PubMed Health⌕ Search

Biomedical subjects

L P Li

Publications and source records attributed to L P Li.

At least 19 recordsLinked to original sources

Prediction of recovery from a post-traumatic coma state by diffusion-weighted imaging (DWI) in patients with diffuse axonal injury.

INTRODUCTION: To determine whether diffusion-weighted magnetic resonance (MR) imaging findings combined with initial clinical factors indicate the depth of shearing lesions in the brain structure and therefore relate to coma duration in diffuse axonal injury (DAI). METHODS: A total of 74 adult patients (48 male and 26 female) with DAI were examined with conventional MR imaging and diffusion-weighted MR imaging between 2 hours and 20 days after injury. Apparent diffusion coefficient (ADC) maps were obtained and the mean ADC values of each region of interest (ROI) were measured using MRI console software. The involvement of the brainstem, deep gray matter, and corpus callosum was determined for each sequence separately as well as for the combination of all sequences. The correlations between MR imaging findings indicating the presence of apparent brain injury combined with initial clinical factors were determined. RESULTS: Clinical characteristics, such as initial score on the Glasgow coma scale (GCS), age and number of all lesions, and ADC scores were predictive of the duration of coma. CONCLUSION: It was possible to predict post-traumatic coma duration in DAI from cerebral MR imaging findings combined with clinical prognostic factors in the acute to subacute stage after head injury. Age, ADC scores, GCS score and number of lesions were highly significant in predicting coma duration. The technique presented here might provide a tool for in vivo detection of DAI to allow the prediction of the coma duration during the early stages in patients with traumatic brain injury.

Accidents, Traffic↗

Evaluation of intra-renal oxygenation during water diuresis: a time-resolved study using BOLD MRI.

Hypoxia of the renal medulla is a possible precursor to the onset of acute renal failure in humans and therefore an understanding of the factors influencing the oxygenation status within the renal medulla is very important. Blood oxygenation level-dependent (BOLD) magnetic resonance imaging (MRI) has been shown to non-invasively evaluate intra-renal oxygenation levels of the renal medulla in humans. A newly implemented three-dimensional (3-D) multiple gradient-recalled echo sequence, which permits examination of temporal responses to physiological or pharmacological stimuli, was used to monitor changes in intra-renal oxygenation status during water diuresis. Five healthy, young subjects (22+/-1.2 years) took part in the study. BOLD MRI data were acquired before and after water loading. Studies were repeated on a separate day after the subjects were pretreated with naproxen. Water diuresis significantly improved renal medullary oxygenation levels in all subjects (pre-waterload=30.3 1/s vs post-waterload 22.8 1/s); however, the temporal response was found to be subject dependent. In the presence of cyclooxygenase (COX) inhibition by naproxen, the improvement in oxygenation during water diuresis was completely abolished (pre-waterload=27.5 1/s vs post-waterload 28.5 1/s). Monitoring of temporal responses for the first time during water loading allowed for an appreciation of subject dependence. Comparison of the temporal response in terms of slopes demonstrated a significant difference between the waterload studies with and without naproxen (with naproxen=0.056 1/(s min) vs without naproxen=0.25 1/(s min)). The observed effects of naproxen were consistent with previous findings with COX inhibition.

Adult↗

Arthroscopic evaluation of cartilage degeneration using indentation testing--influence of indenter geometry.

