Facet coverage in children on flexion lateral cervical radiographs.

STUDY DESIGN: This radiographic study was designed to attempt to develop standards of facet coverage (overlap) on lateral cervical radiographs during voluntary flexion. OBJECTIVE: To produce normative standards for minimum facet coverage in children. SUMMARY OF BACKGROUND DATA: Previous studies on normative standards of facet coverage have been performed only in adults. METHODS: Thirty-six children with minor trauma had lateral flexion-extension radiographs. A standard filming sequence was used in all. Facet joint overlap at each level was divided by the anteroposterior diameter of the upper adjacent cervical body at each level. RESULTS: On linear regression analysis, these ratios did not vary significantly with age at C2-C3 through C6-C7. Means and standard deviations were determined for C2-C7. CONCLUSIONS: These ratios may prove useful in evaluation of children with possible ligamentous injury.

Adolescent

Head-wag autotomography of the upper cervical spine in infantile torticollis.

BACKGROUND: Infants with torticollis require evaluation of the entire cervical spine for vertebral anomalies as part of the work-up, but open-mouth views to assess occiput to C2 are difficult to obtain. OBJECTIVE: To evaluate a "head wag" autotomographic technique for the frontal projection of this region. MATERIALS AND METHODS: Twenty infants under one year of age were evaluated using this technique. RESULTS: Sixteen of 20 could be adequately evaluated using this simple, low-radiation-dose procedure. CONCLUSION: For infants with torticollis in whom vertebral anomalies need to be excluded, the "head wag" technique is useful.

Cervical Vertebrae

Musculoskeletal computed radiography in children: scatter reduction and improvement in bony trabecular sharpness using air gap placement of the imaging plate.

The effect of various air gaps on computed radiographic musculoskeletal images was investigated using a knee phantom. Scatter to primary radiation ratios were measured using the beam stop method at air gaps ranging from 0 to 30 in. (0-762-mm). Bony trabecular sharpness, line pair resolution, quantum mottle and visualization of low-contrast beads in the soft tissues were evaluated. A significant reduction of scatter to primary radiation ratio, from a value of almost 1 at table top to about 0.4 at 10-in. (254-mm) air gap and about 0.2 at 25-in. (635-mm) air gap placement of the computed radiography (CR) imaging plate, was obtained. A progressive improvement in bony trabecular sharpness and line pair resolution, compared with the table top and Bucky images was observed on 10-in. (254-mm) through 25-in. (635-mm) air gap images. Sharpness of the bony trabeculae and line pair resolution were best on the 25-in. (635-mm) air gap images. The skin entrance radiation dose does not have to be increased for air gap digital radiography. The radiographic noise or quantum mottle is highest on the Bucky image, higher on air gap images and minimal on the table top images, despite a high scatter to primary radiation ratio at the table top. The lower quantum mottle on the table top images allowed for maximal visualization of low contrast densities in the soft tissues. Air gap radiography further improves musculoskeletal computed imaging by reducing the scatter to primary radiation ratio without an increase in the skin entrance dose. For significant reduction of the scatter to primary radiation ratio and best evaluation of line pair spatial resolution and bony trabeculae, a 25-in. (635-mm) air gap with digital radiography would be optimal. For evaluation of low contrast densities in the soft tissues, table top placement would be the technique of choice.

Air

Pediatric musculoskeletal computed radiography.

BACKGROUND: In conventional radiography, a film-screen system serves as the X-ray detector and the film also functions as an archival and display medium. Unlike film-screen radiography, these functions are uncoupled in computed radiography (CR). CR uses conventional radiographic equipment to expose an image on a storage phosphor plate instead of a film-screen combination. OBJECTIVE: To review the basic concepts of CR and to provide a background for discussion of specific musculoskeletal applications of CR in children. MATERIALS AND METHODS: Various aspects of musculoskeletal CR in children are presented based on our 4 years' experience and a review of the literature. RESULTS: A greater amount of scatter capture occurs with storage phosphor CR than with a film-screen system in the 70- to 120-kVp range. This is attributed to a lower K-absorption edge of barium in the barium fluorohalide (BaFBr) compound used in the imaging plate. A significant reduction of scatter to primary radiation, improvement in bony trabecular sharpness, and improvement in line pair resolution can be achieved in pediatric musculoskeletal imaging using an air gap without an increase in the skin entrance dose as compared to the non-grid table top technique. With CR, in addition to proper radiographic exposure technique, one needs to preprogram and select the optimal processing technique for each anatomic region, projection and age group of the child. CONCLUSION: The main advantages of CR in pediatric musculoskeletal imaging consist of a reduction in radiation dose for many applications, improved contrast resolution, near elimination of repeat radiographs related to exposure errors, and digital processing capabilities for image enhancement, storage, retrieval, display and transmission. The current limitations of CR include the moderately high start-up cost, the long learning curve to produce optimal films, and the reduced spatial resolution.

