PubMed Health⌕ Search

Biomedical subjects

L Perlick

Publications and source records attributed to L Perlick.

At least 19 recordsLinked to original sources

The computer-assisted sequential lateral soft-tissue release in total knee arthroplasty for valgus knees.

Soft-tissue management is a critical factor in total knee arthroplasty, especially in valgus knees. The stepwise release has been based upon surgeon's experience. Computer-assisted surgery has gained increasing scientific interest in recent times and allows the intraoperative measurement of leg axis and gap size in extension and flexion. We therefore aimed to analyse the effect of sequential lateral soft-tissue release and the resulting change in the a.p. limb axis on the one hand and the tibiofemoral gaps on the other hand in extension as well as in flexion in eight cadaveric knees. Measurements were obtained using a CT-free navigation system. In extension the highest increase compared to the previous release step was found for the first (iliotibial band, P = 0.002), second (popliteus muscle, P = 0.0003), third (LCL, 0.007) and the sixth (entire PCL, P = 0.001) release step. In 90 degrees flexion all differences of the lateral release steps were statistically significant (P < 0.004). Massive progression of the lateral gap in flexion was found after the second (popliteus muscle, P = 0.004) and third (LCL, 0.007) release step. Computer-assisted surgery allows measurement of the effect of each release step of the sequential lateral release sequence and helps the surgeon to better assess the result.

Arthroplasty, Replacement, Knee↗

Precision of computer-assisted core decompression drilling of the knee.

INTRODUCTION: Core decompression by exact drilling into the ischemic areas is the treatment of choice in early stages of osteonecrosis of the femoral condyle. Computer-aided surgery might enhance the precision of the drilling and lower the radiation exposure time of both staff and patients. The aim of this study was to evaluate the precision of the fluoroscopically based VectorVision-navigation system in an in vitro model. MATERIALS AND METHODS: Thirty sawbones were prepared with a defect filled up with a radiopaque gypsum sphere mimicking the osteonecrosis. 20 sawbones were drilled by guidance of an intraoperative navigation system VectorVision (BrainLAB, Munich, Germany). Ten sawbones were drilled by fluoroscopic control only. RESULTS: A statistically significant difference with a mean distance of 0.58 mm in the navigated group and 0.98 mm in the control group regarding the distance to the desired mid-point of the lesion could be stated. Significant difference was further found in the number of drilling corrections as well as radiation time needed. CONCLUSION: The fluoroscopic-based VectorVision-navigation system shows a high feasibility and precision of computer-guided drilling with simultaneously reduction of radiation time and therefore could be integrated into clinical routine.

Decompression, Surgical↗

[Advances in soft tissue management in total knee arthroplasty. The use of imageless navigation systems].

Computer aided surgery has become established in the clinical routine over the past years. There are some very good studies which show that navigation optimizes reconstruction of the leg axis in total knee replacement. The question of why outliers occur in spite of navigation has to be asked. It is clear that total knee replacement is not only a bony procedure, but the soft tissues have an immense influence on postoperative stability of the prosthesis over the full range of movement. Current navigation systems allow visualization of the leg axis and size of the extension and flexion gap, and support the surgeon during soft tissue management. The current paper shows how the anatomic approach and the position of the patella influence soft tissue tension and support the surgeon during release of soft tissues in severe leg axis deformities.

Arthroplasty, Replacement, Knee↗

[Revision prosthetic of the knee joint. The influence of a navigation system on the alignment and reconstruction of the joint line].

