PubMed Health⌕ Search

Biomedical subjects

L Nimb

Publications and source records attributed to L Nimb.

11 recordsLinked to original sources

[Bilateral Achilles tendon rupture in individuals with renal transplantation].

Increased incidence of tendinitis and tendon ruptures is reported in recipients of a kidney transplant. Two cases of bilateral achilles tendon rupture after minimal trauma are described. Tendon ruptures are more frequent in individuals with kidney disease in dialysis or after transplantation compared with patients receiving other organ transplantations. It is therefore more likely that tendon ruptures are related to metabolic changes associated with kidney disease rather than with transplantation or with glucocorticoid treatment per se. Clinical symptoms of achilles tendinitis should be considered as warning signs prior to tendon rupture and treated appropriately to avoid further morbidity. There is no contraindication towards surgical suturing of an achilles tendon rupture in patients receiving immunosuppressive treatment including glucocorticoids.

Achilles Tendon↗

Interface mechanics and histomorphometric analysis of hydroxyapatite-coated and porous glass-ceramic implants in canine bone.

A canine study was performed to make a histological and biomechanical evaluation of the interface between bone and two different bioceramic implants. A newly developed glass-ceramic formed by P2O5, CaO, SiO2, and Al2O3, giving a crystal phase composed of CaP2O6-AlPO4-SiP2O7, was compared to hydroxyapatite (HA) coated Ti-6Al-4V implants. A total of 24 implants were inserted into the femoral condyle of 15 adult female golden retriever dogs weighing 20-25 kg. There was a 12 week follow-up. Implants were examined by mechanical testing, histology, histomorphometry, microradiograpic methods, and EDAX analysis. The ultimate shear strength for the HA-coated implants was significantly higher than in the glass-ceramic group. When these values were related to the histomorphometric measurements, the difference could be explained by the tissue-to-implant contact. The glass-ceramic showed direct contact only with nonmineralized, osteoid bone. The HA-coated implants, however, were integrated into the bone. The study indicated that porous glass-ceramic containing AlPO4 causes local osteomalacia and might not be suitable for clinical purposes.

Alloys↗

Blood perfusion and remodelling activity in canine tibial diaphysis after filling with a new bone cement compared to bone wax and poly(methyl methacrylate) cement.

Six dogs each had one tibia filled with standard poly(methyl methacrylate) (PMMA) bone cement and the contralateral tibia filled with a new methyl methacrylate-n-decyl methacrylate-isobornyl methacrylate (MMA-DMA-IBMA) bone cement (Boneloc) with lowered polymerization heat and monomer leakage. An additional six dogs each had one tibia filled with MMA-DMA-IBMA and the contralateral tibia filled with bone wax. There was a higher diaphyseal blood flow, measured with a microsphere technique, in the legs filled with MMA-DMA-IBMA than in those filled with PMMA. The wax-filled bones presented higher blood perfusion than those with MMA-DMA-IBMA. We found a tendency towards higher 99mtechnetium-labelled methylene diphosphonate (99mTcMDP) uptake, and autoradiograms revealed a tendency towards larger subperiosteal apposition and more blackening, both at the subperiosteal apposition and the cortex, in the bones filled with new bone cement in the first series, but in wax-filled bone in the second series. It is concluded that the new bone cement, compared to standard acrylic bone cement, seems to inhibit the vascular response and bone remodelling activity less, making earlier remodelling possible. However, the new bone cement still seems to inhibit bone blood perfusion compared to bone wax.

Animals↗

Immediate implant placement using a biodegradable barrier, polyhydroxybutyrate-hydroxyvalerate reinforced with polyglactin 910. An experimental study in dogs.

