Impact of protein measurements on standardization of assays of apolipoproteins A-I and B1.

In 1989 the Committee on Apolipoproteins of the International Federation of Clinical Chemistry and the Centers for Disease Control conducted an international survey of total-protein measurements of isolated low-density lipoproteins (LDL) and delipidated high-density lipoproteins (HDL), and of their relationships to the National Institute of Standards and Technology (NIST) bovine serum albumin (BSA) Standard Reference Material (SRM). Most of the 93 apolipoprotein laboratories surveyed use the Lowry total-protein method. Results reported with the LDL preparations demonstrated a large bias and variation among methods; those with delipidated HDL were not as great, but were similar to those for BSA. Performance improved appreciably with use of the Lowry-sodium dodecyl sulfate method and the NIST BSA SRM for protein measurement. The total CVs, including among-laboratory and within-laboratory errors, averaged approximately 50% and 23% for LDL, 17% and 11% for HDL, and 18% and 11% for BSA solutions by all methods and by the Lowry methods, respectively. Regardless of the methods used, greater variability of the protein measurements was seen with the normally occurring LDL than with the nonlipoprotein BSA or delipidated HDL. The mean CV values for all samples among laboratories averaged between 10% and 15% with the modified Lowry methods; the biuret method gave the highest among-laboratory CV, 34%; the Kjeldahl had the lowest, 7.7%. Use of the same methodology and primary nonapolipoprotein standard is essential for comparability of protein results for apolipoprotein primary standard solutions. This is especially true for apolipoprotein B, because its inherent properties and lability make protein analysis difficult. This study supports the use of a standardized selected Lowry-sodium dodecyl sulfate method traceable to quantitative amino acid analysis as a point of reference for determining the protein concentration of primary calibration reference materials for apolipoproteins.

Apolipoproteins A↗

Model system evaluating fluorescein-labeled microbeads as internal standards to calibrate fluorescence intensity on flow cytometers.

Fluorescence intensity calibration was evaluated in a model system for flow cytometers using commercially available fluorescein-labeled microbeads as internal standards and stabilized fluoresceinated thymus cell nuclei (Fluorotrol) as surrogates for stained mononuclear cells. Spectrophotometrically determined calibration values for the microbeads were used to generate a standard curve that converted green fluorescence histogram channels into molecular equivalents of soluble fluorescein (MESF). In 19 analyses repeated during a single run, the coefficients of variation (CVs) for the derived MESF values on both dimly and brightly stained Fluorotrol populations were less than 2%. In 26 separate determinations over 14 weeks, the CVs of the derived MESF values were less than 3%. The MESF values of the dim and bright Fluorotrol populations derived from the microbead standard curves were both about 50% lower than those determined by direct spectrophotometric analysis of Fluorotrol. The analytical imprecision of fluorescence intensity measurements in this idealized model system has a CV less than 3%, and the analytical inaccuracy shows that calibration in MESF units remains uncertain over about a two-fold range.

Animals↗

Preparation of lyophilized human serum based reference materials with graded levels of apolipoproteins A-I and B.

Surveys of national and international laboratories indicate that among-laboratory and between-laboratory sources of variance account for the majority of variability in laboratories measuring apolipoproteins A-I and B. These sources of variance are amenable to correction through the use of common quality control and reference materials. We utilized proven techniques employing ethyl alcohol and acetate buffer to precipitate either apolipoprotein A-I rich or apolipoprotein B rich fractions that were blended with whole or delipidated serum producing five pilot-sized pools containing graded levels of apolipoproteins. After lyophilization the pools were tested and each pool contained levels of analytes similar to frozen serum and contained varied amounts of apolipoproteins A-I and B. Temporal and accelerated thermal stability testing demonstrated stability of the analytes in the pools with time (three years) and temperature (up to 56 degrees C). This technology provides a preparative procedure for apolipoprotein reference materials over the extended range needed in clinical applications.

Apolipoprotein A-I↗

An evaluation of the trends in analytical performance of international apolipoprotein A-1 and B assays.

Two international apolipoprotein A-1 and B (apoA-1 and apoB) surveys were conducted in 1983 and 1986 with use of a lyophilized serum measured by 55 and 91 participants, respectively. The chief source of variability in both surveys was among laboratories, but among-method variation was significant for apoB. Comparing the 1986 with the 1983 findings, we saw a 60% decrease in apoA-1 variability among laboratories, and a similar decrease (53%) was found for apoB. Evaluation of individual measurements suggests that some collaborators may have adjusted their calibrators toward the consensus values published in 1983.