Recognizing the rising number of primary total knee arthroplasties (TKA) over the last decade, one may assume an increasing number for revisions after a certain time delay. Studies showing a rate of only 78% satisfied patients provide a hint that there is still room for improvement. Therefore, it seemed worthwhile to evaluate the benefits of the computer assisted technique in revision TKA and compare the alignment results with the conventional technique. In a prospective study, 120 patients were operated for revision TKA using either the Vector-Vision navigation system (n=60) or the conventional technique (n=60). The axial limb alignment was evaluated on standardized pre- and postoperative full length weight-bearing radiographs and the variation of the joint line was determined by the method of Figgie from 1986.A precise reconstruction of the mechanical limb axis was achieved in 57/60 Patients (95%) in the computer assisted group and in 48/60 (80%) in the conventional group. A reconstruction of the joint line with a variation of less then 4 mm was achieved in 47/60 (78%) in the computer assisted and in 33/60 (55%) in the conventional group. Revision TKA remains a challenging procedure for the surgeon. Modern navigation systems offer additional information intraoperatively and might therefore simplify the procedure. In particular, the adjustment of the extension and flexion gap and the reconstruction of the joint line the results were superior. Furthermore, the use of a CT-free navigation system provides a significant improvement of prosthesis and leg alignment in revision TKA.

Aged↗

Precision of computer-assisted core decompression drilling of the femoral head.

INTRODUCTION: Osteonecrosis of the femoral head is a local destructive disease with progression into devastating stages. Left untreated it mostly leads to severe secondary osteoarthrosis and early endoprosthetic joint replacement. Core decompression by exact drilling into the ischemic areas can be performed in early stages according to Ficat or ARCO. Computer-aided surgery might enhance the precision of the drilling and lower the radiation exposure time of both staff and patients. The aim of this study was to evaluate the precision of the fluoroscopically based VectorVision navigation system in an in vitro model. MATERIALS AND METHODS: Thirty sawbones were prepared with a defect filled up with a radiopaque gypsum sphere mimicking the osteonecrosis. Twenty sawbones were drilled by guidance of an intraoperative navigation system VectorVision (BrainLAB, Munich, Germany) and 10 sawbones by fluoroscopic control only. RESULTS: No gypsum sphere was missed. There was a statistically significant difference regarding the three-dimensional deviation (Euclidian norm) as well as maximum deviation in x-, y- or z-direction (maximum norm) to the desired mid-point of the lesion, with a mean of 0.51 and 0.4 mm in the navigated group and 1.1 and 0.88 mm in the control group, respectively. Furthermore, significant difference was found in the number of drilling corrections as well as the radiation time needed: no second drilling or correction of drilling direction was necessary in the navigated group compared to 1.4 in the control group. The radiation time needed was less than 1 s compared to 3.1 s, respectively. CONCLUSION: The fluoroscopy-based VectorVision navigation system shows a high feasibility of computer-guided drilling with a clear reduction of radiation exposure time and can therefore be integrated into clinical routine. The additional time needed is acceptable regarding the simultaneous reduction of radiation time.

Decompression, Surgical↗

[Pullout resistance of conventional pedicle screw implantation in comparison to fluoroscopic computer-assisted technique].

AIM: Aim of the study was to compare pullout resistance of pedicle screws after conventional and fluoroscopic computer-assisted implantation in the cadaveric thoracic and lumbar spine. METHODS: Pedicle screws were inserted in a total of 10 vertebrae of different human specimens: 10 screws were placed using conventional technique (group 1) and 10 screws were inserted with fluoroscopic computer-assisted system contralaterally (group 2). Then pedicle screws were evaluated for biomechanical axial pullout resistance. RESULTS: Mean pullout force was 232 N (range 60-600 N) in group 1 and 353 N (range 112-625 N) in group 2. The difference was significant (p=0,0425). CONCLUSION: Fluoroscopic navigated implantation of pedicle screws increases the pullout strength in thoracic and lumbar cadaveric spines as compared with conventional methods.

Aged↗

Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation?

