Automated registration of dynamic MR images for the quantification of myocardial perfusion.

Cardiac dynamic magnetic resonance imaging (MRI) after contrast media injection suffers from motion induced by free breathing during acquisition. This work presents an automated approach for motion correction of the heart. The registration is based on the multipass/multiresolution iterative minimizing of intrinsic differences between each image and a reference image coupled to a two-dimensional/3 parameters rigid body correction. The efficiency of this correction method was evaluated with anatomical landmarks, various cost functions, and for a compartment model fit of the data with 2 parameters: K1, the blood to myocardium transfer coefficient; and Vd, the distribution volume of the contrast media. The variability of K1 and Vd, derived from the fit of the registered images (using the manual correction as a gold standard), was significantly reduced by comparison with the variability obtained from the uncorrected images (P < 0.04). This motion correction method also clearly improves the analysis of dynamic cardiac MRI after contrast media injection in comparison to manual correction.

Contrast Media↗

Second-generation three-dimensional reconstruction for rotational three-dimensional angiography.

RATIONALE AND OBJECTIVES: The purpose of this study was to assess the feasibility and accuracy of three-dimensional (3D) reconstruction techniques for digital subtraction angiography (DSA) in planning and evaluation of minimally invasive image-controlled therapy. MATERIALS AND METHODS: Using a standard, commercially available system, the authors acquired DSA images and corrected them for inherent distortions. They designed and implemented parallel and multiresolution versions of cone-beam reconstruction techniques to reconstruct high-resolution targeted volumes in a short period of time. Testing was performed on anatomically correct, calibrated in vitro models of a cerebral aneurysm. These models were used with a pulsatile circulation circuit to allow for blood flow simulation during DSA, computed tomographic (CT) angiography, and magnetic resonance (MR) angiography image acquisitions. RESULTS: The multiresolution DSA-based reconstruction protocol and its implementation allowed the authors to achieve reconstruction times and levels of accuracy for the volume measurement of the aneurysmal cavities that were considered compatible with actual clinical practice. Comparison with data obtained from other imaging modalities shows that, besides vascular tree depiction, the DSA-based true 3D technique provides volume estimates at least as good as those obtained from CT and MR angiography. CONCLUSION: The authors demonstrated the feasibility and potential of true 3D reconstruction for angiographic imaging with DSA. On the basis of the model testing, this work addresses both the timing and quantification required to support minimally invasive image-controlled therapy.

Algorithms↗

Three- to five-dimensional biomedical multisensor imaging for the assessment of neurological (dys) function.

This report describes techniques and protocols implemented at the Geneva Canton University Hospitals (HUG) for the combination of various biomedical imaging modalities and sensors including electromagnetic tomography, to study, assess, and localize neurological (dys) function. The interest for this combination stems from the broad variety of information brought out by (functional) magnetic resonance imaging, magnetic resonance spectroscopy, computed tomography, single-photon emission tomography, positron emission tomography, and electromagnetic tomography. Combining these data allows morphology, metabolism, and function to be studied simultaneously, the complementary nature of the information from these modalities becoming evident when studying pathologies reflected by metabolic or electrophysiologic dysfunctions. Compared with other current multimodality approaches, the one at the HUG is totally compatible with both clinical and research protocols, and efficiently addresses the multidimensional registration and visualization issues. It also smoothly integrates electrophysiology and related data as fully featured modalities.

Computer Graphics↗

Brain hypometabolism of glucose in anorexia nervosa: a PET scan study.

Cerebral glucose metabolism was studied in 20 underweight anorectic girls and in 10 age- and sex-matched healthy volunteers using positron emission tomography with (18-F)-fluorodeoxy-glucose. Both groups were scanned during rest, with eye closed and with low ambient noise. Compared to controls, the underweight anorectic group showed a global hypometabolism (p = .002) and an absolute (p < .001) as well as relative (p < .01) hypometabolism of glucose in cortical regions, with the most significant differences found in the frontal and the parietal cortices. Within the underweight anorectic and the control groups, no correlations were found between absolute or relative rCMRGlu and BMI, anxiety scores, or Hamilton scores of depression. Different factors might explain this reduction of glucose metabolism in anorexia nervosa. It might be the consequence of neurophysiological or morphological aspects of anorexia nervosa and/or the result of some associated symptoms such as anxiety or depressed feelings. Supported by cognitive studies, we can also hypothesize a primary corticocerebral dysfunctioning in anorexia nervosa.

Adolescent↗

Use of positron emission tomography (PET) in stereotactic conditions for brain biopsy.

In order to take advantage of the metabolic information provided by positron emission tomography (PET) in cases of brain tumour, we have developed a technique to integrate PET images routinely in the planning of stereotactic brain biopsy. We used stereotactic PET with [18F]-labelled fluorodeoxyglucose (PET-FDG) in 38 patients undergoing brain biopsy. To evaluate the contribution of PET-FDG in guiding brain biopsy, we analyzed the diagnosis provided by the 78 stereotactic trajectories obtained in these patients. We found that stereotactic PET-FDG seemed to provide more information in cases of anaplastic astrocytomas and glioblastomas than in low-grade gliomas. Our results also show that biopsy trajectories performed in areas where increased FDG uptake is found within the lesion boundaries always provide interpretable specimens; this was not the case for trajectories guided by CT only. Therefore, the routine integration PET-FDG in the planning of stereotactic brain biopsy may lead to a reduction in sampling. Recently, we also tested consecutive stereotactic PET with [11C]-labelled methionine (PET-Met) and PET-FDG. This technique allowed us to compare accurately the tumoural glucose metabolism and protein synthesis. Our results suggest that stereotactic PET may increase the diagnostic yield of brain biopsy and may improve the understanding of PET in neuro-oncology.

