PubMed Health⌕ Search

Biomedical subjects

L N Benson

Publications and source records attributed to L N Benson.

At least 19 recordsLinked to original sources

Silent and audible persistent ductus arteriosus: an angiographic study.

Persistent ductus arteriosus (PDA) murmurs become silent probably due to the direction of the jet across the ductus arteriosus when entering the pulmonary artery. Out of 15 children with silent PDA, 14 demonstrated a ductal flow not contacting and away from the anterior wall of the main pulmonary artery. In 15 children with a continuous murmur caused by a PDA, 12 exhibited a ductal flow toward and reaching the anterior wall of the MPA. There was no correlation between the presence of a murmur and the size of the arterial duct in this study.

Angiography↗

Right ventricular form and function after percutaneous atrial septal defect device closure.

OBJECTIVES: We sought to assess the right heart's response to percutaneous device closure of moderate sized atrial septal defects (ASDs) in adults over a one-year follow-up period. BACKGROUND: Percutaneous ASD device closure is a safe and effective means of reducing or eliminating interatrial shunting. The response of the adult's right heart to device closure is incompletely understood. METHODS: Forty consecutive patients had 40 device implantations (32 with the CardioSeal implant and 8 with the Amplatzer device). The patients were assessed with echocardiography, chest radiography and electrocardiography before the procedure and at 1, 6 and 12 months. RESULTS: The mean ASD size was 13+/-4 mm, and the device size ranged from 33 to 40 mm for CardioSeal and 12 to 36 mm for Amplatzer. At one month, heart size (49% vs. 46%), four-chamber right ventricular (RV) size (45 vs. 41 mm), paradoxical septal motion (60% vs. 5%), QRS duration (125 vs. 119 ms), PR interval (181 vs. 155 ms) and echocardiographically determined pulmonary artery systolic pressure decreased significantly and was maintained at 12-month follow-up. At six months, right atrial length decreased from 50 to 47 mm. At one year, 29% of patients had persistent RV enlargement. CONCLUSIONS: Right heart morphology undergoes rapid improvement within one month of defect closure, with associated mechanoelectrical benefit. A small number of patients had persistent RV enlargement or pulmonary hypertension, or both, at one year. Our data support the application of transcatheter methods in achieving excellent hemodynamic and anatomic outcomes.

Adult↗

ABO-incompatible heart transplantation in infants.

BACKGROUND: Transplantation of hearts from ABO-incompatible donors is contraindicated because of the risk of hyperacute rejection mediated by preformed antibodies in the recipient to blood-group antigens of the donor. This contraindication may not apply to newborn infants, who do not yet produce antibodies to T-cell-independent antigens, including the major blood-group antigens. METHODS: We studied 10 infants 4 hours to 14 months old (median, 2 months) who had congenital heart disease or cardiomyopathy and who received heart transplants from donors of incompatible blood type between 1996 and 2000. Serum isohemagglutinin titers were measured before and after transplantation. Plasma exchange was performed during cardiopulmonary bypass; no other procedures for the removal of antibodies were used. Standard immunosuppressive therapy was given, and rejection was monitored by means of endomyocardial biopsy. The results were compared with those in 10 infants who received heart transplants from ABO-compatible donors. RESULTS: The overall survival rate among the 10 recipients with ABO-incompatible donors was 80 percent, with 2 early deaths due to causes presumed to be unrelated to ABO incompatibility. The duration of follow-up ranged from 11 months to 4.6 years. Two infants had serum antibodies to antigens of the donor's blood group before transplantation. No hyperacute rejection occurred; mild humoral rejection was noted at autopsy in one of the infants with antibodies. No morbidity attributable to ABO incompatibility has been observed. Despite the eventual development of antibodies to antigens of the donor's blood group in two infants, no damage to the graft has occurred. Because of the use of ABO-incompatible donors, the mortality rate among infants on the waiting list declined from 58 percent to 7 percent. CONCLUSIONS: ABO-incompatible heart transplantation can be performed safely during infancy before the onset of isohemagglutinin production; this technique thus contributes to a marked reduction in mortality among infants on the waiting list.

ABO Blood-Group System↗

Comparison of two transcatheter closure methods of persistently patent arterial duct.

