PubMed Health⌕ Search

Biomedical subjects

L Laricchia-Robbio

Publications and source records attributed to L Laricchia-Robbio.

7 recordsLinked to original sources

Comparison of a conventional immunoassay (ELISA) with a surface plasmon resonance-based biosensor for IGF-1 detection in cows' milk.

Recombinant bovine somatotropin (rBST) treatment is adopted in dairy cows to augment milk yield. Previous studies showed that insulin-like growth factor-1 (IGF-1) is present in milk from cows treated with rBST. Since IGF-1 is a suspected carcinogen, its presence in milk for human consumption is potentially a health hazard. Therefore rBST use, still authorized in the United States, has been revoked in Canada and is under evaluation in the EU. The rising attention on IGF-1 presence in alimentary milk focused the necessity to develop specific, sensitive and rapid IGF-1 detection systems. We have developed a solid phase enzyme-linked immunoassay (ELISA) and also an automated surface plasmon resonance-based biosensor system (BIA-technology) for evaluating IGF-1 in fresh cow's milk. Hyperimmune polyclonal anti-IGF-1 antibodies were characterized with respect to their specific binding capacity to IGF-1. The results obtained with these two methods have been compared. This study shows the potential usefulness of the biosensor technology for biomolecular interaction analysis. The features of this technology (fully automated, measures in real time, sharpened yes/no response) offer several advantages compared to ELISA in the detection of compounds in fresh cows' milk (MURST 40%; CNR P.F. MADESS 2).

Animals↗

Detection of digitalis compounds using a surface plasmon resonance-based biosensor.

An automated surface plasmon resonance-based biosensor system has been used to detect endogenous and exogenous digitalis-like factors (EDLF) in the pmolar range in real time. EDLF was purified from umbilical cord blood. EDLF has been suggested to play a role in hypertension and in perinatal adaptation. Highly specific polyclonal anti-ouabain antibodies showed a high affinity binding capacity for ouabain, ouabagenin and strophantidin with an IC50 value of 5 x 10(-10) M, 7.0 x 10(-10) M and 2 x 10(-8) M, respectively. EDLF cross-reacted with antibodies and its concentration in plasma at IC50 was around 50 pmol ouabain equivalent. This study shows the potential usefulness of the biosensor technology for biomolecular interaction analysis. The features of this technology (fully automated, measured in real time, sharpened response) offer several advantages compared with a traditional immunoassay like radioimmunoassay (RIA) in the detection of digitalis compounds in human fluids.

Antibodies↗

Structure-activity analysis of C-terminal endothelin analogues.

Several synthetic endothelin (ET) analogues of the C-terminal ET hexapeptide (ET16-21) were analyzed by radio-receptor competition binding assays and biologic activity using both ETA and ETB receptor subtypes. In addition, we produced a hybridoma monoclonal antibody, anti-ET15-21, that appeared to crossreact with the entire ET molecule and was able to neutralize its biologic activity. Antibody binding was measured with competition enzyme-linked immunosorbent assays and a surface plasmon resonance-based biosensor (BIA technology). The ET16-21 moiety was modified with systematic replacement of each residue by alanine (Ala-scan). Whereas the C-terminal residues (Asp18, Ile20, and particularly Trp21) were very important for both receptor binding and immunologic activity, Ala substitution in positions 16, 17, and 19 hardly affected such activities. Analysis of another series of synthetic ET16-21 analogues with the His16 residue replaced by a non-amino-acidic block confirmed that the last two C-terminal residues are essential for receptor and antibody binding, whereas the central region of this hexapeptide is much more tolerant to modification. However, a critical steric conformation of the active hexapeptide is necessary.

Animals↗

Naturally occurring and therapy-induced antibodies to human granulocyte colony-stimulating factor (G-CSF) in human serum.

Sera were obtained from two groups of patients. Group A included 7 patients with low-grade non-Hodgkin's lymphoma treated with three or more cycles of standard-dose chemotherapy and recombinant human granulocyte-colony stimulating factor (rhG-CSF). The cytokine was administered to half the patients after the first chemotherapy cycle and to the other half after the second according to a randomized design and then to all patients from the third chemotherapy cycle on, until documented hemopoietic reconstitution. Group B included 3 patients with high-grade non-Hodgkin's lymphoma, 1 patient with resistant Hodgkin's disease, and 1 patient with multiple myeloma who received high-dose chemotherapy and rhG-CSF. Anti-G-CSF antibodies were detected in the sera of 4 patients. Both immunoglobulin IgM and IgG antibodies were detected at low levels in pretreatment sera from one group A patient. IgG antibody titers increased markedly during the first and second periods of G-CSF administration. IgG class antibodies developed in 3 groups B patients during the first course of rhG-CSF administration. Circulating anti-G-CSF antibodies did not seem to affect hematological recovery. Low levels of anti-G-CSF antibodies were also detected in sera (15/135) from different healthy adults and in sera (5/40) from umbilical cord blood. Saturable antibody binding and competition enzyme-linked immunosorbent assay (ELISA) and immunoblotting confirmed antibody specificity.