In a prospective randomised clinical study acetabular components were implanted either freehand (n = 30) or using CT-based (n = 30) or imageless navigation (n = 30). The position of the component was determined post-operatively on CT scans of the pelvis. Following conventional freehand placement of the acetabular component, only 14 of the 30 were within the safe zone as defined by Lewinnek et al (40 degrees inclination sd 10 degrees ; 15 degrees anteversion sd 10 degrees ). After computer-assisted navigation 25 of 30 acetabular components (CT-based) and 28 of 30 components (imageless) were positioned within this limit (overall p < 0.001). No significant differences were observed between CT-based and imageless navigation (p = 0.23); both showed a significant reduction in variation of the position of the acetabular component compared with conventional freehand arthroplasty (p < 0.001). The duration of the operation was increased by eight minutes with imageless and by 17 minutes with CT-based navigation. Imageless navigation proved as reliable as that using CT in positioning the acetabular component.

Acetabulum↗

Computer assistance in total knee replacement - a critical assessment of current health care technology.

The last five years have seen the rapid development of computer assisted surgery (CAS) in total knee replacement (TKR). Many surgeons perform TKR using navigation systems, which offer user-friendly workflows and reproducible results. A number of level 1 and 2 studies, according to evidence-based medicine criteria, have demonstrated that navigation in TKR allows a more precise implantation of the prosthesis, though CAS still requires an experienced surgeon and is time consuming. Nevertheless, 30% of surgeons in Germany who perform TKR have used navigation. It is still not known whether this new technique improves the longevity of TKR, however, and we therefore performed a meta-analysis to assess the results of this new health care technology.

Arthroplasty, Replacement, Knee↗

Two-year follow-up on joint stability and muscular function comparing rotating versus fixed bearing TKR.

Mobile and fixed bearing in total knee replacement are still discussed controversially. In a retrospective, matched-pair study, we investigated 40 patients with computer-assisted (BrainLAB) primary total knee replacement (PFC Sigma, DePuy) performed two years before. Twenty patients each received a mobile bearing and a fixed bearing. We compared Womac Score, Knee Society Score, postoperative ROM, fluoroscopic measurement of knee stability in flexion and extension and isokinetic muscle strength using a Biodex-3 dynamometer. Both groups showed similar results concerning WOMAC Score (total rotating bearing: 23.05; fixed bearing: 22.57), KSS (rotating bearing: 174.89; fixed bearing: 176.1). Isokinetic muscle force demonstrated statistically significant superior results for knee flexion in the rotating bearing group. Medio-lateral stability revealed statistically significant superior results for the rotating bearing compared to fixed bearing in extension (P>0.05). In flexion only lateral stability was superior (P>0.05). Two-year clinical follow-up after computer-assisted total knee replacement resulted in good clinical outcome with high patient satisfaction. Statistically significant better values for the rotating platform group were found for the medio-lateral stability in extension and the peak flexion torque.

Aged↗

Micromotion in cemented rotating platform total knee arthroplasty: cemented tibial stem versus hybrid fixation.

INTRODUCTION: Improving the longevity and reliability of cemented total knee arthroplasty (TKA) remains a major step to achieve. It is still unclear, whether a cemented tibial stem reduces micromotion of the tibial tray and produces therefore a better initial stability or not. The higher conformity of rotating platform design and the possible rotary forces to the tibial platform may produce higher micromotion when the tibial stem remains cementless (hybrid fixation). MATERIALS AND METHODS: An in vitro study was performed using the PFC mobile bearing tibial tray (DePuy, Warswa, IN, USA) to test the hypothesis that the addition of cement surrounding the tibial stem reduces micromotion of the tibial tray in cemented TKA with mobile bearing design. Ten tibial trays with mobile design were implanted in sawbones with a 3-mm cement mantle beneath the baseplate of the tibial tray and with or without the cemented stem. Tibial trays were loaded additionally in the ventral, lateral, medial and posterior positions with 2,500 N using the Zwick Z010 instrumentation and HBM pick up Hottinger Baldwin. RESULTS: In this study, a significant increased mean maximum liftoff was found when only cementing the tibial baseplate (hybrid fixation), compared to the fully cemented tibial tray (P<0.02). CONCLUSION: In conclusion, the stem of mobile bearing tibial components should be cemented to provide increased micromotion and earlier loosening.