BACKGROUND: It has been suggested that the early onset of cartilage degeneration might be detected with a handheld indentation probe during knee arthroscopy, prior to any visible change on the articular surface. Collagen degradation has been considered as the first sign of cartilage degeneration. Therefore, it is important to consider the collagen network as a distinct constituent in the study of arthroscopic evaluation of cartilage degeneration. METHODS: The tip of an arthroscopic probe (indenter) was modeled as rigid and in contact with a cartilage/bone disk of sufficiently large radius to simulate an indentation in a joint. A fibril-reinforced model of cartilage, including streaming potentials and distinct constitutive laws for the proteoglycan matrix and collagen network, was used to determine the contact mechanics of indenter and cartilage. The finite element package ABAQUS was employed to obtain numerical solutions. FINDINGS: A spherical indenter produces a relatively uniform deformation in cartilage, but can easily slide on the articular surface. In contrast, a cylindrical indenter produces great deformation gradients for quick compression rates, but does not slide as easily on the articular surface as the spherical indenter. Small porous and large solid indenters should be used to evaluate the properties of the proteoglycan matrix and collagen network, respectively, in order to minimize or maximize the fluid pressure in the corresponding case. When the collagen network is substantially degraded, the gradients of fluid pressure and deformation are greatly reduced regardless of indenter geometry. INTERPRETATION: The indenter geometry including its porosity is important to the material safety of articular cartilage in indentation and precise evaluation of cartilage degeneration.

Arthroscopy↗

L-Arginine treatment for asymmetric fetal growth restriction.

OBJECTIVES: [corrected] To investigate the effects of L-Arginine in treating asymmetric fetal growth restriction (FGR). METHODS: A total of 66 pregnant women whose fetuses were diagnosed with asymmetric fetal growth restriction were divided into two groups. Group 1 consisted of 36 women who were given routine therapy alone; group 2 consisted of 30 women who were given L-Arginine and routine therapy; and the control group consisted of 30 more women with a normal pregnancy. RESULTS: Before treatment, mean maternal serum levels of NO2-/NO3- were significantly lower in groups 1 and 2 than in the control group (P<0.01). After treatment, maternal serum levels of NO2-/NO3- were considerably higher in group 2 than in group 1 (P<0.01). Mean birth weight was significantly higher in group 2 than in group 1 (P<0.05), but still lower in group 2 than in the control group (P<0.01). CONCLUSIONS: A deficiency in nitric oxide may play an important role in the development of asymmetric fetal growth restriction. L-Arginine can be used to increase maternal NO2-/NO3- levels and newborn birth weight.

Adult↗

The role of viscoelasticity of collagen fibers in articular cartilage: axial tension versus compression.

The role of viscoelasticity of collagen fibers in bovine articular cartilage was examined in compression and tension using stress relaxation measurements in the axial direction (normal to the articular surface). Experimentally, for a given axial strain, both peak and equilibrium loads were higher in tension than in compression, whereas stress relaxation was stronger in compression, as indicated by the higher peak-to-equilibrium ratios. A viscoelastic fibril-reinforced model including fluid flow was used for analysis of the experimental data. The collagen fibrillar matrix was assumed to be viscoelastic with a strain-dependent tensile modulus, and the nonfibrillar matrix was modeled as linearly elastic. For axial tension, collagen viscoelasticity was found to account for most of the stress relaxation, while the effects of fluid pressurization on the tensile stress were negligible. In contrast, for axial compression, the dominant mechanism for stress relaxation arose from fluid pressurization, while the associated relaxation in collagen fibers mainly resulted in an increase in radial strain. The effective Poisson's ratio, defined as the ratio of the radial and axial strains, was generally smaller in compression than in tension, and deviated from the true Poisson's ratio in tensile tests because of the frictional contacts between the specimen and the loading platens. Furthermore, lower collagen elasticity in the axial direction was observed than in the radial direction. This study illustrates the essential role of collagen viscoelasticity and interstitial fluid pressurization in the mechanical response of articular cartilage.

Animals↗

Electromechanical response of articular cartilage in indentation--considerations on the determination of cartilage properties during arthroscopy.

