CO2 elimination at varying inspiratory pause in acute lung injury.

Previous studies have indicated that, during mechanical ventilation, an inspiratory pause enhances gas exchange. This has been attributed to prolonged time during which fresh gas of the tidal volume is present in the respiratory zone and is available for distribution in the lung periphery. The mean distribution time of inspired gas (MDT) is the mean time during which fractions of fresh gas are present in the respiratory zone. All ventilators allow setting of pause time, T(P), which is a determinant of MDT. The objective of the present study was to test in patients the hypothesis that the volume of CO(2) eliminated per breath, V(T)CO(2), is correlated to the logarithm of MDT as previously found in animal models. Eleven patients with acute lung injury were studied. When T(P) increased from 0% to 30%, MDT increased fourfold. A change of T(P) from 10% to 0% reduced V(T)CO(2) by 14%, while a change to 30% increased V(T)CO(2) by 19%. The relationship between V(T)CO(2) and MDT was in accordance with the logarithmic hypothesis. The change in V(T)CO(2) reflected to equal extent changes in airway dead space and alveolar PCO(2) read from the alveolar plateau of the single breath test for CO(2). By varying T(P), effects are observed on V(T)CO(2), airway dead space and alveolar PCO(2). These effects depend on perfusion, gas distribution and diffusion in the lung periphery, which need to be further elucidated.

Aged↗

Partitioning of dead space--a method and reference values in the awake human.

Although dead space is often increased in disease, it is not frequently measured in the clinic. This may reflect that an adequate method as well as reference values are missing. Healthy males and females, n=38, age 20-61 yrs, were connected to a pneumotachograph and a fast CO2 analyser after radial artery catheterization. The physiological dead space was partitioned into airway and alveolar dead space using a delineation principle denoted the pre-interface expirate. Physiological dead space was 201+/-41 mL in males and 150+/-34 mL in females. Dead space values were depending upon parameters reflecting lung size (predicted total lung capacity), breathing pattern and age. After multiple correlation the variation decreased and differences between males and females disappeared. The residual SD was then for physiological dead space 18.9 mL. The clinical use of the new method for determination of dead space can be based upon reference values, with a more narrow range than previous data.

Adult↗

Dose reduction in gastrointestinal and genitourinary fluoroscopy: use of grid-controlled pulsed fluoroscopy.

OBJECTIVE: We evaluated the diagnostic accuracy of a grid-controlled fluoroscopy unit compared with a conventional continuous fluoroscopy unit for a variety of abdominal and pelvic fluoroscopic examinations. SUBJECTS AND METHODS: Seventy patients (29 men and 41 women; age range, 24-78 years) were enrolled in one of seven abdominal and pelvic fluoroscopic examinations, including upper gastrointestinal series (n = 20), barium enema (n = 10), voiding cystourethrogram (n = 10), percutaneous abdominal catheter tube injection (n = 10), hysterosalpingogram (n = 10), and percutaneous needle insertion and catheter placement (nephrostomy, percutaneous biliary drainage) (n = 10). Each patient underwent at least 10 sec of continuous fluoroscopy that was randomly and blindly compared with 10-sec periods of pulsed fluoroscopy at 15, 7.5, and 3.75 frames per second. A radiologist outside the examination room, unaware of the frame rate per second, evaluated the procedure in real time on a television monitor. The radiologist assessed image quality and diagnostic acceptability using a scoring system. Statistical analysis was performed using the paired Student's t test. RESULTS: For all procedures at all frame rates, we found no statistically significant superiority of one frame rate over another. For most procedures, the slower frame rates were considered equivalent to continuous fluoroscopy when the images were assessed for image quality and diagnostic confidence. CONCLUSION: Our findings suggest that most abdominal and pelvic fluoroscopic procedures can be performed at substantially lower frame rates than those used for continuous fluoroscopy; adopting this procedure may lead to substantial dose savings for the patient and the fluoroscopy operator.

Adult↗

Surface hydrolysis of poly(glycolic acid) meshes increases the seeding density of vascular smooth muscle cells.

A procedure for surface hydrolysis of poly(glycolic acid) (PGA) meshes was developed to increase cell seeding density and improve attachment of vascular smooth muscle cells. Hydrolysis of PGA in 1N NaOH transformed ester groups on the surface of PGA fibers to carboxylic acid and hydroxyl groups. After hydrolysis, the polymer scaffold retained its original gross appearance and dimensions while the fiber diameter decreased. A plot of fiber diameter versus the hydrolysis time showed a linear relationship, with a rate of decrease in fiber diameter of 0.65 microm/min. The molecular weight and thermal properties of the polymer did not change significantly following surface hydrolysis. In cell seeding experiments, surface-hydrolyzed mesh was seeded with more than twice as many cells as unmodified PGA mesh. Vascular smooth muscle cells attached to the surface-hydrolyzed PGA mesh both as individual cells and as cell aggregates while only cell aggregates were observed on the unmodified mesh. Control experiments indicated that adsorption of serum proteins onto the surface-hydrolyzed PGA fibers was correlated with the increase in cell seeding density. These results demonstrate that optimization of biomaterial-cell interactions provides a strategy for increasing the initial cell seeding density for the engineering of tissues of high cell density.

