PubMed Health⌕ Search

Biomedical subjects

L Patrizii

Publications and source records attributed to L Patrizii.

6 recordsLinked to original sources

CR-39 acceptance test and optimisation for fast neutron dosimetry applications.

The ENEA fast neutron dosemeter is based on a planar PADC (poly allyl diglycol carbonate) placed in a polyethylene holder. The CR-39 (registered trademark of PPG Industries Inc.) material, produced by Intercast Europe S.p.A., has been used in the routine of the Individual Monitoring Service (IMS) since 1998. Since then, acceptance tests on average sheet background track density and sheet neutron sensitivity have been made on new batches as a quality control within a quality assurance programme of the IMS of ENEA-Institute for Radiation Protection (IRP). Dosemeters were irradiated with a 241Am-Be source at ENEA-IRP and processed through a chemical etching procedure (pre-etching with 40% KOH water solution 6.25 N and 60% ethyl alcohol at 70 degrees C followed by 12 h of etching in 6.25 N KOH water solution). In this paper we present the analysis of acceptance testing data for more than 30 sheets of CR-39 plastic produced in 1998, 1999 and 2000. Moreover, we compare the performance of sheets of CR-39 of standard composition with that of sheets of CR-39 with the addition of DOP (dioctylphthalate), in different concentrations, on the hasis of average background density, neutron sensitivity and background fluctuation that limit the lower detectable dose. This study demonstrates the need for acceptance tests to assure the quality of the dosimetric performance of these dosemeters, which is considerably dependent on the quality of the CR-39 plastic.

Calibration↗

A passive radon dosemeter suitable for workplaces.

The results obtained in different international intercomparisons on passive radon monitors have been analysed with the aim of identifying a suitable radon monitoring device for workplaces. From this analysis, the passive radon device, first developed for personal dosimetry in mines by the National Radiation Protection Board, UK (NRPB), has shown the most suitable set of characteristics. This radon monitor consists of a diffusion chamber, made of conductive plastic with less than 2 cm height, containing a CR-39 film (Columbia Resin 1939), as track detector. Radon detectors in workplaces may be exposed only during the working hours, thus requiring the storage of the detectors in low-radon zones when not exposed. This paper describes how this problem can be solved. Since track detectors are also efficient neutron dosemeters, care should be taken when radon monitors are used in workplaces, where they may he exposed to neutrons, such as on high altitude mountains, in the surroundings of high energy X ray facilities (where neutrons are produced by (gamma, n) reactions) or around high energy particle accelerators. To this end, the response of these passive radon monitors to high energy neutron fields has been investigated.

Air Pollution, Indoor↗

Radon measurements in the Gran Sasso Underground Laboratory.

Systematic radon monitoring in the Gran Sasso Underground Laboratory was performed in order to determine the background radon contribution to the sophisticated experimental apparatus and to check health physics standards for the personnel. As expected, the radon concentrations were found to depend strongly on the ventilation in the three experimental halls. Considerable reductions in the radon concentrations were obtained in 1993, when fresh air was drawn into the laboratory through a pipe and exhaust air was routed into the highway tunnel.

Air Pollutants, Radioactive↗