The purpose of this study was to evaluate the use of a biodegradable membrane of polyhydroxybutyrate-hydroxyvalerate copolymer reinforced with polyglactin 910 fibers, as an occlusive barrier over implants placed into fresh extraction sockets. Ten dogs had the 3rd and 4th mandibular premolars extracted bilaterally. Each dog had 4 Astra Dental Implants placed directly into the fresh extraction sockets. The top of the fixtures was placed at the same level as the top of the buccal cortical bone. The two implants in the right side were covered with the hydrolyzable polyester material (polyhydroxybutyrate-hydroxyvalerate reinforced with polyglactin 910 fibers; PHB-HV/PG), and the 2 implants in the left side were controls without occlusive membranes. Soft tissue dehiscences were registered for half of the implants in the test side but were not noted in the control side. The histomorphological measurements after 12 weeks showed that the mean distance from the top of the fixtures to the first bone-to-implant contact was significantly greater than for the control side. The membrane-covered implants without dehiscences showed also significantly less bone fill compared with the control side. Inflammatory cell infiltrates were seen adjacent to all PHB-HV/PG membranes, and frequently the membrane material was surrounded by a fibrous tissue capsule. The polyester membranes used in this study interfered with the marginal bone healing adjacent to the immediately placed implants. An increased inflammatory reaction and significantly less marginal bone healing was registered in the membrane side compared with the control side.

Animals↗

Effects of polymerization heat and monomers from acrylic cement on canine bone.

We investigated the effects of polymerization heat and toxicity of polymethylmetacrylate bone cement in the canine tibial diaphysis. Heat was studied by filling the tibias with either bone cement or bone wax contained in a monomer tight membrane pouch. Toxicity was studied by filling both tibias with cement, with the control side contained in the membrane pouch. Bone blood perfusion was measured by microsphere technic, and bone remodeling by 99mTc-methylene diphosphonate uptake and by histologic technique. In bone exposed to the combination of polymerization heat and monomer, both perfusion and remodeling were impaired. We did not find any effects of polymerization heat alone. We conclude that hot toxic chemicals from bone cement during polymerization may inhibit bone blood perfusion and remodeling, whereas heat alone seems to be of minor importance for the regenerative processes in cemented diaphyseal bone.

Animals↗

Improved cortical histology after cementation with a new MMA-DMA-IBMA bone cement: an animal study.

The histological response of bone to inert bone wax, conventional polymethylmethacrylate (PMMA), and a new formulation of bone cement, methylmethacrylate/n-decylmethacrylate/isobornylmethacrylate (MMA/DMA/IBMA) was investigated in canine tibial diaphysis. The new formulation of cement is characterized by a reduced exothermic temperature at curing and reduced leakage of chemicals to the adjacent bone. In comparison with bone wax, the MMA/DMA/IBMA bone cement did not differ significantly with respect to periosteal apposition and bone remodeling, although a tendency to inhibit the biological response was encountered. The MMA/DMA/IBMA was clearly superior to PMMA bone cement in respect to both bone necrosis and repair, as well as bone remodeling.

Animals↗

Evaluation of guided bone generation around implants placed into fresh extraction sockets: an experimental study in dogs.

Immediate placement of implants into fresh extraction sockets would have the principal advantage of decreasing the recommended period of healing. It also would result in a guided placement of the implant, and it could reduce the resorption of the alveolar bone in the extraction area. However, when an implant is placed immediately into an extraction socket, it may not engage the walls of the socket near the crest of the alveolar ridge. With the presence of a bone defect around an implant, ingrowth of soft tissue could compromise the achievement of osseointegration in the crestal bone area. The objective of this study was to evaluate the crestal bone healing response adjacent to implants placed immediately into fresh extraction sockets with and without covering membranes. Eight adult mongrel dogs had the third and fourth mandibular premolars extracted bilaterally. Thirty-two submerged titanium hollow-screw implants were inserted immediately into the extraction sockets. On the right side, the implants were covered with an expanded polytetrafluorethylene membrane, whereas the left side served as a control. One dog was killed after 2 weeks, one after 4 weeks, and six after 12 weeks. Soft tissue dehiscence developed over 10 implants (12-week dogs) covered with membranes. Dehiscence was noted histologically over three contralateral control implants. When soft tissue dehiscence occurred and the membrane was left exposed without oral hygiene during healing, the degree of bone integration was significantly less than in the control sites without membranes.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Mechanical failure of hydroxyapatite-coated titanium and cobalt-chromium-molybdenum alloy implants. An animal study.

