PubMed Health⌕ Search

Biomedical subjects

L Leape

Publications and source records attributed to L Leape.

16 recordsLinked to original sources

Influence of projected complication rates on estimated appropriate use rates for carotid endarterectomy. Appropriateness Project Investigators. Academic Medical Center Consortium.

OBJECTIVE: To examine specifically the influence of estimated perioperative mortality and stroke rate on the assessment of appropriateness of carotid endarterectomy. DATA SOURCES/STUDY SETTING: An expert panel convened to rate the appropriateness of a variety of potential indications for carotid endarterectomy based on various rates of perioperative complications. We then applied these ratings to the charts of 1,160 randomly selected patients who had carotid endarterectomy in one of the 12 participating academic medical centers. STUDY DESIGN: An expert panel evaluated indications for carotid endarterectomy using the modified Delphi approach. Charts of patients who received surgery were abstracted, and clinical indications for the procedure as well as perioperative complications were recorded. To examine the impact of surgical risk assessment on the rates of appropriateness, three different definitions of risk strata for combined perioperative death or stroke were used: Definition A, low risk < 3 percent; Definition B, low risk < 5 percent; and Definition C, low risk < 7 percent. PRINCIPAL FINDINGS: Overall hospital-specific mortality ranged from 0 percent to 4.0 percent and major complications, defined as death, stroke, intracranial hemorrhage, or myocardial infarction, varied from 2.0 percent to 11.1 percent. Most patients (72 percent) had surgery for transient ischemic attack or stroke; 24 percent of patients were asymptomatic. Most patients (82 percent) had surgery on the side of a high-grade stenosis (70-99 percent). When the thresholds for operative risk were placed at the values defined by the expert panel (Definition A), only 33.5 percent of 1,160 procedures were classified as "appropriate." When the definition of low risk was shifted upward, the proportion of cases categorized as appropriate increased to 58 percent and 81.5 percent for Definitions B and C, respectively. CONCLUSIONS: Despite the high proportion of procedures performed for symptomatic patients with a high degree of ipsilateral extracranial carotid artery stenosis and generally low rates of surgical complications at the participating institutions, the overall rate of "appropriateness" using a perioperative complication rate of < 3 percent was low. However, the rate of "appropriateness" was extremely sensitive to judgments about a single clinical feature, surgical risk. These data show that before applying such "appropriateness" ratings, it is crucial to perform sensitivity analyses in order to assess the stability of the results. Results that are robust to moderate in variation in surgical risk provide a much sounder basis for policy making than those that are not.

Academic Medical Centers↗

Relationship between medication errors and adverse drug events.

OBJECTIVE: To evaluate the frequency of medication errors using a multidisciplinary approach, to classify these errors by type, and to determine how often medication errors are associated with adverse drug events (ADEs) and potential ADEs. DESIGN: Medication errors were detected using self-report by pharmacists, nurse review of all patient charts, and review of all medication sheets. Incidents that were thought to represent ADEs or potential ADEs were identified through spontaneous reporting from nursing or pharmacy personnel, solicited reporting from nurses, and daily chart review by the study nurse. Incidents were subsequently classified by two independent reviewers as ADEs or potential ADEs. SETTING: Three medical units at an urban tertiary care hospital. PATIENTS: A cohort of 379 consecutive admissions during a 51-day period (1,704 patient-days). INTERVENTION: None. MEASUREMENTS AND MAIN RESULTS: Over the study period, 10,070 medication orders were written, and 530 medications errors were identified (5.3 errors/100 orders), for a mean of 0.3 medication errors per patient-day, or 1.4 per admission. Of the medication errors, 53% involved at least one missing dose of a medication; 15% involved other dose errors, 8% frequency errors, and 5% route errors. During the same period, 25 ADEs and 35 potential ADEs were found. Of the 25 ADEs, five (20%) were associated with medication errors; all were judged preventable. Thus, five of 530 medication errors (0.9%) resulted in ADEs. Physician computer order entry could have prevented 84% of non-missing dose medication errors, 86% of potential ADEs, and 60% of preventable ADEs. CONCLUSIONS: Medication errors are common, although relatively few result in ADEs. However, those that do are preventable, many through physician computer order entry.

Boston↗

The treatment of Wilms' tumor: results of the Second National Wilms' Tumor Study.

One-hundred-eighty-eight children up to 16 years of age were randomized in the second National Wilms' Tumor Study (NWTS) with tumors that were confined to the kidney and that had been totally excised (Group I). Most fared well whether treated for six or for 15 months with both actinomycin D (AMD) and vincristine (VCR). No postoperative radiation therapy (RT) was given. The two-year relapse-free survival (RFS) and two-year survival rates were 88 and 95%, respectively. Two-hundred-sixty-eight randomized patients with more advanced local lesions (Groups II and III) and 57 with distant metastases (Group IV) had postoperative RT and were scheduled for 15 months treatment with either AMD and VCR (Reg. C) or AMD plus VCR plus Adriamycin (Reg. D). The 77% two-year RFS rate for Reg. D was significantly different from the 63% with Reg. C. As in the first NWTS, patients with tumors of unfavorable histology (UH) had a significantly worse prognosis than those with favorable histology (FH), as did those with positive nodes. Survival rates at two years were 54% for UH vs. 90% for FH, and 54% vs. 82% for those with and without lymph node involvement.

Adolescent↗

Familial occurrence of gastroschisis. Four new cases and review of the literature.

