PubMed Health⌕ Search

Biomedical subjects

L Porretti

Publications and source records attributed to L Porretti.

At least 19 recordsLinked to original sources

Skin-derived stem cells transplanted into resorbable guides provide functional nerve regeneration after sciatic nerve resection.

The regeneration in the peripheral nervous system is often incomplete and the treatment of severe lesions with nerve tissue loss is primarily aimed at recreating nerve continuity. Guide tubes of various types, filled with Schwann cells, stem cells, or nerve growth factors are attractive as an alternative therapy to nerve grafts. In this study, we evaluated whether skin-derived stem cells (SDSCs) can improve peripheral nerve regeneration after transplantation into nerve guides. We compared peripheral nerve regeneration in adult rats with sciatic nerve gaps of 16 mm after autologous transplantation of GFP-labeled SDSCs into two different types of guides: a synthetic guide, obtained by dip coating with a L-lactide and trimethylene carbonate (PLA-TMC) copolymer and a collagen-based guide. The sciatic function index and the recovery rates of the compound muscle action potential were significantly higher in the animals that received SDSCs transplantation, in particular, into the collagen guide, compared to the control guides filled only with PBS. For these guides the morphological and immunohistochemical analysis demonstrated an increased number of myelinated axons expressing S100 and Neurofilament 70, suggesting the presence of regenerating nerve fibers along the gap. GFP positive cells were found around regenerating nerve fibers and few of them were positive for the expression of glial markers as S-100 and glial fibrillary acidic protein. RT-PCR analysis confirmed the expression of S100 and myelin basic protein in the animals treated with the collagen guide filled with SDSCs. These data support the hypothesis that SDSCs could represent a tool for future cell therapy applications in peripheral nerve regeneration.

Action Potentials↗

Animal model for liver cell banking from non-heart beating donors after prolonged ischaemia time.

BACKGROUND AND AIM: Although there is a growing interest on the use of non-heart beating donors to enlarge the liver donor pool, livers with prolonged warm ischaemia time are not currently considered for organ transplantation. We hypothesised that these organs may represent a source of hepatocytes for cell transplantation and/or use in bioartificial liver devices. Thus, we investigated if prolonged ischaemia could influence the recovery and viability of functional hepatocytes dissociated from rat livers. METHODS: Hepatocytes were isolated from the liver within 15 min after death (t=15 min) and after 4, 8 and 12h of ischaemia. Cells were either maintained in culture or cryopreserved. In all products, we evaluated cell recovery and viability, hepatocyte markers and cellular functions, including albumin and urea production. RESULTS: The number of cells per gram of tissue was similar at 15 min, 4 and 8h, while it was significantly decreased at 12h. About 0.2 x 10(6) viable cells expressing hepatocyte markers and producing albumin and urea were isolated up to 8h of ischaemia per gram of tissue. CONCLUSIONS: Recovery of viable and functional hepatocytes seems possible after prolonged ischaemia time. These data warrant the evaluation of hepatocyte isolation from human livers of non-heart beating donors.

Animals↗

High frequency of anti-endomysial reactivity in candidates to heart transplant.

BACKGROUND: A possible link between coeliac disease and dilated cardiomyopathy has recently been suggested. AIMS: . To assess the frequency of anti-endomysial antibodies, the marker for coeliac disease, in patients with different forms of heart failure, and to establish the clinical features of those endomysial antibody positive. SUBJECTS AND METHODS: . A total of 642 consecutive patients entering the waiting list for heart transplantation from 1995 through 1997 were studied. The prevalence of endomysial IgA antibodies, determined by indirect immunofluorescence, was compared to that observed in three surveys conducted in the Italian general population. RESULTS: Of the 642 patients, 12 (1.9%; 95% confidence interval 0.97-3.2) resulted endomysial antibody positive, versus 34/9,720 healthy controls (0.35%; 95% confidence interval, 0.23-0.47), accounting for a relative risk of 5.3 (95% confidence interval, 2.8-10.3). Anti-endomysial antibodies were found in 6/275 patients with dilated cardiomyopathy and 6/367 with other forms of heart failure (2.2% versus 1.6%; 95% confidence interval 0.8-4.7 and 0.6-3.5), with no statistical difference. The 12 endomysial antibody positive patients were leaner (body mass index, 22.0 +/- 1.9 vs 24.2 +/- 3. 1, p<0. 05) than 36 seronegative patients matched for baseline demographics and aetiology of cardiomyopathy No differences were observed as regards clinical, biochemical and echocardiographic features, mortality in waiting list and 2-year post-transplant survival. CONCLUSIONS: Patients with end-stage heart failure are at increased risk for coeliac disease as compared to the general population.

Adult↗

Evaluation of the effect of cryopreservation on ex vivo expansion of hematopoietic progenitors from cord blood.

