PubMed Health⌕ Search

Biomedical subjects

L Pilgrim

Publications and source records attributed to L Pilgrim.

6 recordsLinked to original sources

Selecting among competing alternatives: selection and retrieval in the left inferior frontal gyrus.

It has been widely argued that the left inferior frontal gyrus (LIFG) is involved in the control of retrieval of information from long-term memory. Recent claims that the LIFG is involved in selecting among semantic alternatives have been challenged on the grounds that the manipulation of selection demands may have been confounded with controlled retrieval. The current study used an event-related functional magnetic resonance paradigm to re-examine the possibility that LIFG activation is involved in selection processes. In order to minimize potential confounding effects of controlled retrieval, we used an automatic retrieval task (picture naming) and held retrieval demands constant, while varying selection demands by way of competitor priming from earlier semantically related trials. We found significant activation in LIFG as a function of increased selection demands; activation centred on two peaks, one in anterior LIFG and a second more superior and posterior region. These data support the view that LIFG plays a role in selection among semantic information, even in the absence of controlled retrieval processes.

Adult↗

Utterance rate and linguistic properties as determinants of lexical dysfluencies in children who stutter.

Two important determinants of variation in stuttering frequency are utterance rate and the linguistic properties of the words being spoken. Little is known how these determinants interrelate. It is hypothesized that those linguistic factors that lead to change in word duration, alter utterance rate locally within an utterance that then gives rise to an increase in stuttering frequency. According to the hypothesis, utterance rate variation should occur locally within the linguistic segments in an utterance that is known to increase the likelihood of stuttering. The hypothesis is tested using length of tone unit as the linguistic factor. Three predictions are confirmed: Utterance rate varies locally within the tone units and this local variation affects stuttering frequency; stuttering frequency is positively related to the length of tone units; variations in utterance rate are correlated with tone unit length. Alternative theoretical formulations of these findings are considered.

Child↗

Phonological words and stuttering on function words.

Stuttering on function words was examined in 51 people who stutter. The people who stutter were subdivided into young (2 to 6 years), middle (6 to 9 years), and older (9 to 12 years) child groups; teenagers (13 to 18 years); and adults (20 to 40 years). As reported by previous researchers, children up to about age 9 stuttered more on function words (pronouns, articles, prepositions, conjunctions, auxiliary verbs), whereas older people tended to stutter more on content words (nouns, main verbs, adverbs, adjectives). Function words in early positions in utterances, again as reported elsewhere, were more likely to be stuttered than function words at later positions in an utterance. This was most apparent for the younger groups of speakers. For the remaining analyses, utterances were segmented into phonological words on the basis of Selkirk's work (1984). Stuttering rate was higher when function words occurred in early phonological word positions than other phonological word positions whether the phonological word appeared in initial position in an utterance or not. Stuttering rate was highly dependent on whether the function word occurred before or after the single content word allowed in Selkirk's (1984) phonological words. This applied, once again, whether the phonological word was utterance-initial or not. It is argued that stuttering of function words before their content word in phonological words in young speakers is used as a delaying tactic when the forthcoming content word is not prepared for articulation.

Child↗

Urinary antimony in infancy.

OBJECTIVE: To determine whether antimony may be detected in the urine during infancy and early childhood and its association with passive exposure to tobacco smoke, as assessed by urinary cotinine. DESIGN: Analysis of spare aliquots of urine collected from infants participating in studies of respiratory function and passive smoking. Urinary antimony was assayed using inductively coupled plasma mass spectroscopy in 201 urine specimens collected at different ages throughout the first two years of life from 122 term and 26 preterm infants. Urinary cotinine was measured using gas liquid chromatography. MAIN OUTCOME MEASURE: Urinary antimony concentrations. RESULTS: Absolute antimony concentrations varied widely between infants, being below the laboratory detection limit of 0.02 microgram/l in 7% of samples, below 0.5 microgram/l in 90.5%, and above the reference value of 1 microgram/l reported for non-occupationally exposed UK populations in 4%. Creatinine standardised antimony values were unrelated to postnatal age or urinary cotinine concentrations and were highest in urine collected from preterm infants within 24 hours of birth (geometric mean (95% confidence interval): 2.3 ng/mg (1.5 to 3.4)). CONCLUSIONS: Although antimony is present at very low concentrations in urine during infancy and early childhood, the relevance to health is uncertain. The higher levels found in preterm infants may reflect prematurity or fetal assimilation of antimony. Tobacco is unlikely to be an important source of environmental exposure to antimony during infancy and early childhood.