A randomized trial of arterial duct occlusion with a double umbrella (DU) or wire coil (WC) was undertaken for patients <18 years of age, weighing >10 kg with isolated ducts < or = 3 mm in diameter. Baseline, procedural, and outcome characteristics were compared in an intention-to-treat analysis according to randomization group. From 40 consecutively screened patients, 2 were not enrolled due to a ductal diameter of >3 mm on initial aortography, 38 patients were randomized to either the DU (n = 20) or WC (n = 18) groups. The groups did not differ significantly with respect to age, weight, gender, duct size, type, or branch pulmonary artery diameters. Crossover occurred only in the DU group, where 4 patients (20%) had a ductal diameter of < or = 1 mm and could not be entered for umbrella placement. All remaining DU group patients had ductal diameters of > or = 1.3 mm (p <0.0001). There were no embolizations or secondary implants in the DU group, but in the WC group there was 1 early and 1 late embolization, with 6 patients (33%) with > or = 2 coils. Mean times for the procedure (DU 68+/-19 minutes; WC 65+/-27 minutes; p = 0.70) and fluoroscopy (DU 14+/-4 minutes; WC 11+/-6 minutes; p = 0.22) did not differ significantly. Angiographic duct closure was documented in 4 of 13 patients (31%) of the DU group and 4 of 18 patients (22%) of the WC group (p = 0.69). Combined with an echocardiogram, closure in 11 of 17 patients with DU (65%) and 13 of 18 patients with WC (72%) (p = 0.64) was documented before hospital discharge. One WC group patient received thrombolytic therapy for a femoral artery thrombus. Follow-up at a median of 6.5 months (range 3.2 to 37) showed closure by Doppler echocardiography in 15 of 19 patients with DU (79%) versus 14 of 18 patients with WC (78%) (p = 1.0). Thus, with a tendency toward similar procedural characteristics and outcomes, the higher cost of the DU system compared with coil implants favors the use of coils for closure of the small arterial duct.

Analysis of Variance↗

Outcomes of transcatheter embolization in the treatment of coronary artery fistulas.

Thirteen children (seven male) with coronary artery fistula underwent percutaneous transcatheter occlusion. The age range was 8 months to 14 years (mean, 6.3 years). The fistulas had their origins from the right coronary artery (six), from the left anterior descending coronary artery (three), and from the left circumflex coronary artery (four). Drainage was to the right ventricle (seven), the right atrium (three), and one each to the pulmonary artery, left atrium, and superior caval vein. The fistulas were closed with coils in 10 patients, a Rashkind double-umbrella device in 1 patient, and an Amplatzer Duct Occluder in 2 patients. Complete occlusion was achieved in 9 of 13 patients. Complications consisted of migration of coils in four and transient arrhythmias or changes in the resting electrocardiogram in four patients. Follow-up studies 1 to 31 months (mean, 14.6 months) after occlusion noted only four patients with trivial (clinically insignificant) residual shunts. Owing to various coronary fistula morphologies, transcatheter occlusion requires availability of different embolization techniques. Short-term follow-up supports persistent clinical efficacy and transcatheter closure techniques as the initial form of therapy.

Adolescent↗

Transcatheter creation of an atrial septal defect using radiofrequency perforation.

Transseptal perforation using radiofrequency energy was performed successfully in a patient with congenital heart disease and a thickened interatrial septum. This was followed by balloon dilatation of the atrial septal defect. Radiofrequency is presented as a alternative to standard transseptal needle puncture. Cathet Cardiovasc Intervent 2001;54:83-87.

Catheter Ablation↗

Total cavopulmonary connections in children with a previous Norwood procedure.

BACKGROUND: Outcomes of the Fontan operation in children initially palliated with the modified Norwood procedure are incompletely defined. METHODS: From August 1993 to January 2000, 45 patients (mean age 2.6 +/- 1.1 years, weight 12.7 +/- 2.8 kg) who were palliated with staged Norwood procedures (hypoplastic left heart syndrome, n = 32; nonhypoplastic left heart syndrome, n = 13) underwent a modified Fontan operation. Preoperative features included moderate/severe atrioventricular valve regurgitation (n = 5, 11%), reduced ventricular function on echocardiography in 11 patients, McGoon index 1.56 +/- 0.38, and pulmonary artery distortion in 18 patients (40%). RESULTS: A lateral tunnel (n = 16) or an extracardiac conduit (n = 29) connection with fenestration in 38 patients (84%) was used. Concomitant procedures included pulmonary artery reconstruction (n = 24, 53%), atrioventricular valve repair (n = 4, 9%) or replacement (n = 1). Before Fontan, 12 patients (27%) had an intervention to address neoaortic obstruction, and 7 patients required balloon dilation/stenting of the left (n = 5) or right pulmonary artery (n = 5). Intraoperatively, left (n = 5) or right pulmonary artery (n = 1) stenting was performed in 5 patients (11%). On follow-up, 8 patients required additional interventional procedures to address left pulmonary artery narrowing (n = 5), or venous (n = 5) or arteriopulmonary collaterals (n = 1). Perioperative mortality was 4.4% (n = 2). There were 2 late deaths at a mean follow-up of 39 +/- 20 months. CONCLUSIONS: In relatively high-risk patients, midterm results of the Fontan operation for children initially palliated with the Norwood procedure were good. Combined interventional-surgical treatment algorithms can lead to improved outcomes.