A finite element formulation of streaming potentials in articular cartilage was incorporated into a fibril-reinforced model using the commercial software ABAQUS. This model was subsequently used to simulate interactions between an arthroscopic probe and articular cartilage in a knee joint. Fibril reinforcement was found to account for large fluid pressure at considerable strain rates, as has been observed in un-confined compression. Furthermore, specific electromechanical responses were associated with specific changes in tissue properties that occur with cartilage degeneration. For example, the strong strain-rate dependence of the load response was only observed when the collagen network was intact. Therefore, it is possible to use data measured during arthroscopy to evaluate the degree of cartilage degeneration and the source causing changed properties. However, practical problems, such as the difficulty of controlling the speed of the hand-held probe, may greatly reduce the reliability of such evaluations. The fibril-reinforced electromechanical model revealed that high-speed transient responses were associated with the collagen network, and equilibrium response was primarily determined by proteoglycan matrix. The results presented here may be useful in the application of arthroscopic tools for evaluating cartilage degeneration, for the proper interpretation of data, and for the optimization of data collection during arthroscopy.

Animals↗

Strain-rate dependence of cartilage stiffness in unconfined compression: the role of fibril reinforcement versus tissue volume change in fluid pressurization.

The strain and strain-rate-dependent response of articular cartilage in unconfined compression was studied theoretically. The transient stress and stiffness of cartilage were determined for strain rates ranging from zero to infinity. It is shown, for a given compressive strain, that the axial stress initially increases quickly as a function of strain rate, and then increases progressively more slowly towards the stress corresponding to the instantaneous response. The volume change of the tissue does not give its transient stiffness uniquely, because of the strong strain-rate dependence. The variation of tissue stiffness is primarily determined by the transient stiffness of the radial fibrils. Load sharing between the solid matrix and fluid pressurization also depends on the strain rate. At 15% axial compression, the matrix bears more than 80% of the applied load at a strain rate of 0.005%/s, while the fluid pressurization contributes more than 80% of the load at a strain rate of 0.15%/s. These results show the interplay between fibril reinforcement and fluid pressurization in articular cartilage: the fluid drives fibril stiffening which in turn produces high pore pressure at high strain rates. As a secondary objective of the present work, a fibrillar continuum element was formulated to replace the fibrillar spring element used previously in fibril-reinforced modeling, in order to eliminate the deformation incompatibility between the spring system and the nonfibrillar matrix. The results obtained using the two fibrillar elements were compared with the closed-form solutions for the static and instantaneous responses for the case of large deformation. It was found for unconfined compression that using the spring elements did not generally result in greater numerical errors than using the fibrillar continuum elements.

Animals↗

The role of viscoelasticity of collagen fibers in articular cartilage: theory and numerical formulation.

The relative importance of fluid-dependent and fluid-independent transient mechanical behavior in articular cartilage was examined for tensile and unconfined compression testing using a fibril reinforced model. The collagen matrix of articular cartilage was modeled as viscoelastic using a quasi-linear viscoelastic formulation with strain-dependent elastic modulus, while the proteoglycan matrix was considered as linearly elastic. The collagen viscoelastic properties were obtained by fitting experimental data from a tensile test. These properties were used to investigate unconfined compression testing, and the sensitivity of the properties was also explored. It was predicted that the stress relaxation observed in tensile tests was not caused by fluid pressurization at the macroscopic level. A multi-step tensile stress relaxation test could be approximated using a hereditary integral in which the elastic fibrillar modulus was taken to be a linear function of the fibrillar strain. Applying the same formulation to the radial fibers in unconfined compression, stress relaxation could not be simulated if fluid pressurization were absent. Collagen viscoelasticity was found to slightly weaken fluid pressurization in unconfined compression, and this effect was relatively more significant at moderate strain rates. Therefore, collagen viscoelasticity appears to play an import role in articular cartilage in tensile testing, while fluid pressurization dominates the transient mechanical behavior in compression. Collagen viscoelasticity plays a minor role in the mechanical response of cartilage in unconfined compression if significant fluid flow is present.

Cartilage, Articular↗

Strain-rate dependent stiffness of articular cartilage in unconfined compression.

