On-line adaptive algorithm with glucose prediction capacity for subcutaneous closed loop control of glucose: evaluation under fasting conditions in patients with Type 1 diabetes.

AIMS: To evaluate an algorithm with glucose prediction capacity and continuous adaptation of patient parameters-a model predictive control (MPC) algorithm-to control blood glucose concentration during fasting conditions in patients with Type 1 diabetes. In the subcutaneous (sc) route within a closed loop system. METHODS: Paired experiments were performed in six patients. Over 8 h the MPC algorithm was used to control glucose with s.c. insulin administration and two different glucose monitoring protocols: first, the algorithm was provided with intravenous (i.v.) glucose values for insulin dosage calculation directly (i.v.-s.c. route). Then, in the second experiment, i.v. glucose values were fed to the MPC with a delay of 30 min to simulate s.c. glucose measurements ('s.c.'-s.c. route). In both experiments plasma glucose, insulin dosage, and serum insulin levels were analysed. RESULTS: Glucose concentration was brought from hyper- to normoglycaemia and kept in the physiological range (6-7 mmol/l) with both routes in all subjects. Mean glucose concentration reached the threshold of 7 mmol/l approximately 2 (i.v.-s.c. route) and 3 ('s.c.'-s.c. route) hours after the start of glucose control with the MPC. During the last 2 h of automated glucose control, mean glucose concentration was 6.3 +/- 0.2 mmol/l and 6.6 +/- 0.3 mmol/l for i.v.-s.c. and 's.c.'-s.c. route, respectively. Glucose concentration, insulin doses, and serum insulin levels did not differ significantly between routes (P > 0.05). CONCLUSIONS: The MPC algorithm is suitable for glucose control during fasting within an extracorporeal artificial beta-cell in the subcutaneous route Type 1 diabetic patients.

Administration, Cutaneous↗

Dose-response relation of liquid aerosol inhaled insulin in type I diabetic patients.

AIMS/HYPOTHESIS: The AERx insulin Diabetes Management system (AERx iDMS) is a liquid aerosol device that enables insulin to be administered to the peripheral parts of the lung. This study aimed to compare the pharmacokinetic and pharmacodynamic properties of insulin which is inhaled using AERx iDMS with insulin which is subcutaneously administered. METHODS: In total, 18 C-peptide negative patients with Type I (insulin-dependent) diabetes mellitus participated in this randomised, open-label, 5-period crossover trial. Human regular insulin was administered subcutaneously (0.12 U/kg body weight) or inhaled by means of the AERx iDMS (dosages 0.3, 0.6, 1.2, and 1.8 U/kg body weight). Thereafter plasma glucose was kept constant at 7.2 mmol/l for a 10-h period (glucose clamp technique). RESULTS: Inhaled insulin provided a dose-response relation that was close to linear for both pharmacokinetic (AUC-Ins(0-10 h); Cmax-Ins) and pharmacodynamic (AUC-GIR(0-10 h); GIRmax) parameters. Time to maximum insulin concentration (Tmax-Ins) and time to maximum glucose infusion rate (TGIRmax) were shorter with inhaled insulin than with subcutaneous administration. The pharmacodynamic system efficiency of inhaled insulin (AUC-GIR(0-6 h) was 12.7% (95% C.I.: 10.2-15.6). CONCLUSION/INTERPRETATION: The inhalation of soluble human insulin using the AERx iDMS is feasible and provides a clear dose response. Further long-term studies are required to investigate safety aspects, HbA1c values, incidence of hypoglycaemic events and the quality of life.

Administration, Inhalation↗

Post-prandial administration of the insulin analogue insulin aspart in patients with Type 1 diabetes mellitus.

AIMS: In intensified insulin therapy, the recent development of short-acting insulin analogues with a very rapid onset of action forces a new discussion in terms of the optimal injection-meal interval. This study evaluated prandial glycaemia in patients with Type 1 diabetes following the subcutaneous injection of soluble human insulin (HI) and the insulin analogue insulin aspart (IAsp) at different injection-meal intervals and investigated whether administration of IAsp after the meal might provide satisfactory metabolic control. METHODS: In a randomized, double-blind, double-dummy, four-period crossover study, 20 Type 1 diabetic patients were investigated. Prandial insulin was administered 15 min before the start of the meal (HI(-15min)), immediately before the meal (HI(0min); IAsp(0min)) and 15 min after the start of the meal (IAsp(+15min)). RESULTS: Plasma glucose excursions from baseline levels during the 4 h (PGexc) were highest with HI(0min) (17.9 mmol.l(-1).h; P < 0.05 vs. other treatments) and were not statistically different for HI(-15min), IAsp(0min) and IAsp(15min) (13.6, 11.9 and 14.2 mmol.l(-1).h, respectively). Maximum concentration of plasma glucose (PGmax) was lowest with IAsp(0min) (11.2 mmol/l; P < 0.05 vs. other treatments). PGmax was comparable with HI(-15min), HI(0min) and IAsp(+15min) (13.3, 14.1 and 13.2 mmol/l, respectively). CONCLUSIONS: With regard to prandial glycaemia IAsp(+15min) is as effective as HI(-5min) and superior to HI(0min). Thus, post-prandial dosing of the insulin analogue IAsp offers an attractive and feasible therapeutic option for well-controlled patients with Type 1 diabetes mellitus.