Arthroplasty, Replacement, Knee↗

Greater accuracy in positioning of the acetabular cup by using an image-free navigation system.

In a prospective and randomised clinical study, acetabular cups were implanted free-hand (control group n=22) or with computer assistance using an image-free navigation system (study group n=23). The cup position was determined postoperatively on pelvic CT. An average inclination of 42.3 degrees (range: 30 degrees -53 degrees ; SD+/-7.0 degrees ) and an average anteversion of 24.0 degrees (range: -3 degrees to 51 degrees ; SD+/-15.0 degrees ) were found in the control group, and an average inclination of 45.0 degrees (range: 40 degrees -50 degrees ; SD+/-2.8 degrees ) and an average anteversion of 14.4 degrees (range: 5 degrees -25 degrees ; SS+/-5.0 degrees ) in the computer-assisted study group. The deviations from the desired cup position (45 degrees inclination, 15 degrees anteversion) were significantly lower in the computer-assisted study group (p<0.001 each). While only 11/22 of the cups in the control group were within the Lewinnek safe zone, 21/23 of the cups in the study group were placed in this target region (p=0.003).

Acetabulum↗

Eversion or subluxation of patella in soft tissue balancing of total knee arthroplasty? Results of a cadaver experiment.

Correct postoperative leg alignment and stability of total knee prosthesis over the full range of movement are critical factors for successful TKA. This is achieved by correct implantation of prosthesis and soft tissue handling. However, the surgical approach and how to displace the patella are still controversial. We have carried out a cadaver study looking at the effect of patella eversion or subluxation on limb axis alignment during balancing of the knee in three different standard surgical approaches; subvastus, midvastus, or medial parapatellar. For each approach, five knees were studied. Leg alignment was visualised by the Ci CT-free DePuy/BrainLAB navigation system. Using a navigation system alignment was determined in the AP axis in both extension and 90 flexion, with the patella everted as well as subluxated. Eversion of the patella gave a more valgus axis reading than subluxation in both extension 0.58 (SD: 0.03, range 0.54 -0.60 ) and 90 flexion 0.48 (SD: 0.11, range 0.38 -0.60 ). The effect was greatest using the medial paraptellar approach. Surgeons should be aware that everting the patella influences the AP alignment when soft tissue balancing in total knee replacement.

Arthroplasty, Replacement, Knee↗

[What is the influence of the approach to intraoperative measurement of the knee joint on total knee arthroplasty? A navigation-controlled study on a cadaver knee].

Correct postoperative leg alignment and stability of the total knee prosthesis over the full range of movement is one critical factor for successful TKA. The anatomic approach is still the subject of controversy. The aim of our study was to elucidate the influence of the surgical approach on the ligament balancing and the anterioposterior limb axis.On five cadaver knees we studied the influence of the subvastus, midvastus, medial parapatellar, rectus snip, and tuberosity osteotomy approaches on the anterioposterior leg axis in extension and the rotation of the femoral component in flexion. Measurements were performed and documented by CT-free Ci-Navigation-System. Ligament tension was measured with a tensor device. We found that the subvastus approach leads to less widening of the medial compartment than all other approaches in extension. In 90 degrees flexion we found a similar influence. The consecutive release from subvastus to midvastus to medial parapatellar approach leads to a further opening of 0.5-1 degrees valgus in extension as well as in flexion. An everted patella amplifies this influence. The surgeon has to be aware of the impact on the ligament situation in regard to the anatomic approach when ligament balancing and soft tissue releases are carried out. Patella eversion should be avoided when managing soft tissues.

Arthroplasty, Replacement, Knee↗

[Soft tissue management in knees with varus deformity. Computer-assisted sequential medial ligament release].