Defects in the hydroxyapatite (HA) ceramic coatings applied to metallic implant systems may occur at the time of insertion or at the time of in vivo loading. However, defects may also occur with time because of interaction with physiological fluids. A canine study was performed to make a histological and biomechanical evaluation of HA-coated titanium and cobalt-chromium-molybdenum alloy implants in a non-weight-bearing model. Twelve cylindrical plugs were inserted into the medial femoral condyle on 6 mongrel dogs. HA-coatings of 80-120 microns thickness were applied to 6 Cr-Co-Mo implants and 6 Ti-6AI-4V implants. The implants were removed together with adjacent bone tissue after 4 weeks. There were no statistically significant differences between the two groups for interface shear strength. No differences were encountered with HA-coating on Cr-Co-Mo or on Ti-6AI-4V, failure consistently being caused by disruption between the metal surface and the HA-coating, which remained fixed to the bone. At histologic evaluation the HA-coated implants exhibited a great amount of direct bone-to-implant contact. In spite of that, this study indicates that HA-coating on smooth metal surfaces might not be suitable for clinical use, because of low bonding strength between metal and coating.

Alloys↗

Variation of cortical hypertrophy depending on the medullary filling material. An experimental study of canine tibial diaphysis.

In order to evaluate the mineralization of bone after polymethyl methacrylate cementation, measurements of the periosteal apposition were made histologically and measurements of the bone-mineral content were made by dual-photon absorptiometry of the tibial diaphysis in 15 adult mongrel dogs in paired studies. Six dogs were investigated 4 weeks after intramedullary reaming of both sides and obturation of the medullary cavity with bone-wax on one side. Nine dogs were reamed on both sides. The medullary cavities were filled with polymethyl methacrylate bone-cement and bone-wax, respectively. The authors found (1) an increased bone-mineral content and an increased periosteal apposition after filling with bone-wax in comparison with the reamed side and (2) a decreased bone-mineral content and a decreased periosteal apposition on the cemented side in comparison with bone-wax. These findings are interpreted as consequential upon repair processes with a high remodeling and mineralization rate after reaming or filling with bone-wax, whereas remodeling in inhibited after filling with acrylic bone-cement.

Absorptiometry, Photon↗

Histomorphometric and removal torque analysis for TiO2-blasted titanium implants. An experimental study on dogs.

The aim of the present study was to compare the anchorage of TiO2-blasted screw and cylindrical implants with conventionally used machine-produced screw and cylindrical implants inserted immediately in extraction sockets on dogs. 6 adult mongrel dogs had 3rd and 4th mandibular premolars extracted bilaterally and 24 commercial pure titanium implants were placed immediately in extraction sockets and covered with mucoperiosteum. Each dog had inserted 4 implants: 1 screw implant and 1 cylindrical implant blasted with titanium-dioxide-particles; 1 screw implant and 1 cylindrical implant with machine-produced (m.p.) surface (controls). After a healing period of 12 weeks, 16 implants from 4 animals were used for removal torque test, which demonstrated that significantly higher removal torque force was needed to unscrew the implants blasted with titanium-dioxide-particles, than the normal m.p. implants. The medians for the TiO2-blasted screw and cylindrical implants were > 150 Ncm and 105 Ncm, respectively, while the values for the m.p. implants were 60 Ncm and 35 Ncm, respectively. The SEM investigation demonstrated a high irregularity of the TiO2-blasted surface compared to the machined surface. The Ra and Rz values for surface roughness were higher for the TiO2-blasted implants than for the normal m.p. implants. Histomorphometrically, the arithmetic mean of the direct bone-implant contact fraction was 69%. There was no significant difference in direct bone-implant contact length fraction between TiO2-blasted implants and the control implants. The implants blasted with titanium-dioxide-particles in this study showed a better anchorage than implants with a machine-produced surface. The screw implants showed a better anchorage than the cylindrical implants.

Animals↗

The effect on cortical bone of reaming and filling of canine tibial diaphysis with inert bone wax.

In canine studies the effect of intramedullary reaming on tubular bone was investigated in 4 dogs. Intramedullary reaming was further compared with reaming and intramedullary filling with bone wax in 6 dogs. Bone blood perfusion was measured by a microsphere technique and bone remodelling activity by 99mTc-MDP uptake. From histological sections bone necrosis and remodelling activity were estimated. The biological response increased with the surgical trauma. If the medullary cavity was only reamed, endosteal apposition was the predominant reaction. Obturation of the medullary cavity resulted in more vigorous subperiosteal and cortical reaction. It is concluded that the remodelling processes differ significantly between reamed bone and bone where the medullary cavity is reamed and blocked. Thus when testing bone cement the studies should include a control operation with obturation of the medullary canal in a way simulating bone cement.

Animals↗