The value of plasma calibrants in correcting coagulometer effects on international normalized ratios. An international multicenter study.

A study of lyophilized plasma calibrants in correcting for coagulometer effects on International Normalized Ratios (INR) has been conducted in an international survey. Prothrombin times were performed with the calibrants on 2 "common" thromboplastins and in-house thromboplastins in 3 brands of coagulometer at 37 centers. The International Sensitivity Indices (ISI) of 95 local systems with the calibrants were derived. The "true" INR of 10 test plasmas from warfarin-treated patients were established centrally using thromboplastin International Reference Preparations (IRP). International Normalized Ratios of these plasmas for each center were calculated using both the manufacturers' stated and the local ISI. The mean deviation of the 95 systems from the "true" INR of the warfarin plasmas was +14.4% with the manufacturers' ISI, but reduced to +1.04% with the local ISI. Local ISI determination with the calibrants avoids many of the difficulties of conventional thromboplastin calibrations. Plasmas from patients on warfarin and parallel manual PT with thromboplastin IRP are not required.

Blood Coagulation Tests↗

A comparison of lyophilized artificially depleted plasmas and lyophilized plasmas from patients receiving warfarin in correcting for coagulometer effects on international normalized ratios.

The comparative value of lyophilized artificially depleted plasmas and plasmas from warfarin-treated patients in local (thromboplastin/coagulometer) system International Sensitivity Indices (ISI) determination has been studied at 39 centers in an international collaborative study. At each center, both types of plasmas were tested with two common thromboplastins (low ISI RecombiPlasTin and high ISI OBT), and in-house reagents using three brands of coagulometers. In 95 local systems, they was agreement. With both thromboplastins, coagulometers lowered the ISI from the manual or stated ISI with all systems. Differences between the two types of lyophilized plasmas with the two common thromboplastins were not of clinical importance. Artificially depleted plasmas are easier to obtain in sufficient volumes than plasma from warfarin-treated patients, and more easily provide the wide range of INR values required for reliable local ISI calibration. The agreement between the two types of lyophilized calibrant is reassuring.

Blood Coagulation Tests↗

The APTT monitoring of heparin--the ISTH/ICSH collaborative study.

In an international collaborative study three candidate reference and the local APTT reagent have been tested with lyophilized plasmas containing heparin added in vitro and fresh plasmas from heparinized patients to determine whether it was possible to standardize APTT heparin monitoring. The APTT responses of patients with thrombosis were much less to the same concentrations of heparin so only these plasmas were used to calibrate the reagents. A calibration constant (b) was determined for each local APTT system from the orthogonal regression slope of the patients' and normals' plasmas. Although the calibration was based on relatively limited numbers of patients' plasmas the results gave no consistent indication that this method of analysis with the reference preparations was incorrect. Two of the three candidate reference reagents performed almost equally well and one of these reagents is recommended as the APTT reference preparation. Use of a single b value for a brand of reagent for all laboratories is not advised. Each laboratory must perform its own local calibration. The adoption of a reference APTT reagent together with the use of orthogonal regression analysis would be a useful step to initiate APTT heparin monitoring standardization and to develop safe and effective local therapeutic ranges.

Automation↗

The international normalized ratio. A guide to understanding and correcting its problems.

With the increasing use of the international normalized ratio (INR) to monitor warfarin therapy, a number of problems with prothrombin time (PT) testing have been identified that have led some laboratory physicians to question the reliability of the INR. This is ironic, because it was the introduction of the INR system that brought to light some of the long-standing problems with the technique of PT monitoring. However, these problems are not insurmountable if a compromise can be reached between the expectations of laboratory physicians and of clinicians. Thus, the laboratory physician seeks a perfect assay system, which in the case of the INR is unattainable at present, because of differences in PT reagents and methods. In contrast, the clinician is satisfied with a system of monitoring that provides safe and effective warfarin dosing. This goal can be achieved provided that certain details of PT testing are observed. In this communication, which is directed to practicing clinicians, the potential problems with the INR system are discussed, their clinical relevance is critically reviewed, and solutions are offered.