Apolipoprotein A-I↗

High-density lipoprotein apolipoproteins in urine: I. Characterization in normal subjects and in patients with proteinuria.

A high-resolution two-dimensional electrophoretic method for protein, with silver staining, has been used to characterize and identify urinary high-density-lipoprotein apolipoproteins (HDL-Apos) and their isoforms in healthy subjects and in patients with kidney disease. Analytical techniques based on both molecular mass and ultracentrifugal flotation properties were used to isolate urinary lipoprotein particles with characteristics identical to those of HDL in plasma. HDL-Apos identified in urine of normal subjects and patients with glomerular proteinuria were Apos A-I, A-II, and C. Five isoforms of Apo A-I were present. Immunostaining of electroblotted proteins further confirmed the presence of HDL-Apos in urine. Creatinine clearance rate was decreased in the patients with proteinuria, and ranged from 32.5 to 40 mL/min. Concentrations of cholesterol and triglycerides in serum were greater in the patients' group, whereas mean HDL-cholesterol (0.68, SD 0.10 mmol/L) and Apo A-I (0.953, SD 0.095 g/L) were significantly (each P less than 0.01) lower. Results of this study suggest that measurement of urinary Apo A-I will reflect excretion of HDL in urine.

Apolipoprotein A-I↗

High-density lipoprotein apolipoproteins in urine: II. Enzyme-linked immunoassay of apolipoprotein A-I.

We have developed a capture antibody, noncompetitive, enzyme-linked immunoassay for urinary apolipoprotein A-I (Apo A-I) in urine, with use of affinity-purified polyclonal antisera against Apo A-I. A 96-well microtiter plate format is used, with unconcentrated urine as sample and dilutions of serum or high-density lipoprotein (HDL) as standards. The intra- and interassay variation (CV) averaged 7.4% and 9.4%, respectively. The limit of detection is low (1.25 ng/L), and no cross-reactivity with Apo B, C, E, or A-II was detected. The mean (+/- SD) concentrations of Apo A-I in urine of patients with glomerular proteinuria were a thousandfold greater (38.4 +/- 23.1 mg/L) than in normal subjects (16.3 +/- 11.3 micrograms/L in men, 17.97 +/- 7.7 micrograms/L in women, a significant difference, P less than 0.001). Apo A-I measurements correlated very well (r = 0.92) with selectivity index assessment. The diurnal variation of the concentration of Apo A-I in urine appears to result from dilution related to fluid intake. This enzymatic method is easy to perform, can be used with large numbers of samples, and is adaptable for use in the routine clinical laboratory. The method holds promise for discriminating between normal and subclinical kidney disease populations by measuring the concentrations of urinary Apo A-I excreted on HDL particles.

Adolescent↗

Quantitative differences among various proteins as blocking agents for ELISA microtiter plates.

We tested instantized dry milk, casein, gelatins from pig and fish skin, serum albumin and several other proteins for their abilities to block non-specific binding (NSB) of a peroxidase-conjugated immunoglobulin to polystyrene microtiter plate wells. Each blocking protein was tested across a million-fold concentration range, both in simultaneous incubation with the peroxidase conjugate and as a pretreatment agent where excess protein was washed away before incubation with the conjugate. Overall, instantized milk and casein were the most effective proteins tested: they inhibited NSB by over 90% in both the simultaneous and pretreatment modes at far lower concentrations than most of eight other proteins. Enzymatically hydrolyzed porcine skin gelatin was the least effective protein tested: it did not reduce NSB by more than 90% even at its highest concentrations; its blocking ability fell rapidly upon dilution; and it was almost useless as a pretreatment agent. Fish skin gelatin showed much better blocking activity than hydrolyzed porcine gelatin, and it still had the practical advantage of remaining fluid even under refrigeration. Our results suggest that some proteins (such as casein) block NSB to plastic primarily through protein-plastic interactions, while others (such as porcine skin gelatin) block primarily through protein-protein interactions. Although the optimal blocking agent for any particular ELISA system must be determined by empirical testing, these results should be helpful in selecting the best possible candidate proteins for further evaluation.