Child↗

Chylopericardium after cardiac operations in children.

BACKGROUND: Chylopericardium is a rare complication after operation for congenital heart disease. The incidence and clinical outcomes in a large cohort of surgical patients are unknown. METHODS: We retrospectively reviewed the clinical records spanning more than 12 years in a single institution of 16 children with chylopericardium after cardiac operation. RESULTS: We identified 16 patients with chylopericardium between 1985 and 1997. Chylopericardium was isolated in 7 patients. Twelve patients required pericardial drainage. Patients with isolated chylopericardium presented late and were treated initially as having postpericardiotomy syndrome. Three patients underwent thoracic duct ligation. There were two late deaths unrelated to the chylothorax. Associated diagnoses were internal jugular vein thrombosis and recurrent pulmonary vein obstruction (1 of 16 patients), an associated syndrome but not Turner or Noonan (10 of 16), superior cavopulmonary or total cavopulmonary anastomosis (7 of 16), atrioventricular septal defect repair (5 of 16), and repair of tetralogy of Fallot (2 of 16). CONCLUSIONS: Percutaneous drainage to relieve tamponade together with a low-fat or medium-chain triglyceride diet results in resolution in most cases of postoperative chylopericardium. If a pericardial effusion enlarges, fails to clear on aspirin therapy, or presents late after hospital discharge, diagnostic pericardial tap and a low-fat diet are indicated.

Cause of Death↗

Evolving strategies and improving outcomes of the modified norwood procedure: a 10-year single-institution experience.

BACKGROUND: This study reviews our 10-year experience with the modified Norwood procedure to determine its early and midterm outcomes. The focus is on the impact of evolving management strategies and accumulated institutional experience. METHODS: A modified Norwood operation was performed in 171 infants over a 10-year period. Sixty-eight percent of the infants were male, the median age at operation was 6 days (range 1 to 175 days), and the median weight was 3.3 kg (range 1.7 to 4.8 kg). The 10-year period was divided into three eras: era I; 1990 through 1993; era II; 1994 through 1997; and era III; 1998 into 2000. Outcomes and risk factors for mortality were sought. RESULTS: Hypoplastic left heart syndrome or a variant was the primary diagnosis in 118 infants (69%). The overall 5-year survival rate was 43%. Multivariate analysis revealed that only need of preoperative ventilatory support, earlier date of operation, and lower weight at operation were significant independent predictors of increased time-related mortality. Morphologic features such as a diagnosis other than hypoplastic left heart syndrome, ascending aortic size, and noncardiac anomalies were not significantly associated with an increased risk of death. The hospital survival rate for stage-one palliation in era III was 82%, significantly better than that in the preceding eras (p < 0.001). Attrition between stages one and two accounted for a 15% mortality rate among hospital survivors. CONCLUSIONS: With increasing experience and improvements in perioperative care and surgical technique, good outcomes can be expected for the first-stage modified Norwood procedure. Greater monitoring of patients in the interstage period may reduce interval mortality and improve overall survival.

Female↗

Outcomes of intraoperative device closure of muscular ventricular septal defects.

BACKGROUND: The surgical management of muscular ventricular septal defects (mVSD) in the small infant is a challenge particularly when multiple and associated with complex cardiac lesions. Devices for percutaneous implantation have the advantage of ease of placement and for the double umbrella designs a wide area of coverage. We reviewed our experience and clinical outcomes of intraoperative mVSD device closure for such defects in small infants. METHODS: Since October 1989, intraoperative VSD device closure was a component of the surgical strategy in 14 consecutive patient implants (median age, 5.5 months; range, 3 to 11 kg), whose defects were thought difficult to approach using conventional techniques. Nine patients had associated complex cardiac lesions, 10 multiple mVSDs, and 4 patients had a previous pulmonary artery banding. RESULTS: There were 2 early deaths, 1 in a severely ill child who preoperatively had pulmonary hypertension and left ventricular failure and another in a patient with a hypoplastic left heart. Mean pulmonary to systemic flow ratio before device insertion was 3.5:1. Complete closure was achieved in 5 patients and clinically insignificant residual shunts persisted in 7. In 2 infants with significant residual lesions concomitant pulmonary artery banding was required. Postoperative mean pulmonary to systemic flow ratio was 1.7:1. In follow-up of the 12 surviving infants (mean, 41 months), 8 had complete closure and 3 persistent residual shunts. One patient with no residual shunting required heart transplantation for progressive ventricular failure 9 years after operation. All devices were well positioned on postoperative echocardiograms. There was 1 late death due to aspiration in a patient with a tiny residual shunt. CONCLUSIONS: Infants requiring operative intervention with mVSDs are difficult to manage and have an increased mortality and morbidity. Intraoperative VSD device placement for closure of mVSDs is feasible, can avoid ventriculotomy, division of intracardiac muscle bands, and is ideally suited for the neonate or infant.