Artifacts

Pediatric air-gap chest digital imaging: an experimental study.

Geometrically magnified computed radiography (CR) chest radiographs can be obtained in children using the same techniques as for non-grid, non-magnified CR radiographs. The resulting magnification images have less scatter than grid images and better line pair resolution.

Adolescent

Optimal timing of abdominal CT in children: relationship to injection rate.

PURPOSE: To study computed tomographic (CT) scanning technique in relationship to rate of injection of contrast material for imaging of the liver and other abdominal organs in pediatric patients. MATERIALS AND METHODS: The time from start of injection of 2 mL/kg iohexol to peak opacification in the aorta, hepatic vein, liver, and kidney was determined for injection rates of 0-0.99, 1.00-1.99, 2.00-2.99, 3.00-3.99, and 4.00 mL/kg or more per minute in 77 pediatric patients. RESULTS: Peak liver opacification varied only slightly with different injection rates, but the time from start of injection to peak opacification in the aorta, hepatic vein, liver, and kidney did vary with injection rate. CONCLUSION: Data provided by this study should allow CT scanning to be timed in relation to injection rate to ensure that maximal organ opacification is achieved as the middle of the organ is being scanned, that adequate hepatic and portal vein opacification is achieved, and that streaking from the renal pelvis is minimized.

Adolescent

Postoperative technetium scanning in patients with submandibular duct diversion.

Submandibular duct diversion is a common procedure for refractory sialorrhea in children. The procedure reroutes Wharton's ducts from the floor of the mouth to the tongue base. As the majority of saliva in the resting state is produced by the submandibular glands, rerouting markedly decreases sialorrhea. However, the procedure has been criticized in that diversion may cause fibrosis and stricture of the ducts. The gland would atrophy, and the physiologic functions of saliva would be lost. Glandular function of six patients with cerebral palsy (mean age, 14.7 years) was evaluated by technetium scanning (mean time after surgery, 43 months). Four patients had normal bilateral function; two patients had no function in one gland but normal function in the contralateral gland. We conclude that bilateral submandibular duct diversion maintains long-term function in at least one gland.

Adolescent

Gastric emptying using three different formulas in infants with gastroesophageal reflux.

The role of delayed gastric emptying (GE) in the pathogenesis of gastroesophageal reflux (GER) in infants is controversial at present. GE has been shown to be altered by the composition and osmolality of the feedings. This prospective study was undertaken to assess the changes in the GE and the percentage of time GER was detected by scintigraphy using three different formulas on consecutive days in infants with GER. Twenty-eight infants under 1 year of age diagnosed to have GER by extended intraesophageal pH monitoring (pH being less than 4.0 for greater than 5% of the duration of the test), underwent scintigraphy on three consecutive days using the same volume per single feeding of a casein-predominant, soy, or a whey-hydrolysate formula in a randomized order. The formulas were isocaloric. Gastric emptying and percentage of GER into the esophagus were estimated for 60 min following these feedings. Mean GER percent during the study was 20.39, 17.68, and 16.34 on casein-predominant, soy, and whey-hydrolysate formulas, respectively, and was not significantly different. Mean values of GE were 39.7%, 44.6%, and 48.5% on casein, soy, and whey formula, respectively. No significant difference in GE was also observed between casein-predominant and soy formula. However, a significant difference was observed (p less than 0.05) on GE between casein-predominant and whey-hydrolysate feedings. Our data suggest that formula selection may be important in the treatment of conditions associated with delayed gastric emptying.

Gastric Emptying

Septal ventricular pacing in the immature canine heart: a new perspective.

Cardiac pacing initiated from epicardial or transvenous apical right ventricular electrodes causes asynchronous ventricular contraction. This alters myocardial stress vectors and results in adverse cellular and subcellular changes in the experimental animal. Clinically, such changes may contribute to the adverse hemodynamics reported with long-term ventricular pacing. To determine the feasibility of direct stimulation of the ventricular specialized conduction systems and therefore the potential for maintenance of normalized depolarization patterns, 13 beagle puppies were studied. Baseline ventricular activation and contraction patterns were obtained using intracardiac electrograms and multigated nuclear acquisition (MUGA) imaging. Septal electrode insertion from the aortoatrial groove was accomplished by use of two-dimensional echocardiography and continuous electrocardiographic (ECG) monitoring of the surface ECG during pacemaker implantation in five puppies. Standard right ventricular epicardial electrodes were implanted in five additional animals, with three remaining as age-matched non-paced controls. After 4 months of observation, repeat MUGA imaging and intracardiac electrograms demonstrated nearly normal biventricular activation and contraction patterns among the septal-paced group. Histopathologic examination illustrated normal cellular morphology in the septal-paced animals. This study demonstrates that pacing electrode insertion into the proximal interventricular septum is feasible and results in utilization of the normal ventricular conduction pathway. Such an approach to initiation of ventricular stimulation may attenuate the adverse effects of long-term ventricular pacing.