Animals↗

An international collaborative study on standardization of apolipoproteins A-I and B. Part I. Evaluation of a lyophilized candidate reference and calibration material.

We evaluated a lyophilized serum preparation for use as a candidate Reference Material for apolipoproteins (apo) A-I and B. An international collaborative study was conducted with 28 participating laboratories, selected on the basis of participation and demonstrated expertise in a 1983 survey of apolipoproteins A-I and B. The analytical suitability of the material was established by confirming linearity of its dose-response curves over a desired concentration range and demonstrating that its response curves paralleled those for fresh sera. Differences in dilution-adjusted mass units ascribable to the five analytical methods used by the various laboratories constituted only 1% of the total variation for apo A-I, but 32% for apo B. The dominant source of error, however, for both apo A-I and B was the variability among laboratories, rather than variability among methods and antisera. The assigned consensus mass-concentration units based on study data are 1.124 g/L for apo A-I, 0.589 g/L for apo B. For these estimates the coefficients of variation were 13% and 27%, respectively. These findings on the proposed Reference Material meet the requirements suggested by the World Health Organization's Expert Committee on Biological Standards for a candidate WHO Reference Preparation.

Apolipoprotein A-I↗

An international collaborative study on standardization of apolipoproteins A-I and B. Part II. Evaluation of contributions of antisera to among-laboratory variance components.

Local antisera (LA) were compared with a common interim reference antiserum (IRA) to examine the antiserum component of the among-laboratory variation in an international collaborative study with 28 laboratories evaluating a candidate international Reference Material (apo-RM) for apolipoproteins A-I (apo A-I) and B (apo B). Measurement of the relative concentration of lyophilized preparations differed by less than 1% for LA and IRA. The percentage of the total variation in measurement of the concentration of apo-RM that was contributed by antisera among laboratories was 5% and 8% for apo A-I and B, respectively. Estimated differences from overall mean concentrations for the five different immuno-methods were greater for apo B (range: +22% to -23.5%) than for apo A-I (range +14% to -14%), but were similar within a method for LA and IRA. The results indicated that antisera are not a major source of error among laboratories and, indeed, are responsible for relatively little of the total variability.

Apolipoprotein A-I↗

Contrasting short- and long-term effects of weight loss on lipoprotein levels.

The short- and long-term effects of weight loss on high-density lipoprotein (HDL) and low-density lipoprotein (LDL) cholesterol levels were examined in 42 women who completed a 14-session behavioral weight-loss program. Lipid values were determined from samples taken before treatment, after treatment, and at six-month follow-up. There were significant changes in plasma lipid levels, but the short- and long-term effects differed. Both total and LDL cholesterol levels decreased during treatment and remained lower at follow-up. However, HDL cholesterol level and the HDL/LDL ratio did not change during treatment but increased significantly above pretreatment levels at follow-up. Furthermore, long-term changes in lipoprotein levels were significantly correlated with changes in the body-mass index even after correction for initial values. These results show that weight loss can, in the long term, have a potentially beneficial impact on lipoprotein levels in women.

Behavior Therapy↗

Exercise, diet, or physical characteristics as determinants of HDL-levels in endurance athletes.

Serum lipids, lipoproteins, apolipoproteins, physical characteristics, and 10-day dietary records of 20 male distance runners (aged 20-42 years) were compared with those of 14 sedentary controls (aged 23-34 years). Runners had significantly greater levels (mean +/- SD) of high density lipoproteins (HDL) whether estimated as HDL-cholesterol (66 +/- 12 vs 46 +/- 10 mg/dl) or as the major HDL apolipoproteins, apoA-I (170 +/- 36 vs 124 +/- 27 mg/dl) or apoA-II (39 +/- 5 vs 34 +/- 4 mg/dl). Runners were leaner with considerably less body fat (8.3 +/- 1.7 vs 16.2 +/- 3.9%) than the sedentary men despite consuming 20% more calories. Moreover, the additional calories consumed were largely carbohydrate. This comparison illustrates that high absolute quantities of dietary carbohydrate do not depress HDL levels in lean individuals engaged in exercise training. Furthermore, the results suggest that dietary factors may be as important as exercise itself in producing the lipoprotein pattern characteristic of endurance athletes.

Adult↗

Effects of propranolol on blood lipids and lipoproteins in myocardial infarction.

