PubMed Health⌕ Search

Biomedical subjects

L S Polley

Publications and source records attributed to L S Polley.

8 recordsLinked to original sources

Effect of intravenous versus epidural fentanyl on the minimum local analgesic concentration of epidural bupivacaine in labor.

BACKGROUND: The minimum local analgesic concentration (MLAC) has been defined as the median effective local analgesic concentration (EC50) in a 20-ml volume for epidural analgesia in the first stage of labor. The aim of this study was to determine the relative local anesthetic sparing efficacies of intravenous and epidural fentanyl by comparison of their effects on the MLAC of bupivacaine. METHODS: In this double-blind, randomized, prospective study, 84 parturients at < or = 7-cm cervical dilation who requested epidural analgesia were allocated to one of two groups. After lumbar epidural catheter placement, 20 ml bupivacaine (n = 44) or bupivacaine with 3 microg/ml (60 microg) fentanyl (n = 40) was administered. The plain bupivacaine group then received 60 microg intravenous fentanyl. The bupivacaine-fentanyl group received intravenous saline. The concentration of bupivacaine was determined by the response of the previous patient in that group to a higher or lower concentration using up-down sequential allocation. Analgesic efficacy was assessed using 100-mm visual analog pain scores, with < or = 10 mm within 30 min define as effective. RESULTS: The MLAC of bupivacaine-intravenous fentanyl was 0.064% wt/vol (95% confidence interval, 0.049-0.080), and the MLAC of bupivacaine-epidural fentanyl was 0.034% wt/vol (95% confidence interval, 0.017-0.050). Epidural fentanyl significantly increased the analgesic potency of bupivacaine by a factor of 1.88 (95% confidence interval, 1.09-3.67) compared with intravenous fentanyl. The epidural fentanyl group demonstrated significantly higher dermatomal spread (P = 0.0064) and increased pruritus (P = 0. 01). CONCLUSIONS: Epidural fentanyl significantly reduced the MLAC of bupivacaine when compared with intravenous fentanyl for the parturients in this study. The significantly enhanced local anesthetic sparing, dermatomal level, and pruritus with epidural fentanyl suggest a primarily spinal site of action.

Adult↗

Relative analgesic potencies of ropivacaine and bupivacaine for epidural analgesia in labor: implications for therapeutic indexes.

BACKGROUND: The minimum local analgesic concentration (MLAC) has been defined as the median effective local analgesic concentration in a 20-ml volume for epidural analgesia in the first stage of labor. The aim of this study was to assess the relative analgesic potencies of epidural bupivacaine and ropivacaine by determining their respective minimum local analgesic concentrations. METHODS: Seventy-three parturients at < or = 7 cm cervical dilation who requested epidural analgesia were allocated to one of two groups in this double-blinded, randomized, prospective study. After a lumbar epidural catheter was placed, 20 ml of the test solution was given, either ropivacaine (n = 34) or bupivacaine (n = 39). The concentration of local anesthetic was determined by the response of the previous patient in that group to a higher or lower concentration using up-down sequential allocation. Analgesic efficacy was assessed using 100-mm visual analog pain scores with < or = 10 mm within 30 min defined as effective. An effective result directed a 0.01% wt/vol decrement for the next patient. An ineffective result directed a 0.01% wt/vol increment. RESULTS: The minimum local analgesic concentration of ropivacaine was 0.111% wt/vol (95% confidence interval, 0.100-0.122), and the minimum local analgesic concentration of bupivacaine was 0.067% wt/vol (95% confidence interval, 0.052-0.082). Ropivacaine was significantly less potent than bupivacaine, with a potency ratio of 0.6 (95% confidence interval, 0.49-0.74). No difference in motor effects was observed. CONCLUSION: Ropivacaine was significantly less potent than bupivacaine for epidural analgesia in the first stage of labor.

Adult↗

Dose-dependent reduction of the minimum local analgesic concentration of bupivacaine by sufentanil for epidural analgesia in labor.

BACKGROUND: The minimum local analgesic concentration (MLAC) has been defined as the median effective local analgesic concentration in a 20-ml volume for epidural analgesia in the first stage of labor. The aim of this study was to determine the local anesthetic-sparing efficacy of epidural sufentanil by its effect on the MLAC of bupivacaine. METHODS: In this double-blind, randomized, prospective study, 147 parturients at < or = 7 cm cervical dilation who requested epidural analgesia were allocated to one of four study groups. After a lumbar epidural catheter was placed, study participants received 20 ml bupivacaine (n = 38), bupivacaine with sufentanil 0.5 microg/ml (n = 38), bupivacaine with sufentanil 1 microg/ml (n = 33), or bupivacaine with sufentanil 1.5 microg/ml (n = 38). The concentration of bupivacaine was determined by the response of the previous patient using up-down sequential allocation. The analgesic efficacy was assessed using 100-mm visual analog pain scores, with < or = 10 mm within 30 min defined as effective. RESULTS: The MLAC of bupivacaine alone was 0.104% wt/vol (95% CI, 0.090-0.117). The addition of sufentanil at doses of 0.5 microg/ml, 1 microg/ml, and 1.5 microg/ml resulted in significant reductions (P < 0.0001) in the MLAC of bupivacaine to 0.048% wt/vol (95% CI, 0.030- 0.065), 0.021% wt/vol (95% CI, 0-0.055), and 0.009% wt/vol (95% CI, 0-0.023), respectively. CONCLUSIONS: This study showed a significant (P < 0.0001) dose-dependent reduction in the MLAC ofbupivacaine by sufentanil.

Analgesia, Epidural↗

The effect of epidural fentanyl on the minimum local analgesic concentration of epidural chloroprocaine in labor.

The minimum local analgesic concentration (MLAC) has been defined as the median effective local analgesic concentration (EC50) in a 20-mL volume in the first stage of labor. The aim of this study was to determine the local anesthetic sparing efficacy of epidural fentanyl by its effect on the MLAC of chloroprocaine. Fifty-six parturients, not exceeding 7 cm cervical dilation, who requested epidural analgesia were allocated to one of two groups in this double-blind, randomized, prospective study. After placing a lumbar epidural catheter, 20 mL of the solution being tested was given: chloroprocaine (n = 28) or chloroprocaine with fentanyl 3 micrograms/mL (60 micrograms) (n = 28). The concentration of chloroprocaine was determined by the response of the previous patient to a higher or lower concentration using up-down sequential allocation. Analgesic efficacy was assessed using 100-mm visual analog pain scores with 10 mm or less within 30 min defined as effective. The MLAC of chloroprocaine was reduced from 0.43% wt/vol to 0.26% wt/vol by fentanyl (P = 0.023). Thus, the addition of epidural fentanyl 3 micrograms/mL (60 micrograms resulted in a significant 40% reduction in the MLAC of chloroprocaine in the first stage of labor.

Adult↗