Animals↗

A mobile computed tomographic scanner with intraoperative and intensive care unit applications.

INTRODUCTION: A mobile computed tomographic scanner has been developed in which the scan plane is selected by means of gantry translation, rather than by translation of the patient table. This permits computed tomographic scanning in situ of any patient who is positioned on a radiolucent surface that fits within the inner diameter of the gantry. We report the design of and initial experience with this scanner as used with adapters for intraoperative and bedside computed tomography (CT). METHODS: The scanner is equipped with wheels, draws power from wall outlets (120 V, 20 A) in combination with batteries, and has a translating gantry. Preclinical studies of image quality were performed with phantoms. An operating table adapter was built for use with a radiolucent cranial fixation device. A bedside adapter was built that holds the head and shoulders of a patient in the intensive care unit. RESULTS: The preclinical phantom studies showed satisfactory image spatial resolution (0.8 mm) and low-contrast resolution signal-to-noise relative standard deviation (0.37%). Experience to date with 12 patients has confirmed the feasibility of intraoperative CT on demand. Experience to date with 26 patients has confirmed the feasibility of routine bedside CT in the intensive care unit. CONCLUSION: With these adaptations, mobile CT may increase the efficiency of intraoperative scanning by making it available to multiple operating rooms without committing it to any room for an entire operation and may increase the efficiency and safety of CT of critically ill patients who currently need to leave the intensive care unit to travel to a fixed CT installation and back.

Child↗

Occupational radiation exposure to interventional radiologists: a prospective study.

This study investigates the occupational radiation dose to interventional radiologists and the operator-controlled factors that may affect dose. Thirty interventional radiologists wore radiation badges over and under lead aprons for 2 months and answered a questionnaire. The relationships between dose and caseload, case mix, experience, optional fluoroscopy features, lead apron type, and additional lead shielding were evaluated. Mean projected yearly dose (PYD) over lead was 49.1 mSv (1 mSv = 100 mrem) but was 66.6 mSv for persons performing 1,000 or more cases per year (P = .027). Mean PYD under lead was 0.9 mSv but was 1.3 mSv for persons with 0.5-mm lead coverage and 0.4 mSv for those with 1.0-mm lead coverage (P = .002). No other significant correlation was found. Conclusions are that caseload and apron thickness are the primary determinants of total body dose, that over-lead dose is high enough to warrant additional lead shielding for the head and neck, and that a double-thickness apron lowers under-lead dose by two-thirds. The large difference between under-lead and over-lead doses suggests that use of a collar badge alone for monitoring purposes is not predictive of total-body effective dose for this group of radiation workers.

Adult↗

Precision of hyaline cartilage thickness measurements.

Measurement of cartilage thickness in vivo is an important indicator of the status of a joint as the various degenerative and inflammatory arthritides directly affect the condition of the cartilage. In order to assess the precision of thickness measurements of hyaline articular cartilage, we undertook a pilot study using MR imaging, plain radiography, and ultrasonography (US). We measured the cartilage of the hip and knee joints in 10 persons (4 healthy volunteers and 6 patients). The joints in each patient were examined on two separate occasions using each modality. In the hips as well as the knee joints, the most precise measuring method was plain film radiography. For radiographs of the knees obtained in the standing position, the coefficient of variation was 6.5%; in the hips this figure was 6.34%. US of the knees and MR imaging of the hips were the second best modalities in the measurement of cartilage thickness. In addition, MR imaging enabled the most complete visualization of the joint cartilage.

Adult↗

Radiation exposure during radiofrequency catheter ablation of accessory atrioventricular connections.

BACKGROUND: Catheter ablation of accessory atrioventricular (AV) connections has been demonstrated to be effective in more than 85% of patients. One of the risks of this procedure is radiation exposure during the fluoroscopic imaging necessary to guide catheter manipulation. The objective of the present study was to measure the radiation received by patients and physicians during radiofrequency catheter ablation and to estimate the resultant somatic and genetic risks. METHODS AND RESULTS: Radiation exposure to patients and physicians was measured during attempts at radiofrequency catheter ablation of accessory AV connections in 31 consecutive patients. Radiation exposure was measured using thermoluminescent sensors placed on the patient and on the physician. Somatic and genetic risks were estimated based on the radiation levels recorded using these sensors. The durations of fluoroscopy and of the catheter ablation procedure were recorded for each patient. Catheter ablation was successful in 28 of 31 patients (90%). Mean +/- SD duration of fluoroscopy was 44 +/- 40 minutes. The largest patient radiation dose was measured over the ninth vertebral body posteriorly (median, 7.26 rem [roentgen equivalents man]; range, 0.31-135.7 rem). Median radiation dose to the thyroid was 0.46 rem (range, 0.06-7.26 rem), and median radiation dose to the posterior iliac crest was 2.43 rem (range, 0.01-8.3 rem). The greatest radiation dose to the operator was recorded at the left hand (99 mrem). Mean radiation dose to the operator's eyes was 28 mrem. CONCLUSIONS: Radiofrequency catheter ablation of accessory AV connections may result in significant radiation exposure to the patient and to the physician. Each hour of fluoroscopic imaging is associated with a lifetime risk of developing a fatal malignancy of 0.1% and a risk of a genetic defect of 20 per 1 million births. Although these risks must be recognized, they are relatively small compared with the risks associated with alternate approaches to management, including no therapy, antiarrhythmic drug therapy, and surgery.