Echocardiography↗

Outcomes of transcatheter balloon angioplasty of obstruction in the neo-aortic arch after the Norwood operation.

Obstruction of the reconstructed aortic arch, or the neoaortic arch, is now known to be an important factor increasing mortality after the Norwood operation for hypoplastic left heart syndrome. Transcatheter balloon angioplasty has been shown to provide effective relief of both native aortic coarctation and obstructions of the aortic arch occurring subsequent to therapeutic intervention. We sought to determine the outcomes of balloon angioplasty used as an initial treatment for obstruction of the neoaortic arch occurring after the Norwood operation. We gathered the characteristics of 58 patients with such obstruction from 8 institutions, noting procedural factors and outcomes of initial balloon dilation. Obstruction occurred at a median interval of 4 months, with a range from 1.5 months to 6.3 years, after a Norwood operation. Ventricular dysfunction was present before dilation in 13 patients. Mean peak to peak systolic pressure gradients were acutely reduced from 31+/-20 mm Hg to 6+/-9 mmHg (p<0.001), with outcome subjectively judged to be successful in 89%. Three patients with pre-existing ventricular dysfunction died within 48 hours of dilation. There were 10 additional deaths during the period of follow-up, with Kaplan Meier estimates of survival after intervention of 87% at 1 month, 77% at 12 months, and 72% after 15 months. In addition, 9 patients required re-intervention during the period of follow-up, with Kaplan Meier estimates of freedom from re-intervention after dilation of 87% at 6 months, 78% at 12 months and 74% after 18 months. Although transcatheter dilation of neoaortic arch obstructions after Norwood operation is successful, there is a high risk of re-intervention and ongoing mortality in this subgroup of patients. Close follow-up is recommended.

Angioplasty, Balloon↗

The effect of implantation of aortic stents on compliance and blood flow. An experimental study in pigs.

Balloon dilation of coarctation of the aorta has been found to be an effective modality for treatment. Recently, in the older child and adult, implantation of endovascular stents has been considered a clinical alternative to dilation alone. Little is known, however, of the effect of implantation of stents on aortic compliance. To investigate this impact of implantation, we studied 18 piglets, divided into experimental and control groups. At median weight of 14 kg, 2 pairs of ultrasonic crystals were implanted on the aortic wall. After 1 week, all animals underwent catheterization. In the experimental group, a 3 cm long balloon expandable stent was implanted in the descending thoracic aorta between the pairs of crystals. Measurements of arterial pressure and dimensions were performed before implantation and immediately thereafter, and at follow-up catheterization. The index of stiffness, beta, and the the elastic modulus of aortic pressure-strain, were calculated as indexes of arterial compliance. The change in compliance during the period of study was not different between groups. At follow-up, no difference was observed between groups in the velocity of the aortic pulse wave, the augmentation index, or the maximum velocity of flow of blood. The stents remained patent and did not affect aortic growth or medial wall thickness. There was no difference between groups in levels of plasma renin activity and serum aldosterone. In this animal model studied over the short term, therefore, implantation of stents does not affect aortic compliance. Further studies are required to elucidate the long term effects of stents on the hemodynamics affecting the aortic wall and local flow dynamics.

Animals↗

Safety and outcomes of thrombolysis with tissue plasminogen activator for treatment of intravascular thrombosis in children.

OBJECTIVES: In this study, we tried to determine the safety and outcomes of thrombolysis with tissue plasminogen activator of intravascular thrombus. STUDY DESIGN: Eighty consecutive children were treated between 1985 and 1999 in a tertiary care setting in a retrospective case series. There were 65 arterial thrombi (56 after cardiac catheterization) and 15 venous thrombi treated with tPA at an average dose of tPA of 0.5 mg/kg/hour for a median duration of 6 hours. RESULTS: Clot resolution was complete in 65% of children, partial in 20%, and there was no effect in 15%. There were major complications in 40%, minor complications in 30%, and no complications in 30%. Two patients had cerebral ischemia secondary to hypotension because of profound bleeding, with intracranial hemorrhage in 2 additional patients. Clot resolution was not related to patient age or weight, dose, and duration of tPA therapy and fibrinogen levels. However, complications were more likely in patients who weighed less, had a longer duration of therapy, a greater decrease in fibrinogen levels, and who failed to have resolution of their clot. CONCLUSIONS: tPA therapy can be effective in the thrombolysis of intravascular thrombus in children, but is associated with a low margin of safety and an unknown risk-benefit ratio.

