PubMed Health⌕ Search

Biomedical subjects

L L Nelson

Publications and source records attributed to L L Nelson.

10 recordsLinked to original sources

Use of automated external defibrillators by a U.S. airline.

BACKGROUND: Passengers who have ventricular fibrillation aboard commercial aircraft rarely survive, owing to the delay in obtaining emergency care and defibrillation. METHODS: In 1997, a major U.S. airline began equipping its aircraft with automated external defibrillators. Flight attendants were trained in the use of the defibrillator and applied the device when passengers had a lack of consciousness, pulse, or respiration. The automated external defibrillator was also used as a monitor for other medical emergencies, generally at the direction of a passenger who was a physician. The electrocardiogram that was obtained during each use of the device was analyzed by two arrhythmia specialists for appropriateness of use. We analyzed data on all 200 instances in which the defibrillators were used between June 1, 1997, and July 15, 1999. RESULTS: Automated external defibrillators were used for 200 patients (191 on the aircraft and 9 in the terminal), including 99 with documented loss of consciousness. Electrocardiographic data were available for 185 patients. The administration of shock was advised in all 14 patients who had electrocardiographically documented ventricular fibrillation, and no shock was advised in the remaining patients (sensitivity and specificity of the defibrillator in identifying ventricular fibrillation, 100 percent). The first shock successfully defibrillated the heart in 13 patients (defibrillation was withheld in 1 case at the family's request). The rate of survival to discharge from the hospital after shock with the automated external defibrillator was 40 percent. A total of 36 patients either died or were resuscitated after cardiac arrest. No complications arose from use of the automated external defibrillator as a monitor in conscious passengers. CONCLUSIONS: The use of the automated external defibrillator aboard commercial aircraft is effective, with an excellent rate of survival to discharge from the hospital after conversion of ventricular fibrillation. There are not likely to be complications when the device is used as a monitor in the absence of ventricular fibrillation.

Aged↗

Initial energy for elective external cardioversion of persistent atrial fibrillation.

We conducted a prospective randomized study to determine the safety and efficacy rate of 3 commonly used energy levels (100, 200, and 360 J) for elective direct-current cardioversion of persistent atrial fibrillation. When compared with 100 and 200 J, the initial success rate with 360 J was significantly higher (14%, 39%, and 95%, respectively), and patients randomized to 360 J ultimately required less total energy and a lower number of shocks.

Aged↗

Preventing adverse outcomes: a population focus.

This article discusses the concept of risk from an epidemiological viewpoint as well as that of vulnerable populations. Three components of resource availability are pertinent to the concept of risk of a population: social status, social capital, and human capital. These components are illustrated through an example of a project to reduce preventable adverse health outcomes and increase competency in self-care among residents of an inner-city community. Activities and outcomes of the project are discussed.

Child, Preschool↗

An evaluation of four end-user systems for searching MEDLINE.

This study compared features and determined which of four end-user systems (PaperChase, GRATEFUL MED, Med-Base, or Compact Cambridge: MEDLINE) would best serve the Medical Sciences and Optometry Libraries of Indiana University in providing biomedical information to faculty and graduate students through MEDLINE. Cost, ease of use, retrieval, training needs, equipment requirements, and adequacy of documentation were examined. The study consisted of a comparison of the features of each system based on available documentation; a controlled search performed by the investigators on each system and on regular NLM MEDLINE; and a user study based on observations, questionnaires, and interviews with eleven library patrons who performed the same search of their choice on each of the four systems.

Computer Systems↗

An evaluation of four end-user systems for searching MEDLINE.

This study compared features and determined which of four end-user systems (PaperChase, GRATEFUL MED, Med-Base, or Compact Cambridge: MEDLINE) would best serve the Medical Sciences and Optometry Libraries of Indiana University in providing biomedical information to faculty and graduate students through MEDLINE. Cost, ease of use, retrieval, training needs, equipment requirements, and adequacy of documentation were examined. The study consisted of a comparison of the features of each system based on available documentation; a controlled search performed by the investigators on each system and on regular NLM MEDLINE; and a user study based on observations, questionnaires, and interviews with eleven library patrons who performed the same search of their choice on each of the four systems.

Computer User Training↗

Toward assessing family outcomes of service delivery: validation of a family quality of life survey.

BACKGROUND: The concept of family quality of life (QoL) has emerged as an important outcome of service delivery for individuals with disabilities and their families. The present study describes the process of developing a tool to measure family QoL. METHODS AND RESULTS: A total of 1197 respondents participated in a national field test. Through factor analysis, the survey was refined in several ways: (1) the preliminary 10-domain structure was reduced to a five-domain structure; (2) a total of 41 items were selected for the revised survey; and (3) wordings were clarified. CONCLUSIONS: The implications for future research and practice are discussed.

Adolescent↗