such as denervation, distraction arthroplasty, correction osteotomy, ankle arthrodesis and total ankle replacement.

Adolescent↗

[Computer-assisted arthrodesis of the sacroiliac joint].

Arthrodesis of the sacroiliac joint (SI) usually requires a large surgical exposure using the lateral approach. Computer-assisted surgery based on intraoperative 3D fluoroscopy imaging can reduce the approach to stab incisions. The clinical example shows the insertion of two screws and a cylindrical bone graft to achieve an arthrodesis of the SI joint. The intraoperatively navigated placement of implants and bone graft was performed only by stab incisions.

Adult↗

[The physics of vacuum therapy].

BACKGROUND: Vacuum therapy is a routine and successful method for wound treatment and for the temporary covering of soft-tissue defects. It is an occlusive method that can be used for treating acute, chronic and infected wounds. To date, no data are available regarding secretion transit times and pressure conditions in lesions treated with vacuum therapy. The present study had as its objectives to examine the mechanisms of vacuum therapy and determine the effects of physical forces on the wound surface with the purpose of formulating recommendations for pressure settings using the various available vacuum pumps. MATERIAL AND METHODS: Using an appropriate model, we measured secretion transit times and pressures using two different vacuum therapy pads. We then conducted pressure measurements during dressing change in eight patients with wound surfaces greater than 20 cm(2). RESULTS: The secretion transit times remained unchanged with the polyvinyl alcohol (PVA) pad and a negative pressure of 40 kPa, but decreased by about 50 % when the black polyurethane (PU) pad was used. Pressure measurements showed that, at this negative pressure, there was only a slight positive external pressure of 31 mmHg on the wound surface. CONCLUSION: When the PVA pad is used, negative pressures greater than 40 kPa should be applied in order to effect a maximum transit of wound secretion and prolongation of the use of the vacuum dressing. When the PU pad is used, the applied negative pressure can be lower due to the pad's larger pores, as recommended by Argenta and Morykwas. An excessive external pressure on the wound surface does not occur.

Biophysical Phenomena↗

In vitro low-speed side collisions cause injury to the lower cervical spine but do not damage alar ligaments.

Whether injuries to the alar ligaments could be responsible for complaints of patients having whiplash injury in the upper cervical spine is still controversially discussed. It is known that these ligaments protect the upper cervical spine against excessive lateral bending and axial rotation movements. The objective of the present in vitro study was therefore to examine whether the alar ligaments or any other structures of the cervical spine are damaged in side collisions. In a specially designed acceleration apparatus, six human osteoligamentous cervical spine specimens were subjected to incremental 90 degrees side collisions from the right (1 g, 2 g, 3 g, etc.) until structural failure occurred. A damped pivot table accounted for the passive movements of the trunk during collision, and a dummy head (4.5 kg) ensured almost physiological loading of the specimens. For quantification of functional injuries, the three-dimensional flexibility of the specimens was tested in a spine tester before and after each acceleration. In all six specimens, structural failure always occurred in the lower cervical spine and always affected the facet joint capsules and the intervertebral discs. In four specimens, this damage occurred during the 2 g collision, while in the other two it occurred during the 3 g and 4 g collision, respectively. The flexibility mainly increased in the lower cervical spine (especially in lateral bending to both sides) and, to a minor extent, in axial rotation. In vitro low-speed side collisions caused functional and structural injury to discoligamentous structures of the lower cervical spine, but did not damage the alar ligaments. Since the effects of muscle forces were not taken into account, the present in vitro study reflects a worst-case scenario. Injury thresholds should therefore not be transferred to reality.

Acceleration↗

[Complications of malignant tumors--pathological fractures].

Advances in the treatment of tumors have improved the life expectancy of cancer patients appreciably. As a consequence the incidence of bone metastases has also increased. Surgical interventions must achieve a maximal palliative effect with minimal morbidity and mortality. Major objectives are reduction of pain while preserving stability and function. Surgical treatment of primary and secondary bone tumors is complicated and thus also burdened with complications. However, interdisciplinary therapy comprising surgical resection and stabilization, radiotherapy and/or chemotherapy improves life expectancy and the quality of life of the cancer patient.