In previous studies, we identified a cytokine cocktail including thrombopoietin, Flt-3 ligand, interleukin (IL)-6 and IL-11 in serum-free medium, suitable to induce significant and sustained ex vivo expansion of primitive hematopoietic stem cells (HSCs) from cord blood (CB) for up to 10 weeks. The aim of the present study was to evaluate the effects of cryopreservation on ex vivo expansion of HSCs and their committed progenitors. CD34+ cells were purified from CB units, each of which was processed in part as such and in part as cryopreserved and thawed, then expanded for 5 weeks in serum-free medium with the cytokine cocktail described above. We determined the number of nucleated cells (NC), CD34+, CD34+/38(-)/33(-), CD34+/61+, CD61+ cells and the clonogenic potential. After 2 weeks the median fold expansion of NC, CD34+ and CD34+/38(-)/33(-) cells was around two log both with fresh and cryopreserved CB and the expansion continued similarly until week 5. Our data suggest that this serum free protocol induces similar ex vivo expansion of HSCs and their committed progenitors from both fresh and cryopreserved CB. Our findings can be useful in view of clinical applications, since CB used for transplantation is stored in the cryopreserved state.

Blood Preservation↗

Long-term expansion and maintenance of cord blood haematopoietic stem cells using thrombopoietin, Flt3-ligand, interleukin (IL)-6 and IL-11 in a serum-free and stroma-free culture system.

Although cord blood (CB) compares favourably with other haematopoietic stem cell (HSCs) sources, its use in large patients is limited by the low number of cells available. Ex vivo expansion of CB HSCs has been used to overcome this limitation. In this study, we investigated the effect of different cytokine cocktails, including interleukin (IL)-6, IL-11, Flt3-ligand (FL) and thrombopoietin (TPO) combined with serum or serum-free medium on the ex vivo expansion of CD34+ cells from CB. Initial experiments showed that expansion could be slightly improved using serum, but we chose to use serum-free medium in the subsequent investigations to apply good medical practice (GMP) conditions suitable for clinical use. The highest expansion of CD34+ cells was obtained with a cocktail containing FL + TPO + IL-6 + IL-11. The median (range) fold expansions of CD34+ cells at 5 and 10 weeks with serum-free medium were 235.6 (131.3-340) and 5205.6 (4736.6-5674.7) respectively. The absence of IL-11 was associated with a similar fold expansion after 5 weeks (median 215.6, range 149.8-281.5), but after 10 weeks expansion was slightly lower (median 1314.7, range 645-1984.4). Our data support the possibility of maintaining long-term expansion of CB HSCs in a simple stroma- and serum-free system.

Antigens, CD34↗

The 'cherry buffy-coat syndrome', a cause of decreased platelet yield in platelet concentrates obtained from buffy-coats.

BACKGROUND AND OBJECTIVES: A large number of European blood centres, including our own, use the buffy-coat method for platelet production. In this article we describe a previously unnoticed phenomenon shown by a proportion of buffy-coats, which display an unusually bright cherry colour and low platelet counts. MATERIALS AND METHODS: We performed bacterial cultures, platelet counts, pO2, pCO2 and pH, and evaluated platelet activation by flow cytometry in cherry versus normal-colour (control) buffy-coats. In addition, we compared donor characteristics in the two groups and platelet counts in the packed red blood cells (RBC) obtained from the original donations. Finally, we monitored the frequency of cherry buffy-coats in the bags of three manufacturers, and determined the concordance rate of two trained technicians in detecting cherry buffy-coats. RESULTS: Bacterial cultures were negative. Cherry buffy-coats contained significantly fewer platelets, more O2, less CO2 and had a significantly higher pH than normal buffy coats. Platelet activation was slightly higher in cherry buffy-coats. RBC from donations yielding cherry buffy-coats contained a significantly higher number of platelets than controls. Donor characteristics were not significantly different. Cherry buffy-coats were significantly more frequent with bags from one manufacturer (24%) than from others (9% and 11.6%). The concordance study showed excellent agreement. CONCLUSIONS: Our hypothesis is that the cherry colour is caused by O2 accumulation in buffy-coats with low platelet counts. The latter may be caused by platelet activation and aggregation during blood processing. Further work is needed to determine the cause of this phenomenon, its frequency in different laboratories and means to prevent it.

Blood Platelets↗

[Hormone evaluation in brain death].

BACKGROUND: In this study, the level and the variation of a number of hormone and metabolic parameters during brain death treatment in potential organ donors have been monitored. METHODS: Thirty-nine consecutive brain-dead patients were enrolled in 3 Intensive Care Units of Regional Hospitals of the North of Italy. All patients were potential organ donors and free from diseases before the accident leading to death. The levels of ADH, ACTH, TSH, prolactin, cortisol, aldosterone, FT3, FT4, renin, serum lactate and plasma osmolality were measured immediately after the diagnosis of brain death (T0), certified following the Italian law of December 29, 1993, n. 578, and after 6 hours (T6). RESULTS: Hormone levels were normal in the majority of subjects, and there was no significant variation during the 6 hours of the observation period. No correlation was found between the hormone levels considered and the metabolic parameters; ADH levels were not correlated with plasma osmolality. FT3 levels were below the normal range in the majority of subjects, but were not associated with a higher lactate level, which is used as a marker of a shift toward tissue anaerobic metabolism. CONCLUSIONS: In conclusion, triiodothyronine administration to improve metabolic order and thus the function of organs for transplantation is not justified in brain-dead patients.