BACKGROUND: Knees with severe varus deformities and contractures of the medial and lateral collateral ligaments and the posterior capsule require special soft tissue management to gain a stable knee over the full range of movement. The introduction of navigation systems into knee surgery has now made precise measurement of the leg axis and gap size possible. METHODS: Ten knee joints received a computer-assisted total knee replacement (Ci navigation system DePuy) I-Orthopaedics, Munich). The change of the leg axis and the size of the mediolateral gaps were measured and documented when performing a standardized medial ligament release sequence. RESULTS: We found a significant effect after each release step regarding the change of the leg axis as well as the gap width (p<0.001). The highest effect was seen for the 6-cm capsule release in extension and the release of the medial collateral ligament in 90 degrees flexion. CONCLUSION: Implementation of computer-assisted navigation facilitates visualization and quantification of the effect of the sequential medial soft tissue release in total knee arthroplasty.

Arthroplasty, Replacement, Knee↗

Intraoperative cutting errors in total knee arthroplasty.

INTRODUCTION: Precise reconstruction of leg alignment offers the best opportunity for achieving good long-term results in total knee arthroplasty (TKA). It was the aim of this study to evaluate the bone-cutting process as a potential source of inaccuracy in TKA. MATERIALS AND METHODS: In a consecutive series of 50 computer-assisted TKAs, cutting errors, which were defined as a difference between the cutting block position before sawing and the achieved resection plane afterwards, were measured for the distal femur and proximal tibia resection. Measurements were performed using a CT-based navigation system. RESULTS: For the distal femoral cut, there was a mean varus/valgus deviation of 0.6 degrees (SD+/-0.5 degrees ) and a mean flexion/extension deviation of 1.4 degrees (SD+/-1.3 degrees ). For the proximal tibia, varus/valgus alignment showed a mean deviation of 0.5 degrees (SD+/-0.5 degrees ). The mean sagittal variability was 1.0 degrees (SD+/-0.9 degrees ). Differences between the frontal and the sagittal plane were significant. CONCLUSION: To minimize cutting errors, techniques and instruments are needed which enable a more stable fixation of the cutting blocks or even more appropriate preparation instruments. Using a computer-assisted technique, the surgeon is aware of cutting errors occurring at each point of the operation and will therefore be able to correct these errors during surgery, while he is not aware of those errors with the conventional TKA technique.

Adult↗

Flexion gap configuration in total knee arthroplasty following high tibial osteotomy.

Previous reports have described the potentially compromising effect of a high tibial osteotomy (HTO) on the results of a subsequent total knee arthroplasty (TKA). Although the reasons are not clear, some authors reported problems in soft-tissue balancing. In a prospective study, 22 patients with an average interval of 5.8 years after closed-wedge HTO were operated for TKA. All operations were performed with a CT-free navigation system, and measurements of the extension and flexion gap were assessed. The intraoperative data were compared to a control group of 100 consecutive computer-assisted TKA without previous osteotomy. In the study group, a highly significant shift towards a medial opening of the flexion gap between the posterior condylar line and the tibial resection (study group 0.4+/-4.7 degrees medial opening versus control group 3.4+/-3.3 degrees lateral opening, p<0.001) was observed. In the study group, 10/22 showed a medial opening of the flexion gap compared to 11/100 in the control group. Surgeons should be aware of difficulties in soft-tissue balance in TKA following HTO, especially for the flexion gap configuration and the axial rotation of the femoral component.

Aged↗

Minimally invasive unicompartmental knee replacement with a nonimage-based navigation system.

In a prospective study, two groups of 20 unicompartmental knee replacements (UKR) each were operated either using a CT-free navigation system or the conventional minimal invasive technique. Radiographic assessment of postoperative alignment was performed by long-leg coronal and lateral radiographs. The results revealed a significant difference between the two groups in favor of navigation. In the computer-assisted group, 95% of UKRs were in a range of 4-0 degrees varus (mechanical axis) compared with 70% in the conventional group. The only inconvenience was a prolonged operation time (+19 min). Due to the limited exposure, the navigation system is helpful in achieving a more precise component orientation. The danger of overcorrection is diminished by real-time information about the leg axis at each step during the operation.

Aged↗