Anaesthesia for a patient with Gitelman's syndrome undergoing abdominal hernia repair.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to L L Szegedi.
Explore the source record for details and available documents.
Anaesthesia for patients with Leigh's syndrome has rarely been reported. Leigh's syndrome or subacute necrotizing encephalomyelopathy is a neurodegenerative disorder of infancy or childhood. Acute exacerbation with respiratory failure may accompany surgery and general anaesthesia. In this case report we describe the anaesthetic management of a 17 year old patient scheduled for spine surgery.
BACKGROUND: We measured lung mechanics and gas exchange during one-lung ventilation (OLV) of patients with chronic obstructive pulmonary disease, using three respiratory rates (RR) and unchanged minute volume. METHODS: We studied 15 patients about to undergo lung surgery, during anaesthesia, and placed in the lateral position. Ventilation was with constant minute volume, inspiratory flow and FIO2. For periods of 15 min, RR of 5, 10, and 15 bpm were applied in a random sequence and recordings were made of lung mechanics and an arterial blood gas sample was taken. Data were analysed with the repeated measures ANOVA and paired t-test with Bonferroni correction. RESULTS: PaO2 changes were not significant. At the lowest RR, PaCO2 decreased (from 42 (SD 4) mm Hg at RR 15-41 (4) mm Hg at RR 10 and 39 (4) mm Hg at RR 5, P<0.01), and end-tidal carbon dioxide increased (from 33 (5) mm Hg at RR 15 to 35 (5) mm Hg at RR 10 and 36 (6) mm Hg at RR 5, P<0.01). Intrinsic positive end-expiratory pressure (PEEPi) was reduced even with larger tidal volumes (from 6 (4) cm H2O at RR 15-5 (4) cm H2O at RR 10, and 3 (3) cm H2O at RR 5, P<0.01), most probably caused by increased expiratory time at the lowest RR. CONCLUSION: A reduction in RR reduces PEEPi and hypercapnia during OLV in anaesthetized patients with chronic obstructive lung disease.
The management of some problematic patients having thoracic surgery is among the most difficult challenges for the anesthesiologist. Increasingly complex operations are performed on seriously compromised patients because of the development of new surgical techniques and the anesthesiologists' awareness of surgical needs and requirements to provide a satisfactory and safe surgical field. In order to facilitate thoracic surgery, the single most important and valuable anesthetic technique used actually is one-lung ventilation. This article reviews the complex pathopysiology of one-lung ventilation.
UNLABELLED: We compared the effects of position and fraction of inspired oxygen (F(IO)2) on oxygenation during thoracic surgery in 24 consenting patients randomly assigned to receive an F(IO)2 of 0.4 (eight patients, Group 0.4), 0.6 (eight patients, Group 0.6), or 1.0 (eight patients, Group 1.0) during the periods of two-lung (TLV) and one-lung ventilation (OLV) in the supine and lateral positions. TLV and OLV were maintained while the patients were first in the supine and then in the lateral position for 15 min each. Thereafter, respiratory mechanical data were obtained, and arterial blood gas samples were drawn. Pao2 decreased during OLV compared with TLV in both the supine and lateral positions. In all three groups, Pao2 was significantly higher during OLV in the lateral than in the supine position: 101 (72-201) vs 63 (57-144) mm Hg in Group 0.4; 268 (162-311) vs 155 (114-235) mm Hg in Group 0.6; and 486 (288-563) vs 301 (216-422) mm Hg in Group 1.0, respectively (P < 0.02, Wilcoxon's signed rank test). We conclude that, compared with the supine position, gravity augments the redistribution of perfusion as a result of hypoxic pulmonary vasoconstriction, when patients are in the lateral position, which explains the higher Pao2 during OLV. IMPLICATIONS: This study compares oxygenation during thoracic surgery during periods of two-lung and one-lung ventilation with patients in the supine and lateral positions when using three different fraction of inspired oxygen values. Arterial oxygen tension was decreased in all three groups during one-lung ventilation in comparison with the two-lung ventilation values, but the decrease was significantly less in the lateral, compared with the supine position.
This investigation analyzed the changes in inspiratory airway pressures during transition from two-lung to one-lung ventilation in patients tracheally intubated with a double-lumen endotracheal tube (DLT) using a classical method of intubation without fiberoptic bronchoscopy. All patients were anesthetized in a standardized fashion. Ventilation was accomplished with the Siemens 900 constant-flow mechanical ventilator (Solna, Sweden). Peak (Ppeak) and plateau (Pplateau) inspiratory airway pressures were recorded with an on-line respiratory monitor before and after clamping the tracheal limb of the DLT. The position of the DLTs was evaluated by fiberoptic bronchoscopy with the patient in supine position. Of the 51 intubations, the DLT was malpositioned in 15 cases (29.5%). Ppeak and Pplateau increased significantly when switched from two-lung ventilation to one-lung ventilation in both correctly and incorrectly positioned DLTs. When the DLT was in a correct position, Ppeak increased by a mean of 55.1% and Pplateau increased by a mean of 41.9%. When the DLT was malpositioned, this increase was significantly larger (74.9% and 68.8%, respectively). Three tests commonly used as markers of malpositioned DLTs were evaluated based on the data of this study, and it was established that, although the pressure differences related to position are statistically significant, as a single value, they cannot be used for clinical decision making.