Adolescent↗

Frozen platelet plates for platelet antibody detection and cross-match.

We performed 2 studies aimed at developing a frozen platelet panel suitable for platelet cross-matching. The stability of the most important platelet membrane glycoproteins and the reactivity of antigens of the human platelet antigen (HPA) and of the human leukocyte antigen (HLA) systems were evaluated with the platelet suspension immunofluorescence test (PSIFT) in a panel of platelets frozen in microplates with 6% dimethylsulfoxide. In study No. 1 we evaluated platelet reaction with a broad-spectrum weak anti-HLA and a potent anti-HPA-1a antiserum and the expression of glycoproteins Ib and IIb/IIIa complex on platelet membrane before freezing and after 0.5, 1, 2, 3, 4, 5, 6 and 12 months of storage at -80 degrees C. In study No. 2 we examined platelet reactivity with anti-HPA-1b, -HPA-2a, -HPA-3a, -HLA-A2, -HLA-A3 of platelets stored frozen for 12 months in parallel with fresh platelets from the same donors. Study No. 1 showed that glycoprotein expression was stable and that the weak anti-HLA and the potent anti-HPA-1a antibodies were clearly detected during 12 months at -80 degrees C. Of the 35 paired PSIFT performed in study No. 2 with fresh and frozen/thawed platelets incubated with anti-HPA-1b, -HPA-2a, -HPA-3a, -HLA-A2, -HLA-A3 antisera and AB serum, concordant reactions were obtained in all cases with the exception of 1 case of HLA-A3-positive platelets incubated with anti-HLA-A3 antiserum, that was reactive with frozen/thawed platelets but nonreactive with fresh platelets from the same donor.(ABSTRACT TRUNCATED AT 250 WORDS)

Antigens, Human Platelet↗

Platelet concentrates from buffy coats: improved conditions for preparation and evaluation in routine clinical use.

Since 1990, platelet concentrates prepared by soft centrifugation of buffy-coat pools diluted with a glucose-free, commercially available crystalloid solution (BC-PC) are the first choice product for all platelet recipients in our institution. Numerous in vitro and in vivo observations from our own and other laboratories indicate that BC-PC compare favorably to PC prepared from platelet-rich plasma (PRP). In the present in vitro study we evaluated traditional and bottom-and-top bags and modified centrifugation conditions with the aim of increasing in vitro platelet yield in BC-PC. This was 14-18% higher compared with our previous protocol when prolonged centrifugation and bottom-and-top bags were used. In addition, we evaluated post-transfusion platelet count increments in 42 unselected adult hematological patients routinely transfused with 703 1-5 day-old BC-PC pools. Transfusion data were managed with PLATELET, an MS-DOS compatible program which includes automated calculation of transfusion efficacy and periodic patient reports. Mean pre-, 1 h and 24 h post-transfusion platelet counts were 16, 38 and 28x10 9/L, respectively. Mean 1 h and 24 h post-transfusion platelet count increments, expressed as percentage of expected, were 40 and 24%, respectively. These data were similar to those obtained previously in 189 unselected hematological patients given 2432 PRP-PC transfusions (mean 1 h post-transfusion increment 46% of expected). The present in vitro study confirms that similar platelet yields can be obtained with the BC and PRP methods. In vivo findings show that also in routine conditions post-transfusion increments of PRP-PC and BC-PC are similar.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

White cell-reduced red cells prepared by filtration: a critical evaluation of current filters and methods for counting residual white cells.

White cell (WBC) reduction, red cell (RBC) recovery, and filtration time were determined in 1-day-old standard and buffy coat-depleted RBCs filtered in the laboratory through six commercial filters for WBC reduction. Residual WBCs were counted with a Bürker chamber (BC), with a Nageotte chamber (NC), and by flow cytometry (FC). Results show that BC counts were 0 in several cases in which WBCs were detected with NC and FC, which indicated that the traditional BC method is too insensitive in use with currently available filters. Calibration curves performed by FC and with NC with samples containing known concentrations of WBCs from 1000 to 1 per microL showed that both FC and NC detected, on average, 67 percent of WBCs present in the samples (efficiency). However, the efficiency of FC showed small variability (61-70%) at different WBC levels, whereas the variability with NC was large (39-91%). This greater variability prevented the correction of NC counts by using a single factor and indicated difficulty in NC standardization. Therefore, because our main aim was to compare different filters rather than to define absolute levels of WBC contamination, uncorrected FC and NC counts were chosen to be reported. True WBC counts per unit should not exceed values that can be obtained by dividing uncorrected counts by the lowest efficiencies (61% for FC and 39% for NC). Uncorrected NC and FC counts were below 2 x 10(6) per unit in all units processed through three of the filters and below 5 x 10(6) per unit in all units processed through the other three.(ABSTRACT TRUNCATED AT 250 WORDS)

Erythrocytes↗