PubMed Health⌕ Search

Biomedical subjects

L O Schilling

Publications and source records attributed to L O Schilling.

4 recordsLinked to original sources

Neuromonitoring and neurocognitive outcome in off-pump versus conventional coronary bypass operation.

BACKGROUND: Cardiopulmonary bypass seems to be a major cause for both intraoperative microemboli and cerebral hypoperfusion. This study investigates high intensive transient signals (HITS) in transcranial Doppler ultrasound (TCD) and serum levels of the neurobiochemical marker protein S-100 in patients who underwent coronary artery bypass operation without cardiopulmonary bypass (off-pump CABG) in comparison with the conventional procedure using cardiopulmonary bypass (CPB). The results are related to the neuropsychologic outcome in both surgical groups. METHODS: Forty patients were randomized in 2 groups (20 conventional and 20 off-pump CABG). Neurocognitive status was assessed preoperatively and postoperatively. Venous serum levels of S-100 protein were measured before and after coronary operation, HITS were measured in the middle cerebral artery during the operation. RESULTS: The median value of HITS was 394.5 (0 to 2217) in the conventional versus 11 (0 to 50) in the off-pump group, p less than 0.0001. Postoperative S-100 serum levels were: 3.76 (0.13 to 11.2) microg/L (conventional) versus 0.13 (0.04 to 1.01) microg/L (off-pump), p less than 0.0001. Postoperative cognitive testing showed significantly different results with a postoperative impairment of 90% of the patients in the conventional group versus no impairment in the off-pump group. CONCLUSIONS: Cognitive impairment seems to be strongly associated to CPB and the occurrence of micro-emboli. The off-pump technique appears to be promising in order to eliminate the source of these neuropyschologic impairments following CABG operation.

Cardiopulmonary Bypass↗

The Leipzig experience with robotic valve surgery.

OBJECTIVES: The study describes the single-center experience using robot-assisted videoscopic mitral valve surgery and the early results with a remote telemanipulator-assisted approach for mitral valve repair. MATERIAL AND METHODS: Out of a series of 230 patients who underwent minimally invasive mitral valve surgery, in 167 patients surgery was performed with the use of robotic assistance. A voice-controlled robotic arm was used for videoscopic guidance in 152 cases. Most recently, a computer-enhanced telemanipulator was used in 15 patients to perform the operation remotely. RESULTS: The mitral valve was repaired in 117 and replaced in all other patients. The voice-controlled robotic arm (AESOP 3000) facilitated videoscopic-assisted mitral valve surgery. The procedure was completed without the need for an additional assistant as "solo surgery." Additional procedures like radiofrequency ablation and tricuspid valve repair were performed in 21 and 4 patients, respectively. Duration of bypass and clamp time was comparable to conventional procedures (107 A 34 and 50 A 16 min, respectively). Hospital mortality was 1.2%. Using the da Vinci telemanipulation system, remote mitral valve repair was successfully performed in 13 of 15 patients. CONCLUSION: Robotic-assisted less invasive mitral valve surgery has evolved to a reliable technique with reproducible results for primary operations and for reoperations. Robotic assistance has enabled a solo surgery approach. The combination with radiofrequency ablation (Mini Maze) in patients with chronic atrial fibrillation has proven to be beneficial. The use of telemanipulation systems for remote mitral valve surgery is promising, but a number of problems have to be solved before the introduction of a closed chest mitral valve procedure.

Adult↗