The stiffness of articular cartilage is a nonlinear function of the strain amplitude and strain rate as well as the loading history, as a consequence of the flow of interstitial water and the stiffening of the collagen fibril network. This paper presents a full investigation of the interplay between the fluid kinetics and fibril stiffening of unconfined cartilage disks by analyzing over 200 cases with diverse material properties. The lower and upper elastic limits of the stress (under a given strain) are uniquely established by the instantaneous and equilibrium stiffness (obtained numerically for finite deformations and analytically for small deformations). These limits could be used to determine safe loading protocols in order that the stress in each solid constituent remains within its own elastic limit. For a given compressive strain applied at a low rate, the loading is close to the lower limit and is mostly borne directly by the solid constituents (with little contribution from the fluid). In contrast, however in case of faster compression, the extra loading is predominantly transported to the fibrillar matrix via rising fluid pressure with little increase of stress in the nonfibrillar matrix. The fibrillar matrix absorbs the loading increment by self-stiffening: the quicker the loading the faster the fibril stiffening until the upper elastic loading limit is reached. This self-protective mechanism prevents cartilage from damage since the fibrils are strong in tension. The present work demonstrates the ability of the fibril reinfored poroelastic models to describe the strain rate dependent behavior of articular cartilage in unconfined compression using a mechanism of fibril stiffening mainly induced by the fluid flow.

Animals↗

An Agrobacterium gene involved in tumorigenesis encodes an outer membrane protein exposed on the bacterial cell surface.

A gene designated as aopB was identified which was involved in tumorigenesis of Agrobacterium tumefaciens. aopB is located on the circular chromosome as a single copy. This gene shares high homology with ropB, a Rhizobium leguminosarum gene encoding an outer membrane protein. A transposon mutant CGI1 containing a gfp-tagged transposon insertion at aopB caused attenuated tumors on plants when inoculated at a low cell concentration (5x10(7) cells/ml). The mutation did not affect the bacterial growth on different media. A broad host range plasmid containing the wild type aopB could restore the tumor formation ability of CGI1 to the wild type level. When both aopB-gfp and aopB-phoA fusions were used to study the aopB gene expression, we found that the aopB gene was inducible by acidic pH but not by plant phenolic compound acetosyringone. aopB encodes a putative protein of 218 amino acids with a predicted molecular weight of 22.8 kDa. TnphoA transposon mutagenesis of aopB, subcellular fractionation and whole cell ELISA experiments indicated that AopB is an outer membrane protein exposed on the bacterial cell surface. It appeared that AopB was exclusively present in the outer membrane and not in other fractions. The vir gene induction assays showed that the aopB gene was not required for the expression of the Ti plasmid encoded vir genes that are essential for tumorigenesis. The C-terminal half of AopB is slightly homologous to some of the bacterial porin proteins and some of plant dehydrins. The role of AopB in Agrobacterium-plant interaction is discussed.

Agrobacterium tumefaciens↗

Alterations in mechanical behaviour of articular cartilage due to changes in depth varying material properties--a nonhomogeneous poroelastic model study.

The depth dependence of the material properties is present in normal adult cartilage and is believed to have significant implications in its normal mechanical function. Cartilage pathology may alter the depth dependence, e.g. a reduced depth dependence of the fibril stiffness has been observed in osteoarthritic cartilage. The objective of the present study is to investigate the alterations in the mechanical response of articular cartilage when the depth dependence of the material properties is varied to simulate healthy and pathological situations. This study is made possible by a recently developed nonhomogeneous poroelastic model. Depth variations of the strains and stresses for individual material phases (collagen, proteoglycan and fluid) are obtained for cartilage disks in unconfined compression using the finite element method. The mean nominal axial strain considered is up to 15%, while the axial strain at the articular surface can reach 33%. This paper demonstrates how the mechanical behaviours of cartilage are affected by individual depth dependent cartilage properties, while such observations are not fully available in experimental investigations. This study suggests the possibility of diagnosing cartilage health by analysing its mechanical behaviours.

Animals↗

Feedback regulation of an Agrobacterium catalase gene katA involved in Agrobacterium-plant interaction.