Animals

Comparison of indium-111 scintigraphy and colonoscopy with histologic study in children for evaluation of colonic chronic inflammatory bowel disease.

Indium-111 leukocyte scanning and colonoscopy were performed in 19 children and adolescents with chronic inflammatory bowel disease to study the correlation of evaluation between these two diagnostic modalities in comparison to histologic study for colonic disease. Seven patients had ulcerative colitis, 10 had Crohn's disease, and two patients had no specific diagnosis after evaluation. The sensitivity of indium-111 scan was 18%, specificity was 62.5%, and accuracy for diagnosing colonic disease was only 37%. In comparison, sensitivity and specificity for colonoscopy were 100 and 57%, respectively. Furthermore, accuracy with colonoscopy was 84%. Our data suggest that the usefulness of scans is limited to patients in whom standard diagnostic procedures are contraindicated. In addition, it is essential to confirm the visual diagnostic impression on colonoscopy with histologic study.

Adolescent

Myocardial performance and perfusion during exercise in patients with coronary artery disease caused by Kawasaki disease.

For a study of the natural history of coronary artery lesions after Kawasaki disease and their effect on myocardial blood flow reserve with exercise, five such patients underwent exercise testing on a bicycle. Oxygen consumption, carbon dioxide production, minute ventilation, and electrocardiograms were monitored continuously. Thallium-201 scintigraphy was performed for all patients. One patient stopped exercise before exhaustion of cardiovascular reserve but had no evidence of myocardial perfusion abnormalities. Four patients terminated exercise because of exhaustion of cardiovascular reserve; one had normal cardiovascular reserve and thallium scintiscans, but the remaining patients had diminished cardiovascular reserve. Thallium scintigrams showed myocardial ischemia in two and infarction in one. No patient had exercise-induced electrocardiographic changes. These results indicate that patients with residual coronary artery lesions after Kawasaki disease frequently have reduced cardiovascular reserve during exercise. The addition of thallium scintigraphy and metabolic measurements to exercise testing improved the detection of exercise-induced abnormalities of myocardial perfusion.

Adolescent

Exercise performance after repair of anomalous origin of the left coronary artery from the pulmonary artery.

Eleven patients underwent exercise testing after operative repair of anomalous origin of the left coronary artery from the pulmonary artery. Five patients repaired after 2 years of age comprised a childhood surgery group, and six patients repaired before 2 years of age comprised an infant surgery group. All patients were exercised using either a treadmill or electronically braked bicycle with simultaneous thallium 201 scintigraphy. Oxygen consumption, carbon dioxide production, pulmonary functions, and electrocardiogram were all monitored continuously. Pulmonary reserve was normal in all patients. Based on heart rate reserve, respiratory exchange ratio, and oxygen-consumption response to work load, two patients in the infant surgery group stopped exercise before achieving maximum aerobic capacity. All remaining patients achieved their maximum aerobic capacity. There was no difference in work rate or oxygen consumption during exercise between the infant and childhood surgical group. Four patients (two in each surgical group) had an impaired chronotropic response to exercise. Three of these four patients demonstrated perfusion defects by thallium scintigraphy. Thallium scintigraphy was normal in all remaining patients. Electrocardiographic abnormalities were noted in seven of 11 patients having ventricular arrhythmias or ST segment depression. It is concluded from this study that exercise performance after repair of anomalous origin of the left coronary artery from the pulmonary artery is not affected by the age at which surgery is performed. Exercise is frequently associated with electrocardiographic evidence of abnormal myocardial perfusion despite frequently negative simultaneous 201Tl scintigraphy.

Cardiac Catheterization

Lack of correlation between extended pH monitoring and scintigraphy in the evaluation of infants with gastroesophageal reflux.

Sixty-nine infants younger than 1 year of age, with symptoms of persistent vomiting, recurrent choking, apnea, persistent cough, or stridor, were evaluated for gastroesophageal reflux. All infants underwent extended intraesophageal pH monitoring for 16 to 24 hours as well as gastroesophageal scintigraphy with technetium 99m sulfur colloid to study the correlation between the two tests. Forty-eight infants exhibited reflux with extended pH monitoring whereas 46 infants showed reflux with scintigraphy. However, the diagnosis of reflux in individual patients by extended pH monitoring corresponded poorly with the diagnosis of reflux in the same patients by scintigraphy. Similarly, no correlation was observed between extended pH monitoring and scintigraphy results, whether expressed as percent gastric emptying or as gastroesophageal reflux ratio. We conclude that extended pH monitoring and scintigraphy measure different pathophysiologic phenomena and detect reflux under different conditions. The ability of these tests to detect reflux may be complementary and they may be of greatest value when used together to enhance the sensitivity and specificity of the diagnostic evaluation. Extended pH monitoring and scintigraphy should not be used interchangeably to monitor gastroesophageal reflux.

Esophagus