Bone Neoplasms↗

Difference in metallic wear distribution released from commercially pure titanium compared with stainless steel plates.

INTRODUCTION: Stainless steel and commercially pure titanium are widely used materials in orthopedic implants. However, it is still being controversially discussed whether there are significant differences in tissue reaction and metallic release, which should result in a recommendation for preferred use in clinical practice. MATERIALS AND METHODS: A comparative study was performed using 14 stainless steel and 8 commercially pure titanium plates retrieved after a 12-month implantation period. To avoid contamination of the tissue with the elements under investigation, surgical instruments made of zirconium dioxide were used. The tissue samples were analyzed histologically and by inductively coupled plasma atomic emission spectrometry (ICP-AES) for accumulation of the metals Fe, Cr, Mo, Ni, and Ti in the local tissues. Implant corrosion was determined by the use of scanning electron microscopy (SEM). RESULTS: With grades 2 or higher in 9 implants, steel plates revealed a higher extent of corrosion in the SEM compared with titanium, where only one implant showed corrosion grade 2. Metal uptake of all measured ions (Fe, Cr, Mo, Ni) was significantly increased after stainless steel implantation, whereas titanium revealed only high concentrations for Ti. For the two implant materials, a different distribution of the accumulated metals was found by histological examination. Whereas specimens after steel implantation revealed a diffuse siderosis of connective tissue cells, those after titanium exhibited occasionally a focal siderosis due to implantation-associated bleeding. Neither titanium- nor stainless steel-loaded tissues revealed any signs of foreign-body reaction. CONCLUSION: We conclude from the increased release of toxic, allergic, and potentially carcinogenic ions adjacent to stainless steel that commercially pure Ti should be treated as the preferred material for osteosyntheses if a removal of the implant is not intended. However, neither material provoked a foreign-body reaction in the local tissues, thus cpTi cannot be recommend as the 'golden standard' for osteosynthesis material in general.

Adipose Tissue↗

[Total knee arthroplasty--navigation as the standard].

Today the most common application in the field of computer-assisted surgery is navigated total knee arthroplasty. During the last 5 years the imageless kinematic navigation systems have gained wide acceptance. As several prospective randomized studies could show, the standard deviation of the mechanical axis is reduced significantly by these techniques. However, the direction of the mechanical axis is only one factor which influences the long-term results of total knee arthroplasty. Further important factors are ligament balancing and position of the femoral and tibial components in all three planes. Up to now no studies have been able to show a significantly better functional result, a more rapid recovery, or a decreased complication rate. Drawbacks of the navigation systems are the additional costs and the additional operation time between 15 and 20 min. Therefore, navigated total knee arthroplasty is not yet a standard procedure, but this technique is well on the way to becoming the gold standard in the future.

Algorithms↗

[Stationary thromboprophylaxis in casualty surgery. Relevance of postoperative mobility and preexisting risk factors].

The presented thromboprophylactic concept includes weight bearing and ankle motion as well as breathing therapy and drug prophylaxis (antiphlogistics, analgesic drugs, heparin). Routinely performed ultrasound screening of the deep veins (legs and pelvis) before release showed a low DVT incidence of 2.5% in a prospective clinical observation of 841 inpatients. Obesity, venous insufficiency, and a history of previous thromboembolic events were associated with a significantly increased risk of thrombosis (relative risk 4.1, 4,9, and 5.8, respectively) The duration of immobilization also had a relevant influence indicating that early postoperative physiotherapy in traumatology and orthopedic surgery has a widely underestimated thromboprophylactic effect.

Adolescent↗

[Incidence of severe injuries. Results of a population-based analysis].

It is still unknown exactly how many persons sustain a severe injury (ISS > or =16) in Germany each year. Considering the growing restrictions and the introduction of DRGs, it was necessary to acquire data about this rather resource-intensive aspect of trauma care. The aim of this study was therefore to assess the incidence of severe trauma within a defined population. In a retrospective study all surgical emergencies within a 5-year period (1996-2000) were reviewed. Data on type, pattern, severity of injury, and mortality were extracted from the patients' records. During the study period 454 persons sustained a severe injury (ISS > or =16), 112 individuals died at the scene of the accident, and 64 during the hospital stay. The average ISS of the surviving patients was 27 (ISS 16-75). The calculated incidence of severe trauma was 25/100,000 inhabitants per year. Extrapolated, up to 40,000 persons sustain a severe injury each year in Germany. For the first time, this study has provided data on the incidence of major trauma in Germany. Based on the acquired data and a previous cost analysis, hospital treatment costs for severely injured patients amount to up to 2 billion Euros per year in Germany.