Adolescent↗

Extracardiac conduit versus lateral tunnel cavopulmonary connections at a single institution: impact on outcomes.

OBJECTIVE: To compare outcomes of extracardiac conduit and lateral tunnel Fontan connections in a single institution over a concurrent time period. METHODS: Between January 1994 and September 1998, 60 extracardiac conduit and 47 lateral tunnel total cavopulmonary connections were performed. Age, sex, and weight did not differ between the 2 groups. Compared with the lateral tunnel group (LT group), patients undergoing the extracardiac conduit procedure (EC group) had a trend to a higher incidence of morphologically right ventricle (EC group 48% vs LT group 32%; P <.09), a higher incidence of isomerism/heterotaxy syndrome (EC 22% vs LT 0%; P <.001), worse atrioventricular valve regurgitation (EC 11% moderate-plus vs LT 0%; P <.06), and lower McGoon indices (EC 1.8 +/- 0.5 vs LT 2.1 +/- 0.5; P <.03). Preoperative arrhythmias, transpulmonary gradients, room air oxygen saturations, ejection fractions, ventricular end-diastolic pressure, and pulmonary artery distortion did not differ between groups. Cardiopulmonary bypass times and fenestration usage were similar in both groups. RESULTS: Overall operative mortality was 5.6% and did not differ between groups. The LT group had a significantly higher incidence of postoperative sinoatrial node dysfunction (45% vs EC group 15%; P <.007), supraventricular tachycardia (33% vs EC group 8%; P <.0009), and need for temporary postoperative pacing (32% vs 12%; P <.01). Median duration of intensive care unit stay (EC 2 days, range 1-10 days, vs LT 2.8 days, range 1-103 days; P <.07) and ventilatory support (EC 1 day, range 0.25-10 days, vs LT 1 day, range 0.25-99 days; P <.03) were all longer in the LT group. Median chest tube drainage (EC 8 days, LT 9 days) was similar in both groups. Follow-up averaged 2.5 +/- 1.4 years in the EC group and 2.8 +/- 1.9 years in the LT group. There were 2 late deaths. Overall survival is 94% at 1 month, 92% at 1 year, and 92% at 5 years. Late ejection fraction or atrioventricular valve function did not differ between groups. Intermediate follow-up Holter analysis showed a higher incidence of atrial arrhythmias in the LT group (23% vs 7%; P <.02). Multivariable analysis showed that (1) prolonged cardiopulmonary bypass time was the only independent predictor for perioperative mortality, prolonged ventilation and intensive care unit length of stay, and increased time to final removal of chest tube drains and (2) lateral tunnel Fontan connection is an independent predictor of early postoperative and intermediate atrial arrhythmias. CONCLUSIONS: Although patients in the EC group were at higher preoperative risk, their outcomes were comparable with those of the LT group. Use of the extracardiac conduit technique for the modified Fontan operation reduces the risk of early and midterm atrial arrhythmia.

Arrhythmias, Cardiac↗

Intravascular and intracardiac stents used in congenital heart disease.

Intravascular or intracardiac stenoses occur in many forms of congenital heart disease or after attempted surgical repair. Although balloon dilation is one option for management, restenosis can occur due to elastic recoil immediately after the procedure. To address to such stenotic lesions, many reports support implanting endovascular stents to provide a framework for vessel expansion. Both balloon-expandable fixed tubular mesh stainless steel devices, and self-expandable stents have had an extensive clinical application. In pediatric patients, stents are used for a variety of stenoses, such as systemic venous obstruction pathways (eg, Mustard, Fontan baffle, or bidirectional cavopulmonary connections), pulmonary artery, right ventricular to pulmonary conduits, aortic coarctation, the arterial duct, aorticopulmonary collaterals, or postoperative systemic to pulmonary shunts. Because of improvements in device profile, implantation rates have increased. Complications such as stent fracture, migration, aneurysm formation, and in-stent restenosis occur but only rarely. This latter event may be because of intimal hyperplasia and/or continued vessel (and patient) growth related to the stent diameter. As such, some instances require redilation to manage the acquired lesion. Stent application has importantly altered management algorithms in congenital heart disease.

Adolescent↗