Adult↗

Reversible striatal hypermetabolism in a case of Sydenham's chorea.

We studied a 10-year-old girl with Sydenham's chorea (SC) using positron emission tomography (PET) with fluorodeoxyglucose (FDG). Choreic movements involved the head and the left side of her body. PET showed increased glucose metabolism in the right caudate nucleus and putamen. Three months after complete recovery, striatal glucose metabolism had returned to normal in the caudate nucleus. In the right putamen, glucose metabolism had decreased compared to that in the first study but remained elevated compared to that of normal young adults. We propose that the transient striatal hypermetabolism may have been due to increased afferent inputs to the striatum as a consequence of striatal or subthalamic nucleus dysfunction.

Basal Ganglia↗

Brain glucose metabolism and dopamine D2 receptor analysis in a patient with hemiparkinsonism-hemiatrophy syndrome.

We report findings on brain glucose metabolism and dopamine D2 receptors generated by positron emission tomography (PET) in a 67-year-old woman with right hemiparkinsonism-hemiatrophy syndrome (HP-HA). PET with [18F]-fluorodeoxyglucose (FDG) showed marked glucose metabolism asymmetry. There were significant reductions in glucose uptake at the level of the basal ganglia and, to lesser extent, in the fronto-parietal cortex contralateral to the clinically involved side. These changes were different from those found in a patient with hemi-Parkinson's disease who was scanned under similar conditions. Because the patient with HP-HA had only minimal response to levodopa therapy, we evaluated post-synaptic dopaminergic structures using PET with [18F]-fluoroethylspiperone (FESP). No striatal binding asymmetry was found in FESP/PET, which suggests a sparing of striatal dopamine D2 receptors. The changes in FDG uptake which we found were in brain areas relevant to the clinical features of HP-HA syndrome. In addition, our study provides evidence that FDG/PET may help to differentiate HP-HA syndrome from hemi-Parkinson's disease. In most instances, since HP-HA is associated with a more benign clinical course than Parkinson's disease, this distinction is of clinical important.

Aged↗

Hemibody tremor related to stroke.

BACKGROUND: Hemibody tremor is an uncommon manifestation of stroke. We describe a case investigated by both brain magnetic resonance imaging and positron emission tomography using [18F]fluorodeoxyglucose. CASE DESCRIPTION: Three months after a pure motor stroke, a 65-year-old man developed a right arm and leg tremor. The tremor was of large amplitude, intermittent at rest; its frequency was 5 to 6 Hz. Neither rigidity nor akinesia was detected, and administration of L-dopa was ineffective. Brain magnetic resonance imaging revealed an ischemic lesion in the left centrum semiovale and a left caudate lacunar infarction. We suspected that the resting unilateral tremor was related to this lacunar lesion. Positron emission tomography demonstrated glucose hypermetabolism in the left sensorimotor cortex. CONCLUSIONS: This case suggests that unilateral tremor may be related to a lacunar stroke in the caudate nucleus and may be accompanied by an increased glucose metabolism in the contralateral sensorimotor cortex.

Aged↗

Positron emission tomography and histopathology in Creutzfeldt-Jakob disease.

We studied a 62-year-old man with Creutzfeldt-Jakob disease (CJD), using positron emission tomography (PET) and (18F)-2-fluoro-2-deoxy-D-glucose (FDG). Glucose metabolism was heterogeneously decreased throughout the brain. At autopsy, regional distributions of spongiosis, astrogliosis, and neuronal loss correlated with premortem regional metabolic deficits. These results suggest that PET with FDG may provide metabolic regional markers for CJD neuropathology.

Brain↗

Positron emission tomography-guided stereotactic brain biopsy.

We describe a technique that allows target definition for stereotactic brain biopsy using coordinates calculated on stereotactic positron emission tomographic (PET) images. In this study, PET images were obtained using [18F]-labeled fluorodeoxyglucose, a marker for glucose metabolism. The difference between PET-calculated and actual stereotactic coordinates of simulated targets is within PET spatial resolution. Combined computed tomography- and PET-guided stereotactic biopsies were performed in 11 patients with brain tumors. In this report, we describe two representative patients who underwent stereotactic brain biopsy using the present technique. Because of the complementary role of PET and computed tomography, their integration in multimodality planning might optimize the target selection for stereotactic brain biopsies.

Astrocytoma↗

Telematics techniques for image based diagnosis, therapy planning and monitoring.

This paper is intended to describe and illustrate some of the actual use of telematics related techniques together with modern biomedical imaging capabilities for helping in diagnosis, as well as for the planning and monitoring of therapy. To this end, most current imaging modalities are initially introduced. Then it is shown how telematics related techniques are necessary to improve the outcome of current image-based protocols. Such techniques allow data, means, or competencies--which may intrinsically be of a complementary nature or distributed at many different locations--to be integrated together and transcend the simple sum of individual expectations. Examples of actual implementations are given in the fields of radio-oncology, neurosurgery and orthopedics. To conclude, the papers and posters presented in the corresponding session of the MIE'97 symposium are summarized to provide further telematics references for the reader.

Aged↗