Adult↗

Measurement of interstitial albumin in human skeletal muscle and adipose tissue by open-flow microperfusion.

The absolute concentration of albumin was measured in the interstitial fluid of subcutaneous adipose tissue and skeletal muscle in six healthy volunteers by combining the method of open-flow microperfusion and the no-net-flux calibration technique. By use of open-flow microperfusion, four macroscopically perforated double lumen catheters were inserted into the tissue regions of interest and constantly perfused. Across the macroscopic perforations of the catheters interstitial fluid was partially recovered in the perfusion fluid. Catheters were perfused with five solutions, each containing different concentrations of albumin. Absolute interstitial albumin concentrations were calculated by applying linear regression analysis to perfusate vs. sampled albumin concentration (no-net-flux calibration technique). Interstitial albumin concentrations were significantly lower (P < 0.0001) in adipose tissue (7.36 g/l; r = 0.99, P < 0.0003; range: 4.3-10.7 g/l) and in skeletal muscle (13.25 g/l; r = 0.99, P < 0.0012; range: 9.7 to 15.7 g/l) compared with the serum concentration (48.9 +/- 0.7 g/l, mean +/- SE, n = 6; range: 46.4-50.4 g/l). Furthermore, interstitial albumin concentrations were significantly higher in skeletal muscle compared with adipose tissue (P < 0.01). The study indicates that open-flow microperfusion allows stable sampling of macromolecules from the interstitial space of peripheral tissue compartments. Moreover, the present data report for the first time in healthy humans in vivo the true albumin concentrations of interstitial fluid of adipose tissue and skeletal muscle.

Adipose Tissue↗

Direct access to interstitial fluid in adipose tissue in humans by use of open-flow microperfusion.

To gain direct access to the interstitial fluid (ISF), a new technique called open-flow microperfusion has been evaluated. This method is based on a double-lumen catheter with macroscopic (0.3-0.5 mm diameter) perforations that is inserted into the subcutaneous adipose tissue and constantly perfused. Thus partial equilibration between the ISF and the perfusion fluid occurs. The glucose concentration of the ISF was determined by established (zero flow rate, no net flux, and recirculation procedures) and new (ionic reference and suction technique) calibration methods by use of open-flow microperfusion. The data show that 1) the glucose concentration in the ISF is significantly lower than the corresponding arterialized venous plasma values during basal steady-state conditions (adipose tissue 3.2 +/- 0.10 mM, plasma 5.27 +/- 0.12 mM) as well as during hyperglycemic clamp experiments (adipose tissue 7.3 +/- 0.13 mM, plasma 9.91 +/- 0.16 mM), and 2) it is possible to determine the recovery continuously by using the ion concentration of the ISF as an internal standard (ionic reference).

Adipose Tissue↗

Plasma and interstitial glucose dynamics after intravenous glucose injection: evaluation of the single-compartment glucose distribution assumption in the minimal models.

Recent experimental evidence suggests that estimates of glucose effectiveness (S(G)) from the minimal model of unlabeled glucose disappearance (Cold-MM) are in error. The single-compartment glucose distribution assumption embedded in the model has been indicated as a possible source of error. In this study, to directly examine the single-compartment assumption, we measured plasma and interstitial glucose concentrations after intravenous glucose injection. Additionally, we compared the accuracy of the estimates of glucose effectiveness from the Cold-MM and the single-compartment tracer minimal model (Hot-MM). Paired labeled intravenous glucose tolerance tests (IVGTTs) were performed in each of six C-peptide-negative type 1 diabetic subjects. Two different insulin infusion protocols were used: an infusion at constant basal rates and an infusion at variable rates to mimic a normal insulin response. During the labeled IVGTT with basal insulin infusion, the microperfusion technique was employed to sample adipose tissue interstitial fluid. Marked differences between the plasma and interstitial dynamics of (cold) glucose were observed during the first 22 min after glucose injection. These results suggest that the requirements for a single-compartment representation of glucose kinetics are not satisfied during at least the first 22 min of an IVGTT. Data from the labeled IVGTT with normal insulin response were used to identify the minimal-model parameters. The measure of S(G) derived using the Cold-MM was 3.44-fold higher than the direct measure obtained from the labeled IVGTT with basal insulin infusion (0.0179+/-0.0027 vs. 0.0052+/-0.0010 min(-1), P<0.01). The measure of glucose effectiveness (S(G)*) derived by the Hot-MM was 1.36-fold higher than the direct measure available from the labeled IVGTT with basal insulin infusion (0.0079+/-0.0013 vs. 0.0058+/-0.0004 min(-1), P>0.26). These results suggest that the Hot-MM is more appropriate for the evaluation of glucose effectiveness than the Cold-MM.