Anticoagulants↗

The correction of coagulometer effects on international normalized ratios: a multicentre evaluation.

One hundred and twenty-nine centres in the U.K. participated in a study to test the reliability of the three methods of correction for coagulometer effects on international normalized ratios (INR). Results from 37 centres which tested three warfarinized plasmas by the manual method were taken as the 'true' INR for the assessment of coagulometers. 63 centres (11 manual and 52 using coagulometers) determined their local International Sensitivity Index (ISI) in a calibration exercise. This was performed with a set of 20 lyophilized plasma calibrants with certified manual prothrombin times for the thromboplastin used in the study. The following methods of INR derivation were compared by assessing the percentage deviation from the three INR values established by 37 manual users: I. No coagulometer correction, i.e. (local PT/reference manual normal PT)manual ISI II. Coagulometer ratio correction, i.e. (local coagulometer PT/local coagulometer MNPT)manual ISI III. Local system ISI, i.e. (local coagulometer PT/local coagulometer MNPT)local system ISI IV. System ISI, i.e. (local coagulometer PT/local coagulometer MNPT)system ISI The local system ISI with the plasma calibrants (method III) gave the most reliable correction (mean deviation from 'true' INR 4.87%). The method which gave the least was with the coagulometer ratio correction, i.e. the manual ISI and local coagulometer MNPT (mean 11.25%). The system ISI tested with ACL coagulometers gave less correction than the local ISI calibration. The local system calibration with lyophilized plasmas also avoids some of the constraints on conventional thromboplastin calibrations.

Calibration↗

The reliability of the mean normal prothrombin time of fresh plasmas and of the normal value from a lyophilized 'normal' plasma in prothrombin ratio determination.

The mean normal prothrombin time (MNPT) based on the fresh plasma of 20 healthy individuals is the recommended way to derive a normal value for the prothrombin ratio. This is generally believed to give a reasonable representation of the normal in the local population, but there may be difficulty in obtaining a good representative sample in some centres. The alternative of a uniform lyophilized 'normal' plasma has been suggested. The comparative value of a widely used commercial 'normal' plasma and the MNPT has been assessed in an international study at 37 centres. Two common thromboplastins were tested using the local coagulometer methods. The variability of the results and their relative performance in local thromboplastin calibration to derive the International Sensitivity Index (ISI) were assessed. The reliability of the two types of normal in local system ISI calibration with different lyophilized plasma calibrants has also been tested. When the lyophilized 'normal' was substituted for the MNPT in ISI determination no appreciable difference in the degree of correction for coagulometers effects on International Normalized Ratios was found.

Calibration↗

Results of a multicenter study assessing the status of standardization of a recombinant thromboplastin for the control of oral anticoagulant therapy.

An international collaborative study involving 20 laboratories was undertaken to evaluate the status of standardization of a commercial recombinant thromboplastin. The results show that the reagent fulfills the WHO requirements for thromboplastin calibration against two International Reference Preparations (IRP) from different species, because there was a linear relationship of log-transformed prothrombin times as measured by the recombinant reagent and the two IRPs in normal individuals and patients stabilized on oral anticoagulants. The regression lines drawn through the patient data points passed through the normal data points in the majority of instances. The average ISI values for three different batches were close to unity. On the average, the ISI value calculated against BCT/253 (human, plain) was slightly smaller than that against RBT/79 (rabbit, plain). The between laboratory precision of calibration (CV = 5-6%) did not change whether BCT/253 or RBT/79 was used, whereas it was substantially improved when the calibrations of batches 2 and 3 were performed against batch 1, arbitrarily taken as standard (CV < or = 1.7%). Statistical analysis to test for differences between slopes revealed no significant between-batch differences in 16 of 20 laboratories. However slight differences for the third batch (2.8% less than the average ISI value of batches 1 and 2) leave room for further improvement in the standardization of the reagent.

Animals↗

Laboratory monitoring of oral anticoagulant therapy.