Adolescent↗

Detection and epitope mapping of immunoreactive human endothelin-1 using ELISA and a surface plasmon resonance-based biosensor.

A surface plasmon resonance-based biosensor (BIA technology) and enzyme-linked immunosorbent assays (ELISA) have been used for detecting and characterizing human endothelin (ET), a potent vasoactive 21 amino acid polypeptide. Antibodies produced against the isoform ET-1 and its C-terminal eptapeptide ET-1(15-21) have been characterized with respect to their binding capacity to the two isoforms ET-1 and ET-3, the non-secreted portion of the precursor molecule Big.ET-1(22-38), the C-terminal of ET-1, six analogues of ET-1(16-21) each containing a substitution with Ala of a single amino acid in positions 16-21, respectively, and three synthetic cyclic peptides mimicking the N-terminal portion of ET-1. Antibodies reacting with ET-1 also bound to ET-1(16-21) and, with less affinity, to ET-3 but did not cross-react with Big.ET-1(22-38). Ala substitution in positions 16, 17 and 19 of ET-1(16-21) hardly affected the antibody binding capacity of ET-1(16-21), whereas Ala substitution of Asp18, Ile20 and, in particular, Trp21, inhibited its immunoreactivity. The C-terminus thus represents an immunodominant epitope in ET-1 and is important for antibody binding. Epitope mapping using as antibody pairs polyclonal anti-ET-1 and monoclonal anti-ET-1(15-21) antibodies indicated the presence of another immunogenic domain in the N-terminal portion of the molecule. There was excellent agreement between the epitopes determined using ELISA and BIA analyses.

Amino Acid Sequence↗

Natural and therapy-induced anti-GM-CSF and anti-G-CSF antibodies in human serum.

Serum samples were obtained from patients with lymphoid and plasma cell malignancies who received after chemotherapy human recombinant GM-CSF or G-CSF. Sera from some patients revealed the presence of anti-cytokine antibodies, particularly after repetitive cytokine injections. Antibody Fab binding in a saturable manner by ELISA and Western immuno-blotting confirmed antibody specificity. Anti-cytokine antibodies were detected before the exogenous cytokine injections in some patients, but increasing antibody levels were found after one or subsequent treatments. Low levels of anti-GM-CSF and anti-G-CSF antibodies were also detected in a relatively large proportion (about 10-30%) of normal sera from different adult healthy volunteers who had never been treated before with exologous cytokines as well as from cord blood. EBV-immortalized cord blood derived B-cell cultures were also found to produce anti GM-CSF and/or anti-G-CSF antibodies with high frequency.

Adult↗

Mapping of monoclonal antibody- and receptor-binding domains on human granulocyte-macrophage colony-stimulating factor (rhGM-CSF) using a surface plasmon resonance-based biosensor.

An automated surface plasmon resonance (SPR)-based biosensor system has been used for mapping antibody and receptor-binding regions on the recombinant human granulocyte-macrophage colony-stimulating factor (rhGM-CSF) molecule. A rabbit antimouse IgG1-Fc antibody (RAM.Fc) was coupled to an extended carboxymethylated-hydrogel matrix attached to a gold surface in order to capture an anti-rhGM-CSF monoclonal antibody (MAb) injected over the sensing layer. rhGM-CSF was subsequently injected and allowed to bind to this antibody. Multisite binding assays were then performed, by flowing sequentially other antibodies and peptides over the surface, and the capacity of the latter to interact with the entrapped rhGM-CSF in a multimolecular complex was monitored in real time with SPR. Eleven MAb (all IgG1K), were analyzed: respectively, four antipeptide MAb raised against three distinct epitopes of the cytokine (two clones against residues 14-24, that includes part of the first alpha-helix toward the N-terminal region; one clone against peptide 30-41, an intrahelical loop; and one clone against residues 79-91, including part of the third alpha-helix) and seven antiprotein MAbs raised against the entire rhGM-CSF, whose target native epitopes are still undetermined. In addition, the binding capacity to rhGM-CSF of a synthetic peptide, corresponding to residues 238-254 of the extracellular human GM-CSF receptor alpha-chain, endowed with rhGM-CSF binding activity, was tested. The results from experiments performed with the biosensor were compared with those obtained by a sandwich enzyme-linked immunosorbent assay (ELISA), using the same reagents. The features of the biosensor technology (fully automated, measure in real time, sharpened yes/no response, less background disturbances, no need for washing step or labeling of the reagent) offered several advantages in these studies of MAb immunoreactivity and epitope mapping, giving a much better resolution and enabling more distinct epitopes to be identified over ELISA.

Antibodies, Monoclonal↗