Adult↗

Novel system for real-time ex vivo lactate monitoring in human whole blood.

The objective of the study was to evaluate the performance of an amperometric enzyme based lactate sensor and to investigate the possibility of replacing a double lumen catheter based blood withdrawal system with a heparin coated single lumen system. The inner lumen of a double lumen catheter which was placed in a peripheral vein was perfused with heparin solution. The outer lumen was used to collect heparinized blood samples at a defined flow rate. The single lumen system was attached to a heparinized catheter which was also placed in a peripheral vein. The undiluted blood samples were collected at a specified flow rate. A sensor flow chamber incorporating an amperometric thin-film lactate microbiosensor was placed in the sampling line for real-time lactate monitoring. Plasma lactate concentrations were measured during frequently performed hyperlactatemia bicycle ergometer experiments in six healthy volunteers (age 25.8 +/- 2.8 years, BMI 22.7 +/- 1 kg/m2). Additionally, plasma lactate was measured in real-time using the lactate sensors. The first three experiments were performed with a double lumen based catheter system whereas the following three experiments were performed with a heparin coated catheter system. The correlation coefficients of sensor readings and laboratory analyzer results in all six experiments were between 0.93 and 0.99, respectively (P < 0.001). The miniaturized lactate sensors showed a linear range up to 25 mmol/l lactate concentration and 95% response times < 30 s in undiluted serum. During the experiments maximum lactate concentrations of 14 mmol/l were achieved. Improvements of system performance using heparin coated catheter systems could be shown. The overall SD of the sensor readings compared to laboratory results using three double lumen catheter based systems was 0.91 mmol/l whereas the SD using three heparin coated systems was 0.65 mmol/l. In summary, real-time monitoring of lactate in human whole blood is feasible with such a device and can be improved by using heparin coated catheter systems.

Adult↗

Continuous measurement of subcutaneous lactate concentration during exercise by combining open-flow microperfusion and thin-film lactate sensors.

The present study was carried out to investigate in vivo in healthy humans the method of open-flow microperfusion for monitoring of the subcutaneous (s.c.) lactate concentration during rest and cycle ergometer exercise. Using open-flow microperfusion, a perforated double lumen catheter with an inflow and an outflow connection is inserted into the s.c. adipose tissue and perfused with a sterile, isotonic, ionfree fluid. Due to the low flow rate, the fluid partially equilibrates with the surrounding tissue. The equilibrated perfusate passes a sensor flow chamber where the substance of interest and the rate of recovery (i.e. the ratio of sampled concentration to interstitial concentration) are continuously monitored. Within this study, the method was evaluated in four healthy volunteers during cycle ergometer exercise. The relative increase of the lactate concentration was approximately a third in the s.c. tissue compared to the capillary blood and the peak time was delayed on average by 10 min. The correlation coefficient between blood and s.c. tissue lactate concentration ranged from r = 0.41 to r = 0.90 (n = 29) in the individual experiments. The combination of open-flow microperfusion and lactate and conductivity sensors enables on-line monitoring of the s.c. lactate concentration without in vivo calibration during steady-state and cycle ergometer exercise.

Adipose Tissue↗

Lactate metabolism of subcutaneous adipose tissue studied by open flow microperfusion.