Catalases are known to detoxify H2O2, a major component of oxidative stress imposed on a cell. An Agrobacterium tumefaciens catalase encoded by a chromosomal gene katA has been implicated as an important virulence factor as it is involved in detoxification of H2O2 released during Agrobacterium-plant interaction. In this paper, we report a feedback regulation pathway that controls the expression of katA in A. tumefaciens cells. We observed that katA could be induced by plant tissue sections and by acidic pH on a minimal medium, which resembles the plant environment that the bacteria encounter during the course of infection. This represents a new regulatory factor for catalase induction in bacteria. More importantly, a feedback regulation was observed when the katA-gfp expression was studied in different genetic backgrounds. We found that introduction of a wild-type katA gene encoding a functional catalase into A. tumefaciens cells could repress the katA-gfp expression over 60-fold. The katA gene could be induced by H2O2 and the encoded catalase could detoxify H2O2. In addition, the katA-gfp expression of one bacterial cell could be repressed by other surrounding catalase-proficient bacterial cells. Furthermore, mutation at katA caused a 10-fold increase of the intracellular H2O2 concentration in the bacteria grown on an acidic pH medium. These results suggest that the endogenous H2O2 generated during A. tumefaciens cell growth could serve as the intracellular and intercellular inducer for the katA gene expression and that the acidic pH could pose an oxidative stress on the bacteria. Surprisingly, one mutated KatA protein, exhibiting no significant catalase activity as a result of the alteration of two important residues at the putative active site, could partially repress the katA-gfp expression. The feedback regulation of the katA gene by both catalase activity and KatA protein could presumably maintain an appropriated level of catalase activity and H2O2 inside A. tumefaciens cells.

Agrobacterium tumefaciens↗

The asymmetry of transient response in compression versus release for cartilage in unconfined compression.

Observations in compression tests of articular cartilage have revealed unequal load increments for compression and release of the same amplitude applied to a disk with an identical previously imposed compression (in equilibrium). The mechanism of this asymmetric transient response is investigated here using a nonlinear fibril-reinforced model. It is found that the asymmetry is predominantly produced by the fibril stiffening with its tensile strain. In addition, allowing the hydraulic permeability to decrease significantly with compressive dilatation of cartilage increases the transient fibril strain, resulting in a stronger asymmetry. Large deformation also enhances the asymmetry as a consequence of stronger fibril stiffening.

Biomechanical Phenomena↗

[Determination of isophthalic acid in polyethylene glycol terephthalate fiber by high performance liquid chromatography].

The isophthalic acid(IPA) is present in polyethylene glycol terephthalate(PET) at small level, but plays an important role for the properties of polyester fiber. Thus the PET sample was hydrolysated by 100 g/L of sodium hydrate in methanol at 70 degrees C during 10 h and finally assayed by HPLC. A reversed-phase high performance liquid chromatographic method for the separation of isophthalic acid from terephthalic acid(TPA) has been developed. The operating conditions were Novapak C18 column, methanol-water(15:85, V/V)(pH3) as mobile phase with the flow rate of 1.0 mL/min and UV detection wavelength at 254 nm.

English Abstract↗

A fibril reinforced nonhomogeneous poroelastic model for articular cartilage: inhomogeneous response in unconfined compression.

The depth dependence of material properties of articular cartilage, known as the zonal differences, is incorporated into a nonlinear fibril-reinforced poroelastic model developed previously in order to explore the significance of material heterogeneity in the mechanical behavior of cartilage. The material variations proposed are based on extensive observations. The collagen fibrils are modeled as a distinct constituent which reinforces the other two constituents representing proteoglycans and water. The Young's modulus and Poisson's ratio of the drained nonfibrillar matrix are so determined that the aggregate compressive modulus for confined geometry fits the experimental data. Three nonlinear factors are considered, i.e. the effect of finite deformation, the dependence of permeability on dilatation and the fibril stiffening with its tensile strain. Solutions are extracted using a finite element procedure to simulate unconfined compression tests. The features of the model are then demonstrated with an emphasis on the results obtainable only with a nonhomogeneous model, showing reasonable agreement with experiments. The model suggests mechanical behaviors significantly different from those revealed by homogeneous models: not only the depth variations of the strains which are expected by qualitative analyses, but also, for instance, the relaxation-time dependence of the axial strain which is normally not expected in a relaxation test. Therefore, such a nonhomogeneous model is necessary for better understanding of the mechanical behavior of cartilage.