Aging↗

A new microtransducer catheter for measuring esophageal pressure in infants.

Measurement of esophageal pressure, as a reflection of pleural pressure, is essential for assessment of dynamic lung mechanics in neonates and infants. Conventionally, an esophageal balloon or a fluid-filled catheter is used, but considerable skill is required to obtain accurate results. Both devices have problems, and failure to achieve valid occlusion tests have been reported, particularly in small infants with lung disease. Recently, a flexible #3 French gauge (FG) microtransducer catheter (MTC, Dräger Netherlands) has become available for medical monitoring. We have assessed the accuracy and feasibility of using this device for measuring lung mechanics in 51 spontaneously breathing infants and small children aged 1 day to 24 months (weight 1.35 to 12.0 kg), 9 of whom were healthy neonates, the remainder suffering from a variety of cardio-respiratory diseases, and in 18 sick ventilated infants (weight 0.6 to 4.0 kg). Positioning of the catheter was well tolerated by all infants. The ratio of esophageal to airway opening pressure changes (delta Pes:delta Pao) ranged from 0.94 to 1.09 [mean (SD) 1.013 (0.03)] for the spontaneously breathing infants and from 0.98 to 1.06 [mean (SD) 1.003 (0.02)] In the ventilated infants with no significant difference in this ratio between the two groups (p = 0.16). This new generation of catheter tip pressure transducers may provide a simpler and more reliable tool for assessing transpulmonary pressure changes in infants than has previously been available.

Catheterization↗

A critical assessment of uncalibrated respiratory inductance plethysmography (Respitrace) for the measurement of tidal breathing parameters in newborns and infants.

We have compared results obtained with an uncalibrated respiratory inductance plethysmograph (RIP) with those of a face mask and pneumotachograph (PNT) for the computerized measurement of the time to reach peak tidal expiratory flow as a ratio of total expiratory time (tPTEF:tE). Simultaneous measurements were made in 32 healthy neonates aged 0-3 weeks, 35 healthy infants aged 5-82 weeks, and 28 infants aged 15-94 weeks with physician diagnosed recurrent wheeze. The group mean (+/- SD) values of tPTEF:TE determined using a PNT were 0.455 (+/- 0.129), 0.263 (+/- 0.077), and 0.232 (+/- 0.089) for the neonates, healthy infants and infants with recurrent wheeze respectively. RIP gave mean (+/- SD) values that were 0.055 (+/- 0.044) and 0.025 (+/- 0.104) lower than the PNT in healthy neonates and infants with recurrent wheeze respectively; RIP values were 0.002 (+/- 0.073) higher in the healthy infants over 4 weeks of age than measurements by PNT. Although the difference between the two measurements was not related to the thoracoabdominal phase angle, as measured from Lissajous figures, examination of the RIP ribcage and abdominal signals revealed that many healthy subjects, while appearing clinically in phase, had ribcage and abdominal signals that differed markedly from each other in terms of convexity/concavity during early expiration. This may explain the lack of agreement between the two methods. We conclude that uncalibrated RIP should be used with caution for the determination of tPTEF:tE, even in subjects whose ribcage and abdomen appear to move synchronously. The measurement of tPTEF:tE did not differentiate between the healthy infants and infants with recurrent wheezing.

Data Interpretation, Statistical↗