Stripping-theory analysis of thick-target neutron production for D + Be.

The Serber theory for deuteron stripping is employed to predict the shape of the neutron energy spectrum produced by 35 MeV deuterons (D+) on a thick beryllium target. In particular, the observation that the maximum of the neutron energy spectrum (at 0degrees relative to the deuteron beam direction) occurs at approximately 0-4Ed, where Ed is the incident deuteron energy, is explained reasonably well by the calculations. The explanation stems mainly from the fact that the stripping theory for thin targets predicts a narrow maximum at 0-5Ed, and thick target effects shift the maximum downward in energy to approximately 0-4Ed. A number of recent spectral measurements are in agreement with these predictions for a wide range of target materials and incident deuteron energies. The application of this theory also accounts for the previously observed Dd2-99 dependence of the absorbed dose in tissue,per unit charge of D+ ions on target, in the direction of the incident beam. This approximate Ed3 dependence is shown to be a characteristic property of deuteron stripping in a thick target and follows directly from the calculations that predict the neutron energy spectrum.

Beryllium↗

Cesium-129 myocardial scintigraphy to quantify myocardial infarction in dogs.

The sizes of surgically induced acute myocardial infarctions were quantified in a study of 28 dogs. Four projections (right and left anterior oblique, anterior, and left lateral) were obtained with 129Cs myocardial scintigraphy. Control images, taken before surgery, were compared with images taken 24-72 hr after coronary artery ligation. From postmortem examination the size of the infarct was determined and expressed as a percentage of the total left ventricle. On a standard diagram four independent observers marked the infarcted areas in each projection, expressed the severity of involvement in each area, and determined overall infarction size as a percentage of the total left ventricle. A nonlinear least-squares method was also employed to derive the size of the infarct, using the results from each observer's diagram. There were positive correlations between each observer's percentage estimate and the autopsy results. The overall accuracy of the least-squares method was similar to that of the individual observers. In this study, Observer 3 proved that acute myocardial infarcts can be quantified accurately from multiple scintigraphic projections of the myocardium, but the other three observers had difficulty in estimating infarct size. This difficulty probably resulted from the lack of well-validated criteria to aid the observer in determining the area of infarction, the severity of involvement within that area, or the total size of a myocardial infarct. Improvement in these estimates will require the development of definitive criteria, the use of optical scanners or computer processing, and combinations of radionuclides.

Animals↗

Effects of myocardial hypoxia and ischemia on myocardial scintigraphy.

The effect of regional myocardial ischemia and hypoxia on myocardial scintigraphy was studied in patients and dogs after intravenous administration of cesium-129. Seven men with angiographically proved ischemic heart disease underwent exercise testing and 129Cs was given immediately when ischemia was manifested in the electrocardiogram. Defects were not evident in the scintigrams of any patient. Failure to visualize a defect might be related to delayed uptake of 129Cs by the myocardium (maximal uptake in 45 minutes). The ischemic state was dissipated before the disparity in uptake between normal and ischemic myocardium could be visualized. Cesium-129 is useful for identifying acute myocardial infarcts but should not be used to visualize transient exercise-induced regional ischemia. Six dogs were given 129Cs after induction of regional myocardial hypoxia by perfusion of the anterior descending coronary artery with venous blood. In each, scintigraphy revealed a defect that resolved after reperfusion with arterial blood. Two other dogs were given 129Cs before perfusion with hypoxemic blood; neither dog manifested a defect. Since perfusion was maintained by a pump these results suggest that the major cause of the scintigraphically observed defect was inadequate cellular uptake of 129Cs rather than excessive cellular loss. Since regional myocardial hypoxia produced a reversible defect, scintigraphic studies might overestimate the size of an acute myocardial infarct in man by including the ischemic zone surrounding the infarct.

Adult↗

Radiobiological properties of high-energy cyclotron-produced neutrons used for radiotherapy.

Radiobiological properties of high-energy cyclotron-produced neutrons were investigated. The survival curve for mammalian cells exposed to 35 MeV neutrons has an appreciable shoulder, but exhibits a significant initial slope at low doses. split-dose experiments, using doses comparable to the daily fractions of neutron therapy, indicate no repair of sublethal damage. The nitroimidazoles, and particularly Flagyl, have been shown to selectively sensitize hypoxic cells to the effects of x-rays. Experiments demonstrated that Flagyl is equally effective in reducing the oxygen enhancement ratio for high-energy neutrons. Hypoxic sensitizers must by regarded as an adjunct to neutron therapy, rather than as a competitor.

Animals↗

Displacement correction factor for fast-neutron dosimetry in a tissue-equivalent phantom.

The displacement correction factor to be used for analysis of fast-neutron dosimetric measurements using air-filled EG and G tissue-equivalent ion chambers in a tissue-equivalent phantom has been investigated using the MANTA neutron radiotherapy beam generated by 35-MeV deuterons on a thick Be target. The displacement correction factor inferred from these measurements is 0.970 for the EG and G IC-17 (1.0-cm3) ion chamber, and is 0.989 for the EG and G IC-18 (0.1-cm3 ion chamber. This multiplicative displacement correction factor has no significant dependence on depth in the phantom or on neutron beam size.

Fast Neutrons↗

Scattered radiation from a neutron collimator.

Fast-neutron beams are being employed in radiotherapy trials and associated radiobiology studies at numerous centers in the U.S., Europe, and Japan. Since collimated beams of various sizes and shapes are employed, it is desirable to know the composition of the scattered radiation component contributed by the collimator. A simple method is shown for deducing the field composition in terms of a three-component model, from measurements made with three ionization chambers (tissue-equivalent, graphite, and magnesium). The dose contributed by the scattered radiation in the present example was found to be predominantly due to fast neutrons indistinguishable from those in the primary spectrum (from 35-MeV D+ on Be). This method may prove useful for measurements in phantoms as well.

Fast Neutrons↗

Computer generation of dose distributions for a fast-neutron therapy beam.

A system has been developed for the computer generation of dose distributions for the MANTA-NRL fast-neutron radiotherapy beam. This program is based on scatter-air ratio (SAR) techniques. A method has been developed to unfold the effect of the neutron-beam profile in the derivation of SARs so that the SARs obtained are those which would be derived if the beam profile were flat. Tables of zero-area tissue-air ratios and SARs are presented. Comparisons of calculated and measured dose distributions are shown. An empirical correction to the usual SAR methods was required to obtain agreement between calculated and measured dose distributions at source-to-skin distances (SSD) which are different from the SSD at which the SAR are derived.

Computers↗

Calorimetric and ionimetric dosimetry intercomparisons I: U.S. neutron radiotherapy centers.

In the U.S. neutron radiotherapy trial centers, absorbed dose is routinely measured using commercially available A-150 tissue equivalent (TE) plastic ionization chambers. The collecting volumes of these chambers are filled with either methane-based tissue equivalent gas or air. Absorbed dose in A-150 plastic, determined with these ionization chambers, was compared to that measured by an A-150 plastic calorimeter in an A-150 plastic phantom. These comparisons have yielded the following information: (1) Agreement of the total absorbed dose measured using the ionization chambers was within 2.5% of the calorimeter at all the centers visited to date. (2) For all the neutron fields measured, the product of the stopping power ratio (sw,g)N' between the A-150 plastic chamber wall and TE gas, and the average energy expended in the gas per ion pair formed, WN/e, was computed assuming Bragg-Gray theory and found to be 31.0 +/- 0.7 J/C. (3) The displacement correction factor employed to normalize measurements at a depth in a phantom using the type IC-17 ionization chamber was verified to be approximately 0.97 +/- 0.01.

Calorimetry↗