Biomechanical Phenomena↗

Nonlinear analysis of cartilage in unconfined ramp compression using a fibril reinforced poroelastic model.

OBJECTIVE: To develop a biomechanical model for cartilage which is capable of capturing experimentally observed nonlinear behaviours of cartilage and to investigate effects of collagen fibril reinforcement in cartilage. DESIGN: A sequence of 10 or 20 steps of ramp compression/relaxation applied to cartilage disks in uniaxial unconfined geometry is simulated for comparison with experimental data. BACKGROUND: Mechanical behaviours of cartilage, such as the compression-offset dependent stiffening of the transient response and the strong relaxation component, have been previously difficult to describe using the biphasic model in unconfined compression. METHODS: Cartilage is modelled as a fluid-saturated solid reinforced by an elastic fibrillar network. The latter, mainly representing collagen fibrils, is considered as a distinct constituent embedded in a biphasic component made up mainly of proteoglycan macromolecules and a fluid carrying mobile ions. The Young's modulus of the fibrillar network is taken to vary linearly with its tensile strain but to be zero for compression. Numerical computations are carried out using a finite element procedure, for which the fibrillar network is discretized into a system of spring elements. RESULTS: The nonlinear fibril reinforced poroelastic model is capable of describing the strong relaxation behaviour and compression-offset dependent stiffening of cartilage in unconfined compression. Computational results are also presented to demonstrate unique features of the model, e.g. the matrix stress in the radial direction is changed from tensile to compressive due to presence of distinct fibrils in the model. RELEVANCE: Experimentally observed nonlinear behaviours of cartilage are successfully simulated, and the roles of collagen fibrils are distinguished by using the proposed model. Thus this study may lead to a better understanding of physiological responses of individual constituents of cartilage to external loads, and of the roles of mechanical loading in cartilage remodelling and pathology.

Biomechanical Phenomena↗

Biosafety monitoring of patients receiving intracerebral injections of murine retroviral vector producer cells.

Patients with recurrent malignant brain cancer, who were receiving gene therapy by intracerebral injection of murine retroviral vector producer cells (VPCs), were monitored for the presence of replication-competent retrovirus (RCR). RCR sequences were not detected by polymerase chain reaction (PCR) in any of the 608 peripheral blood leukocyte (PBL) samples analyzed. Vector DNA sequences were detected transiently in PBL samples from a subset of 34 patients. Humoral immune responses to a retroviral core protein p30 and murine VPC were detected in some patients, most frequently in patients receiving repeated administrations of VPC. RCR was not detected in biological assays of PBLs from 41 patients who had either anti-retroviral antibodies in sera and/or vector DNA in PBLs. Our data suggest that in situ generation of RCR was not detected following intracerebral inoculation of VPCs in any of the 128 patients evaluated.

Animals↗

[Ultrasonic diagnosis in the surgical treatment of angiodysplasias of the lower extremities].

An experience with examination and surgical treatment of 156 patients with angiodysplasia of lower extremities shows that the ultrasonic location and dopplerography are highly informative methods of diagnosis of this disease. The orthostatic probe (the Valsalva test effect) allows the spread of angiodysplasia (suprafascial or subfascial) to be determined. The adequate strategy and volume of surgery can be chosen correctly. These methods of examination being noninvasive and easy makes them helpful for the objective assessment of the effectiveness of the surgical procedures and control of further treatment.

Adolescent↗