Adolescent↗

[Diagnostic apparatus in the shock trauma room].

Opinions vary with regard to the equipment and structural furnishings required for adequate management of the trauma patient in the dedicated shock suite. In order to assess the current situation in Germany, we conducted a survey of the 76 centers participating in the Polytrauma Registry of the DGU. Fifty-one questionnaires were returned by centers representing all levels of care. Responses revealed, for example, that not all centers possess capabilities for conventional radiography in the shock suite (7/51). Only 20 centers had a fixed table; the remaining 24 hospitals used either an image converter or a mobile X-ray unit. A dedicated ultrasound scanner was provided for the shock suite in 39 of 51 centers responding. Dedicated computed tomography scanners were provided for the shock suite in only eight centers (one dedicated trauma center, three level 3 centers, four university hospitals). All eight scanners use helical CT technology; at least three of the units are 8- or 16-slice. Of 51 shock suites, 12 are air-conditioned in compliance with sterile criteria (and are officially designated as surgical suites), while the remaining 39 are not. In acute cases, emergency surgeries can be performed in the shock suite in 37 centers, but not in the remaining 14 shock suites. According to the survey, slightly less than half of the hospitals responding are un-satisfied with the shock suite infrastructure ( n=24) and, of these, 13 centers are actively planning changes (the necessary financial resources have been guaranteed in 10 centers). Fourteen centers desire changes but do not currently have the required money. Information provided by Philips and Siemens suggests that the cost of furnishing a new shock suite ranges between 1.4 and 1.7 million euros. Responses to our survey show that a large gap remains between wishes and reality in the technical infrastructure in many shock suites in Germany.

Diagnostic Equipment↗

[Accident analytics for structural traumas of the cervical spine].

The differentiation between degenerative syndromes of the cervical spine and post-traumatic symptoms requires accident analysis. Experiments with human subjects yield data only in the low-energy range, and there are still no accident analyses of structural traumas of the cervical spine. From 1 January 2000 to 30 April 2002, 15 patients with structural injuries to the cervical spine due to car accidents were treated in the Department of Trauma Surgery of the University of Ulm. In 11 of these cases, the DEKRA Ulm completed an appraisal of the accident process.With lateral impacts, structural injuries to the cervical spine can occur even at speeds of only ca 10 km/h. Injuries to the alar ligaments are produced by frontal collisions with substantial differences in speed. Data from accident analysis of structural injuries to the cervical spine must be taken into consideration in causality examinations of distortions of the cervical spine.

Accidents, Traffic↗

A new acceleration apparatus for the study of whiplash with human cadaveric cervical spine specimens.

The biomechanics of whiplash is often studied using cadaveric cervical spine specimens. One of the most important points in this kind of study is to create realistic loading conditions. The aim of the present project therefore was to develop an acceleration apparatus, which allows the study of whiplash with human cadaveric cervical spine specimens under as realistic loading conditions as possible. The new acceleration apparatus mainly consisted of a sled, a pneumatic acceleration unit and a railtrack and offered several unique features to create more realistic loading conditions. Among these features, the possibility to simulate the passive movements of the trunk is of capital importance. In this new apparatus, first, the general feasibility of whiplash experiments was studied, second, the reproducibility of the impacts was quantified and third, the effect of simulated movements of the trunk on accelerations and loads was examined. In the new acceleration apparatus various types of collisions could reproducibly be simulated. Simulated passive movements of the trunk strongly influenced the loading pattern of the neck. Without pivoting a steep increase of all loading parameters could be observed. This increase was less pronounced if pivoting was allowed. In conclusion, biomechanical aspects of whiplash could reproducibly be examined in the new acceleration apparatus. Due to its significant effects on the loading of the neck, pivoting of the trunk should always be taken into account in future experiments on the biomechanics of whiplash in which isolated cervical spine specimens are used.

Acceleration↗