The effects of propranolol on lipids and lipoproteins were investigated in survivors of a recent myocardial infarction who were enrolled in the double-blind Beta-Blocker Heart Attack Trial. Nonfasting serum samples were obtained in more than 2800 patients assigned randomly to either propranolol or placebo. The propranolol-treated group had high-density lipoprotein cholesterol levels 3-4 mg/dl less and triglyceride concentrations 30-40 mg/dl higher than the placebo group. These effects occurred in men and women in all age categories.

Adult↗

Quantitative determination of human plasma apolipoprotein A-I by laser immunonephelometry.

A technical procedure is described for quantitation of human apolipoprotein A-I (apo A-I) in normal plasma or serum by immunonephelometry. Dilution of the plasma samples with 6 mol/L guanidine chloride ensures maximum exposure of the antigenic sites of the apoprotein and enables optimum quantitation of the apo A-I without requiring extraction with organic solvents. Similar data are obtained by this assay and with radioimmunoassay for normal subjects (1.2--1.5 g/L), and the results obtained on 31 patients are correlated with a coefficient of 0.92. The apo A-I values are correlated with values for plasma high-density lipoprotein cholesterol (r = 0.64). The interassay CV for immunonephelometry is about 7% and the standard curve is linear between 0.1 and 1.0 microgram of apo A-I per sample, corresponding to a 150-fold dilution of serum or plasma. The assay is applicable to plasma samples containing as much as 4 g of triglycerides per liter. At higher concentrations plasma delipidation is required.

Adult↗

Acute effects of prolonged exercise on serum lipids.

The acute effects of a single prolonged exercise session on the serum concentrations of cholesterol, triglycerides (TG), glycerol, high density lipoprotein (HDL) cholesterol, and the major HDL protein, apolipoprotein A-I(apoA-I), were examined in 12 trained male runners participating in a 42-km footrace. Serum TG levels were unchanged up to 4 h after the race, but at 18, 42, and 66 hr mean reductions of 65%, 39%, and 32% were observed. Free glycerol concentrations were increased fivefold immediately after the race, but did not differ from prerace levels by 4 hr. Total cholesterol concentration did not change immediately after exercise, but unexpected significant reductions of 6%-10% were found at 4-66 hr. Only small and transient increases in HDL cholesterol and apoA-I levels were noted after exercise. These results suggest that prolonged exercise acutely lowers TG and total cholesterol, but has little effect on HDL mass.

Adult↗

Artifactual reduction of high-density lipoprotein cholesterol estimates after dextran sulfate--Mg2+ precipitation.

Estimates of serum or plasma high-density lipoprotein (HDL) concentrations are usually accomplished by measuring the residual cholesterol after polyanionic precipitation of the very low and low-density lipoproteins. A comparison was made of the HDL cholesterol values obtained using both heparin--MnCl2 and dextran sulfate--Mg2+ as precipitating agents. Enzymatic cholesterol determinations showed that the dextran sulfate--Mg2+ method led to gross underestimation of the serum HDL cholesterol concentration (approximately -25%), a difference that was even greater when ultracentrifugally isolated HDL concentrations were assayed rather than serum. Immunochemical determinations of the A-I and B apolipoproteins demonstrated that the discrepancy was attributable neither to incomplete precipitation of the lower density lipoproteins by heparin--MnCl2 nor to precipitation of HDL by dextran sulfate--Mg2+. Incubation of sera with reagents at 37 C, however, minimized or eliminated the differences in results. These findings indicate that temperature is a critical factor when enzymatic quantification of HDL cholesterol is performed after dextran sulfate--Mg2+ precipitation.

Chemical Precipitation↗

Minimal within-day variation of high density lipoprotein cholesterol and apolipoprotein A-I levels in normal subjects.

Blood was drawn from twenty normal hospital employees after a 12-14 hr fast (9:30 AM), and at 4 hr (1:30 PM) and 7 hr (4:30 PM) thereafter while test subjects consumed their habitual diet. Absorptive chylomicronemia was reflected in average triglyceride increases of 30% and 53% at 4 hr and 7 hr, respectively. No significant changes in total (< 1%) and high density lipoprotein (< 0.1%) cholesterol concentrations were observed. Moreover, levels of the major high density lipoprotein apolipoprotein, apoA-I, varied by less than 3%. Blood samples, randomly obtained during standard working hours, appear adequate for quantitation of high density lipoprotein cholesterol and apolipoprotein A-I levels.