In two unrelated families, there was familial occurrence of gastroschisis. In one family, a boy and girl were affected and there was a family history of stillbirth, abortion, prematurity, and esophageal obstruction. In the second family, two boys were affected and there was a family history of spontaneous abortion, inguinal hernia, and umbilical hernia. The recurrence of gastroschisis, generally considered a sporadic congenital effect, suggests that the condition may be genetic in nature. Furthermore, the pedigree of one of the families suggests that gastroschisis may be a severe expression of umbilical hernia or other abdominal wall defects. Autosomal dominant inheritance with variable expressivity or multifactorial inheritance may explain the occurrence of gastroschisis in the two families. Thus, a family history of abdominal wall defects may increase the risk for gastroschisis.

Abdominal Muscles↗

Natural history of familial medullary thyroid carcinoma: effect of a program for early diagnosis.

To detect familial medullary thyroid carcinoma in a premetastatic stage, we administered tests provocative of calcitonin secretion (infusion of calcium or pentagastrin or both) each year for seven years to members of a pedigree now numbering 107. Since 1970, 21 patients converted from normal to abnormal secretory responses (two separate tests in which calcitonin levels exceeded 0.58 ng per milliliter). Twenty of 21 glands removed showed C-cell hyperplasia, and eight of the 20 also showed foci of carcinoma. As compared to the 12 patients with tumors detected during the first year of screening, all of whom had bilateral carcinoma (seven of 12 with local metastases), later carcinomas were smaller (mean diameter of 0.2 vs. 0.8 cm), were unilateral (in all but two cases) and occurred in younger patients (mean age of 14.9 vs. 36.4 years), and none had detectable metastases.

Adolescent↗

Identifying adverse drug events: development of a computer-based monitor and comparison with chart review and stimulated voluntary report.

BACKGROUND: Adverse drug events (ADEs) are both common and costly. Most hospitals identify ADEs using spontaneous reporting, but this approach lacks sensitivity; chart review identifies more events but is expensive. Computer-based approaches to ADE identification appear promising, but they have not been directly compared with chart review and they are not widely used. OBJECTIVES: To develop a computer-based ADE monitor, and to compare the rate and type of ADEs found with the monitor with those discovered by chart review and by stimulated voluntary report. DESIGN: Prospective cohort study in one tertiary-care hospital. PARTICIPANTS: All patients admitted to nine medical and surgical units in a tertiary-care hospital over an eight-month period. MAIN OUTCOME MEASURE: Adverse drug events identified by the computer-based monitor, by chart review, and by stimulated voluntary report. METHODS: A computer-based monitoring program identified alerts, which were situations suggesting that an ADE might be present (e.g., an order for an antidote such as naloxone). A trained reviewer then examined patients' hospital records to determine whether an ADE had occurred. The results of the computer-based monitoring strategy were compared with two other ADE detection strategies: intensive chart review and stimulated voluntary report by nurses and pharmacists. The monitor and the chart review strategies were independent, and the reviewers were blinded. RESULTS: The computer monitoring strategy identified 2,620 alerts, of which 275 were determined to be ADEs. The chart review found 398 ADEs, whereas voluntary report detected 23. Of the 617 ADEs detected by at least one method, 76 ADEs were detected by both computer monitor and chart review. The computer monitor identified 45 percent; chart review, 65 percent; and voluntary report, 4 percent. The ADEs identified by computer monitor were more likely to be classified as "severe" than were those identified by chart review (51 versus 42 percent, p = .04). The positive predictive value of computer-generated alerts was 16 percent during the first eight weeks of the study; rule modifications increased this to 23 percent in the final eight weeks. The computer strategy required 11 person-hours per week to execute, whereas chart review required 55 person-hours per week and voluntary report strategy required 5. CONCLUSIONS: The computer-based monitor identified fewer ADEs than did chart review but many more ADEs than did stimulated voluntary report. The overlap among the ADEs identified using different methods was small, suggesting that the incidence of ADEs may be higher than previously reported and that different detection methods capture different events. The computer-based monitoring system represents an efficient approach for measuring ADE frequency and gauging the effectiveness of ADE prevention programs.

Adverse Drug Reaction Reporting Systems↗

The impact of computerized physician order entry on medication error prevention.

BACKGROUND: Medication errors are common, and while most such errors have little potential for harm they cause substantial extra work in hospitals. A small proportion do have the potential to cause injury, and some cause preventable adverse drug events. OBJECTIVE: To evaluate the impact of computerized physician order entry (POE) with decision support in reducing the number of medication errors. DESIGN: Prospective time series analysis, with four periods. SETTING AND PARTICIPANTS: All patients admitted to three medical units were studied for seven to ten-week periods in four different years. The baseline period was before implementation of POE, and the remaining three were after. Sophistication of POE increased with each successive period. INTERVENTION: Physician order entry with decision support features such as drug allergy and drug-drug interaction warnings. MAIN OUTCOME MEASURE: Medication errors, excluding missed dose errors. RESULTS: During the study, the non-missed-dose medication error rate fell 81 percent, from 142 per 1,000 patient-days in the baseline period to 26.6 per 1,000 patient-days in the final period (P < 0.0001). Non-intercepted serious medication errors (those with the potential to cause injury) fell 86 percent from baseline to period 3, the final period (P = 0.0003). Large differences were seen for all main types of medication errors: dose errors, frequency errors, route errors, substitution errors, and allergies. For example, in the baseline period there were ten allergy errors, but only two in the following three periods combined (P < 0.0001). CONCLUSIONS: Computerized POE substantially decreased the rate of non-missed-dose medication errors. A major reduction in errors was achieved with the initial version of the system, and further reductions were found with addition of decision support features.

Clinical Pharmacy Information Systems↗