Open flow microperfusion and a novel calibration technique (ionic reference technique) were evaluated for the frequent measurement of the absolute lactate concentration in sc adipose tissue. Furthermore, the influence of the plasma insulin concentration on the lactate concentration of sc adipose tissue was investigated during hyperglycemia. Sixteen lean healthy young men participated in the studies. In the postabsorbtive state the mean sc lactate concentrations were 1.29 and 1.36 mmol/L for the ionic reference technique and the no net flux protocol, respectively (not significant, P > 0.05). The simultaneously measured arterialized plasma lactate concentration was significantly lower at 0.77 mmol/L (P < 0.05). Both the sc lactate concentration (1.8+/-0.33 mmol/L) and the plasma lactate concentration (0.96+/-0.03 mmol/L) were significantly elevated during a hyperinsulinemic euglycemic clamp experiment. During a hyperglycemic clamp experiment the sc lactate concentration reached a significantly elevated plateau (2.15+/-0.27 mmol/L) that was not influenced by the increasing plasma insulin concentration. It is concluded that 1) open flow microperfusion combined with the ionic reference technique enables frequent measurement of the sc lactate concentration; 2) sc adipose tissue is a significant source of lactate release in the postabsorbtive state as well as during hyperinsulinemic clamp conditions; and 3) insulin concentrations greater than 180 pmol/L have no further influence on adipocyte stimulation of sc adipose tissue with respect to lactate release.

Adipose Tissue↗

Validation of home blood glucose meters with respect to clinical and analytical approaches.

OBJECTIVE: To evaluate the clinical and analytical accuracy of home blood glucose meters. RESEARCH DESIGN AND METHODS: Six blood glucose meters--Reflolux S (Boehringer Mannheim, Mannheim, Germany), One Touch II (LifeScan, Milpitas, CA), Glucocard Memory (Menarini, Florence, Italy), Precision QID (Medisense, Cambridge, U.K.), HaemoCue (HaemoCue, Angelholm, Sweden), and Accutrend alpha (Boehringer Mannheim, Mannheim, Germany)--were compared with a reference method (Beckman Glucose Analyzer II) under controlled conditions (glucose clamp technique). Validation of the blood glucose meters was accomplished by clinically oriented approaches (error grid analysis), statistical approaches (variance components analysis), and by the criteria of the American Diabetes Association (ADA), which recommend a target variability of < 5%. RESULTS: A total of 1,794 blood glucose monitor readings and 299 reference values ranging from 2.2 to 18.2 mmol/l were analyzed (705 readings < 3.89 mmol/l, 839 readings between 3.89 and 9.99 mmol/l, and 250 readings > 9.99 mmol/l). According to error grid analysis, only Reflolux S and Glucocard M had 100% of estimations within the clinically acceptable zones A and B. Assessment of analytical accuracy revealed substantial differences between the glucose meters after separation of the data into defined glycemic ranges. None of the devices met the ADA criteria. CONCLUSIONS: To evaluate accuracy of blood glucose meters, error grid analysis, as well as statistical models, are helpful means and should be performed together. Analytical performance of currently available home blood glucose meters differs substantially within defined glycemic ranges.

Blood Glucose Self-Monitoring↗

Open-flow microperfusion of subcutaneous adipose tissue for on-line continuous ex vivo measurement of glucose concentration.

OBJECTIVE: To evaluate a novel technique for on-line continuous glucose measurement in subcutaneous adipose tissue, and to investigate its accuracy for detection of hypoglycemia. RESEARCH DESIGN AND METHODS: The method combined an open-flow microperfusion of subcutaneous adipose tissue using a double lumen catheter and an extracorporeal sensor cell. An isotonic ion-free solution was perfused through the inner lumen of the catheter, equilibrated with the subcutaneous tissue fluid, and sampled through the outer lumen. The recovery was continuously monitored as the ratio between the measured sampled fluid conductivity and the subcutaneous tissue fluid conductivity (assumed to have a constant value of 1.28 S/m at 25 degrees C). Glucose concentration was calculated on-line from the measured glucose in the sampled fluid and the measured recovery in healthy volunteers during hyperglycemic glucose loads (n = 8), hypoglycemic hyperinsulinemic clamp (n = 6), and a 24-h monitoring period (n = 7). RESULTS: Subcutaneous glucose concentrations in the fasting state were 94% of the plasma glucose concentrations in arterialized venous samples. According to the error grid analysis, 96.9% of the on-line measured subcutaneous glucose concentrations during hyperglycemia and 96.3% during hypoglycemia were in accurate or acceptable zones. The mean differences between the measured subcutaneous glucose and the actual plasma glucose concentration were -0.06-3.3 mmol/l (hyperglycemia), and -0.6-1.1 mmol/l (hypoglycemia). CONCLUSIONS: By combining open-flow microperfusion, glucose sensor, and conductivity measurement, glucose concentration in the subcutaneous adipose tissue can be monitored on-line, extracorporeally, and continuously without any in vivo calibration, and gives accurate measurements during hyper- and hypoglycemia.

Adipose Tissue↗