The safety and success of oral anticoagulant treatment are dependent on laboratory control by the prothrombin time test. Until recently, the therapeutic range in prothrombin ratios of 2.0 to 2.5 resulted in greatly different dosage regimes, because of the lack of standardization of the test, particularly its thromboplastin component. Low-dose warfarin was associated with responsive thromboplastin. In North America and many other countries, a high-dose regime from high international sensitivity index thromboplastin caused more bleeding.

Administration, Oral↗

Long-term stability studies on the WHO IRP for thromboplastin (human plain BCT/253).

Long-term stability studies on the WHO second primary International Reference Preparation (IRP) for thromboplastin (human plain BCT/253) stored at -20 degrees C have been conducted for ten years. Three centres took part in the exercise using frozen normal and coumarinised plasma samples which were tested throughout. There has been no measurable change in the prothrombin time performance of the human plain IRP over the ten-year period. It can therefore be concluded that new IRP may continue to be calibrated against this preparation in accord with WHO recommendations.

Analysis of Variance↗

The inter-relationship of factor VII and its activity state with plasma lipids in healthy male adults.

A close inter-relationship between raised factor VII clotting activity and elevated blood lipids, particularly serum triglycerides, is well established. A study of factor VII, its activation state and of plasma lipids has been undertaken in two groups of healthy middle-aged males to elucidate this mechanism. A control group with normal factor VII levels were closely matched for age and body-mass index with a second group with elevated levels. Factor VII assays, using rabbit and bovine thromboplastin and a factor VII Ag method, were employed. Triglycerides correlated with the rabbit factor VII thromboplastin assay and factor VII Ag (P < 0.05) but not with the bovine thromboplastin method. Higher HDL-cholesterol and apolipoprotein A-I levels were found in subjects with increased factor VII (P < 0.001) and appeared to be due to differences in alcohol consumption. Cholesterol levels were significantly higher with elevated factor VII. Differential testing suggests that higher factor VII is predominantly mediated through a rise in total VII, rather than an increase in its activity state.

Adult↗

Effect of the choice of WHO International Reference Preparation for thromboplastin on International Normalised Ratios.

AIMS: To compare the International Normalised Ratio (INR) obtained directly with the two types of WHO plain International Reference Preparation for thromboplastin in patients treated with coumarin. METHODS: Prothrombin times were performed in parallel at four centres using WHO human plain IRP (BCT/253) and rabbit plain IRP (RBT/79). Sixty patients and 20 normal controls were tested at each centre. Differences in INR among the centres were assessed by one factor, analysis of variance. The bias for each centre was assessed by the t test. RESULTS: At all four centres higher INRs were consistently found with the rabbit plain reagent. Two of the centres showed significantly greater bias. CONCLUSIONS: There was a small but significant difference in INR results obtained directly with these two reference reagents at all four centres (mean 7.35%). This in part may result from the different responsiveness of the two IRP to the coumarin defect or to imprecision of the original ISI calibrations of the two plain WHO IRP. The findings support the adoption of a single master IRP, in accord with WHO recommendations, which would resolve the present anomalous situation.

Analysis of Variance↗

Prospective comparative study of computer programs used for management of warfarin.

AIMS: To compare the effectiveness of three computerised systems that are currently used for assisting warfarin control in outpatients with the customary dosing method used by experienced medical staff. METHODS: A pilot randomised study of three systems with a follow up independently randomised study of two of these was made on 186 patients receiving long term treatment or who had recently started warfarin treatment and had been discharged from hospital. RESULTS: All three computerised systems seemed to give satisfactory control compared with the traditional dosing method. For patients receiving more intensive treatment with an assigned target range of 3.0-4.5 computerised dosage programs achieved significantly better control; the medical staff undertreated such patients almost 50% of the time. CONCLUSION: Computer based programs can assist outpatient anticoagulant control with warfarin during both early and long term treatment. For most patients the control achieved is as good as that obtained by the customary method of dosing, by experienced clinic doctors, although the latter tend to be too conservative when dosing patients within the intense target range of 3.0 to 4.5 International Normalised Ratio (INR). The computers were significantly more successful in this higher range.

Adult↗