Adolescent↗

Overview: new methods in imaging osteoarthritis.

The new imaging modalities, namely computed tomography (CT), magnetic resonance imaging (MRI), and ultrasonography (US) provide potentially powerful tools for in vivo assessment of osteoarthritis (OA), monitoring the progress of the disease and understanding its natural course. However, to use these tools effectively, we need more prospective research focused on correlating imaging data with biochemical and gross and microscopic pathologic findings. MRI is clearly the most powerful tool for demonstrating the various articular components which may be affected in OA. CT is excellent for delineating osseous abnormalities and with US we are able to evaluate the thickness and surface characteristics of those portions of articular cartilage that are accessible. The advantages and limitations of these 3 modalities are discussed as they pertain to OA of the hip and knee.

Arthrography↗

Measurement of ventilation and respiratory mechanics during continuous positive airway pressure (CPAP) treatment in infants.

A new method has been evaluated for measuring ventilation and lung mechanics in spontaneously breathing infants by means of a face chamber. Airway flow is measured with a pneumotachograph inserted between the face chamber and a stable pressure source. Oesophageal pressure is measured via a water-filled oesophageal catheter. The method is suitable for use in conjunction with continuous positive airway pressure (CPAP) treatment in neonatal intensive care. A flat frequency response curve up to 15 Hz for the two measuring systems (i.e., airway flow and oesophageal pressure), and a time shift between the two respective signals of less than 2 msec are prerequisites for correct evaluation of respiratory mechanics. In preterm infants with chest distortion, the inhomogeneity of pleural pressure affects the significance of resistance and compliance values, as calculated from oesophageal pressure. Supra-diaphragmatic pressure variations reflect the resistive and elastic load on the diaphragm exerted by the lungs and thorax. Thus, oesophageal pressure is still useful in studies of respiratory mechanics in preterm infants.

Apnea↗

On-line measurement of gas-exchange during cardiac surgery.

This paper describes an on-line system for continuously monitoring expired CO2 during controlled ventilation. Signals from a Servo ventilator 900B or C and a CO2 Analyzer 930 are processed and corrected by the computer to produce a CO2 single breath test (SBT-CO2). This is the tracing of expired CO2 concentration or fraction against expired volume, from which the computer calculates the airway deadspace (VDaw). If a value for arterial PCO2 is supplied, the computer will calculate the physiological deadspace (VDphys) and the alveolar deadspace (VDalv) for each breath. The system was used to make measurements at four stages during coronary artery by-pass grafting in 13 male patients. When the sternum was opened there was a 32% increase in VDaw, and the physiological deadspace fraction therefore increased. There were reductions in VDaw after extra-corporeal circulation and again after sternal suture. By the end of surgery, the alveolar deadspace fraction had increased significantly. VDaw at this stage was smaller than pre-operatively, and so there was no net change in the physiological deadspace fraction at the end of surgery. Arterial PO2 was, however, reduced at this stage.

Aged↗

Gas exchange during controlled ventilation in children with normal and abnormal pulmonary circulation: a study using the single breath test for carbon dioxide.

Carbon dioxide single breath tests (SBT-CO2) were obtained during anesthesia and controlled ventilation in 42 children about to undergo thoracic surgery. The tests were obtained with a computerized system based on the Servo ventilator. The system made on-line corrections for compressed volume, apparatus deadspace, and rebreathing. Children with normal pulmonary circulation had excellent gas exchange with high PaO2 values, a mean alveolar deadspace fraction (VDalv/VTalv) of 0.10, and a gently sloping phase III of SBT-CO2. Children with pulmonary hyperperfusion (left to right shunting) due to an atrial septal defect or a ventrical septal defect had significantly lower PaO2 values, steeper phase III slopes, and a greater spread of values for VDalv/VTalv. Children with pulmonary hypoperfusion due to pulmonary stenosis in combination with intracardiac right to left shunting had extremely low PaO2 values, and "adult" values for VDalv/VTalv. They required increased ventilation to maintain CO2 homeostasis. In the pooled material, the airway deadspace was strongly correlated to height, weight, and age. The airway deadspace was unaffected when tidal volume was increased by 37%, and ventilatory frequency simultaneously reduced by 30%, a maneuver that left alveolar ventilation unchanged. This is probably because an end-inspiratory pause was used; when frequency is reduced the length of the end-inspiratory pause increases, allowing proximal diffusion of the alveolar/fresh gas interface.

Anesthesia↗